CABLING/WIRING SPECIFICATION All cabling work (security, intercom, mechanical control, and phone, data, audio-visual) are to done through the managed cable tray system. It is important that network cable designers and installers be familiar with new cable management products. 1) You are to propose Managed Cable System that should include: Power for Electronics and Computers, Filtered Power, and Power Backup Security System Wiring (Door Access Security) Intercom and Paging Systems (Radio & Announcement) Phone System Wiring (Telecommunications Systems) LAN Data Cables Wireless Network Access Points Fire Alarm System Cabling Heating, Ventilating and Air Conditioning System Control 2) All Cabling/Wiring installation for Data(LAN), Voice (phone), Security Control, CCTV to the designated worstations/places are to be terminated at Server Room, with extra of 3 meters. 3) Fiber Channel and its backup cable may be included for LAN connectivity to all workstation which has to be terminated at the FC Router/Hub at the desginated site for each floor. 4) All cables are to be properly labled at each end. 5) All workstation are to be installed includes the followings: Power Socket (3 gang/units) Phone Socket LAN Port 6) Managed Cable Tray Systems - Wire Basket Cable Tray
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
CABLING/WIRING SPECIFICATION
All cabling work (security, intercom, mechanical control, and phone, data, audio-visual) are to done through the managed cable tray system. It is important that network cable designers and installers be familiar with new cable management products.
1) You are to propose Managed Cable System that should include:
Power for Electronics and Computers, Filtered Power, and Power Backup
Security System Wiring (Door Access Security) Intercom and Paging Systems (Radio & Announcement) Phone System Wiring (Telecommunications Systems) LAN Data Cables Wireless Network Access Points Fire Alarm System Cabling Heating, Ventilating and Air Conditioning System Control
2) All Cabling/Wiring installation for Data(LAN), Voice (phone), Security Control, CCTV to the designated worstations/places are to be terminated at Server Room, with extra of 3 meters.
3) Fiber Channel and its backup cable may be included for LAN connectivity to all workstation which has to be terminated at the FC Router/Hub at the desginated site for each floor.
4) All cables are to be properly labled at each end.
5) All workstation are to be installed includes the followings: Power Socket (3 gang/units) Phone Socket LAN Port
6) Managed Cable Tray Systems - Wire Basket Cable Tray
Please take note that:
1) Data systems are far more likely to be updated and changed than other types of services. Data cable trays have features like side support systems allowing new cable to be added by dropping it into the open side of the tray. Many people don't realize that pulling new cable through existing causes friction and tangling which can easily lead to damage of expensive and sensitive high performance data network cables.
2) Another growing issue is the need to dispose of obsolete cable. It is no longer allowable to abandon older cable because of environmental issues such as lead in pvc coatings, and fire issues such as low toxicity, low smoke concerns.
LINKSYS SR2024Ports24-Port 10/100/1000 Media interfacesRJ-45 Manageableunmanageable Switching features 24 RJ-45 ports for 10BASE-T/100BASE-TX/1000BASE-TX connections Auto negotiation of half-duplex and full-duplex mode for all ports Auto MDI/MDI-X support on all ports for easy cable detection Efficient MAC address learning engine supports up to 8000 MAC addresses Store-and-forward forwarding scheme Standard width and mounting kit (included) for easy installation into a rack Two mini-GBIC ports for easy expansion to other mini-GBIC-equipped switches Integrated 256 KB packet buffer memory Supports jumbo frame of 9 KB Supports IEEE 802.3x full-duplex operation European Union Restriction of Hazardous Substances (RoHS) compliant
Power Supply110-120V AC, 100W
ABBA 19" Closed 20U-1016mm
Rack System19" closed rack 20U depth 1016mm, Top, Bottom, Side + glass front door + back metal door, incl: 1 unit Roof Fan Panel 2 Fan, 100 unit Cage Nut + M6 Screw, 1 unit Vertical Power Distribution Panel 12 Outlets
Rp 9,522,000
ABBA 19" Closed 20U-1150mmRack System19" closed rack 20U depth 1150mm, Top, Bottom, Side + glass front door + back metal door, incl: 1 unit Roof Fan Panel 2 Fan, 100 unit Cage Nut + M6 Screw, 1 unit Vertical Power Distribution Panel 12 Outlets
Rp 10,015,000
ABBA 19" Closed 20U-900mm Rack System19" Closed Rack 20U depth 900mm, incl: 1 unit Roof Fan Panel 2 Fan, 50 unit Cage Nut + M6 Screw, 1 unit Vertical Power Distribution Panel 6 Outlets
Rp 8,150,000
ABBA 19" Closed 30U-1016mmRack System19" closed rack 30U depth 1016mm, Top, Bottom, Side + glass front door + back metal door, incl: 1 unit Roof Fan Panel 2 Fan, 100 unit Cage Nut + M6 Screw, 1 unit Vertical Power Distribution Panel 12 Outlets
Rp 10,398,000
ABBA 19" Closed 30U-1150mmRack System19" closed rack 30U depth 1150mm , top, bottom, side + Glass Front Door + Back Metal Door, incl: 1 unit Roof Fan Panel 2 Fan, 50 unit Cage Nut + M6 Screw, 1 unit Vertical Power Distribution Panel 6 Outlets
Rp 10,934,000
ABBA 19" Closed 30U-900mm Rack System19" closed rack 30U depth 900mm + glass front door + back metal door, incl: 1 unit Roof Fan Panel 2 Fan, 50 unit Cage Nut + M6 Screw, 1 unit Vertical Power Distribution Panel 12 Outlets
Rp 8,940,000
ABBA 19" Closed 42U-1016mmRack System19" closed rack 42U depth 1016mm + glass front door + back metal door, incl: 1 unit Roof Fan Panel 2 Fan, 50 unit Cage Nut + M6 Screw, 1 unit Vertical Power Distribution Panel 12 Outlets
ABBA 19" Closed 42U-1150mmRack System19" closed rack 42U depth 1150mm + glass front door + back metal door, incl: 1 unit Roof Fan Panel 2 Fan, 50 unit Cage Nut + M6 Screw, 1 unit Vertical Power Distribution Panel 8 Outlets
Rp 12,765,000
ABBA 19" Closed 45U-1016mmRack System19" closed rack 45U depth 1016mm, Top, Bottom, Side + glass front door + back metal door, incl: 1 unit Roof Fan Panel 2 Fan, 100 unit Cage Nut + M6 Screw, 1 unit Vertical Power Distribution Panel 12 Outlets
Rp 13,340,000
ABBA 19" Closed 45U-1150mmRack System19" closed rack 45U depth 1150mm + acrylic front door + back metal door, 1 Unit Roof Fan Panel (2 Fan), 12 Outlet ertikal Power Distribution, Cage nut 50 pcs
Rp 14,000,000
ABBA 19" Open Rack 25U Rack System19" Open Rack 25U
Rp 1,779,000
ABBA 19" Open Rack 30U Rack System19" Open Rack 30U
Rp 1,872,000
ABBA 19" Open Rack 42U Rack System19" Open Rack 42U
Rp 2,134,000
ABBA 19" Open Rack 45U Rack System19" Open Rack 45U
19" Wallmounted Rack 12U depth 450mm + Acrylic Front Door (single door), Incl: 1 Unit Single Fan for Wallmount, 20 Unit Cage Nut + M6 Screw, 1 Unit Vertical Power Distributor Panel 6 Outlets, 4 Unit Dynabolt M10
Rp 3,200,000
ABBA 19" Wallmounted 12U-490mm Rack System19" Wallmount Rack 12U depth 490mm + Acrylic Front Door + Back Metal Door (Double Door), Incl: 1 Unit Single Fan for Wallmount, 20 Unit Cage Nut + M6 Screw, 1 Unit Vertical Power Distributor Panel 6 Outlets, 4 Unit Dynabolt M10
Rack System24" Closed Rack Cabinet, 45U, 1016mm, Incl. Glass Front Door + Back Metal Door
Rp 14,605,000
ABBA 24" Closed 45U-1150mmRack System24" Closed Rack Cabinet, 45U, 1150mm, Incl. Glass Front Door + Back Metal Door
Rp 15,360,000
ABBA Package 1 - 19" Closed 20U-900mm Rack System19" closed rack 20U depth 900mm + glass front door + back metal door, incl: 1 unit Roof Fan Panel 2 Fan, 50 unit Cage Nut + M6 Screw, 1 unit Vertical Power Distribution Panel 6 Outlets"Limited Stock, Call us for more information"
Rp 7,280,000
ABBA Package 2 - 19" Closed 30U-900mmRack System19" closed rack 30U depth 900mm + glass front door + back metal door, incl: 1 unit Roof Fan Panel 2 Fan, 50 unit Cage Nut + M6 Screw, 1 unit Vertical Power Distribution Panel 6 Outlets"Limited Stock, Call us for more information"
Rp 7,700,000
ABBA Package 3 - 19" Closed 42U-900mm Rack System19" closed rack 42U depth 900mm + glass front door + back metal door, incl: 1 unit Roof Fan Panel 2 Fan, 50 unit Cage Nut + M6 Screw, 1 unit Vertical Power Distribution Panel 12 Outlets"Limited Stock, Call us for more information"
Rp 9,416,000
ABBA Package 4 - 19" Closed 45U-900mm Rack System19" closed rack 45U depth 900mm + glass front door + back metal door, incl: 1 unit Roof Fan Panel 2 Fan, 50 unit Cage Nut + M6 Screw, 1 unit Vertical Power Distribution Panel 12 Outlets"Limited Stock, Call us for more information"
Rp 10,165,000
ABBA Package A - 19" Wallmounted 8U-490mm Rack System19" Wallmount Rack 8U depth 490mm, Overall (double door), Incl: 1 Unit Single Fan for Wallmount, 20 Unit Cage Nut + M6 Screw, 1 Unit Vertical Power Distributor Panel 5 Outlets, 4 Unit Dynabolt M10"Limited Stock, Call us for more information"
ABBA Package B - 19" Wallmounted 12U-490mm Rack System19" Wallmount Rack 12U depth 490mm, Overall (double door), Incl: 1 Unit Single Fan for Wallmount, 20 Unit Cage Nut + M6 Screw, 1 Unit Vertical Power Distributor Panel 5 Outlets, 4 Unit Dynabolt M10
Rp 3,485,000
ABBA Package C - 19" Wallmounted 15U-490mm Rack System19" Wallmount Rack 15U depth 490mm, Overall (double door), Incl: 1 Unit Single Fan for Wallmount, 20 Unit Cage Nut + M6 Screw, 1 Unit Vertical Power Distributor Panel 5 Outlets, 4 Unit Dynabolt M10
Rp 4,250,000
APC AR2100BLKRack SystemNetShelter VX 42U Enclosure w/Sides Black - Advanced Cooling, Power Distribution and Cable Management for Server and Networking Applications in IT Environments.
US$ 1,299.00
METRO RACK 19" Closed 30U-1016mmRack System19" Closed 30U-1016mm