AIRTRONIC / AIRTRONIC MTroubleshooting and Repair Instructions
25211595190104.2009
Airtronic Orderno.
AirtronicD2,12V 252069050000AirtronicD2,24V 252070050000AirtronicD2Camper,12V 252326050000
Completepackage
AirtronicD2,12V 252115050000AirtronicD2,24V 252116050000
Air heater for diesel and petroloperating independently of the engine.
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 2
2
4
3
1
2
1Contents
ThislistofcontentsgivesyoupreciseinformationaboutthecontentsoftheTroubleshootingandRepairInstructions.
Introduction
Usetheindex,listofabbreviations,etc,tolookforaterm,technicalwordoranexplanationforanabbreviation.
Chapter Title Contents Page
Introduction • Foreword.................................................................................................................. 4• Accidentprevention.................................................................................................. 4• Specialtextstructure,presentationandpicturesymbols........................................... 4• Importantinformationbeforestartingwork................................................................ 4
Function and use Cutawayview............................................................................................................ 5• Descriptionoffunctions– Switchingon.......................................................................................................... 6– StartingtheAirtronic.............................................................................................. 6– StartingtheAirtronicM.......................................................................................... 6– Temperatureselectionwiththecontrolelement...................................................... 6– Controlinheatingmode......................................................................................... 6– Ventilatingmode.................................................................................................... 6– Switchingoff.......................................................................................................... 6
• Controlandsafetydevices........................................................................................ 7– Forcedshut-downforADRoperation..................................................................... 7– Emergencyshutdown–EMERGENCYOFF........................................................... 7
Technical data • Airtronic(fordiesel)................................................................................................... 8• AirtronicM(forpetrol)................................................................................................ 9• AirtronicM(fordiesel)........................................................................................ 10,11• Checkvalues– Testspeedfortheblower..................................................................................... 12– Resistan\cevalues............................................................................................... 12– Switchingvalue.................................................................................................... 12– Exhaustemissionspecification............................................................................. 12– Check“externaltemperaturesensor”................................................................... 12– Tableofvalues:“Externaltemperaturesensor”..................................................... 12
Troubleshooting • Whattocheckfirstincaseoffaults– Check.................................................................................................................. 13– Electricalcomponents.......................................................................................... 13–Measurebatteryvoltage....................................................................................... 13–Measuresvoltagesupply..................................................................................... 13– Checkswitch-onsignal........................................................................................ 13– Checkcontrolunit................................................................................................ 13
•Overviewoftheindividualtestequipmentandcontrolunits..................................... 14• Lockingthecontrolbox........................................................................................... 14• Cancelthecontrolboxlock..................................................................................... 14• Importantnotes(diagnosisofheaterswithmini-controller)....................................... 14• Testingdeviceforthecontroldevice........................................................................ 15• Faultdiagnosisusingthediagnosticunit........................................................... 15,16• FaultdiagnosisusingtheEDiTHdiagnosticstoolwithISOadapter.......................... 17• AirpressuresensordiagnosisusingEDiTHdiagnosticstoolandISOadapter.......... 18• FaultdiagnosisusingtheEDiTHdiagnosticstoolwithbasicadapter....................... 19• Faultdiagnosisusingthemoduletimer.................................................................... 20• FaultdiagnosisusingtheradioremotecontrolTP5................................................. 21• FaultdiagnosisusingtheEasyStartR+radioremotecontrolortheEasyStartTtimer............................................................................................... 22
• Faultcodetable...............................................................................................23–27
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 3
3
Introduction
7
6
5
1
Chapter Title Contents Page
Repair instructions • Repairinstructions.................................................................................................. 28• Alwaysobservethefollowingsafetyinstructionsbeforeworkingontheheater........ 28• Specialtool,AMPreleasetool................................................................................. 28• AssemblydrawingAirtronic/AirtronicM................................................................. 29• Repairstep1,removetheheatercover................................................................... 30• Repairstep2,dismantlecontrolbox,checkcontrolbox......................................... 30• Repairstep3,dismantleglowplug.......................................................................... 31• Repairstep4,renewlining...................................................................................... 31• Repairstep5,dismantlecombinationsensor(overheating/flamesensor............... 32• Repairstep6,installcombinationsensor(overheating/flamesensor)..................... 33• Repairstep7,dismantleheatexchanger/dismantlecombustionairfan................................................................................... 34
• Repairstep8,dismantlecombustionchamber........................................................ 35• Checkfuelsupply.................................................................................................... 36•Measuringthefuelquantity...................................................................................... 36
Circuit diagrams Overviewofthepartslistsandcircuitdiagrams........................................................... 37• PartslistcircuitdiagramsAirtronic/AirtronicM....................................................... 38• CircuitdiagramAirtronic/AirtronicM..................................................................... 39Thiscircuitdiagramisvalidforheaterswithonediagnosiscableandacontrolboxcableloomwichisfirmlyencapsulated.
• CircuitdiagramAirtronic/AirtronicM..................................................................... 40Thiscircuitdiagramisforheaterswith2diagnosticscableandwhosecontrolboxcableloomiswoundwithcabletape.
• Partslistcircuitdiagrams,controlunits.................................................................... 41• Circuitdiagramcontrolunits–part1....................................................................... 42• Circuitdiagramcontrolunits–part2....................................................................... 43• Circuitdiagramcontrolunits–part3....................................................................... 44• Circuitdiagramcontrolunits–part4....................................................................... 45• Circuitdiagramcontrolunits–part5....................................................................... 46• Circuitdiagramcontrolunits–part6....................................................................... 47• Circuitdiagramcontrolunits–part7....................................................................... 48• PartslistcircuitdiagramcontrolunitEasyStartR+/R/T........................................ 49• CircuitdiagramcontrolunitEasyStartR+(controlboxwith1diagnosticscable)...... 50• CircuitdiagramcontrolunitEasyStartR+(controlboxwith1diagnosticscable)...... 51• CircuitdiagramcontrolunitEasyStartR+(controlboxwith2diagnosticscable)...... 52• CircuitdiagramcontrolunitEasyStartR(controlboxwith1/2diagnosticscables). 53• CircuitdiagramcontrolunitEasyStartR(controlboxwith2diagnosticscables)...... 54• CircuitdiagramcontrolunitEasyStartR(controlboxwith1diagnosticscables)...... 55• CircuitdiagramcontrolunitEasyStartT(controlboxwith1diagnosticscable)........ 56• CircuitdiagramcontrolunitEasyStartT(controlboxwith2diagnosticscable)........ 57• PartslistcircuitdiagramsAirtronic/AirtronicM–ADR............................................ 58• CircuitdiagramAirtronic/AirtronicM–ADR.......................................................... 591encapsulateddiagnosticscableandcontrolboxcableloomfirmlyencapsulated
• CircuitdiagramAirtronic/AirtronicM–ADR.......................................................... 602diagnosticscablesandcontrolboxcableloomwithcabletape
• Partslistcircuitdiagrams,controlunits–ADR......................................................... 61• Partslistcircuitdiagrams,controlunits–EasyStartT–ADR................................... 61• Circuitdiagramcontrolunits–ADR......................................................................... 62• CircuitdiagramcontrolunitEasyStartT–ADR(controlboxwith1diag.cable)....... 63• CircuitdiagramcontrolunitEasyStartT–ADR(controlboxwith2diag.cable)....... 64
Service • Certification............................................................................................................. 65• Disposal.................................................................................................................. 65• ECDeclarationofConformity.................................................................................. 65• Representativesabroad.................................................................................... 66,67• Listofkeywords............................................................................................... 68,69• Listofabbreviations................................................................................................ 69
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 4
4
Special text structure, presentation and picture symbols
Specialtextformatsandpicturesymbolsareusedintheseinstructionstoemphasisedifferentsituationsandsubjects.Pleaserefertothefollowingexamplesfortheirmeaningsandappropriateaction.
Special text formats and presentations• Adot(•)indicatesalist,whichisstartedbyaheading.– Ifanindenteddash(–)followsa“dot”,thislistisasub-sectionoftheblackdot.
Picture symbols
Danger!Thisinformationpointsoutadangeroussituationforapersonand/ortheproduct.Failuretocomplywiththeseinstructionscanresultininjuriestopeopleand/ordamagetomachinery.
Caution!Thisinformationpointsoutadangeroussituationforapersonand/ortheproduct.Failuretocomplywiththeseinstructionscanresultininjuriestopeopleand/ordamagetomachinery.
Important information before starting work
Initial commissioning of the heater or functional test after a repair
• Afterinstallingtheheater,thewholefuelsupplysystemmustbecarefullyvented:pleaserefertoandfollowthevehiclemanufacturer’sinstructions.
• Duringtheheatertrialrun,allfuelconnectionsmustbecheckedforleaksandsecure,tightfit.
• Iffaultsoccurwhiletheheaterisrunning,useadiagnosticunittodetermineandcorrectthecauseofthefault.
1 IntroductionForeword
TheseTroubleshootingandRepairInstructionsareapplicabletotheheaterslistedonthetitlePage,totheexclusionofallliabilityclaims.Dependingontheversionorrevisedstatusoftheheater,theremaybedifferencesbetweenitandthesetroubleshootingandrepairinstructions.Theusermustcheckthisbeforecarryingouttherepairworkand,ifnecessary,takethedifferencesintoaccount.
Caution!Safety instructions for installation and repair!
ImproperinstallationorrepairofEberspächerheaterscancauseafireorresultpoisonousexhaustenteringtheinsideofthevehicle.Thiscancauseseriousandevenfatalrisks.
Theheatermayonlybeinstalledaccordingtothespecifica-tionsinthetechnicaldocumentsorrepairedusingoriginalsparepartsbyauthorisedandtrainedpersons.Installationandrepairsbyunauthorisedanduntrainedper-sons,repairsusingnon-originalsparepartsandwithoutthetechnicaldocumentsrequiredforinstallationandrepairaredangerousandthereforearenotpermitted.
Arepairmayonlybecarriedoutinconnectionwiththere-spectiveunit-relatedtechnicaldescription,installationinstruc-tions,operatinginstructionsandmaintenanceinstructions.Thisdocumentmustbecarefullyreadthroughbefore/duringinstallationandrepairandfollowedthroughout.Particularattentionistobepaidtotheofficialregulations,thesafetyinstructionsandthegeneralinformation.
Please note!
Therelevantrulesofsoundengineeringpracticeandanyinformationprovidedbythevehiclemanufactureraretobeobservedduringtheinstallationandrepair.Eberspächerdoesnotacceptanyliabilityfordefectsanddamage,whichareduetoinstallationorrepairbyunauthor-isedanduntrainedpersons.Compliancewiththeofficialregulationsandthesafetyinstruc-tionsisprerequisiteforliabilityclaims.Failuretocomplywiththeofficialregulationsandsafetyinstructionsleadstoexclu-sionofanyliabilityoftheheatermanufacturer.
Accident prevention
Generalaccidentpreventionregulationsandthecorrespond-ingworkshopandoperatingsafetyinstructionsaretobeobserved.
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 5
5
Cutaway view
1 Heaterimpeller 2 Controlbox 3 Combustionairfanimpeller 4 Glowplug 5 Cover 6 Heatexchanger 7 Combinationsensor(overheating/flamesensor) 8 Radioremotecontrol(mobileunit) 9 Radioremotecontrol(stationaryunit)10 Button11 Temperaturesensor(roomtemperature)12 Fusebracketwithmainfuseand“actuation”fuse13 Electricalmotor14 Fuelconnection15 Flangeseal
16 Combustionchamber17 Outlethood18 Combustionairhose19 Meteringpump20 Pot-typestrainer,installedinthedosingpump21 Outflow22 FlexibleexhaustpipeF= FreshairW= HotairA= ExhaustB= FuelV= Combustionair
Functionanduse2
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 6
6
Description of functions
Switching on
Whentheheaterisswitchedon,thecontrollampinthecon-trolunitlightsup.Theglowplugisswitchedonandthefanstartsatlowspeed.
fthereisstilltoomuchresidualheatintheheatexchangerfromwhentheheaterwaslastused,firstlyonlythefanstartsup(coldblowing).Oncetheresidualheathasbeencleared,theheaterstarts.
Starting Airtronic
Afterapprox.65secondsthefuelsupplystartsandthefuel/airmixtureinthecombustionchamberignites.Oncethecombinedsensor(flamesensor)hasdetectedtheflame,theglowplugisswitchedoffafter60seconds.Theheaterisnowinstandardoperation.
Starting Airtronic M
Afterapprox.60secondsthefuelsupplystartsandthefuel/airmixtureinthecombustionchamberignites.Aftertheflamesensorhasdetectedtheflame,theglowplugisswitchedoffafterapprox.90sec.Theheaterisnowinstandardoperation.Afteranother120seconds,theheaterhasreachedthe“POWER”stage(maximumfuelquantity,maximumfanspeed).
Temperature selection with the control element
Thecontrolcanbeusedtopreselectaninteriortemperature.Theresultingtemperaturecanbewithintherangeof+10°Cto+30°Canddependsontheselectedheater,onthesizeofthespacetobeheatedandontheprevailingoutdoortem-perature.Thesettingtobeselectedatthecontrolisanempiricalvalue.
Control in the heating mode
Duringtheheatingmode,theroomtemperatureorthetem-peratureofthesuckedinheatingairisconstantlymeasured.Ifthetemperatureishigherthanthetemperatureselectedonthecontrolelement,theheaterstartstoregulateitsoutput.Thereare4controlstagessothattheoutflowofheatpro-ducedbytheheatercanbeadjustedfinelytotheheatingrequirements.Fanspeedandfuelquantitycorrespondtotheparticularcontrolstage.Ifthesettemperatureisstillexceededinthesmallestcontrolstage,theheatergoestothe“OFF”stagewiththefanrunningonforapprox.4minutestocooloff.Thefanthencontinuesrunningatminimumspeed(circulationmode)untiltherestartorisswitchedoff(freshairmodewithexternaltemperaturesensor).
Ventilating mode
TheEasyStartR+andEasyStartTcontrolunitsandthemini-controllercanbeusedtoactivatethe„Ventilate“function.The„Heat/Ventilate“switchisalsorequiredforthemodulartimerandcontroldevicewhereby,forfanmode,the„Heat/Ventilate“switchmustbepressedfirstandthentheheaterswitchedon.Theblowerrunsatmaximumspeedinfanmode.
Switching off
Whentheheaterisswitchedoff,thecontrollampgoesoffandthefuelsupplyisswitchedoff.Thefanrunsonforapprox.4minutestocooldown.Whilethefanisrunningon,theglowplugisswitchedonforapprox.40secondstoclean.Specialcase:Ifnofuelhasbeensuppliedoriftheheaterisinthe“OFF”stageuntilitisswitchedoff,theheaterisstoppedwithoutanyafterrunning.
Functionanduse2
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 7
7
Forced shut-down for ADR operation
Invehiclesforthetransportofdangerousgoods(e.g.tankertrucks),theheatermustbeswitchedoffbeforethetruckdrivesintoadangerarea(refinery,petrolstation,etc.).Failuretocomplyresultsintheheaterautomaticallyswitchingoffif:• thevehicleengineisswitchedoff,• anadditionalunitisstartedup(auxiliarydriveforunloadingpump,etc.),
• avehicledoorisopened(ADR99regulation,onlyinFrance).Thefanthenrunsonformax.40seconds.
Functionanduse2
Emergency shutdown – EMERGENCY OFFIfanemergencyshutdown–EMERGENCYOFF–isre-quiredduringoperation,executethefollowing:• Switchtheheateroffatthecontrolelementor• removethefuseor• disconnecttheheaterfromthebattery.
Control and safety devices
• Iftheheaterdoesnotignitewithin90secondsafterstartingthefuelpump,thestartisrepeated.Iftheheaterstilldoesnotigniteafteranother90secondsofpumpingfuel,theheaterisswitchedoff,i.e.thefuelsupplyisoffandthefanrunsonforapprox.4minutes.
• Iftheflamegoesoffbyitselfduringoperation,theheaterisrestarted.Iftheheaterdoesnotignitewithin90secondsafterthefuelpumphasstarted,orignitesandgoesoffagainwithin15minutes,theheaterisswitchedoff,i.e.thefuelsupplyisoffandthefanrunsonforapprox.4minutes.Thisstatuscanberemediedbybrieflyswitchingoffandonagain.Donotrepeattheswitchingoff/onroutinemorethantwice.
• Inthecaseofoverheating,thecombinedsensor(flamesensor/overheatingsensor)triggers,thefuelsupplyisinterruptedandtheheaterswitchedoff.Oncethecauseoftheoverheatinghasbeeneliminated,theheatercanbere-startedbyswitchingoffandonagain.
• Iftheloweroruppervoltagelimitisreached,theheaterisswitchedoffafter20seconds.
• Theheaterdoesnotstartupiftheglowplugorblowermo-torisdefectiveoriftheelectricleadtothemeteringpumpisinterrupted.
• Ifthecombinedsensor(flamesensor/overheatingsensor)isdefectortheelectricleadinterrupted,theheaterstartsupandisthenswitchedoffagainduringthestartphase.
• Thespeedofthefanmotorismonitoredcontinuously.Ifthefanmotordoesnotstartuporifthespeeddeviatesbymorethan10%,theheaterisswitchedoffafter30sec.
•Whentheheaterisswitchedoff,theglowplugis switchedonfor40seconds(after-glowing)whilethe fanrunsontocleanoffanycombustionresidues.
Please note!
Donotrepeattheswitchingoff/onroutinemorethantwice.
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 8
8
Technichaldata3
Providednolimitvaluesaregiven,thetechnicaldatalistedissubjecttothetolerancesusuallyapplicabletoheatersof±10%fornominalvoltage,ambienttemperature20°CandreferencealtitudeEsslingen.
Caution!Safety instructions for technical data!Failuretocomplywiththetechnicaldatacanresultinmalfunc-tions.
Technichal data
Heatertype
Heater
Version
Heatingmedium
Controloftheheatflow
Heatflow(watt)
Heaterairflowratewithoutcounterpressure(kg/h) withhoodØ60mm
Fuelconsumption(l/h)
Elektr.powerconsumption(watt)
inoperation(12and24volt)
atstart(12and24volt)
Ratedvoltage
Operatingrange Lowervoltagelimit:Anundervoltageprotectioninthecontrollerswitchesofftheheaterwhenthevoltagelimitisreached.
Uppervoltagelimit: Anuppervoltageprotectioninthecontrollerswitchesofftheheaterwhenthevoltagelimitisreached.
Fuel
Tolarableambienttemperature
Heater
Dosingpump
Maximumairintaketemperature
Interferencesuppression
Weight
Ventilationmode
Airtronic
AirtronicD2/AirtronicD2Camper
D2/D2Camper
Air
Stage
Power Large Medium Small Off
2200 1800 1200 850 –
105 90 60 40 13
0.28 0.23 0.15 0.10 –
34 22 12 8 5
#100
12or24volt
approx.10.5voltresp.21voltUndervoltageprotectiontriggertime:20seconds
approx.16voltresp.32voltOvervoltageprotectiontriggertime:20seconds
DieselDINEN590(commerciallyavailable)
inoperation nooperation
–40°Cto+70°C –40°Cto+85°C
–40°Cto+50°C –40°Cto+125°C
max.+40°C
Interferencesuppressionclass5toDINEN55025
approx.2.7kg
possible
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 9
9
Technichaldata3Technichal data
Heatertype
Heater
Version
Heatingmedium
Controloftheheatflow
Heatflow(watt)
Heaterairflowratewithoutcounterpressure(kg/h) withhoodØ90mm
Fuelconsumption(l/h)
Elektr.powerconsumption(watt)
inoperation(12and24volt)
atstart(12and24volt)
Ratedvoltage
Operatingrange Lowervoltagelimit:Anundervoltageprotectioninthecontrollerswitchesofftheheaterwhenthevoltagelimitisreached.
Uppervoltagelimit: Anuppervoltageprotectioninthecontrollerswitchesofftheheaterwhenthevoltagelimitisreached.
Fuel
Tolarableambienttemperature
Heater
Dosingpump
Maximumairintaketemperature
Interferencesuppression
Weight
Ventilationmode
Airtronic M
AirtronicB4
B4
Air
Stage
Power Large Medium Small Off
3800 3200 2100 1300 –
185 160 120 85 24
0.54 0.46 0.29 0.18 –
40 29 15 9 5
#100
12volt
approx.10.5voltUndervoltageprotectiontriggertime:20seconds
16voltOvervoltageprotectiontriggertime:20seconds
PetrolDINEN228(commerciallyavailable)
inoperation nooperation
–40°Cto+50°C –40°Cto+85°C
–40°Cto+20°C –40°Cto+125°C
max.+40°C
Interferencesuppressionclass5toDINEN55025
ca.4.5kg
possible
Providednolimitvaluesaregiven,thetechnicaldatalistedissubjecttothetolerancesusuallyapplicabletoheatersof±10%fornominalvoltage,ambienttemperature20°CandreferencealtitudeEsslingen.
Caution!Safety instructions for technical data!Failuretocomplywiththetechnicaldatacanresultinmalfunc-tions.
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 10
10
Technichaldata3Technichal data
Heatertype
Heater
Version
Heatingmedium
Controloftheheatflow
Heatflow(watt) D3
D4
D4Plus
Heaterairflowratewithoutcounterpressure(kg/h) D3withhoodØ90mm
D4withhoodØ90mm
D4PluswithhoodØ75mm
Fuelconsumption(l/h) D3
D4
D4Plus
Elektr.powerconsumption(watt) D3
inoperation(12and24volt) D4
D4Plus
atstart(12and24volt)
Ratedvoltage
Operatingrange Lowervoltagelimit:Anundervoltageprotectioninthecontrollerswitchesofftheheaterwhenthevoltagelimitisreached.
Uppervoltagelimit: Anuppervoltageprotectioninthecontrollerswitchesofftheheaterwhenthevoltagelimitisreached.
Fuel
Tolarableambienttemperature
Heater
Dosingpump
Maximumairintaketemperature
Interferencesuppression
Weight
Ventilationmode
Airtronic M
AirtronicD3/AirtronicD4/AirtronicD4Plus
D3/D4/D4Plus
Air
Stage
Power Large Medium Small Off
3000 2200 1600 900 –
4000 3000 2000 900 –
4000 3000 2000 900 –
150 120 90 60 24
185 150 110 60 24
175 140 100 55 22
0.38 0.28 0.2 0.11 –
0.51 0.38 0.25 0.11 –
0.51 0.38 0.25 0.11 –
24 16 10 7 5
40 24 13 7 5
55 30 16 7 5
#100
12or24volt
approx.10.5voltresp.21voltUndervoltageprotectiontriggertime:20seconds
approx.16voltresp.32voltOvervoltageprotectiontriggertime:20seconds
DieselDINEN590(commerciallyavailable)
inoperation nooperation
–40°Cto+70°C –40°Cto+85°C
–40°Cto+50°C –40°Cto+125°C
max.+40°C
Interferencesuppressionclass5toDINEN55025
approx.4.5kg
possible
Providednolimitvaluesaregiven,thetechnicaldatalistedissubjecttothetolerancesusuallyapplicabletoheatersof±10%fornominalvoltage,ambienttemperature20°CandreferencealtitudeEsslingen.
Caution!Safety instructions for technical data!Failuretocomplywiththetechnicaldatacanresultinmalfunc-tions.
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 11
11
Technichaldata3Technichal data
Heatertype
Heater
Version
Heatingmedium
Controloftheheatflow
Heatflow(watt) D4S
D4Camper/D4CamperPlus
Heaterairflowratewithoutcounterpressure(kg/h) D4S
D4Camper/D4CamperPlus
Fuelconsumption(l/h)) D4S
D4Camper/D4CamperPlus
Elektr.powerconsumption(watt) D4S
inoperation(12and24v) D4Camper/D4CamperPlus
atstart(12and24v)
Ratedvoltage
Operatingrange Lowervoltagelimit:Anundervoltageprotectioninthecontrollerswitchesofftheheaterwhenthevoltagelimitisreached.
Uppervoltagelimit: Anuppervoltageprotectioninthecontrollerswitchesofftheheaterwhenthevoltagelimitisreached.
Fuel
Tolarableambienttemperature
Heater
Dosingpump
Maximumairintaketemperature
Interferencesuppression
Weight
Ventilationmode
Airtronic M
AirtronicD4S/Airtronic D4Camper/AirtronicD4CamperPlus
D4S/D4Camper/D4CamperPlus
Air
Stage
Power Large Medium Small Off
3500 3000 2000 1000 –
4000/3500 3000 2000 900 –
160 140 100 60 22
185/160 150/140 110/100 60/55 24/22
0.44 0.38 0.25 0.13 –
0.51/0.44 0.38 0.25 0.11 –
40 30 16 8 5
40 24/30 13/16 7/8 5
#100
12or24volt
approx.10.5voltresp.21voltUndervoltageprotectiontriggertime:20seconds
approx.16voltresp.32voltOvervoltageprotectiontriggertime:20seconds
DieselDINEN590(commerciallyavailable)
inoperation nooperation
–40°Cto+70°C –40°Cto+85°C
–40°Cto+50°C –40°Cto+125°C
max.+40°C
Interferencesuppressionclass5toDINEN55025
approx.4.5kg
possible
Providednolimitvaluesaregiven,thetechnicaldatalistedissubjecttothetolerancesusuallyapplicabletoheatersof±10%fornominalvoltage,ambienttemperature20°CandreferencealtitudeEsslingen.
Caution!Safety instructions for technical data!Failuretocomplywiththetechnicaldatacanresultinmalfunc-tions.
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 12
12
Check values
Test speed for the blower
Airtronic D2 / D2 Camper(12volt/24volt)• 12volt 5000rpm±25% atU=10,0volt• 24volt 5000rpm±25% atU=18,0volt
AirtronicB4 (12volt)AirtronicD3 / D3 Camper(12volt)AirtronicD4(12volt/24volt)AirtronicD4 Camper(12volt)• 12volt 4400rpm±25% atU=10,0volt• 24volt 4400rpm±25% atU=18,5volt
AirtronicD4S/Airtronic D4 Plus (12volt/24volt)AirtronicD4 Camper Plus (12volt)• 12volt 4400rpm±25% atU=10,5volt• 24volt 4400rpm±25% atU=19,0volt
Resistance values at 20 °C
12 volt 24 volt
Glowplug 0.42 –0.70 1.2 –2.0Dosingpump 9.5±0.50 36.0±1.8
Control unit resistance values
Switch position, left limit stop
Switch position, right limit stop
Controldevice12volt/24volt
min.1720max.1760
min.2096max.2216
Modulartimerandmini-controller12volt/24volt
min.1730max.1780
min.2120max.2240
Switching value Overheatingsensor 140°C–170°C measuredinthe“High”controlstage andatadistanceof300mmdownstream fromthehotairoutletExhaust emission specificationCO2 in exhaustincontrolstage“high” 7,5–12,5Vol.%SmokespotnumberaccordingtoBacharach <4
Temperature (°C)
Res
ista
nce
(ohm
)
2200
2000
1800
1600
1400
1200
1000±40 ±20 0 20 40±10±30 10 30
2400
50
Technicaldata3
Check “external” temperature sensor(OrderNo.:251774890300)The“external”temperaturesensortestmustbecarriedoutusingadigitalmultimeter.Iftheresistancevalueisnotthesameasthecurveinthediagramorthetableofvalues,re-placethetemperaturesensor.
Table of values – “external” temperature sensor
Temperature°C Resistance
min. max.0 1600 16605 1670 173010 1745 180015 1820 187020 1895 195025 1970 203030 2050 211035 2130 219040 2210 228045 2295 2370
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 13
13
Troubleshooting4What to check first in case of faults
• Check– Fuelinthetank?– Fuelpipesleaking?(visualcheck)– Summerdieselinthefuelpipe?– Combustionairsystemorexhaustsystemdamagedorblocked?
– Hotairsystemblocked?– Airpressuresensorinstalled?Ifyes,referto„Whattodoif…?“chapterofthe„AltitudeKit“installationinstructions.
– Newgenerationcontrolboxinstalled? Features: >Cableloomofcontrolboxwoundwithcabletie >Temperaturesensormountedonthesideofthecontrol
box(visiblewhencoverremoved)
• Electrical components– Cables,connectionsdamaged?– Contactscorroded?– Fusesdefective?– Incorrectwiring?(shortcircuits,interrupted/broken)
• Measure battery voltage– Batteryvoltage<10.5volt,theundervoltageprotectionofthe12voltheaterhastriggered.
– Batteryvoltage<21volt,theun
• Measure voltage supply (Cl 30) Disconnectthe16-pinconnectorS1/B1andmeasurethevoltageappliedatconnectorB1betweenchamber1(cable2.52rt)andchamber10(cable2.52br).
Ifitdiffersfromthebatteryvoltage,checkthefuses,thesupplycables,thenegativeconnectionandthepositivesupportpointonthebatteryforvoltagedrop(corrosion/interruption).
• Check switch-on signal Disconnectthe16-pinconnectorS1/B1andthenswitchontheheateratthecontrolunit.
CheckwhethervoltageisappliedintheconnectorB1betweenchamber4(cable0.52ge)andchamber10(cable2.52br).
Ifnovoltageismeasured,thencheckthesupplycable(ca-ble0.52ge),the5Afuse(item2.7.1inthecircuitdiagram)andthecontrolunit.
• Check control unit
Control device, mini-timer, mini-controller and modular timer
Disconnecttheconnectoratthecontrolunit;installajumperbetweenthered0.5²rtcableandtheyellow0.5²gecable.
IfavoltageismeasuredinconnectorB1betweencham-ber4(cable0.5²ge)andchamber10(cable2.5²br),thenreplacethecontrolunit.
EasyStart R+ / EasyStart R / EasyStart T Disconnecttheconnectoratthecontrolunit;installajumperbetweentheblack/white0.5²bl/wscableandthered0.5²rtcable.
IfavoltageismeasuredinconnectorB1betweenchamber8(cable0.5²bl/ws)andchamber10(cable2.5²br),thenreplacethecontrolunit.
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 14
14
Troubleshooting4Overview of the test equipment and control units suitable for diagnosis
Theelectroniccontrolboxcanstoreupto5faults,whichcanbereadoutanddisplayed.Thefollowingtestequipmentand/orcontrolunitscanbeusedtoquerythefaultmemoryinthecontrolboxandifnecessarytodeletethelockingofthecontrolbox:
Test equipment Order No.:
• Testingdevice forthecontroldevice 221509890000
• Diagnosticunit 221529890000 additionallyrequired: Adaptercable 221000318600
• EDiTHdiagnostictool – Basicadapterwithsoftware 221542890000 additionallyrequired: Airtronicextension 221537890000
– ISO-adapter 221541890000 additionallyrequired: Adaptercable 221000318600
– „Airpressuresensor“adaptercable221000333100 Onlyforheaterswithconnectedairpressuresensorfor
readingoutthe„airpressuresensor“faultmemory.
Ifadiagnosticscableisconnected,thefollowingcontrolunitscanalsobeused:
Control units Order No.:
•Moduletimer 221000303400
• TP5radioremotecontrol 221000320100
• EasyStartT 221000328800
• EasyStartR+ 221000328000
Please note!
Ifthefaultmemorycannotbereadout,checkthediagnosticscableforcorrectlayingandpossibledamage.
Important notes on diagnosis of heaters with mini-controller control unit
Caution!WhencheckingtheheaterwiththediagnosticsunitortheEDiTHdiagnosticstooltheordergiveninthefollowingnotesmustalwaysbefollowedasotherwisetheheaterdetectsError62(controlunit–interruption)andswitchestoemergencyoperation.
Mini-controller in stand-alone operation
• Connectadaptercable221000318600asdescribedintheoperatinginstruction.
• Selectoperatingmode(Heat/Ventilate)atthemini-control-ler
• PerformdiagnosisusingthediagnosticsunitortheEDiTHdiagnosticstool.
• Switchoffthemini-controllerafterfinishingthediagnosis• Removetheadaptercable
Mini-controller in combination with mini-timer
• Connectadaptercable221000318600asdescribedintheoperatinginstruction.
• Pressthembuttonofthemini-timer• Selectoperatingmode(seemini-timeroperatinginstruc-tions)
• PerformdiagnosisusingthediagnosticsunitortheEDiTHdiagnosticstool.
• Switchoffthemini-timerafterfinishingthediagnosis• Removetheadaptercable
Mini-controller in combination with TP5
• Connectadaptercable221000318600asdescribedintheoperatinginstruction.
• Pressthe buttonoftheTP5radioremotecontrol• Selectoperatingmode(seeTP5radioremotecontroloper-atinginstruction)
• Performdiagnosis.• SwitchoffTP5radioremotecontrolafterfinishingthediag-nosis
• Removetheadaptercable
Please note!
IftheoperatingmodeistobechangedduringthetesttheheatermustbeswitchedofffirstusingthediagnosticsunitortheEDiTHdiagnosticstool,otherwisetheheaterdetectsError62(controlunit–interruption)andswitchestoemergencyoperation.
Test mini controller
Themini-controllermustbeconnectedtotheheaterfortest-ing.ThesetpointvaluecanbedisplayedusingtheEDiTHdiagnosticstool.Iftherotaryknobisattheleftlimitstopthesetpointvalueis8°C,attherightlimitstopitis34°C.
Please note!
Theresistanceofthesetpointvaluepotentiometercannotbemeasureddirectly.Themeasuredvaluesarenotmeaningful.
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 15
15
Troubleshooting4Testing device for the control device(OrderNo.:221509890000)
Prepare for testConnectthecorrectoperatingvoltage(12or24volt)tothete-stingdevice,withplusattheredconnectorsocketandminusattheblueconnectorsocket.
• Disconnectsocketfromthecontrolunit.• Connectcableloomfromtestingdevicewiththecontrolunit.
• Settherotaryknobofthecontrolunitto“Heat”,thecorre-spondingredLEDinthetestingdevicemustlightup.
• Setcontrolunitto“0”,thenpressthe“LED–red”button,theredcontrollampinthecontrolunitmustlightup.
• Setcontrolunitto“Heat”,thenpressthe“LED–green”button,correspondingredcontrollampinthetestingdeviceandthegreencontrollampinthecontrolunitmustlightup.
Caution!Safety instructions for checking the control unit!Ensureyouusethecorrectoperatingvoltage,otherwisetheconnectedcomponentscanbeseverelydamaged.
Check the setpoint potentiometer of the control unitSetthe“Temperaturesensor/Potentiometer”switchinthetestingdevicetothe“Potentiometer”settingandslowlyturntherotaryknobofthecontrolunit.ThegreenLED–temperaturesensor/potentiometermustlightupcontinuously.Incaseofafault,replacethecontrolunit.
1 Testingdevice2 Controldevice
Diagnostic unit(OrderNo.:221529890000)
Anadditionaladaptercableisrequiredtoconnectthediag-nosticunit(OrderNo.:221000318600).
Thecurrentfaultisdisplayedas“AF”anda2-digitnumberandisalwayswritteninthememorypositionF1.PrecedingfaultsaremovedtothememorylocationsF2–F5,ifnecessarythecontentsofmemorypositionF5isoverwrit-ten.
• Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.
• Inheaterswithconnectedairpressuresensorthediagnos-ticsunitcanbeusedtoreadoutthefaultmemoryoftheheateronly.
Thefaultmemoryofthe„airpressuresensor“canbereadoutusingtheEDiTHdiagnosticstoolonly.
• Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.
l–Deletefaultmemoryl–Deletefaultmemoryd–Switchheateron/off,requestdiagnosise–Reverse,F5–F1f–Forward,F1–F5,currentfault(AF)
Connectdiagnosticsunit,seepage16.
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 16
16
Connect diagnostic unit• Disconnectthe8-pinconnectoroftheheater’scablehar-nessandconnecttheadaptercable.
• Connectthediagnosticunittotheadaptercable. Displayisasfollows:
Query fault memory• UsetheDkeytoswitchontheheater. Displayisasfollows:
• After8secthefollowingisdisplayed: Displayisasfollows:
Heaterhasnomalfunction or
e.g.currenterror/faultcode64
or
Faultdiagnosisnotpossible
Possiblecauses: – Adaptercableisnotproperlyconnected. – Controlboxisdefectiveorisnotcapableofdiagnosing
(notauniversalcontrolbox).
Display of the fault memory F1 – F5 or F5 – F1• Presstheeorfbutton,orpressseveraltimes,todisplaythefaultmemory.
Displayisasfollows:
e.g.faultmemory2/faultcode10
Onlythefaultmemorypositionswithanerrorassignedtothemaredisplayed.
Delete fault memory• PressbothLbuttonssimultaneouslyuntilthefollowingap-pearsinthedisplay:
Displayisasfollows:
• Ifthefaultmemoryhasbeendeletedthemostrecentcur-rentfaultisdisplayed.Thecurrentfaultisnotresetto00untiltheheaterisrestarted–providedthereisnonew,morerecentfault.
Displayisasfollows:
Heaterhasnomalfunction
Cancel the control box lock• Deletethefaultmemoryasdescribedandswitchofftheheaterusingthedkey.
• Thecontrolboxlockiscancelledandthediagnosisclosed. Displayisasfollows:
Troubleshooting4
1 Heater2 Adaptercable3 Diagnosticunit
1
2
3
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 17
17
Troubleshooting4EDiTH diagnostic tool with ISO adapter(OrderNo.:221541890000)
AnadditionaladaptercableisrequiredtoconnecttheISOadapter(OrderNo.:221000318600).
• Itisveryimportanttoalwaysinstallinthegivenorder.• Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.
• Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.
• TheEDiTHdiagnosticstoolscopeofsupplydoesnotincludethesoftware;thismustbedownloadedfromtheServicePortal.
Connect ISO adapter
• Disconnecttheheater’scableharness.• Connecttheadaptercabletothecableharness–asshowninthesketch.
• ConnecttheadaptercabletotheISOadapter.• ConnecttheSUB-DconnectioncablewiththePCandthe ISOadapter.
Installing the software on your PC• Doubleclickthe“setup.exe”filetostarttheinstallationandfollowingtheSETUPprograminstructions.
Query / delete fault memory F1 – F5 or cancel the control box lock• StartthesoftwareonyourPC: – onthedesktop—>doubleclickthe“EDiTH”icon – Selectheatertype – Pressthe“GO”button.
• Deletefaultmemoryorcancelthecontrolboxlock: – pressthe“Deletefaultmemory”button —>thestoredfaultsF1–F5aredeletedandthecontrol
boxisunlocked.
Quit diagnosis• Pressthe“STOP”button—>faultmemoryqueryisended.
1 Heater2 Adaptercable3 ISOadapter
4 SUB-Dconnectioncable5 USBtoSerialRS-232adapter
e
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 18
18
Troubleshooting4Air pressure sensor diagnosis using EDiTH diagnostics tool and ISO adapter(OrderNo.221524890000)
AnadditionaladaptercableisrequiredtoconnecttheISOadapter(OrderNo.:221000333100).
Theairpressuresensorconnectedtotheheatercanbediag-nosed.Iffaultsoccurduringthealtitudeadjustmenttheyarestoredintheairpressuresensor.Ifnecessary,faultscanbereadoutusingtheISOadapterinconjunctionwiththeEDiTHdiagnosticstool–fromVersionS3V7-F–andtheadditionallynecessaryadaptercable.
Please note!
• Itisveryimportanttoalwaysinstallinthegivenorder.• Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.
• Faultcode,faultdescription,cause/remedialactionaredescribedonpages27.
• TheEDiTHdiagnosticstoolscopeofsupplydoesnotincludethesoftware;thismustbedownloadedfromtheServicePortal.
Perform diagnosis of the air pressure sensor
Disconnecttheconnectorbetweentheairpressuresensor/heater,controlunit,connecttheISOadapterwiththeadaptercable(seesketch).Startthediagnosisoftheairpressuresensor.
• Double-clickthe>>EDiTH<<icononthedesktop.• Selecttheairpressuresensorinthe»HeaterandTestSe-lection«.
Thefollowingactionsarepossible:– Readoutthecurrentfaultandthefaultmemory.– Deletethefaultmemory.– Querythecurrentmeasuredairpressure.– Querytheoperatingstate.– Querythegeneraldata.– Printoutthefaultmemoryand/orthegeneraldata
• Exitthediagnosiswiththe»Stop«buttonorbyclosingallwindows.– Selection:Saveanalysis/Donotsaveanalysis
• RemoveISOadapterandadaptercablefromtheleadhar-nessandreconnecttheairpressuresensor/heater,controlunitconnector.
1 Airpressuresensor2 Adaptercable3 Cableloomfromheater4 Cableloomtocontrolunit
5 ISOadapter6 SUB-Dconnectioncable7 USBtoSerialRS-232adapter
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 19
19
Caution! Magnetic field!Duringthetestoperationamagneticfielddevelopsattheadapter.Therefore,donotplaceanyobjectssuchasdatamedia,creditcards,etc.ontheadapterorinitsimmediatevicinity.
Troubleshooting4
(A) Basicadapter(B) SUB-Dconnectioncable(C) Mainsconnection(D) Mainsswitch(E) USBtoSerialRS-232adapter(F) Adapter(G) Controlbox
Cable colourssw = blackgn = greenbl = blue
EDiTH diagnostic tool with basic adapterEDiTHbasicadapter(OrderNo.:221542890000)
Anadditionalextensionisrequiredtocheckthecontrolbox(OrderNo.:221537890000).
• Itisimportanttoalwaysfollowthepreciseconnectionorderasgivenbelow!
• TheHallsensorintegratedinthecontrolboxcanonlybeproperlytestedinthecontrolboxiscorrectlyplacedontheextension.
• Onlypushorpullontheconnectors,notonthecables!• OnlyusethenetworkcableandRS232cablewithsnapferritesincludedinthescopeofsupply.Useoriginalacces-sorieswithsnapferritesonlytoconnectthetestequipment.
• Notonlythedefectivecomponent,butalsoadefectivecurrentcircuitresultsinafaultbeingdisplayed.
• Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.
Connect basic adapter• Startcomputerandwaituntilthesystemhassuccessfullybooted.
• StartPCsoftware.• Inserttheunitconnectorofthemainscableinthebasicadapter(A)andconnectthemainsconnection(C)tothemains.
• ConnecttheSUB-Dconnectioncable(B)withthePCandbasicadapter(A).
Connect extension and test control box• Connecttheextensiontothebasicadapter(A).• Connectthecontrolbox(E)totheextensionandtheadap-ter(F).
• Switchonthebasicadapter(A)atthemainsswitch(D).• Selectthecontrolboxversionandoperatingvoltage(12V/24V)inthePCsoftware.
• StartthecontrolboxtestwiththePCsoftware.Amorede-taileddescriptionofhowtooperatethebasicadapters(A)isgivenintheEDiTHonlinehelp.
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 20
20
Troubleshooting4Module timer(OrderNo.:221000303400)
Thecurrentfaultisdisplayedas“AF”andisalwayswritteninmemorypositionF1.PrecedingfaultsaremovedtothememorylocationsF2–F5,ifnecessarythecontentsofmemorypositionF5isoverwrit-ten.
• Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.
• Inheaterswithconnectedairpressuresensorthemodulartimercannotbeusedtoperformdiagnoses.Thediagnos-ticsunitortheEDiTHdiagnosticstoolmustbeusedtoperformthediagnosis.
Thefaultmemoryofthe„airpressuresensor“canbereadoutusingtheEDiTHdiagnosticstoolonly.
• Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.
Query fault memory F1 – F5 Condition:Theheaterisswitchedoff.
• Pressckey–>theheaterisswitchedon.
• Pressakeyandkeeppressed, thenpresspkeywithin2seconds. Displayisasfollows: AF=currentfault 3digitnumber=faultcode cflashes.
• Pressfkeyonceorseveraltimes,faultmemorypositionsF1–F5aredisplayed.
Cancel the control box lock and simultaneously delete the fault memoryCondition:Anelectricalconnectionexistsfromterminal15(ignition)tothemoduletimer,12-pinconnector,chamber10.
• Pressckey Displayisasfollows: thecurrentfaultF15orF50.
• Pressbuttona,keepitdepressedandthenpressbuttonpwithin2seconds.
Themoduletimerisnowinthe“Queryfaultmemory”pro-gram.
• Switchoffignition(terminal15).
• Simultaneouslypressbuttonaandbuttonp,inaddition,switchontheignition(terminal15)andwaituntilthefollow-ingappearsinthedisplay.
Afterignition“ON”thefollowingappearsinthedisplay:
Displayflashes, Heatersymboldoesnotflash
• Switchtheheateroffandon–>thecontrolboxisunlocked,theheaterrestarts.
Afterswitchingtheheateroffandonandrenewedqueryofthefaultmemory,thefollowingappearsinthedisplay:
Displayflashes, Heatersymboldoesnotflash
a–Timep–Presetc–Heate–Reversef–Forward
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 21
21
Troubleshooting4TP5 radio remote control(OrderNo:221000320100)
Iffaultsoccurwhiletheheaterisrunning,theyaredisplayedwith“Err”afterthemobileunitisactivated.
Afterthediagnosticscable(bl/ws)hasbeenconnectedandthefirstlogshavearrivedatthestationaryunit,thediagnosecanbecarriedoutusingthemobileunitoftheTP5radioremotecontrol.Thecurrentfault“F0”isdisplayed.Thestoredfaults“F1”to“F5”canbequeried.
• Inordertocarryoutthediagnosis,thediagnosticscable(bl/ws)mustbeconnectedtothestationaryunitandtheheatercableharness.Tothisend,pleaserefertoandfollowthecircuitdiagramfortheTP5radioremotecontrolandtheheater.
• Ifthediagnosticscable(bl/ws)isnotconnected,the“Diag-nosis”menuisblocked.
• Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.
• InheaterswithconnectedairpressuresensortheTP5radioremotecontrolcannotbeusedtoperformdiagnoses.ThediagnosticsunitortheEDiTHdiagnosticstoolmustbeusedtoperformthediagnosis.
Thefaultmemoryofthe„airpressuresensor“canbereadoutusingtheEDiTHdiagnosticstoolonly.
• Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.
Buttontoactivate/deactivatethemobileunit
Buttonforforwardtimesetting
Buttonforbackwardtimesetting
Buttonforactivatingthepossiblesettings
Buttonforswitchingheat/ventilateON/OFF; Activate/deactivatepreselectedtime
Enquire / delete fault memoryUsethe keytoactivatethemobileunit.Switchontheheaterwiththe key.Pressthe keytwicetoopentheTimesettingmenu–thetimeflashesinthedisplay.
Pressthe keyforapprox2sec–untilthefollowingap-pearsinthedisplay:
Press key.Press key.Press keytwice.Press key.
Malfunctioninheater: Heaterhasnomalfunction:
Usethe and buttonstocallupthefaultmemoryposi-tions1to5.
Delete fault memory / Cancel the control box lockUsethe keytodeletethefaultmemory.
Toconfirm,pressthe keyforapprox2secuntil lightsupinthedisplay–faultmemoryisdeleted.
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 22
22
The following actions are possible• Callupfaultmemory. CallupthefaultmemorypositionsF1–F5with or .
• Callupfaultmemoryagain. Brieflypress and simultaneously.
• Deletefaultmemory (displaydEL) Press .
Press again.
The diagnosis is completed.
Switch off heater.
Enquire / delete fault memoryActivatemobilepart/timer(seeEasyStartR+/EasyStartToperatinginstructions)
Confirmsymbol with .
Heater is switched on.
Confirmoperatingtimewith .
Brieflypress and simultaneously.
Troubleshooting4EasyStart R+ radio remote control(Order-No.:221000328000)
EasyStart T timer(Order-No.:221000328800)
Iffaultsoccurwhiletheheaterisrunning,theyaredisplayedwith“Err”afterthemobileunitortimerisactivated.
Thecurrentfaultisdisplayed.Thestoredfaults“F1”to“F5”canbequeried.
• Inordertocarryoutthediagnosis,thediagnosticscable(bl/geatheaterconnector,bl/wsatcableharnessconnector)mustbeconnectedtothestationaryunitandtheheatercableharness.Tothisend,pleaserefertoandfollowthecircuitdiagramfortheradioremotecontrolandtheheater.
• Ifthediagnosticscableisnotconnected,the“Diagnosis”menuisblocked.
• Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.
• Theheaterdiagnosiscanalsobeperformediftheairpres-suresensorisconnected.
Thefaultmemoryofthe„airpressuresensor“canbereadoutusingtheEDiTHdiagnosticstoolonly.
• Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.
Backcontrolkey
Nextcontrolkey
ON/OFFactivationkeymobileunit/timer
OKkey(symbolselection/confirminput)
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 23
23
Troubleshooting4Fault codeDisplay
Fault description Comments• Remedial action
000 Nofaults ——
004 Warning:Shortcircuitincontrolbox,freshairoutput
• DisconnectconnectorS1/B1attheheaterandattheconnectorB1,PIN16checkthecableuptothefreshairfanrelayforshortcircuittonegative,ifok—>replacecontrolbox.
005 Warning:Shortcircuitincontrolbox,caralarmoutput
• DisconnectconnectorS1/B1attheheaterandattheconnectorB1,PIN15checkthecableuptotherelayisolatingswitchorburglaralarmsysteminputforshortcircuittonegative,ifok—>replacecontrolbox.
006 Warning:Inexplicableatmosphericaltitudeinformation(Displayonlyifheaterslabelled“H-Kit”onthenameplate.)
Controlboxhasnotreceivedanyexplicablealtitudeinformation.• ReadoutfaultmemoryintheairpressuresensorusingtheEDiTHdiagnos-ticstoolandcorrectfault.
009 Cut-offADR ADRshutdownduetosignalchangefrom(+)to(–)atconnectorS1,PIN13(D+)orplussignalatconnectorS1,PIN14(HA+).
010 Overvoltage–cut-off Overvoltageappliedtocontrolboxforatleast20secondswithoutinterruption–heaternotworking.• DisconnectconnectorS1/B1attheheater,startthevehicle’sengine,measurethevoltageatconnectorB1betweenPIN1(cable2.52rt)andPIN10(cable2.52br).
Airtronic12volt–voltage>16volt—>checkgeneratorregulator Airtronic24volt–voltage>32volt—>checkgeneratorregulator
011 Undervoltage–cut-off Undervoltageappliedtocontrolboxforatleast20secondswithoutinterrup-tion–heaternotworking.• DisconnectconnectorS1/B1attheheater,thevehicle’sengineisswitchedoff,measurethevoltageatconnectorB1betweenPIN1(cable2.52rt)andPIN10(cable2.52br).
Themeasuredvalueandthevoltageatthebatteryshouldbethesame. Incaseofavoltagedrop,checkthefuses,thesupplycables,thenegativeconnectionsandthepositivesupportpointonthebatteryforcorrosionandcorrectcontact.
012 Overheatingattheoverheatingsensor Temperatureoftheoverheatingsensortoohigh.• Checkhotairpipesforblockage—>removeblockage.• Sumofthecomponentratingsofair-conductingpartsistoolarge—>Checkairsystem,ifnecessaryre-lay–forcomponentratings,pleaserefertoadditionalpartscatalogue.
• Checkoverheatingsensor,fordiagramandtableofvaluespleaserefertoPage32,ifok—>measurefuelquantity,seePage36.
013 Overheatingattheflamesensor Flamesensorsignalstemperatureatheatexchangeristoohigh.• Checkhotairpipesforblockage—>removeblockage.• Sumofthecomponentratingsofair-conductingpartsistoolarge—>Checkairsystem,ifnecessaryre-lay–forcomponentratings,pleaserefertoadditionalpartscatalogue.
• Checkflamesensor,ifok—>checkoverheatingsensor,ifoverheatingsensordefective—>replacecombinationsensor,ifoverheatingsensorok—>measurefuelquantity,seePage36,fordiagramandtableofvaluesforflamesensorandoverheatingsensorpleaserefertoPage32.
014 Temperaturedifferencebetweenflamesensorandoverheatingsensortoolarge
Temperaturedifferencebetweenflamesensorandoverheatingsensortoolarge• Checkhotairpipesforblockage—>removeblockage.• Sumofthecomponentratingsofair-conductingpartsistoolarge—>Checkairsystem,ifnecessaryre-lay–forcomponentratings,pleaserefertoadditionalpartscatalogue.
• Checkflamesensor,ifok—>checkoverheatingsensor,ifoverheatingsen-sordefective—>replacecombinationsensor,ifoverheatingsensorok—>measurefuelquantity,seePage36,iffuelquantityok—>replacecontrolbox.Fordiagramandtableofvaluesforflamesensorandoverheatingsen-sor,seePage32.
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 24
24
Troubleshooting4Fault codeDisplay
Fault description Comments• Remedial action
015 Operatinglock-out Thefaultcode015isdisplayed,iftheheaterwasswitchedbackonafterthefaultcodedisplay017.
Thehardwarethresholdvaluefortheoverheatingsensorhasbeenexceeded—>thecontrolboxislocked.
• Replacecontrolbox.
017 Overheating Thehardwarethresholdvaluefortheoverheatingsensorhasbeenexceeded,becausethecontrolboxfailedtorecognisethefaultcode012or013–>thecontrolboxislocked.Iftheheaterisswitchedonagain,thefaultcode015isdisplayed.• Replacecontrolbox.
018 Startingenergyoftheglowplugistoolow(Displayonlyifheaterslabelled“H-Kit”onthenameplate.)
• Checkglowplug(seefaultcode020and021),ifok• Checkglowplugcableharnessforcorrectlayinganddamage,ifok—>checkcableharnessforcontinuity,ifok—>replacecontrolbox.
019 Ignitionenergytoolow •Checkglowplug(seefaultcode020and021),ifok• Checkglowplugcableharnessforcorrectlayinganddamage,ifok—>checkcableharnessforcontinuity,ifok—>replacecontrolbox.
020
021
Glowplug–interruption
Glowplug–shortcircuit,overloadorshortcircuitafternegative
• Checkglowplugforfunctionandcontinuityatambienttemperature20°C. 12voltheater–0.42upto±0.7 24voltheater–1.2upto±2.0
• Ifthevaluesareok—>checkglowplugleadharnessfordamageandcon-tinuity,ifok—>replacecontrolbox.
022 * Glowplug,output(+)–shortcircuitafterUB(batteryvoltage)
• Checkglowplugleadharnessforcorrectlayinganddamage,ifok—>checkleadharnessforcontinuity,ifok—>replacecontrolbox.
025 * Diagnosticscablebl/ws–shortcircuit–afterUB(batteryvoltage)
Faultcodedisplayisnotpossible.Thisfaultcodecannotbereadoutfromthefaultmemoryuntilthefaulthasbeencorrected.• Checkdiagnosticscableforcorrectlayingandpossibledamage.
031 Blower–interruption • Checkthattheleadharnessoftheblowermotorhasbeencorrectlylaidandcheckfordamage,ifok—>removeleadharnessatcontrolboxandcheckforcontinuity,ifok—>replacecontrolbox.
032 Blowermotor–shortcircuitafternegative
Please note!
Ensurecompliancewiththetestvolt-age(seepage12).Thecomponentisdestroyedifthevoltagevalueisexceeded.Ensure the power pack has ad-equate short-circuit resistance – min 20 A.
• Carryoutfunctionaltestontheblowermotor,todothisremovethecon-nectorfromthecontrolbox.Applyatestvoltage(seepage12)totheblow-ermotorandmeasurethecurrentintensityafter40sec.
Currentintensity<6.5A–blowermotorok–>replacecontrolbox. Currentintensity>6.5A—>replaceblower.• Checkwiringforshortcircuit.
033 Blowermotorwon’trotateorshortcircuitafternegative
Please note!
Ensurecompliancewiththetestvolt-age(seepage12).Thecomponentisdestroyedifthevoltagevalueisexceeded.Ensure the power pack has ad-equate short-circuit resistance – min 20 A.
Speeddeviation>10%fromsetpointvalueforlongerthan30seconds.Useanon-contactr.p.m.countertomeasurethespeedofthecombustionairfan(seepage12fortestspeedandtestvoltage).
• Speedtoolow: Blowerblocks–checkblowerforfreerunning,ifnecessaryremoveforeignbody,ifok—>checkblower(seefaultcode032).
• Speedtoohigh: –Magnetmissingfromblowerimpeller—>replaceblower. – Speedsensorincontrolboxisdefective—>replacecontrolbox.• Checkwiringforshortcircuit.
* Thisfaultcodeorohmicvalueisvalidforanewgenerationcontrolboxonly.Thisdiffersfromthecontrolboxtodatebyitscableloomwrappedincabletapeandbyatemperaturesensormountedontheside,whichbecomesvisiblewhenthecoverisremoved.
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 25
25
Troubleshooting4Fault codeDisplay
Fault description Comments• Remedial action
034 * Blowermotor,outlet(+)shortcircuitafterUB(batteryvoltage)
• Checkthattheleadharnessoftheblowermotorhasbeencorrectlylaidandcheckfordamage,ifok—>removeleadharnessatcontrolboxandcheckforcontinuity,ifok—>replacecontrolbox.
047 Meteringpump–shortcircuitoroverload
• Removeconnectorfromthemeteringpump,ifthefaultcode048(inter-ruption)isdisplayedthemeteringpumpisdefective—>replacemeteringpump.
• Ifthefaultcode047continuestobedisplayed,disconnectconnectorS1/B1attheheater,andattheconnectorB1,PIN5checkthecable12gn/rtuptothemeteringpumpforshortcircuittonegative(PIN10),ifok–>replacecontrolbox.
048 Meteringpump–interruption • Disconnectconnectorfrommeteringpumpandmeasuretheresistancevalueofthemeteringpump(seePage12forvalues),ifresistancevalueok,re-connectthecableloomtothemeteringpump.
• DisconnectconnectorS1/B1attheheaterandmeasuretheresistancevalue(seePage12)betweenPIN5andPIN10,ifok—>replacecontrolbox.
049 * Meteringpumpoutlet(+)Shortcircuit–afterUB(batteryvoltage)
• Checkthattheleadharnessofthemeteringpumphasbeencorrectlylaidandcheckfordamage,ifok—>removeleadharnessandcheckforconti-nuity,ifok—>replacecontrolbox.
050 Toomanyfailedstartattempts(opera-tinglock-out)
Thecontrolboxlocksaftertoomanyfailedstartattempts(max.255startat-tempts).• Unlockthecontrolboxbydeletingthefaultmemorywiththetimer,thediagnosticunit,EDiTHdiagnostictool,theTP5radioremotecontrol/EasyStartR+andtheEasyStartTtimer.
051 Flamedetectedwhenswitchingon If,afterbeingswitchedon,theresistancevalueoftheflamesensoris1274(>70°C)theheater’sfanrunsforapprox15mintocooldown,iftheresist-ancedoesnotfallbelowtheaforementionedvaluewithin15mintheheaterisswitchedoff.
• Checkflamesensor,seePage32fordiagramandtableofvalues,ifok—>replacecontrolbox.
052 Safetytimeexceeded Noflamedetectedwithinthestartphase.• Checkexhaustandcombustionairsystem.• Checkfuelsupply/measurefuelquantity,seePage36.• Checksparkplug(seefaultcode020and021)• Checkflamesensor,diagramandtableofvalues,seePage32,ifok—>replacecontrolbox.
053
054
055
056
Flamecutoutinthe
“POWER”controlstage
“HIGH”controlstage
“MEDIUM”controlstage
“LOW”controlstage
Theheaterhasignited(flamedetected)andsignalsflamecutoutduringapowerstage.
• Checkexhaustandcombustionairsystem.• Checkfuelsupply/measurefuelquantity,seePage36.• Checkflamesensor,diagramandtableofvalues,seePage32,ifok—>replacecontrolbox.
057 Flamecutoutfromstartphase(Displayonlyifheaterslabelled“H-Kit”onthenameplate.)
Aflamecutoutwasdetectedduringthestartphase..• Checkexhaustandcombustionairsystem.• Checkfuelsupply/measurefuelquantity,seePage36.• Checkglowplug(seefaultcode020and021).• Checkflamesensor,diagramandvaluestable,seepage32,ifok—>replacecontrolbox.
060 Externaltemperaturesensor–interruption
• DisconnecttheconnectorS4/B4oftheexternaltemperaturesensorandmeasuretheresistancevalueatconnectorB2,fordiagramandtableofva-luesseePage12,iftemperaturesensorok,reassembleconnectorS4/B4.
• DisconnectconnectorS1/B1attheheaterandmeasuretheresistancevalueinconnectorhousingB1betweenPIN6andPIN12.Ifinterruptedtheohmicvalueis>7175/3k*.Ifresistancevalueok—>replacecontrolbox.
* Thisfaultcodeorohmicvalueisvalidforanewgenerationcontrolboxonly.Thisdiffersfromthecontrolboxtodatebyitscableloomwrappedincabletapeandbyatemperaturesensormountedontheside,whichbecomesvisiblewhenthecoverisremoved.
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 26
26
Troubleshooting4Fault codeDisplay
Fault description Comments• Remedial action
061 Externaltemperaturesensor–shortcircuit
• DisconnectconnectorS4/B4oftheexternaltemperaturesensor,iffaultcode060isdisplayed—>checkexternaltemperaturesensor,diagramandtableofvalues,seePage32.Iftemperaturesensorok—>checkconnec-tioncables0.5grand0.5br/wsforshortcircuit,ifok,reassemblethecon-nectorS2/B2.
• DisconnectconnectorS1/B1attheheaterandmeasuretheresistancevalueinconnectorhousingB1betweenPIN6andPIN12.Incaseofshortcircuittheohmicvalueis<486/<800*.
Iferror061continuestobedisplayed—>replacecontrolbox.
062 Controlunit–interruption
Please note!
Refertonotesondiagnosiswithmini-controlleronpage14.
Heaterrunsin„High“controlstageonly• Removeconnectoratthecontrolunitandmeasuretheresistancevalueofthesetpointpotentiometer,forconnectorpinsseePage42onwards.Iftheresistancevalueisok,reconnectconnectoratthecontrolunit.
• DisconnectconnectorS1/B1attheheater,measuretheresistancevaluebetweenPIN6andPIN7inconnectorhousingB1,ifresistancevalueok—>replacecontrolbox.Resistancevalueincaseofinterruption>7175 />3k *.Normalvalues:seepage12.
063 Controlunit–shortcircuit
Faultrecognitiononlyworksinhea-tingmode.If,ontheotherhand,theshortcircuithasalreadyoccurredandthentheheaterisswitchedon,„Venti-lation“isactive(notafaultcode).
• Ifthe“Ventilate”switchisinstalled,disconnectitandcheckitworks.Ifnotok—>replaceswitch.
• Disconnectconnectoratcontrolunit,iferrorcode062isdisplayed,replacethecontrolunit.Ifcontrolunitok,checkconnectioncables0.5gr/rtand0.5br/wsforshortcircuit,ifok—>reconnectconnectoratcontrolunit.
• DisconnectconnectorS1/B1attheheater,iftheerror063continuestobedisplayed—>replacecontrolbox.Resistancevalueincaseofshort-circuit<486 / <800 *.Normalvalues:seepage12.
064 Flamesensor–interruption • Dismantlecontrolboxanddisconnectgreenconnectorfromcontrolbox.Checkflamesensor,diagramandtableofvalues,seePage32,ifflamesen-sorok—>replacecontrolbox.Resistancevalueincaseofinterruption>7175 />3k *.
065 Flamesensor–shortcircuit Dismantlecontrolbox,removegreenconnectorfromcontrolbox,iferror064isdisplayed—>replacecombinationsensor.
Iferror065continuestobedisplayed—>replacecontrolbox. Resistancevalueincaseofshortcircuit<486 /<500*,seealsodia-gramonPage32.
071 Overheatingsensor–interruption • Dismantlecontrolbox,disconnectblueandgreenconnectorsfromcontrolbox.MeasureresistancevalueatblueconnectorPIN1(cable0.52bl)andatgreenconnectorPIN2(cable0.52br/ws),ifok,—>replacecontrolbox.
Resistancevalueincaseofinterruption>223k />1600k *,seealsodiagramonPage32.
072 Overheatingsensor–shortcircuit • Dismantlecontrolbox,removeblueconnectorfromcontrolbox,iferror071isdisplayed—>replacecombinationsensor.
Iferror072continuestobedisplayed—>replacecontrolbox. Resistancevalueincaseofshortcircuit<183 /<95*,seealsodia-gramonPage32.
074 * Controlboxdefective •Overheatingthresholdvalueisnotdetectedbycontrolbox—>replacecon-trolbox.
090 Controlboxdefective(internalfault) • Replacecontrolbox.
091 Externalinterferencevoltage • Controlboxfaultduetointerferencevoltagesfromthevehicle’selectricalsystem.Possiblecauses:
Poorbattery,charger—>removeinterferencevoltage.
092 Controlboxisdefective(ROMerror) • Replacecontrolbox.
093 * Controlboxdefective • Replacecontrolbox.
* Thisfaultcodeorohmicvalueisvalidforanewgenerationcontrolboxonly.Thisdiffersfromthecontrolboxtodatebyitscableloomwrappedincabletapeandbyatemperaturesensormountedontheside,whichbecomesvisiblewhenthecoverisremoved.
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 27
27
Troubleshooting4Fault codeDisplay
Fault description Comments• Remedial action
094 Controlboxdefective(EEPROM-Fehler)
• Replacecontrolbox.
095 * Controlboxdefective • Replacecontrolbox.
096 Internaltemperaturesensordefective • Replacecontrolboxoruseanexternalroomtemperaturesensor..
097 Controlboxdefective • SReplacecontrolbox.
098 * Controlboxdefective • Replacecontrolbox.
099 * Toomanyresetsinsequence
Transistorerrorincontrolbox
• Voltageshort-term<5–6volt(for12volt)or<7–8volt(for24volt). Incaseofavoltagedrop,checkthefuses,thesupplycables,thenegativeconnectionsandthepositivesupportpointonthebatteryforcorrosionandcorrectcontact.
Testcontrolboxwithtestingdevice,ifok—>checkleadharnessoftheex-ternalcomponentshasbeencorrectlylaidandcheckfordamage,ifok—>checkleadharnessforcontinuity,ifok—>replacecontrolbox.
Air pressure sensor fault code displayFault code display
Fault description Comments• Remedial action
0 Nofaults —
11 Communicationloss Interruptionofthediagnosticscablebetweenthecontrolbox(heater)andtheairpressuresensor• Checkwiringandplug-inconnections
12 Noaltitudeadjustment Controlbox(heater)doesnotsupportaltitudeoperationwiththeairpressuresensor• Useacontrolbox(heater)whichsupportsaltitudeadjustment
13 Airpressuresensorfault Theairpressuresensorisdefective• Replacetheairpressuresensor
* Thisfaultcodeorohmicvalueisvalidforanewgenerationcontrolboxonly.Thisdiffersfromthecontrolboxtodatebyitscableloomwrappedincabletapeandbyatemperaturesensormountedontheside,whichbecomesvisiblewhenthecoverisremoved.
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 28
28
Repair instructions
Thepermittedrepairworktotheheaterisdescribedinthe“RepairInstructions”chapter.Ifextensiverepairsarenecessary,itmakessensetodismantletheheater.
Theheaterisassembledinthereverseorder,ifapplicablenotadditionalinstructions.
Aftercompletingalltheworkontheheater,youmustcarryoutafunctionalcheck(seePage4).
Always observe the following safety instructions before working on the heater:
Danger!Risk of injury, burns and poisoning!• Alwaysswitchofftheheaterbeforehandandleaveittocool.• Disconnectthebattery.• Theheatermustnotbeoperatedinclosedroomssuchasgaragesorworkshops.
Exception: Exhaustsuctionavailabledirectlyattheentrytotheexhaustpipe.
Caution!• Thesealsofdismantledcomponentsmustberenewed.• Duringrepairwork,checkallcomponentsfordamageandifnecessaryreplace.
• Checkconnectorcontacts,plug-inconnectionsandcablesforcorrosionanddamageandifnecessaryrepair.
• OnlyeveruseEberspächersparepartsifreplacementsarenecessary.
• Operationortheafterrunningoftheheatermayonlybestoppedinanemergency(see“EMERGENCYOFF”Page8)byinterruptingthebatterycurrent(riskofheateroverheat-ing).
Repairinstructions5Special tool
AMP release tool
TheAMPreleasetoolisusedtoreleaseplug-incontactsinaconnectorhousing.
ThisreleasetoolcanbeordereddirectlyfromAMP.
• ForMicroTimer: AMPOrderNo.0-0539960-1
• ForJunior-Power-Timer: AMP-Bestell-Nr.1-1579007-6
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 29
29
Assembly drawing Airtronic / Airtronic M
Partslist
1 Combustionairfan 2 Seal–combustionairfan/heatexchanger 3 Combustionchamber 4 Seal–combustionchamber/heatexchanger 5 Heatexchanger 6 Controlbox 7 Combinationsensor(overheating/flamesensor)with
assemblytool
8 Bracket 9 Glowplug,withspecialtool(SW12)10 Lining–glowplugsocket,withassemblytool11 Cover12 Outershell(bottomsection)13 Flangeseal14 Sleeve(forpetrolonly)
Repairinstructions5
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 30
30
Repair step 1Remove the heater’s cover (seeFigure1)
Unlockbothfasteningclips,liftthecoverandremovefromthefront.
Theheater’scovermustberemovedforallrepairsteps.Ifnecessary,waituntiltheunithascooleddown.
Cableharnessoutletfromthehousingoptionallyonleftorright-handside.
1. 2.
Figure1
Cover Fasteningclips
Repair step 2Dismantle control box (seeFigure2)
• Repairstep1.• Unscrewfixingscrew,• Presstogethertheretainingclamps.• Removethecontrolboxfromabove.• Unclipcablesfromholderoncontrolbox (Notethepositionofthecables).• Pullgrommetoutoftheoutershell(bottomsection).• Pullconnectoroutofcontrolbox,thecontrolboxcannowberemoved.
Whenassemblingthecontrolbox,ensurethecablesareclip-pedintotheholderonthecontrolboxandtheconnectorsarepluggedintothecontrolbox(unmistakeable).TighteningtorqueofthefixingscrewItem:2+0.2Nm
Figure2
Fixingscrew Retainingclamp Controlbox Grommet
Check control box
TheEDiTHdiagnostictoolisrequiredtocheckthecontrolboxwhenitisdismantled.Forconnection,useandOrderNo.,seePage19.
5 Repairinstructions
Please note!
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 31
31
Repair step 3Dismantle glow plug (seeFigure3)
• Repairstep2.• Disconnectconnectorfrom“glowplug”cableloomoncon-trolbox.
• Removerubbergrommetandunscrewtheglowplugusingthespecialtool(SW12).
(Thespecialtoolisincludedwiththeglowplug).
Tighteningtorqueforglowplug:6+0.5Nm
Specialglowplugtool
Withtheglowplugdismantled,visuallycheckthesocketliningoftheinstalledglowplugfordirt.Iftheliningishighlysoiledanditssurfaceclosed,renewthelining.
Figure3
Glowplug Connectorfromglowplugcableloom Rubbergrommet
Removing the lining (see Figure 4)
Uselongnoseplierstopulltheliningoutofthesocketfromabove.Blowoutthesocketwithcompressedairandifnecessarycleanthesideventhole.
Usethespecialtooltoinstallthenewlining.Thespecialtoolisincludedwiththelining.Pushtheliningonthetool.Pushinthetooltogetherwiththelininguptothelimitstop.
Figure4
Specialtool Lining
5
Repairinstructions
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 32
32
Repair step 5 Dismantle combination sensor (overheating / flame sen-sor) (seeFigure5)
• Repairstep2.• Removebothconnectorsfromthe“combinationsensor”cableloomatthecontrolbox.
• Unlockbracketfromcombinationsensor.• Removethecombinationsensor.
Figure5
“Combinationsensor”cableloom Bracket,unlocked
Check combination sensor
Theexternaltemperaturesensormustbecheckedwithadig-italmultimeter.Replacetheoverheatingorflamesensoriftheresistancevalueisnotthesameasthecurveinthediagramorthetableofvalues.
Table of overheating sensor values
Temperature °C Resistance k min. max. – 40 1597.00 1913.00 – 20 458.80 533.40 0 154.70 175.50 20 59.30 65.84 40 25.02 28.04 60 11.56 13.16 80 5.782 6.678 100 3.095 3.623 120 1.757 2.081 140 1.050 1.256 160 0.6554 0.792 180 0.4253 0.5187 200 0.2857 0.3513
Table of flame sensor values
Temperature °C Resistance min. max.– 40 842.7 825.9 859.6– 20 921.6 803.2 940.0 0 1000.0 980.0 1020.0 20 1077.9 1056.4 1099.5 40 1155.4 1132.3 1178.5 60 1232.4 1207.8 1257.1 80 1308.9 1282.8 1335.1 100 1385.1 1357.4 1412.8 120 1460.7 1431.5 1489.9 140 1535.8 1505.1 1566.6 160 1610.5 1578.3 1642.8
Resistance(kOhm)
Temperature(°C)
5
Notethemax.temperatureof320°Cforthetest.
Temperature(°C)
Resistance(Ohm)
Overheating sensor Flame sensor
Repairinstructions
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 33
33
Sketch2
Specialtool–onlyrequiredforAirtronic Combinationsensor
Figure6
Specialtool–onlyrequiredforAirtronic Combinationsensor
Repair step 6 Install combination sensor (overheating / flame sensor)(seeFigure6,7andSketch2–4)
•Repairstep2.• ForAirtronic(assemblywithspecialtool,seeSketch2) Pushthespecialtoolaontothecombinationsensorb.Usethespecialtooltopositionthecombinationsensorontheheatexchanger,thespecialtoolslidesontheheatexchang-eruntilthecombinationsensorhitsthecollar(installationpositionofthecombinationsensor).
Lockthecombinationsensor’sbracketandremovethespecialtool.Thenalwayscheckthatthecombinationsen-sorsitsflatontheheatexchanger.Ifnecessary,useaidssuchasamirrorandlamp.
Laythe“combinationsensor”cableloomalongthebracket,throughthebracketeyeletuptothecontrolboxandcon-nect.
• ForAirtronicM(assemblywithoutspecialtool) Placethecombinationsensorontheheatexchanger;itisimportanttoensurethecombinationsensorsitsflatontheheatexchanger.
Lockthecombinationsensor’sbracketandcheckagainthatthecombinationsensorissittingflatontheheatex-changer.
Laythe“combinationsensor”cableloomalongthebracket,throughthebracketeyeletuptothecontrolboxandcon-nect.
Sketch4
Bracket Combinationsensor
Figure7
Bracket,locked “Combinationsensor”cableloom Specialtool–onlyrequiredforAirtronic
Circuit diagram for combination sensor (overheating sensor / flame sensor)
Sketch3
NTC50KΩ=overheatingsensorPT1000=flamesensor
Connectorblue
Connectorgreen
5 Repairinstructions
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 34
34
Repair step 7 Dismantle heat exchanger (seeFigure8andSketch5)Dismantle combustion air fan (seeFigure8andSketch5)
• Repairstep2.• Removeflangeseal.Removeheaterfromtheoutershell(bottomsection).
Unscrewthe4fixingscrewsfromthecombustionairfan. Removethecombustionairfanandthesealfromtheheatexchanger.
Caution!Wheninstallingthecombustionairfanthesealmustalwaysberenewed.
Tightenthe4fixingscrewsofthecombustionairfan–intheordershowninSketche–withatighteningtorqueof4+0.5Nm. Figure8
Combustionairfan Heatexchanger Fixingscrew
Sketch5
1–4 Tightenthefixingscrewsinthisorderwithatightening
torqueof4+0.5Nm
5
5 Alwaysrenewthesealbetweenthecombustionairfanandtheheatexchanger.
5
2
4
3
1
Repairinstructions
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 35
35
Repair step 8Dismantle combustion chamber (seeFigure9andSketch6)
• Repairstep3.• Repairstep7.• Unscrewthefixingscrews. IntheAirtronic=3fixingscrews, intheAirtronicM=4fixingscrews.• Pulloutthecombustionchamberfromthefrontandremovetheheatexchanger’sseal.
Caution!Whenassemblingthecombustionchamber,alwaysrenewtheseal,whichisincludedwiththesparepart.
Tightenthefixingscrewsofthecombustionchamberwithatighteningtorqueof5+0.5Nm
Iftheheatexchangerisreplacedthecombinationsensor(overheatingsensor/flamesensor)mustbedismantledandfittedonthenewheatexchanger(seeRepairstep6,Page33).
Sketch6
1Combustionchamber2Alwaysrenewthesealbetweenthecombustionchamberandtheheatexchanger.
3Heatexchanger
4Fixingscrew Airtronic=3fixingscrews AirtronicM=4fixingscrews
Figure9
Combustionchamber Heatexchanger Fixingscrew Airtronic=3fixingscrews AirtronicM=4fixingscrews
5
4
1
2
3
Repairinstructions
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 36
36
Measuring the fuel quantity
1. Preparation
Removethefuelpipeattheheaterandinsertameasuringcylinder(size10ml).Switchontheheater,ifthefuelisuniformlypumped(beginsapprox.60secafterbeingswitchedon),thefuelpipeisfullandvented.Switchoffheaterandemptymeasuringcylinder.
Forprecisefuelmeasurementatleast11volt/22voltormaximum13volt/26voltshouldbeappliedtothecontrolboxduringthemeasurement.
2. Measurement
Thefuelbeginstobepumpedapprox.60secafterswitchingontheheater.Holdthemeasuringcylinderatglowpluglevelduringthemeasurement.
Airtronic Afterapprox.90secofthefuelbeingpumpeditisautomati-callyswitchedoff.
Caution!Switch off heater,asotherwiseitwillstartupagain.
Readoffthequantityoffuelinthemeasuringcylinder.
Airtronic MAfterapprox.105secofthefuelbeingpumpeditisautomati-callyswitchedoff.
Caution!Switch off heater,asotherwiseitwillstartupagain.
Readoffthequantityoffuelinthemeasuringcylinder..
Ifthemeasuredfuelquantityliesoutsidethevaluesgivenbelow,themeteringpumpmustbereplaced.
1 Heater2 Meteringpump
Check fuel supply
Beforemeasuringthefuelquantity,checkthefollowingpointsinthefuelsupply.
• Checkthescreeninthemeteringpump.• Checkthelayingofthefuelpipes.• Checkfuelpipesforleaks.• Checkandtightenthehoseconnections.• Isthefuelremovalinstalledaccordingtothedetailsinthetechnicaldescription?
5
3 Measuringcylinder(size10ml)4 Disconnectfuelpipeatheaterandinsertinameasuringcylinder.
1
2
3
4
Table of values – fuel quantity
Heater Fuel Fuel quantity
Minimal Maximal
Airtronic diesel 3,5ml/90sec 4,3ml/90sec
AirtronicM petrol 6,8ml/105sec 7,6ml/105sec
AirtronicM diesel 5,0ml/105sec 6,0ml/105sec
Bitte beachten!
Repairinstructions
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 37
37
Circuitdiagram6Overview of the parts lists and circuit diagrams
PartslistcircuitdiagramAirtronic/AirtronicM................................................................................................................................ 38CircuitdiagramAirtronic/AirtronicM.............................................................................................................................................. 39 Thiscircuitdiagramisforheaterswithonediagnosticscableandacontrolboxcableloomwhichisfirmlyencapsulated.CircuitdiagramAirtronic/AirtronicM.............................................................................................................................................. 40 Thiscircuitdiagramisforheaterswith2diagnosticscableandwhosecontrolboxcableloomiswoundwithcabletape.
Partslistcontrolunits..................................................................................................................................................................... 41Circuitdiagramscontrolunits...................................................................................................................................................42–48
PartslistEasyStartR+/R/Tcontrolunits..................................................................................................................................... 49EasyStartR+circuitdiagram...................................................................................................................................................50–52EasyStartRcircuitdiagram......................................................................................................................................................53–55EasyStartTcircuitdiagram....................................................................................................................................................... 56,57
PartslistcircuitdiagramAirtronic/AirtronicM–ADR..................................................................................................................... 58CircuitdiagramAirtronic/AirtronicM–ADR................................................................................................................................... 59 Thiscircuitdiagramisforheaterswithonediagnosiscableandacontrolboxcableloomwhichisfirmlyencapsulated.CircuitdiagramAirtronic/AirtronicM–ADR................................................................................................................................... 60 Thiscircuitdiagramisforheaterswith2diagnosticscableandwhosecontrolboxcableloomiswoundwithcabletape.
Partslistcontrolunits–ADR.......................................................................................................................................................... 61Circuitdiagramcontrolunits–ADR............................................................................................................................................... 62EasyStartT–ADRcircuitdiagram............................................................................................................................................ 63,64
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 38
38
Parts list circuit diagrams Airtronic / Airtronic M
1.1 Burnerengine1.2 Glowplug1.5 Overheatingandflamesensor2.1 Controlbox2.2 Meteringpump2.7 Mainfuse 12volt=20A 24volt=10A2.7.1Fuse,actuation5A5.1 Battery
a) Connectionofcontrolunitandexternalsensoraccord-ingto“controlunits”circuitdiagram
•rt Powersupply,plus–terminal30 •ge Switch-onsignal–S+ •gr Temperature–actualvalue •wsrt Switchofftheanti-theftalarmsystem (ADR–feedbacksignalfortimer) •br Powersupply,minus–terminal31 •blws Diagnosis •grrt Temperature–setpoint •brws Groundconnectionforexternaltempera-
turesensorandtemperaturesetpoint b) Option •Vehiclefancontrol and/or •separatefreshairfan
Thecircuitdiagramsareassignedviatheinstalledcontrolbox:• Controlboxwithonediagnosticscable: Atthe16pinconnectorthediagnosticscablebl/wsiscon-nectedtochamber8.
• Controlboxwith2diagnosticscablesandJEdiagnosis: Atthe16pinconnectorthediagnosticscablebl/wsisconnectedtochamber3,thediagnosticscablebl/geisconnectedtochamber8.
• Insulateunusedcableends.• Connectorsandbushhousingsareshownfromthecableinletside.
Circuitdiagram6
Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 39
39
Circuit diagram – Airtronic / Airtronic M
252069009801APartslistPage38
Circuitdiagram6
Thiscircuitdiagramisforheaterswithadiagnosticscableandwhosecontrolboxcableloomwhichisfirmlyencapsulated.
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 40
40
Circuit diagram – Airtronic / Airtronic M
Circuitdiagram6
Thiscircuitdiagramisforheaterswith2diagnosticscableandwhosecontrolunitcableloomiswoundwithcabletape.
252069009801BPartslistPage38
Bitte beachten!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 41
41
Circuitdiagram6Parts list circuit diagrams, control units
2.15.1 Temperaturesensor,external(roomtemperature)2.15.9 Temperaturesensor(externaltemperature)3.1.9 Changeoverswitch“heat/ventilate”3.1.11 Controlunit,round3.1.16 Radioremotecontrolbutton3.1.17 MinicontrollerAirtronic3.1.18 ButtonCalltronic3.2.8 Moduletimer(ADR–potentiometer)3.2.12 Timer,mini–12/24volt3.2.14 Lighting,timer,mini–12voltonly3.3.6 RadioremotecontrolstationarypartTP41i3.3.7 RadioremotecontrolstationarypartTP53.3.8 RemotecontrolCalltronic3.8.3 Antenna3.9.1 Diagnosis,JEdiagnosis
a)ConnectioncontrolelementstotheAirtronic •rt Powersupply,plus–terminal30 •ge Switch-onsignal–S+ •gr Temperature–actualvalue •wsrt Switchoffburglaralarm (ADR–feedbackfortimer) •br Powersupply,minus–terminal31 •blws Diagnosis •grrt Temperature–setpoint •brws Groundconnectionforexternaltempera-
turesensorandtemperaturesetpoint b) Terminal15–necessaryforconnectionTP4i c) Lighting,terminal58d) Connection,diagnosticunit e) Connection,externaltemperaturesensor g) Connection,externalheatingbutton h) Connection,radioremotecontrolTP4i j) Connection,temperaturesensor(outsidetemperature) k) Ifconnectingtimerorradioreceiver– Disconnectcablehere l) Connection,change-overswitch“heat/ventilate” option) Initialoperation:Activatechangeoverswitch “heat/ventilate”,thenswitchontheheater. z) Lighting,terminal58
• Insulateunusedcableends.• Connectorsandbushhousingsareshownfromthecableinletside.
Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 42
42
Circuit diagram, control units – part 1
252069009701CPartslistPage41
Circuitdiagram6
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 43
43
Circuitdiagram6
252069009701CPartslistPage41
Circuit diagram, control units – part 2
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 44
44
Circuit diagram, control units – part 3
252069009702APartslistPage41
Circuitdiagram6
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 45
45
Circuit diagram, control units – part 4
252069009702APartslistPage41
Circuitdiagram6
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 46
46
Circuit diagram, control units – part 5
252069009704APartslistPage41
Circuitdiagram6
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 47
47
Circuit diagram, control units – part 6
252069009704APartslistPage41
Circuitdiagram6
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 48
48
Circuit diagram, control units – part 7
PartslistPage41
Circuitdiagram6
252069009703B
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 49
49
Circuitdiagram6Parts list circuit diagram control units – EasyStart R+ / R / T
2.15.1 Temperaturesensor(roomtemperature) (includedinscopeofsupplyforEasyStartR+, optionalforEasyStartR/T)2.15.9 Outsidetemperaturesensor(optional)
3.1.7 “OFF”button3.1.9 “Heat/ventilate”switch3.1.11 “Round”controlunit3.1.16 Radioremotecontrolbutton3.1.17 “Minicontroller”controlunit
3.2.15 EasyStartTtimer
3.3.9 RadioremotecontrolEasyStartR(stationaryunit)3.3.10 RadioremotecontrolEasyStartR+(stationaryunit)
3.6.1 Leadharness
3.8.3 Antenna
a) Connectionofcontrolunitsattheheaterc) Terminal58(lighting)d) Parkingventilationwithvehiclefan(optional)e) ConnectionofEasyStartTtimertimerg) Connection“ON/OFF”key (optionale.g.OrderNo.:221000328400)h) Connectionof“Ventilate”viaEasyStartR+x) ADRjumpery) Connectandinsulatecables
•Note heater type!•Thejumperlabelledwithy)inthecircuitdiagrammustalways
beconnected.•Insulateunusedcableends.•Connectorsandbushhousingsareshownfromthecable
inletside.
Assignment of the circuit diagrams for Airtronic heatersThecircuitdiagramsareassignedviatheinstalledcontrolbox:• Controlboxwithonediagnosticscable: Atthe16pinconnectorthediagnosticscablebl/wsiscon-nectedtochamber8.
• Controlboxwith2diagnosticscablesandJEdiagnosis: Atthe16pinconnectorthediagnosticscablebl/wsisconnectedtochamber3,thediagnosticscablebl/geisconnectedtochamber8.
Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple
Please note!
EasyStart TPinassignmentEasyStartT-connectorS1
1 Terminal 30 (positive) rt 2 S+(switchingonsignal) ge 3 Terminal 31 (negative) br 4 DATcable vi 5 Diagnosis cable (K line) bl/ws 6 Terminal58 gr/sw 7 Temperaturesensor(positive)) gr 8 Temperaturesensor(negative) br/ws 9 –– ––
EasyStart R Pinassignmentatthestationaryunitconnector
1 Terminal31(negative) 2 –– 3 –– 4 DATcable 5 Pushbutton/LED(negative) 6 –– 7 Terminal30(positive) 8 S+(switching on signal) 9 LED(positive)10 Diagnosiscable(Kline))11 Pushbutton(negative)12 ––
EasyStart R+ Pinassignmentatthestationaryunitconnector
1 Terminal31(negative) 2 –– 3 Ventilate(switchingsignal–) 4 DATcable 5 Pushbutton/LED(negative) 6 Temperaturesensor(negative) 7 Terminal30(positive) 8 S+(switchingonsignal) 9 LED(positive)10 Diagnosiscable(Kline)11 Pushbutton(negative)12 Temperaturesensor(positive)
Pin assignments
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 50
50
Circuitdiagram6EasyStart R+ control unit circuit diagram(Controlboxwithonediagnosticscable)
PartslistPage49 252069009706B
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 51
51
Circuitdiagram6
PartslistPage49 252069009706B
EasyStart R+ control unit circuit diagram(Controlboxwithonediagnosticscable)
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 52
52
Circuitdiagram6EasyStart R+ control unit circuit diagram(Controlboxwithtwodiagnosticscables)
PartslistPage49 252361009701B
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 53
53
Circuitdiagram6EasyStart R control unit circuit diagram(Controlboxwithoneortwodiagnosticscables)
PartslistPage49 252361009705B
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 54
54
Circuitdiagram6EasyStart R control unit circuit diagram(Controlboxwithtwodiagnosticscables)
PartslistPage49 252361009702B
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 55
55
Circuitdiagram6EasyStart R control unit circuit diagram(Controlboxwithonediagnosticscable)
PartslistPage49 252069009707B
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 56
56
Circuitdiagram6EasyStart T control unit circuit diagram(Controlboxwithonediagnosticscable)
PartslistPage49 252069009708
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 57
57
Circuitdiagram6EasyStart T control unit circuit diagram(Controlboxwithtwodiagnosticscables)
PartslistPage49 252361009703
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 58
58
Circuitdiagram6Parts list circuit diagrams Airtronic / Airtronic M – ADR
1.1 Burnerengine1.2 Glowplug1.5 Overheatingandflamesensor2.1 Controlbox2.2 Meteringpump2.7 Mainfuse 12volt=20A 24volt=10A2.7.1Fuse,actuation5A5.1 Battery5.2.1Operatingswitchbatteryd) (operationcontrollede.g.viaignitionlock) EmergencyofffunctionforADR–Item5.2.2–5.55.2.2Isolatingswitchbatteryd)5.3 AuxiliarydriveHA+5.3.1Switch,auxiliarydrive5.5 GeneratorD+
a) Connectionofcontrolunitandexternalsensor correspondingto“controlunits”circuitdiagram •rt Powersupply,plus-terminal30 •ge Switch-onsignal-S+ •gr Temperature-actualvalue •wsrt Switchofftheanti-theftalarmsystem (ADR–feedbacksignalfortimer) •br Powersupply,minus-terminal31 •blws Diagnosis •grrt Temperaturesetpointvalue •brws Groundconnectionforexternal
temperaturesensorandtemperature setpoint
b) Option •Vehiclefancontrol and/or •separatefreshairfan c) WiringforoperationwithADR(hazardousgoodstrans-
portinutilityvehiclesegment,e.g.tanker)
d) Ifonlyoneswitchingelementisusedforitems5.2.1and5.2.2,itisimportanttoensurethatonactivatingthe“openthebatteryisolatingswitch”function(EMERGEN-CYOFFfunctioninADR,etc.),theswitchalwaysbreakscontactimmediately(regardlessoftheheatercondition)andalltheheater’scircuitsaredisconnectedfromthebattery.
• Note heater type! • Thejumperlabelledwithy)inthecircuitdiagrammustalwaysbeconnected.
• Insulateunusedcableends.• Connectorsandbushhousingsareshownfromthecableinletside.
Assignment of the circuit diagrams for Airtronic heatersThecircuitdiagramsareassignedviatheinstalledcontrolbox:• Controlboxwithonediagnosticscable: Atthe16pinconnectorthediagnosticscablebl/wsiscon-nectedtochamber8.
• Controlboxwith2diagnosticscablesandJEdiagnosis: Atthe16pinconnectorthediagnosticscablebl/wsisconnectedtochamber3,thediagnosticscablebl/geisconnectedtochamber8.
Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple
Please note!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 59
59
Circuit diagram – Airtronic / Airtronic M – ADR
252069009601BPartslistPage58
Circuitdiagram6
Thiscircuitdiagramisforheaterswithonediagnosticscableandwhosecontrolboxcableloomisfirmlyencapsulated.
Bitte beachten!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 60
60
Circuit diagram – Airtronic / Airtronic M – ADR
Circuitdiagram6
PartslistPage58 252069009601C
Thiscircuitdiagramisforheaterswith2diagnosticscableandwhosecontrolboxcableloomiswoundwithcabletape.
Bitte beachten!
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 61
61
Circuitdiagram6Parts list circuit diagrams control unit EasyStart T – ADR
3.1.7 “OFF”button3.1.17 “Minicontroller”controlunit
3.2.15 TimerEasyStartT
a) Connectionofcontrolunitsattheheaterg) Connection“ON/OFF”key (optionale.g.OrderNo.:221000328400)x) ADRjumpery) Connectandinsulatecables
• Thejumperlabelledwithy)inthecircuitdiagrammustalwaysbeconnected.
• Insulateunusedcableends.• Connectorsandbushhousingsareshownfromthecableinletside.
Assignment of the circuit diagrams for Airtronic heatersThecircuitdiagramsareassignedviatheinstalledcontrolbox:• Controlboxwith2diagnosticscablesandJEdiagnosis: Atthe16pinconnectorthediagnosticscablebl/wsisconnectedtochamber3,thediagnosticscablebl/geisconnectedtochamber8.
• Controlboxwithonediagnosticscable: Atthe16pinconnectorthediagnosticscablebl/wsiscon-nectedtochamber8.
Parts list circuit diagram control units – ADR
2.15.1 Temperaturesensor,external(roomtemperature)
3.1.11 Controlunit,round3.1.17 MinicontrollerAirtronic
3.2.8 Moduletimer(ADR–potentiometer)
3.9.1 Diagnosis,JEdiagnosis
a) ConnectioncontrolelementstotheAirtronic •rt Powersupply,plus–terminal30 •ge Switch-onsignal–S+ •gr Temperature–actualvalue •wsrt Switchoffburglaralarm (ADR–feedbackfortimer) •br Powersupply,minus–terminal31 •blws Diagnosis •grrt Temperature–setpoint •brws Groundconnectionforexternal
temperaturesensorandtemperature setpoint
b) Terminal15 c) Lighting,terminal58d) Connection,diagnosticunit e) Connection,externaltemperaturesensor
• Insulateunusedcableends.• Connectorsandbushhousingsareshownfromthecableinletside.
Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple
Please note!
Please note!
Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 62
62
252069009901B
Circuit diagram, control units – ADR
PartslistPage61
Circuitdiagram6
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 63
63
Circuitdiagram6Circuit diagram, control unit EasyStart T – ADR(Controlboxwithonediagnosticscable)
252069009709PartslistPage61
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 64
64
Circuitdiagram6Circuit diagram, control unit EasyStart T – ADR(Controlboxwithtwodiagnosticscables)
252361009704PartslistPage61
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 65
65
Certification
ThehighqualityofEberspächer’sproductsisthekeytooursuccess.Toguaranteethisquality,wehaveorganisedallworkproc-essesinthecompanyalongthelinesofqualitymanagement(QM).Evenso,westillpursuealargenumberofactivitiesforcon-tinuousimprovementofproductqualityinordertokeeppacewiththesimilarlyconstantlygrowingrequirementsmadebyourcustomers.Allthestepsnecessaryforqualityassurancearestipulatedininternationalstandards.Thisqualityistobeconsideredinatotalsense.Itaffectsproducts,proceduresandcustomer/supplierrela-tions.Officiallyapprovedpublicexpertsassessthesystemandthecorrespondingcertificationcompanyawardsacertificate.
Eberspächerhasalreadyqualifiedforthefollowingstandards:
Quality management in accordance with DIN EN ISO 9001:2000 and ISO/TS 16949:1999
Environmental management system in accordance withDIN EN ISO 14001:1996
Disposal
Disposal of materialsOlddevices,defectcomponentsandpackagingmaterialcanallbeseparatedandsortedintopure-gradefactionssothatallpartscanbedisposedofasrequiredinanenvironment-friendlymannerrecycledwhereapplicable.Electricmotors,controlboxesandsensors(e.g.temperaturesensors)aredeemedtobe“electronicscrap”.
Dismantling the heaterTheheaterisdismantledaccordingtotherepairstagesinthecurrenttroubleshooting/repairinstructions.
PackagingThepackagingoftheheatercanbekeptincaseithastobesentback.
EC Declaration of Conformity
Withregardtothefollowingproducts
Heater type Airtronic / Airtronic M
weherewithconfirmthatitconformswiththeprimesafetyrequirementsstipulatedinthedirectivesoftheEUCouncilforharmonisationofthelegalregulationsofthememberstateswithregardtoelectromagneticcompatibility(89/336/EEC).ThisdeclarationappliestoallheatersproducedaccordingtotheproductiondrawingsAirtronic/AirtronicM–whichareanintegralpartofthisdeclaration.Thefollowingstandards/directiveshavebeenusedtoassesstheproductwithregardtoelectromagneticcompatibility:• EN50081–1Basicforminterferenceemission• EN50082–1Basicformofinterferenceimmunity• 72/245/EEC–Modificationstatus2006/28/EC. Interferencesuppressioninmotorvehicles.
Service7
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 66
66
Service7Representatives abroad
ArgentinaChampionS.A.Mejico3941VillaMatelliRA-1603BuenosAiresTel.0054/1149439900Fax.0054/1147090224
for boat heatersTrimerS.A.DelAreaSanFernandoRA-1000BuenosAiresTel.0054/1145800444Fax.0054/1145800440
Belgium & LuxemburgEbercabvbalResearchParkHaasrodeEsperantolaan2B-3001LeuvenHaasrodeTel.0032/16-402500Fax.0032/16-400515
ChileforboatheatersNauticentroLtda.TomasMoro135LasCondes-SantiagoTel.0056/2-2014966Fax.0056/2-2015635
People's Republic of ChinaEberspaecherAutomotiveTechnology(Beijing)Co.,Ltd.B1-1XinchengIndustrialParkKechuangStreetNo.2,BDABeijing100023People'sRepublicofChinaTel.00861067892686Fax.00861067892636
DenmarkEberspächerDanmarkLiterbuen9DK-2740SkovlundeTel.0045/44-853030Fax.0045/44-853039
EstoniaSoeAutoOÜLüli1EE-10112TallinnTel.00372/3848890Fax.00372/3848892
FinlandWihuriOyAutolaManttaalitie9SF-01510Vantaa51Tel.0035820510-10Fax.0035820510-2207
FranceEberspächerS.A.S.Z.A.C.laCléSaintPierre3rueBlaisePascalF-78996ElancourtCedexTel.0033-1-30685454Fax.0033-1-30685455
GreeceMARCONIHELLASS.A.Souliou2–4GR14343N.CalkidonaAthensTel.0030/2102513500Fax.0030/2102528854
Great BritainEberspächerUKLtd.HeadlandsBusinessParkSalisburyRoad,RingwoodGB-HampshireBH243PBTel.0044/1425-480151Fax.0044/1425-480152
Sales partners in Great Britain
AustraliaDometicPtyLtd6TreforestDriveClayton,Victoria3168Tel.+61395455655Fax.+61395455966
New ZealandDometicNewZealandLtd26CashewStreetGrenadaNorth,WellingtonTel.+6442323898Fax.+6442323878
ItalyEberspaecherS.r.l.ViadelCanneto45I-25010Borgosatollo(BS)Tel.0039/03025076-1Fax.0039/030250030
JapanWhiteHouseCo.,Ltd.10-4Obata-MiyanokosiMoriyama-KuNagoya463-0052JPTel.0081527763811Fax.0081527763855
CanadaEsparProductsInc.6099AVipondDriveCDNMississaugaOntarioL5T2B2Tel.001/9056700960Fax.001/9056700728
LatviaTransBalticTradingCorporationMaskavasiela449LV-1063RigaTel.00371/7266323Fax.00371/7187967
LithuaniaUABLeopolisPaneriu51LIT-2055VilniusTel.0037052-330457Fax.0037052-133537
Republic of MoldaviaTC-IUSTINIAN140HinchestiStr.,of.9MD-2070KishinevTel.003732/727883,738710Fax.003732/727883
NetherlandsEbercaB.V.Marconistraat2NL-3281NBNumansdorpTel.0031/186-621955Fax.0031/186-621818
NorwayEberspächerNorgeTrollåsveien34N1414TrollåsenTel.0047/66823050Fax.0047/66823058
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 67
67
Service7Representatives abroad
Dated10.2007
PolandEberspächerSp.zo.oWysogotowoK.Poznaniaul.Okrezna17PL-62081PrzezmierowoTel.0048/61-8161850Fax.0048/61-8161860
RussiaJSC OTEMВерхняя Красносельская улица 2RUS 107140 MoscowTel. 007 (495) 645 59 79Fax. 007 (495) 647 13 24
SwedenEberspächerABBox2103S-12823SkarpnäckTel.0046/86831134Fax.0046/87249040
SwitzerlandTechnomagAGFischermättelistr.6Ch-3008BernTel.0041-313798121Fax.0041-313798250
SloveniaEberspaecherGesellschaftm.b.H.PodružnicaSLOCelovškacesta2281000LjubljanaTel.00386/15187052Fax.00386/15187053
Spain – PortugalPedroSanzClimaS.LAvda.IngenieroTorresQueredo,6E-28022MadridTel.0034917613830Fax.0034913294231
South KoreaE-ConEnterpriseInc.SeoulBranchOffice4F,YeokSanBldg.#43-1,SamsungDongKangnam-Gu,Seoul135-091SouthKoreaTel.0082025588826Fax.0082025528788
AustriaEberspächerGmbHIZNÖ-Süd2,Hondastraße2,Obj.M47A-2351WienerNeustadtTel.0043/2236677144-0Fax.0043/2236677144-42
Sales partners in Austria
BulgariaProMobile13,IskarskoChausseeBlvd.BG-1592SofiaTel.+35929601414Fax.+35929734636
Stankoff&SonSehovo18BG-1309SofiaTel.+35929208450Fax.+35929208451
Croatia, Bosnia-HerzegovinaTermobild.o.o.KukuljanovobbHR-51233SkrljevoTel.0038551251-935Fax.0038551251-334
RumaniaCEFINRomaniaS.R.L.ItalieiStr.,Com.Chiajna,1-7Jud.IlfovRO-077040BucharestTel.+44741841200Fax.+44741841222
TermoportSos.Bucurestinr.314(DJ601)RO-077055Ciorogarla,IlfovTel.+40213143555Fax.+40213143565
FOMCOSRLRâtulMorii1295RO-547530SângeorgiudeMuresTel./Fax.+40265318008/+40744396653+40726194558/+40788473099
Dated12.2008
Czech RepublicEberspächerPrahasr.o.AREÁLZÁLESÍPodVišňovkou29CZ-14000Praha4–KrčTel.00420/234035800Fax.00420/234035810and820
Sales partners in Czech Republic
SlovakiaMOLPIR,s.r.o.Hrachova30SK-82105BratislawaTel.00421/243191218,43191219Fax.00421/243191220
TurkeyASCAOtomotivLtd.Sti.IkitelliOrganizeSanayiBölgesiDolapdereSanayiSitesi1.AdaNo.38TR-34760Ikitelli/IstanbulTel.0090212-5498631Fax.0090212-5493347
HungaryAustropannonKFTFöut96H-9081GyörujbaratTel.0036/96-543333Fax.0036/96-456481
UkraineGeruk+Kul.Dobrovolskogo3/4UA-18006TscherkassyTel.0038/0472310800Fax.0038/0472310801
BelarusBelvneshinvestPer.1-yiIzmajlowskij.51/2BY-220131MinskTel.00375/172371437Fax.00375/172371716
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 68
68
Service7List of key words / A – Z index
AAccidentprevention...............................................................4ADR..........................................................................7,59,69Alwaysobservethefollowingsafetyinstructionsbeforework-ingontheheater.................................................................28AMPreleasetool.................................................................28Assemblydrawing...............................................................29Assignmentofthecircuitdiagrams......................................49
Bbasicadapter......................................................................19
CCancelthecontrolboxlock...........................................16,20cancelthecontrolboxlock..................................................17Certification.........................................................................65Checkcombinationsensor..................................................32Checkfuelsupply................................................................36Checkvalues.......................................................................12Circuitdiagram....................................................................37Circuitdiagram,controlunits...............................................42Controlandsafetydevices.....................................................7Controlintheheatingmode...................................................6Cutawayview........................................................................5
DDescriptionoffunctions.........................................................6Diagnosticunit.....................................................................15Disposal..............................................................................65
EEasyStartR+radioremotecontrol.......................................22EasyStartTtimer.................................................................22ECDeclarationofConformity...............................................65ECtype-approval.................................................................69EDiTHdiagnostictool....................................................17,19EMCdirective......................................................................69EMERGENCYOFF................................................................7Emergencyshutdown............................................................7
FFAME..................................................................................69Faultcode...........................................................................23Faultdescription..................................................................23Forcedshut-down.................................................................7Foreword...............................................................................4
IImportantinformation............................................................4ISOadapter.........................................................................17
LListofabbreviations.............................................................69
MMeasuringthefuelquantity..................................................36Moduletimer.......................................................................20
OOverviewofthepartslistsandcircuitdiagrams....................37
PPartslistcircuitdiagramcontrolunits...................................49Partslistcircuitdiagramcontrolunits–ADR........................61Partslistcircuitdiagrams...............................................38,58Partslistcircuitdiagrams,controlunits................................41
RRepairinstructions.........................................................28,30Representativesabroad.................................................66,67
SService................................................................................65Specialtool..........................................................................28StartingAirtronic...................................................................6StartingAirtronicM................................................................6Switchingoff..........................................................................6Switchingon..........................................................................6
TTableofflamesensorvalues................................................32Tableofoverheatingsensorvalues......................................32Tableofvalues–fuelquantity..............................................36Technichaldata.....................................................8,9,10,11Temperatureselection............................................................6Testingdeviceforthecontroldevice....................................15TP5radioremotecontrol.....................................................21Troubleshooting...................................................................13
VVentilatingmode....................................................................6
WWhattocheckfirst..............................................................13
Keyword Page Keyword Page
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 69
69
Service7List of abbreviations
ADREuropeanagreementabouttheinternationaltransportofdan-gerousgoodsontheroad.
EC type-approvalPermitawardedbytheFederalVehicleOfficefortheproduc-tionofaheaterforinstallationinmotorisedvehicles.
EMC directiveElectromagneticcompatibility.
JE-PartnersJ.Eberspächerpartner.
FAME (biodiesel)FAMEfordieselenginesaccordingtoDINEN14214.
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com
Page 70
www.eberspaecher.com252115951901EN04.2009ÄnderungenvorbehaltenPrintedinGermany©J.EberspächerGmbH&Co.KG
J.EberspächerGmbH&Co.KGEberspächerstraße24D-73730EsslingenTelephone0711939-00Facsimile0711939-0643info@eberspaecher.com
Visit www.butlertechnik.com for more technical information and downloads.
www.butlertechnik.com