- 68 - CONYERS, GA (800) 241-5652 APOPKA, FL (800) 432-1869 GOLDSBORO, NC (800) 426-9293 BLACKMER PUMPS FLANGE MOUNTING - DIRECT MOTOR DRIVE These small positive displacement pumps are ideal for filling cylinders and motor fuel tanks. They mount directly to a C-face motor & have built in “back to the tank” bypass valves. PUMP ONLY Item # Size Capacity LGF1E 1” 10 GPM LGF1PE 1” 15 GPM LGRLF1-1 1/4 1 1/4” 18 GPM Pumps, Bypass Valves BLACKMER PUMPS VB DRIVE STYLE LGF DRIVE STYLE DM DRIVE STYLE * Comes with one 2” flanged elbow. For two elbows, order TLGLF3C-2. Item # Size Capacity LGL1-1/4DM 1 1/4” 20 GPM LGL1-1/2DM 1 1/2” 30 GPM BLACKMER BY-PASS VALVES Differential bypass valves are designed to protect pumps and system components from excessive pressure damage. Weld flanges are available by special order. FISHER BY-PASS VALVES . Pump Pressure Adjust. Item # Size Size Setting Range N100A-10-2 1 1/4” 2”-3” 115 psi 50-150 psi N100A-12-2 1 1/2” 2”-3” 115 psi 50-150 psi N100-16-2 2” 4” 115 psi 50-150 psi Pump Pressure Adjust. Item # Size Size Setting Range Cap. BV-3/4 3/4” 1 1/4”-1 1/2” 95 psi 70-100 psi 50 GPM BV-1 1” 1 1/4”-1 1/2” 95 psi 70-100 psi 50 GPM BV-1 1/4 1 1/4” 1 1/2”-2” 95 psi 70-125 psi 125 GPM BV-1 1/2 1 1/2” 2”-3” 95 psi 70-125 psi 125 GPM BV-2-30 2” 3”-4” 30 psi 20-40 psi 225 GPM BV-2-55 2” 3”-4” 55 psi 41-70 psi 225 GPM BV-2-95 2” 3”-4” 95 psi 90-125 psi 225 GPM BY-PASS VALVES FLANGE MOUNTED PUMPS FOR BOBTAILS & TRANSPORTS Capacity is at 870 RPM and 50 psi differential pressure. Item # Inlet Aux. Inlet Outlet Capacity TLGLF3C* 3” flange 2” FNPT 2” FNPT 100 GPM TLGLF4B 4” flange 3” FNPT Dual 2” FNPT 379 GPM BASE MOUNTED - V-BELT DRIVE PUMP ONLY Capacity is at 640 RPM and 50 psi differential pressure. Item # Size Capacity LGLD2E 2” 67 GPM LGLD3E 3” 133 GPM LGLD4 4” inlet 3” outlet 270 GPM PUMP ASSEMBLY Pump, hubs, sheaves, high-torque triple V-belts and belt guard mounted on a common base, ready to accept a standard NEMA motor. Capacity at 640 RPM and 50 psi differential pressure. Item # Size Capacity LGLD2E-VB 2” 67 GPM LGLD3E-VB 3” 133 GPM LGLD4-VB 4” inlet 3” outlet 270 GPM PUMP ASSEMBLY Pump, coupling and coupling guard, mounted on a common base, ready to accept a standard NEMA motor. BRACKET MOUNTING - DIRECT MOTOR DRIVE These durable motor speed pumps offer capacities up to 35 GPM and are ideal for motor fueling, multiple station cylinder filling and a variety or small transfer jobs. They are designed for foot mounting to a common base plate. PUMP ONLY Item # Size Capacity LGL1-1/4 1 1/4” 20 GPM LGL1-1/2 1 1/2” 30 GPM LDF1 SERIES DISPENSER PUMPS Similar to the LGF1 Series, but these are assembled with left-hand rotation which will allow them to retrofit in place of Corken C Series pumps. These pumps require an external bypass valve. Item# Size Capacity LDF1A 1” 10 GPM LDF1PA 1” 15 GPM * To include a switch with the assembly, add an “A” suffix to the item #. (LGFIE-101A) LGF1 SERIES w/ 115/230V Motor Item # * Size HP Capacity LGF1E-101 1” 1 10 GPM LGF1PE-151 1” 1 1/2 15 GPM LGRLF-151 1 1/4” 1 1/2 18 GPM H
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
- 68 -
CONYERS, GA (800) 241-5652APOPKA, FL (800) 432-1869
GOLDSBORO, NC (800) 426-9293
BLACKMER PUMPS
FLANGE MOUNTING -DIRECT MOTOR DRIVEThese small positive displacement pumpsare ideal for filling cylinders and motor fueltanks. They mount directly to a C-facemotor & have built in “back to the tank”bypass valves.
* Comes with one 2” flanged elbow. For two elbows, order TLGLF3C-2.
Item # Size Capacity
LGL1-1/4DM 1 1/4” 20 GPM
LGL1-1/2DM 1 1/2” 30 GPM
BLACKMER BY-PASS VALVESDifferential bypass valves are designed toprotect pumps and system componentsfrom excessive pressure damage. Weldflanges are available by special order.
FLANGE MOUNTED PUMPSFOR BOBTAILS & TRANSPORTSCapacity is at 870 RPM and 50 psidifferential pressure.
Item # Inlet Aux. Inlet Outlet Capacity
TLGLF3C* 3” flange 2” FNPT 2” FNPT 100 GPM
TLGLF4B 4” flange 3” FNPT Dual 2” FNPT 379 GPM
BASE MOUNTED - V-BELT DRIVEPUMP ONLYCapacity is at 640 RPM and 50 psidifferential pressure.
Item # Size Capacity
LGLD2E 2” 67 GPM
LGLD3E 3” 133 GPM
LGLD4 4” inlet 3” outlet 270 GPM
PUMP ASSEMBLYPump, hubs, sheaves, high-torque tripleV-belts and belt guard mounted on acommon base, ready to accept astandard NEMA motor. Capacity at 640RPM and 50 psi differential pressure.
Item # Size Capacity
LGLD2E-VB 2” 67 GPM
LGLD3E-VB 3” 133 GPM
LGLD4-VB 4” inlet 3” outlet 270 GPM
PUMP ASSEMBLYPump, coupling and coupling guard,mounted on a common base, ready toaccept a standard NEMA motor.
BRACKET MOUNTING -DIRECT MOTOR DRIVEThese durable motor speed pumps offercapacities up to 35 GPM and are idealfor motor fueling, multiple station cylinderfilling and a variety or small transfer jobs.They are designed for foot mounting toa common base plate.
PUMP ONLYItem # Size Capacity
LGL1-1/4 1 1/4” 20 GPM
LGL1-1/2 1 1/2” 30 GPM
LDF1 SERIESDISPENSER PUMPS
Similar to the LGF1 Series, but these are assembled with left-hand rotation which will allow them to retrofit in place of Corken C Series pumps. These pumps require an external bypass valve.
Item# Size Capacity
LDF1A 1” 10 GPM
LDF1PA 1” 15 GPM
* To include a switch with the assembly, add an “A” suffix to the item #. (LGFIE-101A)
1 Included in Maintenance Kit. 2 Discontinued 'D' and 'C' models shipped with a 4-vane rotor. The current 6-vane rotor is fully interchangeable aslong as the slotted vanes (pn 092913) are used. 3 The current slotted vanes (pn 092913) may be used in either the 6-vane or 4-vane rotors.The discontinued solid vanes may be used in the 4-vane rotors ONLY. Always install the vanes with the slot facing the direction of rotation. † To fit the LGB1(P)C, LGF1(P)C use: Ref. No. 12-022902/022911 respectively, Ref. No. 20-032902, Ref. No. 26-382901, Ref. No. 27-042901,Ref. No. 28-920203, Ref. No. 28A & B-920230, Ref. No. 73A-908198, and Ref. No.108-832901/832905 respectively.Keep this parts list with Installation, Operation and Maintenance Instructions.
1 Included in Maintenance Kits and Rebuild Kits2 Included in Rebuild Kits.
— Kit - Rebuild LGL(F)1.5(A) [8 Vane] — 899078
Note: Earlier model pumps used taper pins, which are no longer required.Ref. No. 73A: Earlier versions of these pumps may use a 1/4” plug (pn 908198) or 1/2” plug (pn 908215).Keep this parts list with Installation, Operation and Maintenance Instructions.The following applies to LG(R)LF pump models only: 3 Use one outboard 4 Use four outboard 5 Use none.
1 Included in Maintenance Kit and Rebuild Kit 2 Included in Rebuild Kit The following applies to double end shaft pump models LGLD2E, TLGLD2E, LGLD3E & TLGLD3E: 3 Use Two 4 Use None 5 Double-Ended Rotor & Shaft. 6 Pump models before 1995 require key 184407. Keep this parts list with Installation, Operation and Maintenance Instructions.
1 Included in Maintenance Kit and Rebuild Kit ** NOTE: Mechanical Seal Ref. No. 153 is only sold as a complete assembly. Ref. Nos. 153A, 153B & 153C are not available as separate replacement parts. OPTIONAL HYDRAULIC MOTOR ADAPTER PARTS
Ref. No. Part Name Parts Per Pump
Size 2 Part No.
Size 3 Part No.
See Below Hydraulic Motor Adapter Kit * See Below 894425 895140 26A Gasket- Hydraulic Motor Adapter 1 383940 381817 28A Capscrew – Hydraulic Motor Adapter / Head 4 / 6 920369 920369
76A Grease Relief Fitting 1 701992 701992 135 Hydraulic Motor Adapter – SAE A Flange 1 041827 041831
135A Capscrew – Adapter / Motor 2 920510 920510 * Hydraulic Motor Adapter Kits shipped prior to Spring 2002 were of a two piece design – refer to page 206-C00.
1 Included in Maintenance Kit and Rebuild Kit ** NOTE: Mechanical Seal Ref. No. 153 is only sold as a complete assembly. Ref. Nos. 153A, 153B & 153C are not available as separate replacement parts. Use the table below to determine the proper parts for each model.
LGLD4A and LGL4A Discontinued LGLD4 and LGL4 Ref. No
1 Included in Maintenance Kit and Rebuild Kit 2 Included in Rebuild Kit 3 Larger O-Ring introduced October 2002 4 Additional Parts Included in Maintenance Kit with R/V
Keep this parts list with Installation, Operation and Maintenance Instructions.
1 Included in Maintenance Kit and Rebuild Kit ** NOTE: Mechanical Seal Ref. No. 153 is only sold as a complete assembly. Ref. Nos. 153A, 153B & 153C are not available as separate replacement parts.
135A Capscrew – Adapter / Motor 2 920510 * Hydraulic Motor Adapter Kits shipped prior to Spring 2002 were of a two two piece design – refer to page 206-C00.
PUMP MODEL: TLGLF3C (CONTINUED)
- 80 -
CONYERS, GA (800) 241-5652APOPKA, FL (800) 432-1869
GOLDSBORO, NC (800) 426-9293
BLACKMER PARTS LIST PUMP MODEL: TLGLF4A DISCONTINUED MODEL: TLGLF4
(See Instructions 501-E00 for Installation, Operation and Maintenance)
1 Included in Maintenance Kit and Rebuild Kit 2 Included in Rebuild Kit 3 Larger O-Ring introduced October 2002 Keep this parts list with Installation, Operation and Maintenance Instructions
LOCKNUT TOOL
Discontinued Models Parts availibility may be limited.
1 Included in Maintenance Kit and Rebuild Kit ** NOTE: Mechanical Seal Assy. (Ref. 153) is only sold as a complete assembly. Ref. Nos. 153A, 153B & 153C are not available as separate replacement parts.
TLGLF4 TLGLF4A
Interchangeability status w/TLGLF4A Interchangeability status w/TLGLF4 Part Name
PART NO. REF. PART NO. REF. Push Rods 122001 c 1 122005 c Liner 182039 c 2 182000 b Rotor & Shaft 262022 c 2 262024 a Bearing Locknut 903523 c 2 903541 c Bearing Lockwasher 903524 c 1 903542 c
1 Included in Maintenance Kit and Rebuild Kit 2 Included in Rebuild Kit Reference: a = Interchangeable, but requires new Bearing Locknuts PN 903541 and Bearing Lockwasher PN 903542. These are included whe ordering Rotor & Shaft PN 262024. b = Interchangeable but requires new push rods PN 122005. c = Not Interchangeable OPTIONAL HYDRAULIC MOTOR ADAPTER PARTS
Ref. No. Part Name
Parts Per
Pump Part No.
See Below Hydraulic Motor Adapter Kit * See
Below 892037
26A Gasket – Hydraulic Motor Adapter 1 381817
28A Capscrew – Hydraulic Motor Adapter / Head 6 920369
1 Included in Maintenance Kit and Rebuild Kit ** NOTE: Mechanical Seal Assy. (Ref. 153) is only sold as a complete assembly. Ref. Nos. 153A, 153B & 153C are not available as separate replacement parts.
TLGLF4 TLGLF4A
Interchangeability status w/TLGLF4A Interchangeability status w/TLGLF4 Part Name
PART NO. REF. PART NO. REF. Push Rods 122001 c 1 122005 c Liner 182039 c 2 182000 b Rotor & Shaft 262022 c 2 262024 a Bearing Locknut 903523 c 2 903541 c Bearing Lockwasher 903524 c 1 903542 c
1 Included in Maintenance Kit and Rebuild Kit 2 Included in Rebuild Kit Reference: a = Interchangeable, but requires new Bearing Locknuts PN 903541 and Bearing Lockwasher PN 903542. These are included whe ordering Rotor & Shaft PN 262024. b = Interchangeable but requires new push rods PN 122005. c = Not Interchangeable OPTIONAL HYDRAULIC MOTOR ADAPTER PARTS
Ref. No. Part Name
Parts Per
Pump Part No.
See Below Hydraulic Motor Adapter Kit * See
Below 892037
26A Gasket – Hydraulic Motor Adapter 1 381817
28A Capscrew – Hydraulic Motor Adapter / Head 6 920369
135 Hydraulic Motor Adapter – SAE A Flange 1 041829
135A Capscrew – Adapter / Motor 2 920510
* Hydraulic Motor Adapter Kits shipped prior to Spring 2002 were of a two piece design – refer to page 206-C00.
PUMP MODEL : TLGLF4B (CONTINUED)
H
- 84 -
CONYERS, GA (800) 241-5652APOPKA, FL (800) 432-1869
GOLDSBORO, NC (800) 426-9293
Hydraulic Drive SystemBlackmer’s HYDRIVE is a filly integrated hydraulic drive system. Atypical system includes a P.T.O., hydraulic pump, Hydrive cooler/controller, pump control valve, speed control valve, and mountinghardware. Hydraulic motor adapter kits are available to retrofitexisting Blackmer pumps for hydraulic drive operation. Each systemis factory engineered to fit your application.
KECF212EXPLOSION PROOFFLEXIBLE CONNECTORFor connecting wiring to motor ona pump unit so motor can be adjusted3/4” x 12”
COMPRESSORS MOTORS/STARTERS/SWITCHES
EXPLOSION PROOF MOTORSClass 1, Group D (60 cycle), 1750 RMP
Item # Approx. Liquid Transfer Rate Motor Size
LB161 90 GPM @ 780 RPM 7.5 HP
LB361 194 GPM @ 780 RPM 15 HP
LB601 351 GPM @ 790 RPM 25 HP
LB942 640 GPM @ 750 RPM 40 HP
BLACKMER OIL-FREECOMPRESSORSBlackmer offers a var iety of factoryassembled compressor packages to fit mostapplication requirements. Standard basemounted units are available in a variety ofstyles.
KRUG HAND PUMPOperates on the simple principle of theautomotive piston. Used for filling 20#cylinders, lift truck cylinders, etc.Inlet: 1” FNPTOutlet: 3/4” FNPTCapacity: 6 GPM at 40 strokes/min.
Item # Description
KHP Hand pump
K-HP-HK Connecting hose kit
KRUG VAPOR COMPRESSORS• Has LP Gas fueled engine (uses LP
being transferred as fuel)• 20 GPM transfer rate• 1/2” FNPT connections
Item # Description
K-VP-LP Compressor with LP engine
K-VP-HK Connecting hose kit
K16771B Replacement Compressor
K209870 3/4” replacement clutch
K3X927 Replacement pulley EXPLOSION PROOFSTARTERSClass 1, Group D (60 cycle)NEMA Type 3R, 7, & 9
MAGNETIC STARTERSare designed for full voltage starting ofmotors. All Bulletin 509 starters areequipped with manual reset overloadrelays and may be operated by remotepush button control. Protects motor fromthermal overload and undervoltage.Push button in cover.
M250TC METRIS VAPORMETERThis 3/4” meter will meter 400,000 BTUat 11” W.C. and up to 1,200,000 BTU of5 psig inlet pressure (max.). It has a directread CFU index. 2/3” connections.Larger sizes are available.
K1222Toggle switch only for KXS52C.
E4000 - NEPTUNEELECTRONIC REGISTERReplace your Bobtail’s Neptune orVeeder-Root mechanical register withthis easy to use electronic register.
• To install an E4000 on a 1 1/2” Neptune meter, use a 201072-0011 1/2” adaptor plate.
Designed for use where remote control isnot required and where undervoltageprotection is not needed. The motor isstarted at full line voltage. Thermal typeoverload protection is provided. START/STOP push buttons in cover.
Item # Size Voltage Phase Max HP
115V 230V 460V
B609AHX 0 115/230 1 1 2 --
B609BHX 1 115/230 1 2 3 --
B609XHX 1P 115/230 1 3 5 --
B609AHW 0 230/460 3 -- 3 5
B609BHW 1 230/460 3 -- 7 1/2 10
Class 1, Group D (60 Cycle) NEMA Type 3R, 7 and 9
B800H-2HA7REMOTE PUSH BUTTONSTATIONProvides remote operation of magneticstartersClass 1, Group D (60 Cycle) NEMA Type3R, 7 and 9
KXS52C OFF/ON SWITCHFor use with 1 and 1-1/2 HP explosionproof motors.
Class 1, Group D (60 Cycle) NEMA
Type 3R, 7 and 9
EPSON SLIP PRINTERTM-U295-071
METER SEALS
Item # Description
163-057-510 18” Seal Wire
163-057-510S 18” Seal Wire with lead seals
NEPTUNE CORIOLIS MASSFLOW LIQUID METERSFor bulk plants and bobtails. The Coriolisreduces LP Gas under-measurement, andcompared to traditional mechanical flowmeters, the Coriolis offers better accuracywith higher flow rates over a longerservice life. When combined with theNeptune E4000 Register, the Coriolisallows an upgrade path not obtainablewith competitive electronic transactionmanagement systems. Featureselectronic temperature compensationand the availability of combining withhand helds. Available in sizes from 12 -70 GPM.
H
- 86 -
CONYERS, GA (800) 241-5652APOPKA, FL (800) 432-1869
GOLDSBORO, NC (800) 426-9293
Neptune & Liquatech Meter PartsMETER PARTS
NEPTUNE/LIQUA-TECH METER PARTS
DESCRIPTION PART #
3/4” and 1” Meter 3/4” 1”Gasket, Main Case L4861-016 L4861-016