Top Banner
8

CUSTOM · refer to construction detail sheet & engineer certified details refer to engineers tie down details ... refer to slab setout plan for slab, plumbing pre-lay and wet area

Apr 17, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: CUSTOM · refer to construction detail sheet & engineer certified details refer to engineers tie down details ... refer to slab setout plan for slab, plumbing pre-lay and wet area
Page 2: CUSTOM · refer to construction detail sheet & engineer certified details refer to engineers tie down details ... refer to slab setout plan for slab, plumbing pre-lay and wet area
Page 3: CUSTOM · refer to construction detail sheet & engineer certified details refer to engineers tie down details ... refer to slab setout plan for slab, plumbing pre-lay and wet area
Page 4: CUSTOM · refer to construction detail sheet & engineer certified details refer to engineers tie down details ... refer to slab setout plan for slab, plumbing pre-lay and wet area
Page 5: CUSTOM · refer to construction detail sheet & engineer certified details refer to engineers tie down details ... refer to slab setout plan for slab, plumbing pre-lay and wet area

BUILDING CONTRACTOR N° 12788Level 1, 42 Cedric Street, Stirling WA 6021Phone (08) 6144 1000 Fax (08) 6144 1004

© Copyright 2017 AVELING DEVELOPMENTS

WANNEROO

Scale:

Date Drn:

Sales:Site:

Drwg: U2 FLOOR PLAN

LOT 164 #19 ALLINSON DRIVE1:100

PS/IVY

CONTRACTS

JBES

KINYUAClient:Drn By:Check:

Local Authority:

06Sheet #:

JobNo:

17/09/18G1353

01Rev:

Rev: Date: Amendment: Init:

Map Ref: StreetSmart® - 282 22/73

SIMPRE-CON VO - PLANNING REQUIREMENTS04/04/1901020304050607

GIRRAWHEEN

CUSTOM

OWNER..................................... DATE...........................

OWNER..................................... DATE...........................

BUILDER................................... DATE...........................

S:\Drafting\Working Drawings\Aveling Developments\G1353 Kinyua & Migwi\Archicad Files\Pending VO\G1353 Kinyua & Migwi - Site Plan.pln

PLANNINGDRAWINGS

AVELING HOMES HAS THE COPYRIGHTPROTECTION ON ANY DRAWINGS ORPRELIMINARY DESIGNS THAT ARE ISSUEDTO CLIENTS. THESE PLANS CANNOT BECOPIED OR UTILISED BY ANYONE OTHERTHAN AVELING HOMES PTY. LTDWITHOUT THE EXPRESS PERMISSION OFAVELING HOMES PTY. LTD.

Last

acce

ssed

: Sim

onB

on 4/

04/20

19

FIXING CARPENTER NOTEPROVIDE GALLOWS BRACKETSUPPORT TO SHELVES OVER1800MM LONG (MAX. 1800cts)

ALL SHELVES 450 DEEP (U.N.O.)

HANG RAIL CENTRE TO BE 250MMOFF WALL/ BACK OF SHELF.

WIR/ROBE:SHELF & RAIL AT 1800MM A.F.L.

PANTRY: 4 SHELVESTOP SHELF AT 1800MM A.F.L.BOTTOM SHELF AT 600MM A.F.L.EQ. SPACE SHELVES BETWEEN

LINEN: 4 SHELVESTOP SHELF AT 1800MM A.F.L.EQ. SPACE ALL SHELVES TO F.F.L.

BROOM:1 x SHELF AT 1800MM A.F.L.

PROVIDE DRAFTPROOF SEAL TOENTRY, GARAGE/ENTRY & LAUNDRYEXTERNAL DOORS WHEREAPPLICABLE

TOWEL RAILS FIXED AT 900MM A.F.L.

ROOF CARPENTER NOTEREFER TO ENGINEERS TIE DOWNDETAILS

REFER TO BUILDERS ROOFCARPENTER SPECIFICATION.

FIXING CARPENTER NOTEPROVIDE GALLOWS BRACKETSUPPORT TO SHELVES OVER1800MM LONG (MAX. 1800cts)

ALL SHELVES 450 DEEP (U.N.O.)

HANG RAIL CENTRE TO BE 250MMOFF WALL/ BACK OF SHELF.

WIR/ROBE:SHELF & RAIL AT 1800MM A.F.L.

PANTRY: 4 SHELVESTOP SHELF AT 1800MM A.F.L.BOTTOM SHELF AT 600MM A.F.L.EQ. SPACE SHELVES BETWEEN

LINEN: 4 SHELVESTOP SHELF AT 1800MM A.F.L.EQ. SPACE ALL SHELVES TO F.F.L.

BROOM:1 x SHELF AT 1800MM A.F.L.

PROVIDE DRAFTPROOF SEAL TOENTRY, GARAGE/ENTRY & LAUNDRYEXTERNAL DOORS WHEREAPPLICABLE

TOWEL RAILS FIXED AT 900MM A.F.L.

CLIENT NOTENOTED DIMENSIONS WILL TAKEPREFERENCE TO SCALE.

DIMENSIONS SHOWN ON PLANSARE TO BRICKWORK. INTERNALSPACES WILL ALTER IN SIZE TOACCOMODATE WALL FINISHES

H/FLEX TO ALL EXTERNALCEILINGS & EAVE LININGS U.N.O.

NUMBER AND SPACING OF RAINWATER PIPES IS APPROXIMATE &GOVERNED BY ROOF STRUCTURE& AT THE PLUMBERS DISCRETION.

ALL STRUCTURAL BEAMS INACCORDANCE WITH THEENGINEERS SIGNED DETAILSAND SPECIFICATIONS

BRICKLAYER NOTE6MM RODS & 3c OF LONGREACHBRICK TO TOP OF INTERNAL WALLSBETWEEN Z-Z.

EXTENT OF RENDER BETWEEN R-R.

REFER TO CONSTRUCTION DETAILSHEET & ENGINEER CERTIFIEDDETAILS

REFER TO ENGINEERS TIE DOWNDETAILS

ROOF CARPENTER NOTEREFER TO ENGINEERS TIE DOWNDETAILS

REFER TO BUILDERS ROOFCARPENTER SPECIFICATION.

(U.N.O.) UNLESS NOTED OTHERWISEON PLAN THE FOLLOWING SHALLAPPLY:

820M.F.

REM

OTE

CO

NTR

OL

SEC

TIO

NAL

DO

OR

W/-

PELM

ET

820

T.F.

16x

1610

15x1410

14x1110

25x2

721 S

D

770 W/- PELMETS/C

720720

2x F

H SL

DRS

(SOF

FIT

CEIL.

)

820

2x F

H SL

DRS

(SOF

FIT

CEIL.

)

820

16x

1610

1250

W D

HOBW

K @

25c

820

720 2x720

2x FH SLDRS(SOFFIT CEIL.)

920W DHOBWK @ 25c

KS

VBVB

GAS HWUREC. BOX

HPCANOPYR/HOOD

UBO

1525

BTH

PTY

TR

WM

DP

DP

DP

DP

DP

DP

DP

DP

DP

R

R

LIVING

O/ALL

W

PIER KITCHEN/DINING ENTRY PORCH

BED 3ROBEPASSAGEKITCHEN/DINING

BED 2

LINWIRMAIN SUITE WC PASSAGE

CAVMAIN SUITE PASSAGEMAIN SUITE

MAIN SUITE ENS L'DRY BATH ROBE BED 2

PIER

ALFRESCO O/ALL PIER PIER PIER

W

PIER PIER

GARAGESTORE

O/A

LL

CAV

WW

DR

GAR

AGE

OPE

NIN

GPI

ER

PIER

BED

3PO

RC

H

BATH

RO

BE

BED

2

PASS

AGE

PASS

AGE

RO

BE

BED

3PO

RC

H

ENTR

Y

GAR

AGE

GAR

AGE

PIER

PIER

DIN

ING

O/A

LL

SD

PIER

PIER

MAI

N S

UIT

E

PASS

AGE

ENS

PASS

AGE

L'D

RY/

BATH

WIR

/WC

ALFR

ESC

O O

/ALL

MAI

N S

UIT

EKI

TCH

EN

KITC

HEN

KITC

HEN

/LIV

ING

STO

RE

LIVI

NG

ALFR

ESC

O

SD

SD

FRDWREC

N

O/ALL

BED 3

PIER

PORCH

Z

Z

MH

LOADCNTR

BED

2BE

D 3LIN

DP

SHRSHR

SKYLIGHT

A A

2,600

4,600 3,950MIN. ACOUSTIC TREATMENT

5,640

630

540 1,000

1,300 190

34

12

PB

FC

FC

A/C UNIT ON 1100 x 600GRANO HARDSTAND

SPLIT SYSTEMWALL UNIT

FC

STANDARD 1c B'WORK TOADJ. GARAGE REFER UNIT 3

ACOUSTIC WALL - 1c B'WORK TOADJACENT LIVING REFER UNIT 3

110mm B'WORK

110mm 1c B'WORK W/ 13mmRENDER TO SUIT BCA REQ.EXTENT SHOWN DASHED

POINT OF ACOUSTIC REQUIREMENT

2c BRICKWORK

BOUNDARY LINE

FLASH PIERTO DETAIL

FLASH PIER TO DETAIL

ZER

O L

OT

LIN

E W

ALL

REF

ER T

O D

ETAI

L

NOTE:REFER TO SLAB SETOUTPLAN FOR SLAB, PLUMBINGPRE-LAY AND WET AREASETOUT

NOTE:PROVIDE SPLIT SYSTEM AIRCONDITIONING UNIT ASSPECIFIED

NOTE : SHADED AREA DENOTES BULKHEAD OR SUSPENDED CEILING BY CEILING FIXER AT HEIGHT NOMINATED

CUT BRICKS

WEDGEGUTTER

190W BWK ON'T' BAR LINTELAT 25c

EXTENT OFSECONDARY

COLOUR PAINTFINISH TORENDER

SHOWN DASHED

COMMON PARAPET WALL TO UNIT 1TO UNDERSIDE OF ROOF SHEETING

ACOUSTIC BRICKS REFERUNIT 1 FOR EXTENT

COMMON PARAPET WALL TO UNIT 2TO UNDERSIDE OF ROOF SHEETING

PORCHC.L.: 28c

B/PAVEDAT -100mm

MAIN SUITECARPET

BED 2CARPET

BED 3CARPET

ENTRYLAM

STOREC.L.: 28c

GRANOAT -100mm

GARAGEC.L.: 28c

GRANOAT -100mm

KITCHENC.L. : 31c+WP

LAM

WIR

ENSBATHL'DRY

WC

ALFRESCOC.L.: 28c

B/PAVE AT-100mm

LIN

RO

BER

OBE

LAM

LAM

GAS

T.O.F. -07c

T.O.F. -07c

905,

710

901,

250

901,

500

901,

090

9097

090

1,66

011

0

9029

01,

870

290

3,26

090

3,05

097

090

970

901,

660

110

2,40

014

03,

260

1,20

03,

390

2,44

016

0

9010

05,

510

10090

1,25

090

2,68

090

2,72

011

0

5,48

041

01,

250

902,

680

9030

090

2,44

049

04,

990

410

100

880

130

790

1,61

099

020

01,

610

630

12,9

90

902,

450

906,

310

9097

097

090

1,66

011

0

3,60

023

02,

710

903,

800

160

2,40

03,

600

2,80

04,

190

230

3,60

02,

710

9088

090

970

901,

660

270

390

3,21

039

02,

410

230

3,69

027

0

2,40

059

02,

721

289

NTB

2,80

04,

190

ZER

O L

OT

WAL

L O

/ALL

12,9

90

2,800 230 6,550 92090

600 3,270 230

2,080 390330

230 7,470 90 2,070 230 1,490 310

4,600 9,590 500

230 3,470 90 2,630 90 1,610 90 1,28090

920 90 3,870 230

230 3,470 2,910 90 3,800 90 3,370 90 550 90

230 3,470 90 2,270 90 1,500 90 2,760 90 600 2,770 230 500

14,690

2,080 2,520 230 3,470 90 2,010 290 1,910 290 470290310 230190

390 2,130

2,800 1,800 3,790 4,500 1,800

2,800 1,800 2,000 90 1,700 5,570 230 500

90 100 4,970 290 1,310 290310

230

790 1,410 600 690 1,110 2,000 7,590 190 310

14,690

2,40

03,

990

2,41

0

380D BULKHEAD AT2261H TO O'HEAD

CUPB'DS

DININGC.L.: 31c+WP

LAM

LIVINGC.L.: 31c+WP

LAM

ENERGY EFFICIENCY REQUIREMENTSCAVITY WALL INSULATION: NIL(Extent between markers X-X)LIVING CEILING INSULATION: R4.1GARAGE CEILING INSULATION: NILROOF INSULATION: NILDESIGN CHANGES: NILWINDOW GLAZING: SINGLE CLEARENERGY RATING COMPLETE: NO

LEGEND:

GF GROUND FLOORFF FIRST FLOORFL FLOOR LEVELCL CEILING LEVELRL REDUCED LEVELFFL FINISHED FLOOR LEVELAFL ABOVE FLOOR LEVELWP WALL PLATE

AF ALUMINIUM FRAMEMF METAL FRAMETF TIMBER FRAMEPL PRIVACY LOCKOBS OBSCURE GLASSDG DOUBLE GLAZINGDR DOUBLE REBATEGB GLAZING BARS

PB PLASTERBOARDFC FIBRE CEMENTVB VILLABOARD (FC)SC SKIM COAT(PLASTER)PF PAINT FINISHAT ACRYLIC TEXTURE

DP DOWNPIPESPRDR SPREADERRWH RAIN WATER HEAD NTB NOT TO BONDFW FLOOR WASTE

NOTE:CEILING 28c + WALL PLATE

UNLESS NOTED OTHERWISE.

METAL DECK ROOFAT 20°, EAVE 600MM

02c DOUBLE HEIGHT FACE BRICK FINISH TOEXTERNAL BWK UNLESS NOTED

OTHERWISE.

ID0202020202

AREAALFRESCOGARAGEPORCHPROPOSED RESIDENCESTORE

M²9.3533.761.67104.534.53153.84 m²

PERIM.13.0223.385.2250.568.67100.85 m

ID02

ROOFROOF AREA GF

M²160.42

PERIM.56.35

Page 6: CUSTOM · refer to construction detail sheet & engineer certified details refer to engineers tie down details ... refer to slab setout plan for slab, plumbing pre-lay and wet area
Page 7: CUSTOM · refer to construction detail sheet & engineer certified details refer to engineers tie down details ... refer to slab setout plan for slab, plumbing pre-lay and wet area