www.syxthsense.com BACnet Building Control Device Range Controllers, IOs and Measurements via BACnet® Interface BACnet Solutions for All Types of Applications - Keeping in Touch with the Future • Extensive Range of BACnet Field Devices and BACnet Controllers supporting BACnet IP and BACnet MS/TP • Support for Who-Is and Who-Has commands; allows MS/TP and IP devices to be discovered • Easy points discovery on MS/TP Field Devices and BACnet IP Controllers; Fast and Effective Engineering • Cost Effective BACnet Client Solutions for Integrating BACnet IP and BACnet MS/TP at the Controller Level • Supports Analogue Input, Analogue Output, Analogue Value, Binary Input, Binary Output, Multistate Input and Multistate Value Objects on SDC; plus BACnet schedule on DDC4200 Controllers • BACnet MS/TP Sensor Measurements include Temperature, Humidity, Occupancy, CO2, LUX Level, Resistive, NTC10 and Volt-Free Signals plus additional Inputs and Outputs for Cost Effective Engineered Solutions Modbus is registered trademark of Modbus IDA. JACE is a trademark of Tridium Inc. BACnet is registered trademark of ASHRAE. SYXTHSENSE BACNET SOLUTIONS - NETWORK EXAMPLES CDR BACnet CO2, %rH and Temperature Sensor BACnet MS/TP Client Examples: SyxthSense SDC-20G/32G Kieback& Peter DDC420/DDC4200 EasyIO FG20/FG32 Trend IQ4NC BACnet Client Tridium JACE BACnet MS/TP RS485 Communication BACNET ROOM SENSORS AND MEASUREMENT SOLUTIONS, BACNET MS/TP IO-MODULES AND CONTROLLERS BACNET ROOM INTERFACES CDR-LCD BACnet CO2 and Temp Transmitter w/ Display CDR-RH-SP BACnet CO2 , Temp and Humidity Transmitter with Setpoint RHR BACnet Humidity and Temp Module with Push Button TER BACnet Temperature Transmittter with extra Inputs and Outputs TER-SP BACnet Temp Transmitter with Active Setpoint and Controls BACnet MS/TP BACnet IP Clients Examples: SyxthSense SDC-20G/32G Kieback& Peter DDC4200 EasyIO FG20/FG32 Tridium JACE BAC-DIO4 BACnet Digital Input and Output Modules BAC-IO9 BACnet Input and Output Module SDC-20C Programmable Zone Controller (20 I/Os) BAC-RI Modbus Room Interface Module BAC-RI2 Modbus Room Interface Module EXAMPLE OF BACNET DEVICE AND POINT DISCOVERY ON THE MS/TP DEVICES INTEGRATING BACNET DEVICES TO THE BACNET SDC/20G/32G/FG20/FG32 CLIENT - HTML5 GRAPHICS ON THE PLANT ROOM CONTROLLER LEVEL WITH FULL SCALE BACNET IMPLEMENTATION
2
Embed
BACnet Building Control Device Range - · PDF file BACnet Building Control Device Range Controllers, IOs and Measurements via BACnet® Interface BACnet Solutions for All Types of Applications
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
www.syxthsense.com
BACnet Building Control Device RangeControllers, IOs and Measurements via BACnet® Interface
BACnet Solutions for All Types of Applications - Keeping in Touch with the Future• Extensive Range of BACnet Field Devices and BACnet Controllers supporting BACnet IP and BACnet MS/TP• Support for Who-Is and Who-Has commands; allows MS/TP and IP devices to be discovered
• Easy points discovery on MS/TP Field Devices and BACnet IP Controllers; Fast and E� ective Engineering• Cost E� ective BACnet Client Solutions for Integrating BACnet IP and BACnet MS/TP at the Controller Level• Supports Analogue Input, Analogue Output, Analogue Value, Binary Input, Binary Output, Multistate Input and
Multistate Value Objects on SDC; plus BACnet schedule on DDC4200 Controllers• BACnet MS/TP Sensor Measurements include Temperature, Humidity, Occupancy, CO2, LUX Level, Resistive,
NTC10 and Volt-Free Signals plus additional Inputs and Outputs for Cost E� ective Engineered Solutions
Modbus is registered trademark of Modbus IDA. JACE is a trademark of Tridium Inc. BACnet is registered trademark of ASHRAE.
BACNET ROOM SENSORS AND MEASUREMENT SOLUTIONS, BACNET MS/TP IO-MODULES AND CONTROLLERS
BACNET ROOM INTERFACES
CDR-LCDBACnetCO2 and TempTransmitter w/Display
CDR-RH-SP BACnet CO2 , Temp andHumidityTransmitterwith Setpoint
RHR BACnetHumidity andTempModule withPush Button
TER BACnetTemperatureTransmittterwith extraInputs andOutputs
TER-SP BACnet Temp Transmitterwith Active Setpoint and Controls
BACnet MS/TP
BACnet IP Clients
Examples:SyxthSense SDC-20G/32GKieback& Peter DDC4200EasyIO FG20/FG32Tridium JACE
BAC-DIO4BACnetDigital Inputand OutputModules
BAC-IO9BACnetInput and Output Module
SDC-20C ProgrammableZone Controller (20 I/Os)
BAC-RIModbusRoom InterfaceModule
BAC-RI2ModbusRoom InterfaceModule
EXAMPLE OF BACNET DEVICE AND POINT DISCOVERY ON THE MS/TP DEVICES
INTEGRATING BACNET DEVICES TO THE BACNET SDC/20G/32G/FG20/FG32 CLIENT - HTML5 GRAPHICS ON THE PLANT ROOM CONTROLLER LEVEL WITH FULL SCALE BACNET IMPLEMENTATION
Physical IOs 3 x Analogue 0..10Vdc,1 x RI, 1 x DI, 2 x DO
3 x Analogue 0..10Vdc,1 x RI, 1 x DI, 2 x DO
3 x Analogue 0..10Vdc,1 x RI, 1 x DI, 2 x DO
3 x Analogue 0..10Vdc,1 x RI, 1 x DI, 2 x DO
SyxthSense offers a comprehensive range of BACnet MS/TP sensors and measurement inter-faces. The BACnet protocol allows robust meas-urement readings, and interfacing to wide range of signals. For any questions on our range of available BACnet sensors please contact www.syxthsense.com or our sales department.
SyxthSense Ltd 3 Topsham UnitsDart Business Park Topsham ExeterEX3 0QH United Kingdom
Note: RI = Resistive Input, DI = Digital Input, AO = Analogue Output, DO = Digital Output
Note 1: The network design is important for reliable communications on any protocol, or BMS. SyxthSense is pleased to supply its preferred cable types for BACnet MS/TP and can advise on the network design as required. Using the correct cables for BACnet from SyxthSense and correct 0V referencing is a great way to reduce field issues.Note 2: Pulse reading register is volatile; separate back-up battery or intelligent BACnet client is required.
Note: UI = Universal Input, DO = Digital Output, UO = Universal Output, AO = Analogue Output, RO = Relay OutputNote: BACnet Objects; AI = Analogue Input, AO =Analogue Output, AV = Analogue Value, BI = Binary Input, BO = Binary Output, MSI = Multistate Input, MSO = Multistate Output Objects, MVV = Multistate Value, SC = Schedule Object, TL = Trend Log