Address - LOT 725 SELKIRK ROAD Suburb - SERPENTINE SHIRE OF SERPENTINE / JARRAHDALE PROPOSED DWELLING & ANCILLARY ACCOMMODATION Project Name Project Address Revision: D Job No. J002501 @A2 Client: LOUBSER NOTES THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT SPECIFICATION, REPORTS, CONTRACTS AND DRAWINGS. Scale: Sheet Date: MAR 2016 Drn by: Chk by: Drawing: ANCILLARY FLOOR PLAN Suite 14, 755 Albany Hwy East Victoria Park WA 6101 Tel | +61 8 9355 5484 Web | www.approvalsbydesign.com.au © COPYRIGHT 720 2440x2170 SLIDERS 1372 x 1810 772 x 1210 OBS 1372 x 1810 2400x2410 SD 2400x930 OP'NG 720 2400x930 OP'NG 870 2400 HIGH BI-FOLD 820 TF 720 820 LINEN W.M. PROV 4,400 9,690 14,090 3,280 4,430 4,090 11,800 4,400 9,230 13,630 1,240 780 3,370 2,910 5,520 1,460 1,060 E-07 5 E-08 5 E-05 5 E-06 5 PTY WIR KITCHEN ENTRY RAKING CEILING RAKING CEILING LIVING / DINING BED2 GAMES MASTER BED ALFRESCO TIMBER DECK @-80mm VERANDAH 2 TIMBER DECK @-80 VERANDAH 1 TIMBER DECK @-80 ANCILLARY FLOOR AREA 119.93m² STORE AREA 8.75m² VERANDAH 1 AREA 25.99m² VERANDAH 2 & DECK AREA 50.30m² ALFRESCO AREA 15.51m² CARPORT AREA 37.21m² CARPORT TIMBER DECK @ -80 TIMBER DECK @ -80 TIMBER DECK @ -80 RAKING CEILING RAKING CEILING RAKING CEILING RAKING CEILING CEILING @2575 AFL CEILING @2575 AFL CEILING @2575 AFL CEILING @2575 AFL CEILING @2800 AFL CEILING @2800 AFL CEILING @2800 AFL CEILING @2800 AFL CEILING @2800 AFL RAKING CEILING RAKING CEILING 1286 x 970 OBS 820 TF 820 720 620 2x820 TF 1st 820 FLUMED R/HOOD T L'DRY ENS BATH RETAINING WALL REFER TO ENGINEER SPECS 6x180=1080 STEPS REFER TO ENGINEER SPECS C.L. 2560 ABOVE CARPORT FLOOR F.L. 1000mm EXPOSED TIMBER PERIMETER BEAM 125x125 TIMBER POST 1050 HIGH BALUSTRADE AS SELECTED TO ENGINEER SPECS RETAINING WALL REFER TO ENGINEER SPECS TIMBER STAIRS REFER TO ENGINEER SPECS TIMBER STEPS REFER TO ENGINEER SPECS STORE 3.22m x 3.50m 3.00m x 3.19m 2.88m x 3.19m 8.61m x 4.25m 3.50m x 4.43m 5.25m x 4.68m 5.25m x 4.74m 6.10m x 6.10m SHELVING SHELF & RAIL SHELF & RAIL bath & shr 125x125 TIMBER POST 125x125 TIMBER POST 125x125 TIMBER POST EXPOSED TIMBER PERIMETER BEAM EXPOSED TIMBER PERIMETER BEAM 1050 HIGH BALUSTRADE AS SELECTED TO ENGINEER SPECS 1.50m x 5.34m 2400 2400 2400 2560 2400 2650 2,800 3,340 250 624 F.L. 00c C.L. 2800 + PLATE GROUND LEVEL SHEET METAL ROOF @20°49' CEDAR BOARD CLADDING GROUND LEVEL 2560 3274 TIMBER STAIRS REFER TO ENGINEER SPECS 1050 HIGH BALUSTRADE AS SELECTED TO ENGINEER SPECS TIMBER FRAMED FLOOR CONSTRUCTION TO BE IN ACCORDANCE WITH A.S. 1884 REFER TO ENGINEER DETAILS FOR SUB FLOOR MEMBER SIZES & POSITION 125x125 TIMBER POST BI-FOLD DOOR BELOW 2400 AFL 2650 AFL 3274 AFL EXPOSED TIMBER PERIMETER BEAM 2400 2560 1028 2400 1627 3480 3590 1028 2,800 1,000 2,560 F.L. 00c C.L. 2800 + PLATE SHEET METAL ROOF @20°49' CEDAR BOARD CLADDING OBSCURED GLAZING GROUND LEVEL NATURAL GROUND LEVEL GROUND LEVEL TIMBER DECK @ -80 F.L. 00mm CARPORT F.L. CARPORT C.L. min 150mm SUBFLOOR VENTILATION AS PER NCC 2014 VOLUME 2 PART 3.4.1. SHEET METAL ROOF @20°49' NATURAL GROUND LEVEL 1050 HIGH BALUSTRADE AS SELECTED TO ENGINEER SPECS 125x125 TIMBER POST TIMBER STAIRS REFER TO ENGINEER SPECS EXPOSED TIMBER PERIMETER BEAM 6x180=1080 STEPS REFER TO ENGINEER SPECS RETAINING WALL REFER TO ENGINEER SPECS TIMBER FRAMED FLOOR CONSTRUCTION TO BE IN ACCORDANCE WITH A.S. 1884 REFER TO ENGINEER DETAILS FOR SUB FLOOR MEMBER SIZES & POSITION 2400 2560 0 2143 2400 2560 2400 1114 3480 3590 2,800 1,000 2,560 F.L. 00c C.L. 2800 + PLATE NATURAL GROUND LEVEL SHEET METAL ROOF @20°49' CEDAR BOARD CLADDING OBSCURED GLAZING GROUND LEVEL NATURAL GROUND LEVEL TIMBER DECK @ -80 F.L. 00mm CARPORT F.L. min 150mm SUBFLOOR VENTILATION AS PER NCC 2014 VOLUME 2 PART 3.4.1. CARPORT C.L. SHEET METAL ROOF @20°49' GROUND LEVEL 1050 HIGH BALUSTRADE AS SELECTED TO ENGINEER SPECS 125x125 TIMBER POST EXPOSED TIMBER PERIMETER BEAM 6x180=1080 STEPS REFER TO ENGINEER SPECS RETAINING WALL REFER TO ENGINEER SPECS TIMBER FRAMED FLOOR CONSTRUCTION TO BE IN ACCORDANCE WITH A.S. 1884 REFER TO ENGINEER DETAILS FOR SUB FLOOR MEMBER SIZES & POSITION 2400 2560 2143 0 2,800 3,332 F.L. 00c C.L. 2800 + PLATE GROUND LEVEL SHEET METAL ROOF @20°49' CEDAR BOARD CLADDING CEDAR BOARD CLADDING BARGE & CAPPING CEDAR BOARD INFILL min 150mm SUBFLOOR VENTILATION AS PER NCC 2014 VOLUME 2 PART 3.4.1. TIMBER DECK @ -80 125x125 TIMBER POST EXPOSED TIMBER PERIMETER BEAM TIMBER FRAMED FLOOR CONSTRUCTION TO BE IN ACCORDANCE WITH A.S. 1884 REFER TO ENGINEER DETAILS FOR SUB FLOOR MEMBER SIZES & POSITION 1:100 BC 2 of 4 1. ANCILLARY FLOORPLAN 1:100 E-05 ANCILLARY ELEVATION 5 1:100 E-06 ANCILLARY ELEVATION 6 1:100 E-08 ANCILLARY ELEVATION 8 1:100 E-07 ANCILLARY ELEVATION 7 1:100 OCM084.2.07.17