Page 1
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
TMR Dwg. No.
• Grate/Frames 9x6 Dwg. AS3996
• Recessed Road Gully Units Dwg. 1443, 1444
• Protruded Road Gully Units Dwg. 1443, 1444
• 1220 Road Gully Units Dwg. 1459
• 7x4 Road Gully Units Dwg. 1443, 1444
• Type 28 Road Gully Units Dwg. 1445
• Drainway Units Dwg. 1321, 1322
• Field Inlet Type 1 Dwg. 1309, 1310
• Manhole Roof Slabs Dwg. 1308
• Lintels Dwg. 1313
• Batter Chutes
• Sub Soil Components Dwg. 1116
• Sloping Headwalls
• Q-Seal Headwalls Dwg. 1243
• Box Culverts
• Box Culvert Integrated Headwall
• Interlocking Kerbs
• Wheelstops
• Light Pole Bases Dwg. 1393
C-M TMR Products Index
Page 2
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
Auto Lock Grate & Frame 900x600 Class D Bicycle Safe to AS3996
Lift this Side to Disengage Lock
Auto Lock
990mm (Grate)
1080mm (Frame)
570mm (Grate)
605mm (Frame)
75mm
• The grate will not close until the
Auto Lock is disengaged.
Page 3
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
GRATES BIKESAFE DESIGN TO AS 3996-92 OR TYPE 'A'
Cross Section at rear of grate Model 24R
Aust. Reg. Design No. 120789 Patent No. 602076
Side Section Model 24R
C-M 'RECESSED TYPE' ROAD GULLY UNIT 24 SERIES RGU
(ALIGNMENT USING KERB LIP) 'LIP IN LINE'
400
RGU MODEL C24R
RGU MODEL R24R
RGU MODEL L24R
2400
Page 4
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
GRATES BIKESAFE DESIGN
TO AS 3996-92 OR TYPE 'A'
Cross Section at rear of grate Model 36R
Aust. Reg. Design No. 120789 Patent No. 602076 Side Section Model 36R
C-M 'RECESSED TYPE' ROAD GULLY UNIT 36 SERIES RGU
(ALIGNMENT USING KERB LIP) 'LIP IN LINE'
RGU MODEL R36R
RGU MODEL C36R
Page 5
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
GRATES BIKESAFE DESIGN
TO AS 3996-92 OR TYPE 'A'
Cross Section at rear of grate Model 48R
Aust. Reg. Design No. 120789 Patent No. 602076
Side Section Model 48R
C-M 'RECESSED TYPE' ROAD GULLY UNIT 48 SERIES RGU
(ALIGNMENT USING KERB LIP) 'LIP IN LINE'
Page 6
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
C-M 'PROTRUDED TYPE' ROAD GULLY UNIT 24 SERIES RGU
(ALIGNMENT USING KERB FACE) 'KERB IN LINE'
Also available in 3.6m and
4.8m Series
Grates:
Bikesafe Design to
AS3996 or Type ‘A’
RGU Model L24P
RGU Model R24P
RGU Model C24P
Cross Section at rear of grate
Aust. Reg. Design 120789
Aust. Patent No. 602076
Side Section
Page 7
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
C-M ROAD GULLY INLET UNIT R.G.U. 1220:Anti-Ponding
R.G.U. 1220mm (9 x 6 Grate)
Ideal where space is limited for gully inlet unit... ...driveway ...car park ...townhouse development
• Class ‘D’ Bikesafe grate 900 x 600 wide to AS 3996-92
Model M12
R.G.U. M12 is used to upgrade previous 1220 system.
Internal Pit Size 835 x 930.
140
Page 8
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
C-M ROAD GULLY INLET UNIT TYPE 24R 74
RGU Type L24 R74 RGU Type R24 R74
RGU Type C24 R74
2400
SECTION A-A
Patent Products 74 Class ‘D’ CONCRETE TO AS 3902 CASTINGS TO AS 1830 REINFORCING TO AS 1302 AUST. PATENT NO. 602076
AUST. REG. DESIGN No. 120789
Page 9
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
C-M CONCRETE TYPE 28 ROAD GULLY UNIT
Right Hand
Left Hand
Centre
Notes: 1.3T Swiftlift Anchors to AS4680 Concrete S40 20 to AS3600 Casting Monolithic Reinforcing, Minimum Cover 40mm to AS4691 (Reference Standard
Drawing MRD 1445 Type 28)
Side Section Class D Bikesafe Grate. Design to AS 3996-92
Manufactured in accordance with associated product drawings MRD 1443, 1444, 1445 and 1459
Page 10
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
QDMR Standards 1321 - 1322 IPWEA Standards D0067
Convertor Slabs
Shaft Off Set
1200 475
1350 550
1500 625
1800 775
2100 925
Model Description
0TC0T Chamber Unit Only
1TC0T Left Hand Trough and Chamber
0TC1T Right Hand Trough and Chamber
2TC0T 2 x Left Hand Trough and Chamber
0TC2T 2 x Right Hand Trough and Chamber
3TC0T 3 x Left Hand Trough and Chamber
0TC3T 3 x Right Hand Trough and Chamber
1TC1T Sag Trough and Chamber
1T0C0T Trough
• Suits 1050 - 2100 Shafts • All Units Fitted with
Vaned Grates or as Specified
• No Convertor Slab Required for 1050 Shaft
C-M Drainway System (Monolithic)
Model: 1TC0T
Model: 0TC0T
Model: 1TC1T
Model: 1T0C0T
Model: 0TC1T
1350 Typ
4050 Typ
700 Typ
Chamber and Trough 2700 Typ
576 Typ
Model: 0TC1T
Patent Pending
Page 11
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
Field Inlet Type 1 - TMR
Notes: 1. Concrete S40 TMR 2. Reo: F72 Mesh, Y12 Lig 3. Galvanised Grate & Frame as Specified to AS3996 - Class B 4. 50mm Clear Cover 5. Opening Size: 900x600 or 600x600
Page 12
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
C-M Precast Manhole Roof Slabs Manufactured to TMR, IMEAQ or Council Standards
Available Sizes: 1130mm O.D Private Property – 115mm Thick 1350mm O.D (1050 I.D) – 175mm Thick 1500mm O.D (1050 I.D) – 200mm Thick 1500mm O.D (1200 I.D Sewer) – 200mm Thick 1650mm O.D (1200 I.D Stormwater) – 200mm Thick 1700mm O.D (1200 I.D) – 200mm Thick 1800mm O.D (1350 I.D) – 200mm Thick 1950mm O.D (1500 I.D) – 200mm Thick 2250mm O.D (1800 I.D) – 250mm Thick 2550mm O.D (2100 I.D) – 250mm Thick 1950 EXT 300mm (1500 I.D Expanded) – 200mm Thick 1950 EXT 600mm (1500 I.D Expanded) – 200mm Thick 1950 EXT 900mm (1500 I.D Expanded) – 200mm Thick 600 Class D Stormwater Manhole Upstand – 150mm Thick
Available Openings: 600mm Dia 1050mm Dia
600 x 600 600 x 900 800 x 900 900 x 900
An Extensive Range Of Sizes Are Available Upon Request Custom Sizes Are Made To Order
Cast Iron Cover & Frames Or Grates Can Be Cast In Flush.
Page 13
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
DIMENSIONS Lintel A B C D X Weight
(Kg) VS 1200 830 650 720 230 250 S 2400 2040 1800 1970 400 500 M 3600 3240 3000 3170 690 700 L 4800 4440 4200 4370 1000 900
PRECAST LINTELS
• Lintel Description “VS” Very Small,
“S” Small, “M” Medium
• Dimensions (mm) & Weights (kg)
are Approx. Only
• Manufactured to ISO 9001
ELEVATION
PLAN
MODEL
VS
MODEL
S - M - L
Page 14
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
50mm
Width Internal 330mm External 425mm
Width Internal 440mm External 550mm
Height Internal 110mm External 160mm
Height Internal 160mm External 215mm
C-M Batter Chutes For Use on Embankments
They can be safely handled and easily installed on site
using a 1.3t Swiftlift foot anchor.
Page 15
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
Clean Out Cap
380
80
540
380
110 Dia Outlet Hole
Outlet
Sub-Soil Components
* Pest Proof Flap Available
75
100mm Plastic Cap
300
300
Page 16
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
Nom. Pipe Size
Dimensions (Approx. Only) MASS KG A B C D E
300 1220 415 650 650 270 400
375 1220 480 650 650 160 400
450 1500 570 880 800 350 500
525 1500 650 880 800 220 500
600 1500 720 880 800 210 500
• Concrete S40 MRD
• Class Exposure ‘C’
• Reinforcing 12Y/ RF72
• Lifting Anchors 1.3 Tonne
C-M Precast Sloping Headwall
Side View Rear View
A
C
E
D
B
Page 17
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
Void to be filled post pipe installation.
Q-SEAL HEADWALL PIPE SIZE - 375 - 450 - 525
• The Q-Seal eliminate dislodgement from headwall during high flow
• The Q-Seal achieves a sealing and adhesion to the stormwater pipe by
pouring premix concrete into the void.
• Available in all sizes 375 - 1050
• Subsoil outlets on all headwalls with Q-Seal system.
• TMR Approved in conjunction with standard Drawing 1243.
• Design life of 100 years.
Patent Pending
Nom. Pipe Size
Dimensions (Approx. Only) Weight KG
A B C D E F G
375 500 1490 1010 790 720 110 410 TBA
450 580 1490 1010 790 720 110 410 TBA
525 660 1490 1010 790 720 110 410 TBA
D
E
B
A
12mm Reidbar Galv Ferrules for Curtin Wall
F
G
C
Subsoil Outlets
• Lifting Anchors - 3 x 1.3 Swiftlifts
Page 18
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
Void to be filled post
pipe installation.
Q-SEAL HEADWALL PIPE SIZE - 600 - 675 - 750 - 825
Patent Pending
Nom. Pipe Size
Dimensions (Approx. Only) Weight KG
A B C D E F G
600 752 2120 1460 1100 1330 130 960 1730
675 850 2120 1460 1100 1330 130 960 1550
750 930 2120 1460 1100 1330 130 960 1380
825 1020 2120 1460 1100 1330 130 960 1200
D
E
B
A
12mm Reidbar Galv Ferrules for Curtin Wall
F
G
C
Subsoil Outlets
• The Q-Seal eliminate dislodgement from headwall during high flow
• The Q-Seal achieves a sealing and adhesion to the stormwater pipe by pouring premix concrete into the void.
• Available in all sizes 375 - 1050
• Subsoil outlets on all headwalls with Q-Seal system.
• TMR Approved in conjunction with standard Drawing 1243.
• Design life of 100 years.
• Lifting Anchors - 4 x 2.5 Swiftlifts
Page 19
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
Void to be filled post
pipe installation.
Q-SEAL HEADWALL PIPE SIZE - 900 - 1050
Patent Pending
Nom. Pipe Size
Dimensions (Approx. Only) Weight KG
A B C D E F G
900 1100 2670 1790 1400 1570 130 850 3360
1050 1240 2670 1790 1400 1570 130 850 3210
D
E
B
A
12mm Reidbar Galv Ferrules for Curtin Wall
F
G
C
Subsoil Outlets
• The Q-Seal eliminate dislodgement from headwall during high flow
• The Q-Seal achieves a sealing and adhesion to the stormwater pipe by pouring premix concrete into the void.
• Available in all sizes 375 - 1050
• Subsoil outlets on all headwalls with Q-Seal system.
• TMR Approved in conjunction with standard Drawing 1243.
• Design life of 100 years.
• Lifting Anchors - 4 x 2.5 Swiftlifts
Page 20
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
Range Weight
1.2m Long Weight
2.4m Long
450 x 225 450Kg 900Kg
450 x 300 485Kg 970Kg
450 x 375 520Kg 1040Kg
SMALL BOX CULVERT 450 Series
Australian Standards Reinforced Concrete Box Culverts AS1597.1-2010 - TMR Approved
• Load Class Roadway 0-2m Fill Cover
• Exposure B2
• For Placement Refer to Installation Guide
• Lifting – 4 x 1.3 Swiftlift Anchors
Precast Headwalls are available to suit the range.
Available Lengths
2400
1200
100
700
450
Page 21
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
Range Weight
1.2m Long Weight
2.4m Long
600 x 225 430Kg 860Kg
600 x 300 480Kg 955Kg
600 x 375 590Kg 1175Kg
600 x 450 620Kg 1235Kg
SMALL BOX CULVERT 600 Series
Australian Standards Reinforced Concrete Box Culverts AS1597.1-2010 - TMR Approved
• Load Class Roadway 0-2m Fill Cover
• Exposure B2
• For Placement Refer to Installation Guide
• Lifting – 4 x 1.3 Swiftlift Anchors
Precast Headwalls are available to suit the range.
Available Lengths
2400
1200
850
600
100
Page 22
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
Range Weight
1.2m Long Weight
2.4m Long
750 x 225 590Kg 1180Kg
750 x 300 635Kg 1270Kg
750 x 375 695Kg 1390Kg
750 x 450 735Kg 1465Kg
SMALL BOX CULVERT 750 Series
Australian Standards Reinforced Concrete Box Culverts AS1597.1-2010 - TMR Approved
• Load Class Roadway 0-2m Fill Cover
• Exposure B2
• For Placement Refer to Installation Guide
• Lifting – 4 x 1.3 Swiftlift Anchors
Precast Headwalls are available to suit the range.
Available Lengths
2400
1200
1000
750
100
Page 23
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
Range Weight
1.2m Long Weight
2.4m Long
900 x 225 670Kg 1340Kg
900 x 300 720Kg 1440Kg
900 x 375 760Kg 1520Kg
900 x 450 810Kg 1620Kg
SMALL BOX CULVERT 900 Series
Australian Standards Reinforced Concrete Box Culverts AS1597.1-2010 - TMR Approved
• Load Class Roadway 0-2m Fill Cover
• Exposure B2
• For Placement Refer to Installation Guide
• Lifting – 4 x 2.5T Swiftlift Anchors
Precast Headwalls are available to suit the range.
Available Lengths
2400
1200
100
1150
900
Page 24
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
Range Weight
1.2m Long Weight
2.4m Long
1200 x 300 840Kg 1680Kg
1200 x 375 960Kg 1915Kg
1200 x 450 1005Kg 2010Kg
1200 x 600 1095Kg 2190Kg
SMALL BOX CULVERT 1200 Series (300 – 600)
Australian Standards Reinforced Concrete Box Culverts AS1597.1-2010 - TMR Approved
• Load Class Roadway 0-2m Fill Cover
• Exposure B2
• For Placement Refer to Installation Guide
• Lifting – 4 x 2.5T Swiftlift Anchors
Integrated Headwall Available in 1200 Range - IHS™
Available Lengths
2400
1200
100
Page 25
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
Range Weight
1.2m Long Weight
2.4m Long
1200 x 750 1550Kg 3100Kg
1200 x 900 1655Kg 3310Kg
1200 x 1200 1865Kg 3730Kg
SMALL BOX CULVERT 1200 Series (750-1200)
Australian Standards Reinforced Concrete Box Culverts AS1597.1-2010 - TMR Approved
• Load Class Roadway 0-2m Fill Cover
• Exposure B2
• For Placement Refer to Installation Guide
• Lifting – 4 x 2.5T Swiftlift Anchors
Precast Headwalls are available to suit the range.
Available Lengths
2400
1200
1480
1200
150
100
Page 26
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
RCBC Integrated Headwall 1200 Series
Australian Standards AS1597.1 - 2010
Multi-Cell
• Single Cell & Multi-Cell Application
• Exposure B2
• Monolithic Construction
• Weep Holes over Crown
350
125
Varies
1480
1200 or 2400
2150
600
Page 27
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
Rebated 15mm for Connector Plate
PRECAST INTERLOCKING KERB
End Cone
Interlocking Kerbs are used on roads for temporary lane
diversions /
construction sites.
Optional fencing can be installed using the loc
socket system for barrier mesh or
steel mesh fencing.
2 x 16mm S/S Thread Anchors 1 x 1.3T Swiftlift
Anchor
480
1000
40
200
480
8TM 300 Mesh
Connector Plate: 50x5 Gal Flat Bar
w/- 2 x 20mm Holes
Page 28
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
1650
2 x 1.3 Swift Lift Anchors Location Holes
2 x 20 Dia at 260 from ctrs
100 200
PRECAST 1650mm WHEELSTOP
• Manufactured to Aust. Std's AS/NZS2890.1:2004
• Bitumen surface mounting recommend 200 long x 16 Dia Galv Drive Pins x 2
• Concrete surface mounting recommend 16mm sleeve anchor or 12mm Hex Head Screw Bolt
Approx Weight 81Kg
Page 29
Head Office:
4 Quarry Road STAPYLTON QLD
PO Box 167 BEENLEIGH QLD 4207
P: (07) 3804 6622 F: (07) 3804 6699
e: [email protected] w: cmconcrete.com.au
Branch Office:
13-15 Enterprise Drive
BEAUDESERT QLD 4285
C-M Light Pole Base For Cross Falls – 1:2 & 1:4
• Maximum Pole Height: 10mtr • Concrete: N40 • TMR Drawing: 1393
Cross Fall Type Weight
1:2 Type 2 650Kg 1:4 Type 4 540Kg
560 700
1100
325 470
1100
Type 2
Type 4
860
1260
120
Plan View