Top Banner
Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and Technology (NUST)
16

Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.

Dec 24, 2015

Download

Documents

Wesley Glenn
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.

Automated DNA Sequencing

LECTURE 7:

Biotechnology; 3 Credit hours

Atta-ur-Rahman School of Applied Biosciences (ASAB)National University of Sciences and Technology (NUST)

Page 2: Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.

Automated DNA Sequencing

Page 3: Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.

Introduction

• Fluorescence based cycle sequencing system is an extension and refinement of Sanger dideoxy sequencing.

It consist of following steps

1. Template preparation 2. Cycle sequencing 3. Purification after cycle sequencing4. Capillary electrophoresis5. Data analysis

Page 4: Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.

Introduction

• Like Sanger sequencing, fluorescence based cycle sequencing requires

• a DNA template, • a sequencing primer, • a thermal stable DNA polymerase, • nucleotides (dNTPs), • dideoxynucleotides (ddNTPs), • and buffer.

• It uses fluorescent dyes to label the extension products and the components are combined in a reaction

Page 5: Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.
Page 6: Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.

Labeling of DNA

• Automated cycle sequencing procedures incorporate fluorescent dye labels using

1. Dye labeled dideoxynucleotide triphosphates (dye terminators)

2. Dye labeled primers (dye primers)

• Both chemistries use four different dyes

Page 7: Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.

Dye Terminator Chemistry

• With dye terminator chemistry, each of the four dideoxynucleotide terminators is tagged with a different fluorescent dye

• One reaction is performed, containing the enzyme, nucleotides, and all dye-labeled dideoxynucleotides

• The products from this reaction are injected into one capillary

Page 8: Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.

Dye Terminator Chemistry

Page 9: Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.

Dye Primer Chemistry

• With dye primer chemistry, four separate tubes of sequencing primer are each tagged with a different fluorescent dye.

• Four separate reactions are performed, each containing the enzyme, nucleotides

• Specific dye labeled sequencing primer, and either A, C, G, or T dideoxynucleotides

• The products from these four reactions are then combined and injected into one capillary

Page 10: Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.

Dye Primer Chemistry

Page 11: Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.

Detection of Resolved Fragments

Page 12: Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.

Detection of Resolved Fragments

Page 13: Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.

Detection of Resolved Fragments

Page 14: Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.

Detection of Resolved Fragments

Page 15: Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.

Fluorescent sequencing compared with radioactive sequencing

Page 16: Automated DNA Sequencing LECTURE 7: Biotechnology; 3 Credit hours Atta-ur-Rahman School of Applied Biosciences (ASAB) National University of Sciences and.

Short Gun Sequencing