Top Banner
Airtronic M Order no. Airtronic D3, 12 V 25 2317 05 00 00 Airtronic B4, 12 V 20 1812 05 00 00 Airtronic D4, 12 V 25 2113 05 00 00 Airtronic D4, 24 V 25 2114 05 00 00 Airtronic D4 Plus, 12 V 25 2484 05 00 00 Airtronic D4 Plus, 24 V 25 2498 05 00 00 Airtronic D4S, 12 V 25 2144 05 00 00 Airtronic D4S, 24 V 25 2145 05 00 00 Airtronic D3 Camper, 12 V (see Airtronic D3) Airtronic D4 Camper, 12 V 25 2318 05 00 00 Airtronic D4 Camper plus, 12 V 25 2327 05 00 00 AIRTRONIC / AIRTRONIC M Troubleshooting and Repair Instructions 25.2115.95.1901 01.2019 Airtronic Airtronic D2, 12 V Airtronic D2, 24 V Airtronic D2 Camper, 12 V Complete package Airtronic D2, 12 V Airtronic D2, 24 V Order no. 25 2069 05 00 00 25 2070 05 00 00 25 2326 05 00 00 25 2675 05 00 00 25 2676 05 00 00 Air heater for diesel and petrol operating independently of the engine.
68

AIRTRONIC / AIRTRONIC M...AIRTRONIC / AIRTRONIC M Troubleshooting and Repair Instructions 25.2115.95.1901 01.2019 Airtronic Airtronic D2, 12 V Airtronic D2, 24 V Airtronic D2 Camper,

Jan 27, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • Airtronic M Orderno.

    AirtronicD3,12V 252317050000

    AirtronicB4,12V 201812050000

    AirtronicD4,12V 252113050000AirtronicD4,24V 252114050000

    AirtronicD4Plus,12V 252484050000AirtronicD4Plus,24V 252498050000

    AirtronicD4S,12V 252144050000AirtronicD4S,24V 252145050000

    AirtronicD3Camper,12V(seeAirtronicD3)

    AirtronicD4Camper,12V 252318050000

    AirtronicD4Camperplus,12V 252327050000

    AIRTRONIC / AIRTRONIC MTroubleshooting and Repair Instructions

    25.2115.95.1901 01.2019

    Airtronic

    AirtronicD2,12VAirtronicD2,24VAirtronicD2Camper,12V

    Completepackage

    AirtronicD2,12VAirtronicD2,24V

    Orderno.

    252069050000 252070050000 252326050000

    252675050000 252676050000

    Air heater for diesel and petroloperating independently of the engine.

  • 2

    4

    3

    1

    2

    1Contents

    ThislistofcontentsgivesyoupreciseinformationaboutthecontentsoftheTroubleshootingandRepairInstructions.

    Introduction

    Usetheindex,listofabbreviations,etc,tolookforaterm,technicalwordoranexplanationforanabbreviation.

    Chapter Title Contents Page

    Introduction • Foreword.................................................................................................................. 4 • Accidentprevention.................................................................................................. 4 • Specialtextstructure,presentationandpicturesymbols........................................... 4 • Importantinformationbeforestartingwork................................................................ 4

    Function and use Cutawayview............................................................................................................ 5 • Descriptionoffunctions – Switchingon.......................................................................................................... 6 – StartingtheAirtronic.............................................................................................. 6 – StartingtheAirtronicM.......................................................................................... 6 – Temperatureselectionwiththecontrolelement...................................................... 6 – Controlinheatingmode......................................................................................... 6 – Ventilatingmode.................................................................................................... 6 – Switchingoff.......................................................................................................... 6 • Controlandsafetydevices........................................................................................ 7 – Forcedshut-downforADRoperation..................................................................... 7 – Emergencyshutdown–EMERGENCYOFF........................................................... 7

    Technical data • Airtronic(fordiesel)................................................................................................... 8 • AirtronicM(forpetrol)................................................................................................ 9 • AirtronicM(fordiesel)........................................................................................ 10,11 • Checkvalues – Testspeedfortheblower..................................................................................... 12 – Resistan\cevalues............................................................................................... 12 – Switchingvalue.................................................................................................... 12 – Exhaustemissionspecification............................................................................. 12 – Check“externaltemperaturesensor”................................................................... 12 – Tableofvalues:“Externaltemperaturesensor”..................................................... 12

    Troubleshooting • Whattocheckfirstincaseoffaults – Check.................................................................................................................. 13 – Electricalcomponents.......................................................................................... 13 – Measurebatteryvoltage....................................................................................... 13 – Measuresvoltagesupply..................................................................................... 13 – Checkswitch-onsignal........................................................................................ 13 – Checkcontrolunit................................................................................................ 13 • Overviewoftheindividualtestequipmentandcontrolunits..................................... 14 • Lockingthecontrolbox........................................................................................... 14 • Cancelthecontrolboxlock..................................................................................... 14 • Importantnotes(diagnosisofheaterswithmini-controller)....................................... 14 • Testingdeviceforthecontroldevice........................................................................ 15 • Faultdiagnosisusingthediagnosticunit........................................................... 15,16 • FaultdiagnosisusingtheEDiTHdiagnosticstoolwithISOadapter.......................... 17 • AirpressuresensordiagnosisusingEDiTHdiagnosticstoolandISOadapter.......... 18 • FaultdiagnosisusingtheEDiTHdiagnosticstoolwithbasicadapter....................... 19 • Faultdiagnosisusingthemoduletimer.................................................................... 20 • FaultdiagnosisusingtheradioremotecontrolTP5................................................. 21 • FaultdiagnosisusingtheEasyStartR+radioremotecontrolor theEasyStartTtimer............................................................................................... 22 • Faultcodetable...............................................................................................23–27

  • 3

    Introduction

    7

    6

    5

    1

    Chapter Title Contents Page

    Repair instructions • Repairinstructions.................................................................................................. 28 • Alwaysobservethefollowingsafetyinstructionsbeforeworkingontheheater........ 28 • Specialtool,AMPreleasetool................................................................................. 28 • AssemblydrawingAirtronic/AirtronicM................................................................. 29 • Repairstep1,removetheheatercover................................................................... 30 • Repairstep2,dismantlecontrolbox,checkcontrolbox......................................... 30 • Repairstep3,dismantleglowplug.......................................................................... 31 • Repairstep4,renewlining...................................................................................... 31 • Repairstep5,dismantlecombinationsensor(overheating/flamesensor............... 32 • Repairstep6,installcombinationsensor(overheating/flamesensor)..................... 33 • Repairstep7,dismantleheatexchanger/ dismantlecombustionairfan................................................................................... 34 • Repairstep8,dismantlecombustionchamber........................................................ 35 • Checkfuelsupply.................................................................................................... 36 • Measuringthefuelquantity...................................................................................... 36

    Circuit diagrams Overviewofthepartslistsandcircuitdiagrams........................................................... 37 • PartslistcircuitdiagramsAirtronic/AirtronicM....................................................... 38 • CircuitdiagramAirtronic/AirtronicM..................................................................... 39 Thiscircuitdiagramisvalidforheaterswithonediagnosiscable andacontrolboxcableloomwichisfirmlyencapsulated. • CircuitdiagramAirtronic/AirtronicM..................................................................... 40 Thiscircuitdiagramisforheaterswith2diagnosticscableandwhose controlboxcableloomiswoundwithcabletape. • Partslistcircuitdiagrams,controlunits.................................................................... 41 • Circuitdiagramcontrolunits–part1....................................................................... 42 • Circuitdiagramcontrolunits–part2....................................................................... 43 • Circuitdiagramcontrolunits–part3....................................................................... 44 • Circuitdiagramcontrolunits–part4....................................................................... 45 • Circuitdiagramcontrolunits–part5....................................................................... 46 • Circuitdiagramcontrolunits–part6....................................................................... 47 • Circuitdiagramcontrolunits–part7....................................................................... 48 • PartslistcircuitdiagramcontrolunitEasyStartR+/R/T........................................ 49 • CircuitdiagramcontrolunitEasyStartR+(controlboxwith1diagnosticscable)...... 50 • CircuitdiagramcontrolunitEasyStartR+(controlboxwith1diagnosticscable)...... 51 • CircuitdiagramcontrolunitEasyStartR+(controlboxwith2diagnosticscable)...... 52 • CircuitdiagramcontrolunitEasyStartR(controlboxwith1/2diagnosticscables). 53 • CircuitdiagramcontrolunitEasyStartR(controlboxwith2diagnosticscables)...... 54 • CircuitdiagramcontrolunitEasyStartR(controlboxwith1diagnosticscables)...... 55 • CircuitdiagramcontrolunitEasyStartT(controlboxwith1diagnosticscable)........ 56 • CircuitdiagramcontrolunitEasyStartT(controlboxwith2diagnosticscable)........ 57 • PartslistcircuitdiagramsAirtronic/AirtronicM–ADR............................................ 58 • CircuitdiagramAirtronic/AirtronicM–ADR.......................................................... 59 1encapsulateddiagnosticscableandcontrolboxcableloomfirmlyencapsulated • CircuitdiagramAirtronic/AirtronicM–ADR.......................................................... 60 2diagnosticscablesandcontrolboxcableloomwithcabletape • Partslistcircuitdiagrams,controlunits–ADR......................................................... 61 • Partslistcircuitdiagrams,controlunits–EasyStartT–ADR................................... 61 • Circuitdiagramcontrolunits–ADR......................................................................... 62 • CircuitdiagramcontrolunitEasyStartT–ADR(controlboxwith1diag.cable)....... 63 • CircuitdiagramcontrolunitEasyStartT–ADR(controlboxwith2diag.cable)....... 64

    Service • Certification............................................................................................................. 65 • Disposal.................................................................................................................. 65 • ECDeclarationofConformity.................................................................................. 65 • Listofkeywords..................................................................................................... 66 • Listofabbreviations................................................................................................ 67

  • 4

    Special text structure, presentation and picture symbols

    Specialtextformatsandpicturesymbolsareusedintheseinstructionstoemphasisedifferentsituationsandsubjects.Pleaserefertothefollowingexamplesfortheirmeaningsandappropriateaction.

    Special text formats and presentations• Adot(•)indicatesalist,whichisstartedbyaheading.

    – Ifanindenteddash(–)followsa“dot”,thislistisasub-sectionoftheblackdot.

    Picture symbols

    Danger!Thisinformationpointsoutadangeroussituationforapersonand/ortheproduct.Failuretocomplywiththeseinstructionscanresultininjuriestopeopleand/ordamagetomachinery.

    Caution!Thisinformationpointsoutadangeroussituationforapersonand/ortheproduct.Failuretocomplywiththeseinstructionscanresultininjuriestopeopleand/ordamagetomachinery.

    Important information before starting work

    Initial commissioning of the heater or functional test after a repair

    • Afterinstallingtheheater,thewholefuelsupplysystemmustbecarefullyvented:pleaserefertoandfollowthevehiclemanufacturer’sinstructions.

    • Duringtheheatertrialrun,allfuelconnectionsmustbecheckedforleaksandsecure,tightfit.

    • Iffaultsoccurwhiletheheaterisrunning,useadiagnosticunittodetermineandcorrectthecauseofthefault.

    1 IntroductionForeword

    TheseTroubleshootingandRepairInstructionsareapplicabletotheheaterslistedonthetitlePage,totheexclusionofallliabilityclaims.Dependingontheversionorrevisedstatusoftheheater,theremaybedifferencesbetweenitandthesetroubleshootingandrepairinstructions.Theusermustcheckthisbeforecarryingouttherepairworkand,ifnecessary,takethedifferencesintoaccount.

    Caution!Safety instructions for installation and repair!

    ImproperinstallationorrepairofEberspächerheaterscancauseafireorresultpoisonousexhaustenteringtheinsideofthevehicle.Thiscancauseseriousandevenfatalrisks.

    Theheatermayonlybeinstalledaccordingtothespecifica-tionsinthetechnicaldocumentsorrepairedusingoriginalsparepartsbyauthorisedandtrainedpersons.Installationandrepairsbyunauthorisedanduntrainedper-sons,repairsusingnon-originalsparepartsandwithoutthetechnicaldocumentsrequiredforinstallationandrepairaredangerousandthereforearenotpermitted.

    Arepairmayonlybecarriedoutinconnectionwiththere-spectiveunit-relatedtechnicaldescription,installationinstruc-tions,operatinginstructionsandmaintenanceinstructions.Thisdocumentmustbecarefullyreadthroughbefore/duringinstallationandrepairandfollowedthroughout.Particularattentionistobepaidtotheofficialregulations,thesafetyinstructionsandthegeneralinformation.

    Please note!

    Therelevantrulesofsoundengineeringpracticeandanyinformationprovidedbythevehiclemanufactureraretobeobservedduringtheinstallationandrepair.Eberspächerdoesnotacceptanyliabilityfordefectsanddamage,whichareduetoinstallationorrepairbyunauthor-isedanduntrainedpersons.Compliancewiththeofficialregulationsandthesafetyinstruc-tionsisprerequisiteforliabilityclaims.Failuretocomplywiththeofficialregulationsandsafetyinstructionsleadstoexclu-sionofanyliabilityoftheheatermanufacturer.

    Accident prevention

    Generalaccidentpreventionregulationsandthecorrespond-ingworkshopandoperatingsafetyinstructionsaretobeobserved.

  • 5

    Cutaway view

    1 Heaterimpeller 2 Controlbox 3 Combustionairfanimpeller 4 Glowplug 5 Cover 6 Heatexchanger 7 Combinationsensor(overheating/flamesensor) 8 Radioremotecontrol(mobileunit) 9 Radioremotecontrol(stationaryunit)10 Button11 Temperaturesensor(roomtemperature)12 Fusebracketwithmainfuseand“actuation”fuse13 Electricalmotor14 Fuelconnection15 Flangeseal

    16 Combustionchamber17 Outlethood18 Combustionairhose19 Meteringpump20 Pot-typestrainer,installedinthedosingpump21 Outflow22 FlexibleexhaustpipeF= FreshairW= HotairA= ExhaustB= FuelV= Combustionair

    Functionanduse2

  • 6

    Description of functions

    Switching on

    Whentheheaterisswitchedon,thecontrollampinthecon-trolunitlightsup.Theglowplugisswitchedonandthefanstartsatlowspeed.

    fthereisstilltoomuchresidualheatintheheatexchangerfromwhentheheaterwaslastused,firstlyonlythefanstartsup(coldblowing).Oncetheresidualheathasbeencleared,theheaterstarts.

    Starting Airtronic

    Afterapprox.65secondsthefuelsupplystartsandthefuel/airmixtureinthecombustionchamberignites.Oncethecombinedsensor(flamesensor)hasdetectedtheflame,theglowplugisswitchedoffafter60seconds.Theheaterisnowinstandardoperation.

    Starting Airtronic M

    Afterapprox.60secondsthefuelsupplystartsandthefuel/airmixtureinthecombustionchamberignites.Aftertheflamesensorhasdetectedtheflame,theglowplugisswitchedoffafterapprox.90sec.Theheaterisnowinstandardoperation.Afteranother120seconds,theheaterhasreachedthe“POWER”stage(maximumfuelquantity,maximumfanspeed).

    Temperature selection with the control element

    Thecontrolcanbeusedtopreselectaninteriortemperature.Theresultingtemperaturecanbewithintherangeof+10°Cto+30°Canddependsontheselectedheater,onthesizeofthespacetobeheatedandontheprevailingoutdoortem-perature.Thesettingtobeselectedatthecontrolisanempiricalvalue.

    Control in the heating mode

    Duringtheheatingmode,theroomtemperatureorthetem-peratureofthesuckedinheatingairisconstantlymeasured.Ifthetemperatureishigherthanthetemperatureselectedonthecontrolelement,theheaterstartstoregulateitsoutput.Thereare4controlstagessothattheoutflowofheatpro-ducedbytheheatercanbeadjustedfinelytotheheatingrequirements.Fanspeedandfuelquantitycorrespondtotheparticularcontrolstage.Ifthesettemperatureisstillexceededinthesmallestcontrolstage,theheatergoestothe“OFF”stagewiththefanrunningonforapprox.4minutestocooloff.Thefanthencontinuesrunningatminimumspeed(circulationmode)untiltherestartorisswitchedoff(freshairmodewithexternaltemperaturesensor).

    Ventilating mode

    TheEasyStartR+andEasyStartTcontrolunitsandthemini-controllercanbeusedtoactivatethe„Ventilate“function.The„Heat/Ventilate“switchisalsorequiredforthemodulartimerandcontroldevicewhereby,forfanmode,the„Heat/Ventilate“switchmustbepressedfirstandthentheheaterswitchedon.Theblowerrunsatmaximumspeedinfanmode.

    Switching off

    Whentheheaterisswitchedoff,thecontrollampgoesoffandthefuelsupplyisswitchedoff.Thefanrunsonforapprox.4minutestocooldown.Whilethefanisrunningon,theglowplugisswitchedonforapprox.40secondstoclean.Specialcase:Ifnofuelhasbeensuppliedoriftheheaterisinthe“OFF”stageuntilitisswitchedoff,theheaterisstoppedwithoutanyafterrunning.

    Functionanduse2

    Please note!

  • 7

    Forced shut-down for ADR operation

    Invehiclesforthetransportofdangerousgoods(e.g.tankertrucks),theheatermustbeswitchedoffbeforethetruckdrivesintoadangerarea(refinery,petrolstation,etc.).Failuretocomplyresultsintheheaterautomaticallyswitchingoffif:• thevehicleengineisswitchedoff,• anadditionalunitisstartedup(auxiliarydriveforunloading

    pump,etc.),• avehicledoorisopened(ADR99regulation,onlyinFrance).Thefanthenrunsonformax.40seconds.

    Functionanduse2

    Emergency shutdown – EMERGENCY OFFIfanemergencyshutdown–EMERGENCYOFF–isre-quiredduringoperation,executethefollowing:• Switchtheheateroffatthecontrolelementor• removethefuseor• disconnecttheheaterfromthebattery.

    Control and safety devices

    • Iftheheaterdoesnotignitewithin90secondsafterstartingthefuelpump,thestartisrepeated.Iftheheaterstilldoesnotigniteafteranother90secondsofpumpingfuel,theheaterisswitchedoff,i.e.thefuelsupplyisoffandthefanrunsonforapprox.4minutes.

    • Iftheflamegoesoffbyitselfduringoperation,theheaterisrestarted.Iftheheaterdoesnotignitewithin90secondsafterthefuelpumphasstarted,orignitesandgoesoffagainwithin15minutes,theheaterisswitchedoff,i.e.thefuelsupplyisoffandthefanrunsonforapprox.4minutes.Thisstatuscanberemediedbybrieflyswitchingoffandonagain.Donotrepeattheswitchingoff/onroutinemorethantwice.

    • Inthecaseofoverheating,thecombinedsensor(flamesensor/overheatingsensor)triggers,thefuelsupplyisinterruptedandtheheaterswitchedoff.Oncethecauseoftheoverheatinghasbeeneliminated,theheatercanbere-startedbyswitchingoffandonagain.

    • Iftheloweroruppervoltagelimitisreached,theheaterisswitchedoffafter20seconds.

    • Theheaterdoesnotstartupiftheglowplugorblowermo-torisdefectiveoriftheelectricleadtothemeteringpumpisinterrupted.

    • Ifthecombinedsensor(flamesensor/overheatingsensor)isdefectortheelectricleadinterrupted,theheaterstartsupandisthenswitchedoffagainduringthestartphase.

    • Thespeedofthefanmotorismonitoredcontinuously.Ifthefanmotordoesnotstartuporifthespeeddeviatesbymorethan10%,theheaterisswitchedoffafter30sec.

    • Whentheheaterisswitchedoff,theglowplugis switchedonfor40seconds(after-glowing)whilethe fanrunsontocleanoffanycombustionresidues.

    Please note!

    Donotrepeattheswitchingoff/onroutinemorethantwice.

  • 8

    Technichaldata3

    Providednolimitvaluesaregiven,thetechnicaldatalistedissubjecttothetolerancesusuallyapplicabletoheatersof±10%fornominalvoltage,ambienttemperature20°CandreferencealtitudeEsslingen.

    Caution!Safety instructions for technical data!Failuretocomplywiththetechnicaldatacanresultinmalfunc-tions.

    Technichal data

    Heatertype

    Heater

    Version

    Heatingmedium

    Controloftheheatflow

    Heatflow(watt)

    Heaterairflowratewithoutcounterpressure(kg/h) withhoodØ60mm

    Fuelconsumption(l/h)

    Elektr.powerconsumption(watt)

    inoperation(12and24volt)

    atstart(12and24volt)

    Ratedvoltage

    Operatingrange Lowervoltagelimit:Anundervoltageprotectioninthe

    controllerswitchesofftheheaterwhenthevoltagelimitisreached.

    Uppervoltagelimit: Anuppervoltageprotectioninthecontrollerswitchesoffthe

    heaterwhenthevoltagelimitisreached.

    Fuel

    Tolarableambienttemperature

    Heater

    Dosingpump

    Maximumairintaketemperature

    Interferencesuppression

    Weight

    Ventilationmode

    Airtronic

    AirtronicD2/AirtronicD2Camper

    D2/D2Camper

    Air

    Stage

    Power Large Medium Small Off

    2200 1800 1200 850 –

    105 90 60 40 13

    0.28 0.23 0.15 0.10 –

    34 22 12 8 5

    #100

    12or24volt

    approx.10.5voltresp.21voltUndervoltageprotectiontriggertime:20seconds

    approx.16voltresp.32voltOvervoltageprotectiontriggertime:20seconds

    DieselDINEN590(commerciallyavailable)

    inoperation nooperation

    –40°Cto+70°C –40°Cto+85°C

    –40°Cto+50°C –40°Cto+125°C

    max.+40°C

    Interferencesuppressionclass5toDINEN55025

    approx.2.7kg

    possible

    Please note!

  • 9

    Technichaldata3Technichal data

    Heatertype

    Heater

    Version

    Heatingmedium

    Controloftheheatflow

    Heatflow(watt)

    Heaterairflowratewithoutcounterpressure(kg/h) withhoodØ90mm

    Fuelconsumption(l/h)

    Elektr.powerconsumption(watt)

    inoperation(12and24volt)

    atstart(12and24volt)

    Ratedvoltage

    Operatingrange Lowervoltagelimit:Anundervoltageprotectioninthe

    controllerswitchesofftheheaterwhenthevoltagelimitisreached.

    Uppervoltagelimit: Anuppervoltageprotectioninthecontrollerswitchesoffthe

    heaterwhenthevoltagelimitisreached.

    Fuel

    Tolarableambienttemperature

    Heater

    Dosingpump

    Maximumairintaketemperature

    Interferencesuppression

    Weight

    Ventilationmode

    Airtronic M

    AirtronicB4

    B4

    Air

    Stage

    Power Large Medium Small Off

    3800 3200 2100 1300 –

    185 160 120 85 24

    0.54 0.46 0.29 0.18 –

    40 29 15 9 5

    #100

    12volt

    approx.10.5voltUndervoltageprotectiontriggertime:20seconds

    16voltOvervoltageprotectiontriggertime:20seconds

    PetrolDINEN228(commerciallyavailable)

    inoperation nooperation

    –40°Cto+50°C –40°Cto+85°C

    –40°Cto+20°C –40°Cto+125°C

    max.+40°C

    Interferencesuppressionclass5toDINEN55025

    ca.4.5kg

    possible

    Providednolimitvaluesaregiven,thetechnicaldatalistedissubjecttothetolerancesusuallyapplicabletoheatersof±10%fornominalvoltage,ambienttemperature20°CandreferencealtitudeEsslingen.

    Caution!Safety instructions for technical data!Failuretocomplywiththetechnicaldatacanresultinmalfunc-tions.

    Please note!

  • 10

    Technichaldata3Technichal data

    Heatertype

    Heater

    Version

    Heatingmedium

    Controloftheheatflow

    Heatflow(watt) D3

    D4

    D4Plus

    Heaterairflowratewithoutcounterpressure(kg/h) D3withhoodØ90mm

    D4withhoodØ90mm

    D4PluswithhoodØ75mm

    Fuelconsumption(l/h) D3

    D4

    D4Plus

    Elektr.powerconsumption(watt) D3

    inoperation(12and24volt) D4

    D4Plus

    atstart(12and24volt)

    Ratedvoltage

    Operatingrange Lowervoltagelimit:Anundervoltageprotectioninthe

    controllerswitchesofftheheaterwhenthevoltagelimitisreached.

    Uppervoltagelimit: Anuppervoltageprotectioninthecontrollerswitchesoffthe

    heaterwhenthevoltagelimitisreached.

    Fuel

    Tolarableambienttemperature

    Heater

    Dosingpump

    Maximumairintaketemperature

    Interferencesuppression

    Weight

    Ventilationmode

    Airtronic M

    AirtronicD3/AirtronicD4/AirtronicD4Plus

    D3/D4/D4Plus

    Air

    Stage

    Power Large Medium Small Off

    3000 2200 1600 900 –

    4000 3000 2000 900 –

    4000 3000 2000 900 –

    150 120 90 60 24

    185 150 110 60 24

    175 140 100 55 22

    0.38 0.28 0.2 0.11 –

    0.51 0.38 0.25 0.11 –

    0.51 0.38 0.25 0.11 –

    24 16 10 7 5

    40 24 13 7 5

    55 30 16 7 5

    #100

    12or24volt

    approx.10.5voltresp.21voltUndervoltageprotectiontriggertime:20seconds

    approx.16voltresp.32voltOvervoltageprotectiontriggertime:20seconds

    DieselDINEN590(commerciallyavailable)

    inoperation nooperation

    –40°Cto+70°C –40°Cto+85°C

    –40°Cto+50°C –40°Cto+125°C

    max.+40°C

    Interferencesuppressionclass5toDINEN55025

    approx.4.5kg

    possible

    Providednolimitvaluesaregiven,thetechnicaldatalistedissubjecttothetolerancesusuallyapplicabletoheatersof±10%fornominalvoltage,ambienttemperature20°CandreferencealtitudeEsslingen.

    Caution!Safety instructions for technical data!Failuretocomplywiththetechnicaldatacanresultinmalfunc-tions.

    Please note!

  • 11

    Technichaldata3Technichal data

    Heatertype

    Heater

    Version

    Heatingmedium

    Controloftheheatflow

    Heatflow(watt) D4S

    D4Camper/D4CamperPlus

    Heaterairflowratewithoutcounterpressure(kg/h) D4S

    D4Camper/D4CamperPlus

    Fuelconsumption(l/h)) D4S

    D4Camper/D4CamperPlus

    Elektr.powerconsumption(watt) D4S

    inoperation(12and24v) D4Camper/D4CamperPlus

    atstart(12and24v)

    Ratedvoltage

    Operatingrange Lowervoltagelimit:Anundervoltageprotectioninthe

    controllerswitchesofftheheaterwhenthevoltagelimitisreached.

    Uppervoltagelimit: Anuppervoltageprotectioninthecontrollerswitchesoffthe

    heaterwhenthevoltagelimitisreached.

    Fuel

    Tolarableambienttemperature

    Heater

    Dosingpump

    Maximumairintaketemperature

    Interferencesuppression

    Weight

    Ventilationmode

    Airtronic M

    AirtronicD4S/Airtronic D4Camper/AirtronicD4CamperPlus

    D4S/D4Camper/D4CamperPlus

    Air

    Stage

    Power Large Medium Small Off

    3500 3000 2000 1000 –

    4000/3500 3000 2000 900 –

    160 140 100 60 22

    185/160 150/140 110/100 60/55 24/22

    0.44 0.38 0.25 0.13 –

    0.51/0.44 0.38 0.25 0.11 –

    40 30 16 8 5

    40 24/30 13/16 7/8 5

    #100

    12or24volt

    approx.10.5voltresp.21voltUndervoltageprotectiontriggertime:20seconds

    approx.16voltresp.32voltOvervoltageprotectiontriggertime:20seconds

    DieselDINEN590(commerciallyavailable)

    inoperation nooperation

    –40°Cto+70°C –40°Cto+85°C

    –40°Cto+50°C –40°Cto+125°C

    max.+40°C

    Interferencesuppressionclass5toDINEN55025

    approx.4.5kg

    possible

    Providednolimitvaluesaregiven,thetechnicaldatalistedissubjecttothetolerancesusuallyapplicabletoheatersof±10%fornominalvoltage,ambienttemperature20°CandreferencealtitudeEsslingen.

    Caution!Safety instructions for technical data!Failuretocomplywiththetechnicaldatacanresultinmalfunc-tions.

    Please note!

  • 12

    Check values

    Test speed for the blower

    Airtronic D2 / D2 Camper(12volt/24volt)• 12volt 5000rpm±25% atU=10,0volt• 24volt 5000rpm±25% atU=18,0volt

    AirtronicB4 (12volt)AirtronicD3 / D3 Camper(12volt)AirtronicD4(12volt/24volt)AirtronicD4 Camper(12volt)• 12volt 4400rpm±25% atU=10,0volt• 24volt 4400rpm±25% atU=18,5volt

    AirtronicD4S/Airtronic D4 Plus (12volt/24volt)AirtronicD4 Camper Plus (12volt)• 12volt 4400rpm±25% atU=10,5volt• 24volt 4400rpm±25% atU=19,0volt

    Resistance values at 20 °C

    12 volt 24 volt

    Glowplug 0.42 –0.70 1.2 –2.0Dosingpump 9.5±0.50 36.0±1.8

    Control unit resistance values

    Switch position, left limit stop

    Switch position, right limit stop

    Controldevice12volt/24volt

    min.1720max.1760

    min.2096max.2216

    Modulartimerandmini-controller12volt/24volt

    min.1730max.1780

    min.2120max.2240

    Switching value Overheatingsensor 140°C–170°C measuredinthe“High”controlstage andatadistanceof300mmdownstream fromthehotairoutletExhaust emission specificationCO2 in exhaustincontrolstage“high” 7,5–12,5Vol.%SmokespotnumberaccordingtoBacharach <4

    Temperature (°C)

    Res

    ista

    nce

    (ohm

    )

    2200

    2000

    1800

    1600

    1400

    1200

    1000±40 ±20 0 20 40±10±30 10 30

    2400

    50

    Technicaldata3

    Check “external” temperature sensor(OrderNo.:251774890300)The“external”temperaturesensortestmustbecarriedoutusingadigitalmultimeter.Iftheresistancevalueisnotthesameasthecurveinthediagramorthetableofvalues,re-placethetemperaturesensor.

    Table of values – “external” temperature sensor

    Temperature°C Resistance

    min. max.0 1600 16605 1670 1730

    10 1745 180015 1820 187020 1895 195025 1970 203030 2050 211035 2130 219040 2210 228045 2295 2370

  • 13

    Troubleshooting4What to check first in case of faults

    • Check– Fuelinthetank?– Fuelpipesleaking?(visualcheck)– Summerdieselinthefuelpipe?– Combustionairsystemorexhaustsystemdamagedor

    blocked?– Hotairsystemblocked?– Airpressuresensorinstalled?Ifyes,referto„Whattodo

    if…?“chapterofthe„AltitudeKit“installationinstructions.– Newgenerationcontrolboxinstalled? Features: >Cableloomofcontrolboxwoundwithcabletie >Temperaturesensormountedonthesideofthecontrol

    box(visiblewhencoverremoved)

    • Electrical components– Cables,connectionsdamaged?– Contactscorroded?– Fusesdefective?– Incorrectwiring?(shortcircuits,interrupted/broken)

    • Measure battery voltage– Batteryvoltage<10.5volt,theundervoltageprotectionof

    the12voltheaterhastriggered.– Batteryvoltage<21volt,theun

    • Measure voltage supply (Cl 30) Disconnectthe16-pinconnectorS1/B1andmeasurethe

    voltageappliedatconnectorB1betweenchamber1(cable2.52rt)andchamber10(cable2.52br).

    Ifitdiffersfromthebatteryvoltage,checkthefuses,thesupplycables,thenegativeconnectionandthepositivesupportpointonthebatteryforvoltagedrop(corrosion/interruption).

    • Check switch-on signal Disconnectthe16-pinconnectorS1/B1andthenswitch

    ontheheateratthecontrolunit. CheckwhethervoltageisappliedintheconnectorB1

    betweenchamber4(cable0.52ge)andchamber10(cable2.52br).

    Ifnovoltageismeasured,thencheckthesupplycable(ca-ble0.52ge),the5Afuse(item2.7.1inthecircuitdiagram)andthecontrolunit.

    • Check control unit

    Control device, mini-timer, mini-controller and modular timer

    Disconnecttheconnectoratthecontrolunit;installajumperbetweenthered0.5²rtcableandtheyellow0.5²gecable.

    IfavoltageismeasuredinconnectorB1betweencham-ber4(cable0.5²ge)andchamber10(cable2.5²br),thenreplacethecontrolunit.

    EasyStart R+ / EasyStart R / EasyStart T Disconnecttheconnectoratthecontrolunit;installajumper

    betweentheyellow0.5²gecableandthered0.5²rtcable. IfavoltageismeasuredinconnectorB1betweencham-

    ber8(cable0.5²ge)andchamber10(cable2.5²br),thenreplacethecontrolunit.

  • 14

    Troubleshooting4Overview of the test equipment and control units suitable for diagnosis

    Theelectroniccontrolboxcanstoreupto5faults,whichcanbereadoutanddisplayed.Thefollowingtestequipmentand/orcontrolunitscanbeusedtoquerythefaultmemoryinthecontrolboxandifnecessarytodeletethelockingofthecontrolbox:

    Test equipment Order No.:

    • Testingdevice forthecontroldevice 221509890000

    • Diagnosticunit 221529890000 additionallyrequired: Adaptercable 221000318600

    • EDiTHdiagnostictool – Basicadapterwithsoftware 221542890000 additionallyrequired: Airtronicextension 221537890000

    – ISO-adapter 221541890000 additionallyrequired: Adaptercable 221000318600

    – „Airpressuresensor“adaptercable221000333100 Onlyforheaterswithconnectedairpressuresensorfor

    readingoutthe„airpressuresensor“faultmemory.

    Ifadiagnosticscableisconnected,thefollowingcontrolunitscanalsobeused:

    Control units Order No.:

    • Moduletimer 221000303400

    • TP5radioremotecontrol 221000320100

    • EasyStartT 221000328800

    • EasyStartR+ 221000328000

    Please note!

    Ifthefaultmemorycannotbereadout,checkthediagnosticscableforcorrectlayingandpossibledamage.

    Important notes on diagnosis of heaters with mini-controller control unit

    Caution!WhencheckingtheheaterwiththediagnosticsunitortheEDiTHdiagnosticstooltheordergiveninthefollowingnotesmustalwaysbefollowedasotherwisetheheaterdetectsError62(controlunit–interruption)andswitchestoemergencyoperation.

    Mini-controller in stand-alone operation

    • Connectadaptercable221000318600asdescribedintheoperatinginstruction.

    • Selectoperatingmode(Heat/Ventilate)atthemini-control-ler

    • PerformdiagnosisusingthediagnosticsunitortheEDiTHdiagnosticstool.

    • Switchoffthemini-controllerafterfinishingthediagnosis• Removetheadaptercable

    Mini-controller in combination with mini-timer

    • Connectadaptercable221000318600asdescribedintheoperatinginstruction.

    • Pressthembuttonofthemini-timer• Selectoperatingmode(seemini-timeroperatinginstruc-

    tions)• PerformdiagnosisusingthediagnosticsunitortheEDiTH

    diagnosticstool.• Switchoffthemini-timerafterfinishingthediagnosis• Removetheadaptercable

    Mini-controller in combination with TP5

    • Connectadaptercable221000318600asdescribedintheoperatinginstruction.

    • Pressthe buttonoftheTP5radioremotecontrol• Selectoperatingmode(seeTP5radioremotecontroloper-

    atinginstruction)• Performdiagnosis.• SwitchoffTP5radioremotecontrolafterfinishingthediag-

    nosis• Removetheadaptercable

    Please note!

    IftheoperatingmodeistobechangedduringthetesttheheatermustbeswitchedofffirstusingthediagnosticsunitortheEDiTHdiagnosticstool,otherwisetheheaterdetectsError62(controlunit–interruption)andswitchestoemergencyoperation.

    Test mini controller

    Themini-controllermustbeconnectedtotheheaterfortest-ing.ThesetpointvaluecanbedisplayedusingtheEDiTHdiagnosticstool.Iftherotaryknobisattheleftlimitstopthesetpointvalueis8°C,attherightlimitstopitis34°C.

    Please note!

    Theresistanceofthesetpointvaluepotentiometercannotbemeasureddirectly.Themeasuredvaluesarenotmeaningful.

  • 15

    Troubleshooting4Testing device for the control device(OrderNo.:221509890000)

    Prepare for testConnectthecorrectoperatingvoltage(12or24volt)tothete-stingdevice,withplusattheredconnectorsocketandminusattheblueconnectorsocket.

    • Disconnectsocketfromthecontrolunit.• Connectcableloomfromtestingdevicewiththecontrol

    unit.• Settherotaryknobofthecontrolunitto“Heat”,thecorre-

    spondingredLEDinthetestingdevicemustlightup.• Setcontrolunitto“0”,thenpressthe“LED–red”button,

    theredcontrollampinthecontrolunitmustlightup.• Setcontrolunitto“Heat”,thenpressthe“LED–green”

    button,correspondingredcontrollampinthetestingdeviceandthegreencontrollampinthecontrolunitmustlightup.

    Caution!Safety instructions for checking the control unit!Ensureyouusethecorrectoperatingvoltage,otherwisetheconnectedcomponentscanbeseverelydamaged.

    Check the setpoint potentiometer of the control unitSetthe“Temperaturesensor/Potentiometer”switchinthetestingdevicetothe“Potentiometer”settingandslowlyturntherotaryknobofthecontrolunit.ThegreenLED–temperaturesensor/potentiometermustlightupcontinuously.Incaseofafault,replacethecontrolunit.

    1 Testingdevice2 Controldevice

    Diagnostic unit(OrderNo.:221529890000)

    Anadditionaladaptercableisrequiredtoconnectthediag-nosticunit(OrderNo.:221000318600).

    Thecurrentfaultisdisplayedas“AF”anda2-digitnumberandisalwayswritteninthememorypositionF1.PrecedingfaultsaremovedtothememorylocationsF2–F5,ifnecessarythecontentsofmemorypositionF5isoverwrit-ten.

    • Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.

    • Inheaterswithconnectedairpressuresensorthediagnos-ticsunitcanbeusedtoreadoutthefaultmemoryoftheheateronly.

    Thefaultmemoryofthe„airpressuresensor“canbereadoutusingtheEDiTHdiagnosticstoolonly.

    • Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.

    l–Deletefaultmemoryl–Deletefaultmemoryd–Switchheateron/off,requestdiagnosise–Reverse,F5–F1f–Forward,F1–F5,currentfault(AF)

    Connectdiagnosticsunit,seepage16.

    Please note!

  • 16

    Connect diagnostic unit• Disconnectthe8-pinconnectoroftheheater’scablehar-

    nessandconnecttheadaptercable.• Connectthediagnosticunittotheadaptercable. Displayisasfollows:

    Query fault memory• UsetheDkeytoswitchontheheater. Displayisasfollows:

    • After8secthefollowingisdisplayed: Displayisasfollows:

    Heaterhasnomalfunction or

    e.g.currenterror/faultcode64

    or

    Faultdiagnosisnotpossible

    Possiblecauses: – Adaptercableisnotproperlyconnected. – Controlboxisdefectiveorisnotcapableofdiagnosing

    (notauniversalcontrolbox).

    Display of the fault memory F1 – F5 or F5 – F1• Presstheeorfbutton,orpressseveraltimes,todisplay

    thefaultmemory. Displayisasfollows:

    e.g.faultmemory2/faultcode10

    Onlythefaultmemorypositionswithanerrorassignedtothemaredisplayed.

    Delete fault memory• PressbothLbuttonssimultaneouslyuntilthefollowingap-

    pearsinthedisplay: Displayisasfollows:

    • Ifthefaultmemoryhasbeendeletedthemostrecentcur-rentfaultisdisplayed.Thecurrentfaultisnotresetto00untiltheheaterisrestarted–providedthereisnonew,morerecentfault.

    Displayisasfollows:

    Heaterhasnomalfunction

    Cancel the control box lock• Deletethefaultmemoryasdescribedandswitchoffthe

    heaterusingthedkey.• Thecontrolboxlockiscancelledandthediagnosisclosed. Displayisasfollows:

    Troubleshooting4

    1 Heater2 Adaptercable3 Diagnosticunit

    1

    2

    3

    Please note!

  • 17

    Troubleshooting4EDiTH diagnostic tool with ISO adapter(OrderNo.:221541890000)

    AnadditionaladaptercableisrequiredtoconnecttheISOadapter(OrderNo.:221000318600).

    • Itisveryimportanttoalwaysinstallinthegivenorder.• Notonlythedefectivecomponent,butalsoadefectivecur-

    rentcircuitresultsinafaultbeingdisplayed.• Faultcode,faultdescription,cause/remedialactionare

    describedonPages23–27.• TheEDiTHdiagnosticstoolscopeofsupplydoesnot

    includethesoftware;thismustbedownloadedfromtheServicePortal.

    Connect ISO adapter

    • Disconnecttheheater’scableharness.• Connecttheadaptercabletothecableharness–asshown

    inthesketch.• ConnecttheadaptercabletotheISOadapter.• ConnecttheSUB-DconnectioncablewiththePCandthe ISOadapter.

    Installing the software on your PC• Doubleclickthe“setup.exe”filetostarttheinstallationand

    followingtheSETUPprograminstructions.

    Query / delete fault memory F1 – F5 or cancel the control box lock• StartthesoftwareonyourPC: – onthedesktop—>doubleclickthe“EDiTH”icon – Selectheatertype – Pressthe“GO”button.

    • Deletefaultmemoryorcancelthecontrolboxlock: – pressthe“Deletefaultmemory”button —>thestoredfaultsF1–F5aredeletedandthecontrol

    boxisunlocked.

    Quit diagnosis• Pressthe“STOP”button—>faultmemoryqueryisended.

    1 Heater2 Adaptercable3 ISOadapter

    4 SUB-Dconnectioncable5 USBtoSerialRS-232adapter

    � �

    Please note!

  • 18

    Troubleshooting4Air pressure sensor diagnosis using EDiTH diagnostics tool and ISO adapter(OrderNo.221524890000)

    AnadditionaladaptercableisrequiredtoconnecttheISOadapter(OrderNo.:221000333100).

    Theairpressuresensorconnectedtotheheatercanbediag-nosed.Iffaultsoccurduringthealtitudeadjustmenttheyarestoredintheairpressuresensor.Ifnecessary,faultscanbereadoutusingtheISOadapterinconjunctionwiththeEDiTHdiagnosticstool–fromVersionS3V7-F–andtheadditionallynecessaryadaptercable.

    Please note!

    • Itisveryimportanttoalwaysinstallinthegivenorder.• Notonlythedefectivecomponent,butalsoadefectivecur-

    rentcircuitresultsinafaultbeingdisplayed.• Faultcode,faultdescription,cause/remedialactionare

    describedonpages27.• TheEDiTHdiagnosticstoolscopeofsupplydoesnot

    includethesoftware;thismustbedownloadedfromtheServicePortal.

    Perform diagnosis of the air pressure sensor

    Disconnecttheconnectorbetweentheairpressuresensor/heater,controlunit,connecttheISOadapterwiththeadaptercable(seesketch).Startthediagnosisoftheairpressuresensor.

    • Double-clickthe>>EDiTH

  • 19

    Caution! Magnetic field!Duringthetestoperationamagneticfielddevelopsattheadapter.Therefore,donotplaceanyobjectssuchasdatamedia,creditcards,etc.ontheadapterorinitsimmediatevicinity.

    Troubleshooting4

    (A) Basicadapter(B) SUB-Dconnectioncable(C) Mainsconnection(D) Mainsswitch(E) USBtoSerialRS-232adapter(F) Adapter(G) Controlbox

    Cable colourssw = blackgn = greenbl = blue

    EDiTH diagnostic tool with basic adapterEDiTHbasicadapter(OrderNo.:221542890000)

    Anadditionalextensionisrequiredtocheckthecontrolbox(OrderNo.:221537890000).

    • Itisimportanttoalwaysfollowthepreciseconnectionorderasgivenbelow!

    • TheHallsensorintegratedinthecontrolboxcanonlybeproperlytestedinthecontrolboxiscorrectlyplacedontheextension.

    • Onlypushorpullontheconnectors,notonthecables!• OnlyusethenetworkcableandRS232cablewithsnap

    ferritesincludedinthescopeofsupply.Useoriginalacces-sorieswithsnapferritesonlytoconnectthetestequipment.

    • Notonlythedefectivecomponent,butalsoadefectivecurrentcircuitresultsinafaultbeingdisplayed.

    • Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.

    Connect basic adapter• Startcomputerandwaituntilthesystemhassuccessfully

    booted.• StartPCsoftware.• Inserttheunitconnectorofthemainscableinthebasic

    adapter(A)andconnectthemainsconnection(C)tothemains.

    • ConnecttheSUB-Dconnectioncable(B)withthePCandbasicadapter(A).

    Connect extension and test control box• Connecttheextensiontothebasicadapter(A).• Connectthecontrolbox(E)totheextensionandtheadap-

    ter(F).• Switchonthebasicadapter(A)atthemainsswitch(D).• Selectthecontrolboxversionandoperatingvoltage

    (12V/24V)inthePCsoftware.• StartthecontrolboxtestwiththePCsoftware.Amorede-

    taileddescriptionofhowtooperatethebasicadapters(A)isgivenintheEDiTHonlinehelp.

    Please note!

  • 20

    Troubleshooting4Module timer(OrderNo.:221000303400)

    Thecurrentfaultisdisplayedas“AF”andisalwayswritteninmemorypositionF1.PrecedingfaultsaremovedtothememorylocationsF2–F5,ifnecessarythecontentsofmemorypositionF5isoverwrit-ten.

    • Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.

    • Inheaterswithconnectedairpressuresensorthemodulartimercannotbeusedtoperformdiagnoses.Thediagnos-ticsunitortheEDiTHdiagnosticstoolmustbeusedtoperformthediagnosis.

    Thefaultmemoryofthe„airpressuresensor“canbereadoutusingtheEDiTHdiagnosticstoolonly.

    • Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.

    Query fault memory F1 – F5 Condition:Theheaterisswitchedoff.

    • Pressckey–>theheaterisswitchedon.

    • Pressakeyandkeeppressed, thenpresspkeywithin2seconds. Displayisasfollows: AF=currentfault 3digitnumber=faultcode cflashes.

    • Pressfkeyonceorseveraltimes,faultmemorypositionsF1–F5aredisplayed.

    Cancel the control box lock and simultaneously delete the fault memoryCondition:Anelectricalconnectionexistsfromterminal15(ignition)tothemoduletimer,12-pinconnector,chamber10.

    • Pressckey Displayisasfollows: thecurrentfaultF15orF50.

    • Pressbuttona,keepitdepressedandthenpressbuttonpwithin2seconds.

    Themoduletimerisnowinthe“Queryfaultmemory”pro-gram.

    • Switchoffignition(terminal15).

    • Simultaneouslypressbuttonaandbuttonp,inaddition,switchontheignition(terminal15)andwaituntilthefollow-ingappearsinthedisplay.

    Afterignition“ON”thefollowingappearsinthedisplay:

    Displayflashes, Heatersymboldoesnotflash

    • Switchtheheateroffandon–>thecontrolboxisunlocked,theheaterrestarts.

    Afterswitchingtheheateroffandonandrenewedqueryofthefaultmemory,thefollowingappearsinthedisplay:

    Displayflashes, Heatersymboldoesnotflash

    a–Timep–Presetc–Heate–Reversef–Forward

    Please note!

  • 21

    Troubleshooting4TP5 radio remote control(OrderNo:221000320100)

    Iffaultsoccurwhiletheheaterisrunning,theyaredisplayedwith“Err”afterthemobileunitisactivated.

    Afterthediagnosticscable(bl/ws)hasbeenconnectedandthefirstlogshavearrivedatthestationaryunit,thediagnosecanbecarriedoutusingthemobileunitoftheTP5radioremotecontrol.Thecurrentfault“F0”isdisplayed.Thestoredfaults“F1”to“F5”canbequeried.

    • Inordertocarryoutthediagnosis,thediagnosticscable(bl/ws)mustbeconnectedtothestationaryunitandtheheatercableharness.Tothisend,pleaserefertoandfollowthecircuitdiagramfortheTP5radioremotecontrolandtheheater.

    • Ifthediagnosticscable(bl/ws)isnotconnected,the“Diag-nosis”menuisblocked.

    • Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.

    • InheaterswithconnectedairpressuresensortheTP5radioremotecontrolcannotbeusedtoperformdiagnoses.ThediagnosticsunitortheEDiTHdiagnosticstoolmustbeusedtoperformthediagnosis.

    Thefaultmemoryofthe„airpressuresensor“canbereadoutusingtheEDiTHdiagnosticstoolonly.

    • Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.

    Buttontoactivate/deactivatethemobileunit

    Buttonforforwardtimesetting

    Buttonforbackwardtimesetting

    Buttonforactivatingthepossiblesettings

    Buttonforswitchingheat/ventilateON/OFF; Activate/deactivatepreselectedtime

    Enquire / delete fault memoryUsethe keytoactivatethemobileunit.Switchontheheaterwiththe key.Pressthe keytwicetoopentheTimesettingmenu–thetimeflashesinthedisplay.

    Pressthe keyforapprox2sec–untilthefollowingap-pearsinthedisplay:

    Press key.Press key.Press keytwice.Press key.

    Malfunctioninheater: Heaterhasnomalfunction:

    Usethe and buttonstocallupthefaultmemoryposi-tions1to5.

    Delete fault memory / Cancel the control box lockUsethe keytodeletethefaultmemory.

    Toconfirm,pressthe keyforapprox2secuntil lightsupinthedisplay–faultmemoryisdeleted.

    Please note!

  • 22

    The following actions are possible• Callupfaultmemory. CallupthefaultmemorypositionsF1–F5with or .

    • Callupfaultmemoryagain. Brieflypress and simultaneously.

    • Deletefaultmemory (displaydEL) Press .

    Press again.

    The diagnosis is completed.

    Switch off heater.

    Enquire / delete fault memoryActivatemobilepart/timer(seeEasyStartR+/EasyStartToperatinginstructions)

    Confirmsymbol with .

    Heater is switched on.

    Confirmoperatingtimewith .

    Brieflypress and simultaneously.

    Troubleshooting4EasyStart R+ radio remote control(Order-No.:221000328000)

    EasyStart T timer(Order-No.:221000328800)

    Iffaultsoccurwhiletheheaterisrunning,theyaredisplayedwith“Err”afterthemobileunitortimerisactivated.

    Thecurrentfaultisdisplayed.Thestoredfaults“F1”to“F5”canbequeried.

    • Inordertocarryoutthediagnosis,thediagnosticscable(bl/geatheaterconnector,bl/wsatcableharnessconnector)mustbeconnectedtothestationaryunitandtheheatercableharness.Tothisend,pleaserefertoandfollowthecircuitdiagramfortheradioremotecontrolandtheheater.

    • Ifthediagnosticscableisnotconnected,the“Diagnosis”menuisblocked.

    • Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.

    • Theheaterdiagnosiscanalsobeperformediftheairpres-suresensorisconnected.

    Thefaultmemoryofthe„airpressuresensor“canbereadoutusingtheEDiTHdiagnosticstoolonly.

    • Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.

    Backcontrolkey

    Nextcontrolkey

    ON/OFFactivationkeymobileunit/timer

    OKkey(symbolselection/confirminput)

    Please note!

  • 23

    Troubleshooting4Fault codeDisplay

    Fault description Comments• Remedial action

    000 Nofaults ——

    004 Warning:Shortcircuitincontrolbox,freshairoutput

    • DisconnectconnectorS1/B1attheheaterandattheconnectorB1,PIN16checkthecableuptothefreshairfanrelayforshortcircuittonegative,ifok—>replacecontrolbox.

    005 Warning:Shortcircuitincontrolbox,caralarmoutput

    • DisconnectconnectorS1/B1attheheaterandattheconnectorB1,PIN15checkthecableuptotherelayisolatingswitchorburglaralarmsysteminputforshortcircuittonegative,ifok—>replacecontrolbox.

    006 Warning:Inexplicableatmosphericaltitudeinformation(Displayonlyifheaterslabelled“H-Kit”onthenameplate.)

    Controlboxhasnotreceivedanyexplicablealtitudeinformation.• ReadoutfaultmemoryintheairpressuresensorusingtheEDiTHdiagnos-

    ticstoolandcorrectfault.

    009 Cut-offADR ADRshutdownduetosignalchangefrom(+)to(–)atconnectorS1,PIN13(D+)orplussignalatconnectorS1,PIN14(HA+).

    010 Overvoltage–cut-off Overvoltageappliedtocontrolboxforatleast20secondswithoutinterruption–heaternotworking.• DisconnectconnectorS1/B1attheheater,startthevehicle’sengine,

    measurethevoltageatconnectorB1betweenPIN1(cable2.52rt)andPIN10(cable2.52br).

    Airtronic12volt–voltage>16volt—>checkgeneratorregulator Airtronic24volt–voltage>32volt—>checkgeneratorregulator

    011 Undervoltage–cut-off Undervoltageappliedtocontrolboxforatleast20secondswithoutinterrup-tion–heaternotworking.• DisconnectconnectorS1/B1attheheater,thevehicle’sengineisswitched

    off,measurethevoltageatconnectorB1betweenPIN1(cable2.52rt)andPIN10(cable2.52br).

    Themeasuredvalueandthevoltageatthebatteryshouldbethesame. Incaseofavoltagedrop,checkthefuses,thesupplycables,thenegative

    connectionsandthepositivesupportpointonthebatteryforcorrosionandcorrectcontact.

    012 Overheatingattheoverheatingsensor Temperatureoftheoverheatingsensortoohigh.• Checkhotairpipesforblockage—>removeblockage.• Sumofthecomponentratingsofair-conductingpartsistoolarge—>

    Checkairsystem,ifnecessaryre-lay–forcomponentratings,pleaserefertoadditionalpartscatalogue.

    • Checkoverheatingsensor,fordiagramandtableofvaluespleaserefertoPage32,ifok—>measurefuelquantity,seePage36.

    013 Overheatingattheflamesensor Flamesensorsignalstemperatureatheatexchangeristoohigh.• Checkhotairpipesforblockage—>removeblockage.• Sumofthecomponentratingsofair-conductingpartsistoolarge—>

    Checkairsystem,ifnecessaryre-lay–forcomponentratings,pleaserefertoadditionalpartscatalogue.

    • Checkflamesensor,ifok—>checkoverheatingsensor,ifoverheatingsensordefective—>replacecombinationsensor,ifoverheatingsensorok—>measurefuelquantity,seePage36,fordiagramandtableofvaluesforflamesensorandoverheatingsensorpleaserefertoPage32.

    014 Temperaturedifferencebetweenflamesensorandoverheatingsensortoolarge

    Temperaturedifferencebetweenflamesensorandoverheatingsensortoolarge• Checkhotairpipesforblockage—>removeblockage.• Sumofthecomponentratingsofair-conductingpartsistoolarge—>

    Checkairsystem,ifnecessaryre-lay–forcomponentratings,pleaserefertoadditionalpartscatalogue.

    • Checkflamesensor,ifok—>checkoverheatingsensor,ifoverheatingsen-sordefective—>replacecombinationsensor,ifoverheatingsensorok—>measurefuelquantity,seePage36,iffuelquantityok—>replacecontrolbox.Fordiagramandtableofvaluesforflamesensorandoverheatingsen-sor,seePage32.

  • 24

    Troubleshooting4Fault codeDisplay

    Fault description Comments• Remedial action

    015 Operatinglock-out Thefaultcode015isdisplayed,iftheheaterwasswitchedbackonafterthefaultcodedisplay017.

    Thehardwarethresholdvaluefortheoverheatingsensorhasbeenexceeded—>thecontrolboxislocked.

    • Replacecontrolbox.

    017 Overheating Thehardwarethresholdvaluefortheoverheatingsensorhasbeenexceeded,becausethecontrolboxfailedtorecognisethefaultcode012or013–>thecontrolboxislocked.Iftheheaterisswitchedonagain,thefaultcode015isdisplayed.• Replacecontrolbox.

    018 Startingenergyoftheglowplugistoolow(Displayonlyifheaterslabelled“H-Kit”onthenameplate.)

    • Checkglowplug(seefaultcode020and021),ifok• Checkglowplugcableharnessforcorrectlayinganddamage,ifok—>

    checkcableharnessforcontinuity,ifok—>replacecontrolbox.

    019 Ignitionenergytoolow • Checkglowplug(seefaultcode020and021),ifok• Checkglowplugcableharnessforcorrectlayinganddamage,ifok—>

    checkcableharnessforcontinuity,ifok—>replacecontrolbox.

    020

    021

    Glowplug–interruption

    Glowplug–shortcircuit,overloadorshortcircuitafternegative

    • Checkglowplugforfunctionandcontinuityatambienttemperature20°C. 12voltheater–0.42upto±0.7 24voltheater–1.2upto±2.0

    • Ifthevaluesareok—>checkglowplugleadharnessfordamageandcon-tinuity,ifok—>replacecontrolbox.

    022 * Glowplug,output(+)–shortcircuitafterUB(batteryvoltage)

    • Checkglowplugleadharnessforcorrectlayinganddamage,ifok—>checkleadharnessforcontinuity,ifok—>replacecontrolbox.

    025 * Diagnosticscablebl/ws–shortcircuit–afterUB(batteryvoltage)

    Faultcodedisplayisnotpossible.Thisfaultcodecannotbereadoutfromthefaultmemoryuntilthefaulthasbeencorrected.• Checkdiagnosticscableforcorrectlayingandpossibledamage.

    031 Blower–interruption • Checkthattheleadharnessoftheblowermotorhasbeencorrectlylaidandcheckfordamage,ifok—>removeleadharnessatcontrolboxandcheckforcontinuity,ifok—>replacecontrolbox.

    032 Blowermotor–shortcircuitafternegative

    Please note!

    Ensurecompliancewiththetestvolt-age(seepage12).Thecomponentisdestroyedifthevoltagevalueisexceeded.Ensure the power pack has ad-equate short-circuit resistance – min 20 A.

    • Carryoutfunctionaltestontheblowermotor,todothisremovethecon-nectorfromthecontrolbox.Applyatestvoltage(seepage12)totheblow-ermotorandmeasurethecurrentintensityafter40sec.

    Currentintensity<6.5A–blowermotorok–>replacecontrolbox. Currentintensity>6.5A—>replaceblower.• Checkwiringforshortcircuit.

    033 Blowermotorwon’trotateorshortcircuitafternegative

    Please note!

    Ensurecompliancewiththetestvolt-age(seepage12).Thecomponentisdestroyedifthevoltagevalueisexceeded.Ensure the power pack has ad-equate short-circuit resistance – min 20 A.

    Speeddeviation>10%fromsetpointvalueforlongerthan30seconds.Useanon-contactr.p.m.countertomeasurethespeedofthecombustionair

    fan(seepage12fortestspeedandtestvoltage).• Speedtoolow: Blowerblocks–checkblowerforfreerunning,ifnecessaryremoveforeign

    body,ifok—>checkblower(seefaultcode032).• Speedtoohigh: – Magnetmissingfromblowerimpeller—>replaceblower. – Speedsensorincontrolboxisdefective—>replacecontrolbox.• Checkwiringforshortcircuit.

    * Thisfaultcodeorohmicvalueisvalidforanewgenerationcontrolboxonly.Thisdiffersfromthecontrolboxtodatebyitscableloomwrappedincabletapeandbyatemperaturesensormountedontheside,whichbecomesvisiblewhenthecoverisremoved.

  • 25

    Troubleshooting4Fault codeDisplay

    Fault description Comments• Remedial action

    034 * Blowermotor,outlet(+)shortcircuitafterUB(batteryvoltage)

    • Checkthattheleadharnessoftheblowermotorhasbeencorrectlylaidandcheckfordamage,ifok—>removeleadharnessatcontrolboxandcheckforcontinuity,ifok—>replacecontrolbox.

    047 Meteringpump–shortcircuitoroverload

    • Removeconnectorfromthemeteringpump,ifthefaultcode048(inter-ruption)isdisplayedthemeteringpumpisdefective—>replacemeteringpump.

    • Ifthefaultcode047continuestobedisplayed,disconnectconnectorS1/B1attheheater,andattheconnectorB1,PIN5checkthecable12gn/rtuptothemeteringpumpforshortcircuittonegative(PIN10),ifok–>replacecontrolbox.

    048 Meteringpump–interruption • Disconnectconnectorfrommeteringpumpandmeasuretheresistancevalueofthemeteringpump(seePage12forvalues),ifresistancevalueok,re-connectthecableloomtothemeteringpump.

    • DisconnectconnectorS1/B1attheheaterandmeasuretheresistancevalue(seePage12)betweenPIN5andPIN10,ifok—>replacecontrolbox.

    049 * Meteringpumpoutlet(+)Shortcircuit–afterUB(batteryvoltage)

    • Checkthattheleadharnessofthemeteringpumphasbeencorrectlylaidandcheckfordamage,ifok—>removeleadharnessandcheckforconti-nuity,ifok—>replacecontrolbox.

    050 Toomanyfailedstartattempts(opera-tinglock-out)

    Thecontrolboxlocksaftertoomanyfailedstartattempts(max.255startat-tempts).• Unlockthecontrolboxbydeletingthefaultmemorywiththetimer,thedi-

    agnosticunit,EDiTHdiagnostictool,theTP5radioremotecontrol/EasyS-tartR+andtheEasyStartTtimer.

    051 Flamedetectedwhenswitchingon If,afterbeingswitchedon,theresistancevalueoftheflamesensoris1274(>70°C)theheater’sfanrunsforapprox15mintocooldown,iftheresist-ancedoesnotfallbelowtheaforementionedvaluewithin15mintheheaterisswitchedoff.

    • Checkflamesensor,seePage32fordiagramandtableofvalues,ifok—>replacecontrolbox.

    052 Safetytimeexceeded Noflamedetectedwithinthestartphase.• Checkexhaustandcombustionairsystem.• Checkfuelsupply/measurefuelquantity,seePage36.• Checksparkplug(seefaultcode020and021)• Checkflamesensor,diagramandtableofvalues,seePage32,

    ifok—>replacecontrolbox.

    053

    054

    055

    056

    Flamecutoutinthe

    “POWER”controlstage

    “HIGH”controlstage

    “MEDIUM”controlstage

    “LOW”controlstage

    Theheaterhasignited(flamedetected)andsignalsflamecutoutduringapowerstage.

    • Checkexhaustandcombustionairsystem.• Checkfuelsupply/measurefuelquantity,seePage36.• Checkflamesensor,diagramandtableofvalues,seePage32,

    ifok—>replacecontrolbox.

    057 Flamecutoutfromstartphase(Displayonlyifheaterslabelled“H-Kit”onthenameplate.)

    Aflamecutoutwasdetectedduringthestartphase..• Checkexhaustandcombustionairsystem.• Checkfuelsupply/measurefuelquantity,seePage36.• Checkglowplug(seefaultcode020and021).• Checkflamesensor,diagramandvaluestable,seepage32,

    ifok—>replacecontrolbox.

    060 Externaltemperaturesensor–interruption

    • DisconnecttheconnectorS4/B4oftheexternaltemperaturesensorandmeasuretheresistancevalueatconnectorB2,fordiagramandtableofva-luesseePage12,iftemperaturesensorok,reassembleconnectorS4/B4.

    • DisconnectconnectorS1/B1attheheaterandmeasuretheresistancevalueinconnectorhousingB1betweenPIN6andPIN12.Ifinterruptedtheohmicvalueis>7175/3k*.Ifresistancevalueok—>replacecontrolbox.

    * Thisfaultcodeorohmicvalueisvalidforanewgenerationcontrolboxonly.Thisdiffersfromthecontrolboxtodatebyitscableloomwrappedincabletapeandbyatemperaturesensormountedontheside,whichbecomesvisiblewhenthecoverisremoved.

  • 26

    Troubleshooting4Fault codeDisplay

    Fault description Comments• Remedial action

    061 Externaltemperaturesensor–shortcircuit

    • DisconnectconnectorS4/B4oftheexternaltemperaturesensor,iffaultcode060isdisplayed—>checkexternaltemperaturesensor,diagramandtableofvalues,seePage32.Iftemperaturesensorok—>checkconnec-tioncables0.5grand0.5br/wsforshortcircuit,ifok,reassemblethecon-nectorS2/B2.

    • DisconnectconnectorS1/B1attheheaterandmeasuretheresistancevalueinconnectorhousingB1betweenPIN6andPIN12.Incaseofshortcircuittheohmicvalueis<486/<800*.

    Iferror061continuestobedisplayed—>replacecontrolbox.

    062 Controlunit–interruption

    Please note!

    Refertonotesondiagnosiswithmini-controlleronpage14.

    Heaterrunsin„High“controlstageonly• Removeconnectoratthecontrolunitandmeasuretheresistancevalueof

    thesetpointpotentiometer,forconnectorpinsseePage42onwards.Iftheresistancevalueisok,reconnectconnectoratthecontrolunit.

    • DisconnectconnectorS1/B1attheheater,measuretheresistancevaluebetweenPIN6andPIN7inconnectorhousingB1,ifresistancevalueok—>replacecontrolbox.Resistancevalueincaseofinterruption>7175 />3k *.Normalvalues:seepage12.

    063 Controlunit–shortcircuit

    Faultrecognitiononlyworksinhea-tingmode.If,ontheotherhand,theshortcircuithasalreadyoccurredandthentheheaterisswitchedon,„Venti-lation“isactive(notafaultcode).

    • Ifthe“Ventilate”switchisinstalled,disconnectitandcheckitworks.Ifnotok—>replaceswitch.

    • Disconnectconnectoratcontrolunit,iferrorcode062isdisplayed,replacethecontrolunit.Ifcontrolunitok,checkconnectioncables0.5gr/rtand0.5br/wsforshortcircuit,ifok—>reconnectconnectoratcontrolunit.

    • DisconnectconnectorS1/B1attheheater,iftheerror063continuestobedisplayed—>replacecontrolbox.Resistancevalueincaseofshort-circuit<486 / <800 *.Normalvalues:seepage12.

    064 Flamesensor–interruption • Dismantlecontrolboxanddisconnectgreenconnectorfromcontrolbox.Checkflamesensor,diagramandtableofvalues,seePage32,ifflamesen-sorok—>replacecontrolbox.Resistancevalueincaseofinterruption>7175 />3k *.

    065 Flamesensor–shortcircuit Dismantlecontrolbox,removegreenconnectorfromcontrolbox,iferror064isdisplayed—>replacecombinationsensor.

    Iferror065continuestobedisplayed—>replacecontrolbox. Resistancevalueincaseofshortcircuit<486 /<500*,seealsodia-

    gramonPage32.

    071 Overheatingsensor–interruption • Dismantlecontrolbox,disconnectblueandgreenconnectorsfromcontrolbox.MeasureresistancevalueatblueconnectorPIN1(cable0.52bl)andatgreenconnectorPIN2(cable0.52br/ws),ifok,—>replacecontrolbox.

    Resistancevalueincaseofinterruption>223k />1600k *,seealsodiagramonPage32.

    072 Overheatingsensor–shortcircuit • Dismantlecontrolbox,removeblueconnectorfromcontrolbox,iferror071isdisplayed—>replacecombinationsensor.

    Iferror072continuestobedisplayed—>replacecontrolbox. Resistancevalueincaseofshortcircuit<183 /<95*,seealsodia-

    gramonPage32.

    074 * Controlboxdefective • Overheatingthresholdvalueisnotdetectedbycontrolbox—>replacecon-trolbox.

    090 Controlboxdefective(internalfault) • Replacecontrolbox.

    091 Externalinterferencevoltage • Controlboxfaultduetointerferencevoltagesfromthevehicle’selectricalsystem.Possiblecauses:

    Poorbattery,charger—>removeinterferencevoltage.

    092 Controlboxisdefective(ROMerror) • Replacecontrolbox.

    093 * Controlboxdefective • Replacecontrolbox.

    * Thisfaultcodeorohmicvalueisvalidforanewgenerationcontrolboxonly.Thisdiffersfromthecontrolboxtodatebyitscableloomwrappedincabletapeandbyatemperaturesensormountedontheside,whichbecomesvisiblewhenthecoverisremoved.

  • 27

    Troubleshooting4Fault codeDisplay

    Fault description Comments• Remedial action

    094 Controlboxdefective(EEPROM-Fehler)

    • Replacecontrolbox.

    095 * Controlboxdefective • Replacecontrolbox.

    096 Internaltemperaturesensordefective • Replacecontrolboxoruseanexternalroomtemperaturesensor..

    097 Controlboxdefective • SReplacecontrolbox.

    098 * Controlboxdefective • Replacecontrolbox.

    099 * Toomanyresetsinsequence

    Transistorerrorincontrolbox

    • Voltageshort-term<5–6volt(for12volt)or<7–8volt(for24volt). Incaseofavoltagedrop,checkthefuses,thesupplycables,thenegative

    connectionsandthepositivesupportpointonthebatteryforcorrosionandcorrectcontact.

    Testcontrolboxwithtestingdevice,ifok—>checkleadharnessoftheex-ternalcomponentshasbeencorrectlylaidandcheckfordamage,ifok—>checkleadharnessforcontinuity,ifok—>replacecontrolbox.

    Air pressure sensor fault code displayFault code display

    Fault description Comments• Remedial action

    0 Nofaults —

    11 Communicationloss Interruptionofthediagnosticscablebetweenthecontrolbox(heater)andtheairpressuresensor• Checkwiringandplug-inconnections

    12 Noaltitudeadjustment Controlbox(heater)doesnotsupportaltitudeoperationwiththeairpressuresensor• Useacontrolbox(heater)whichsupportsaltitudeadjustment

    13 Airpressuresensorfault Theairpressuresensorisdefective• Replacetheairpressuresensor

    * Thisfaultcodeorohmicvalueisvalidforanewgenerationcontrolboxonly.Thisdiffersfromthecontrolboxtodatebyitscableloomwrappedincabletapeandbyatemperaturesensormountedontheside,whichbecomesvisiblewhenthecoverisremoved.

  • 28

    Repair instructions

    Thepermittedrepairworktotheheaterisdescribedinthe“RepairInstructions”chapter.Ifextensiverepairsarenecessary,itmakessensetodismantletheheater.

    Theheaterisassembledinthereverseorder,ifapplicablenotadditionalinstructions.

    Aftercompletingalltheworkontheheater,youmustcarryoutafunctionalcheck(seePage4).

    Always observe the following safety instructions before working on the heater:

    Danger!Risk of injury, burns and poisoning!• Alwaysswitchofftheheaterbeforehandandleaveittocool.• Disconnectthebattery.• Theheatermustnotbeoperatedinclosedroomssuchas

    garagesorworkshops. Exception: Exhaustsuctionavailabledirectlyattheentrytotheexhaust

    pipe.

    Caution!• Thesealsofdismantledcomponentsmustberenewed.• Duringrepairwork,checkallcomponentsfordamageandif

    necessaryreplace.• Checkconnectorcontacts,plug-inconnectionsandcables

    forcorrosionanddamageandifnecessaryrepair.• OnlyeveruseEberspächersparepartsifreplacementsare

    necessary.• Operationortheafterrunningoftheheatermayonlybe

    stoppedinanemergency(see“EMERGENCYOFF”Page8)byinterruptingthebatterycurrent(riskofheateroverheat-ing).

    Repairinstructions5Special tool

    AMP release tool

    TheAMPreleasetoolisusedtoreleaseplug-incontactsinaconnectorhousing.

    ThisreleasetoolcanbeordereddirectlyfromAMP.

    • ForMicroTimer: AMPOrderNo.0-0539960-1

    • ForJunior-Power-Timer: AMP-Bestell-Nr.1-1579007-6

    Please note!

  • 29

    Assembly drawing Airtronic / Airtronic M

    Partslist

    1 Combustionairfan 2 Seal–combustionairfan/heatexchanger 3 Combustionchamber 4 Seal–combustionchamber/heatexchanger 5 Heatexchanger 6 Controlbox 7 Combinationsensor(overheating/flamesensor)with

    assemblytool

    8 Bracket 9 Glowplug,withspecialtool(SW12)10 Lining–glowplugsocket,withassemblytool11 Cover12 Outershell(bottomsection)13 Flangeseal14 Sleeve(forpetrolonly)

    Repairinstructions5

  • 30

    Repair step 1Remove the heater’s cover (seeFigure1)

    Unlockbothfasteningclips,liftthecoverandremovefromthefront.

    Theheater’scovermustberemovedforallrepairsteps.Ifnecessary,waituntiltheunithascooleddown.

    Cableharnessoutletfromthehousingoptionallyonleftorright-handside.

    1. 2.

    Figure1

    Cover Fasteningclips

    Repair step 2Dismantle control box (seeFigure2)

    • Repairstep1.• Unscrewfixingscrew,• Presstogethertheretainingclamps.• Removethecontrolboxfromabove.• Unclipcablesfromholderoncontrolbox (Notethepositionofthecables).• Pullgrommetoutoftheoutershell(bottomsection).• Pullconnectoroutofcontrolbox,thecontrolboxcannow

    beremoved.

    Whenassemblingthecontrolbox,ensurethecablesareclip-pedintotheholderonthecontrolboxandtheconnectorsarepluggedintothecontrolbox(unmistakeable).TighteningtorqueofthefixingscrewItem:2+0.2Nm

    Figure2

    Fixingscrew Retainingclamp Controlbox Grommet

    Check control box

    TheEDiTHdiagnostictoolisrequiredtocheckthecontrolboxwhenitisdismantled.Forconnection,useandOrderNo.,seePage19.

    5 Repairinstructions

    Please note!

    Please note!

  • 31

    Repair step 3Dismantle glow plug (seeFigure3)

    Important!Safety instruction for installation of the rubber grommetTopreventleaks,inserttherubbergrommetpreciselyintheglowplugholeintheheatexchanger.Failuretocomplywiththisinstructioncanresultinpersonalinjuriesaswellasmalfunctioningordamagetotheheater.

    • Repairstep2.• Disconnectconnectorfrom“glowplug”cableloomoncon-

    trolbox.• Removerubbergrommetandunscrewtheglowplugusing

    thespecialtool(SW12).(Thespecialtoolisincludedwiththeglowplug).

    Tighteningtorqueforglowplug:6+0.5Nm

    Specialglowplugtool

    Figure3

    Glowplug Connectorfromglowplugcableloom Rubbergrommet

    Please note!

    Withtheglowplugdismantled,visuallycheckthesocketliningoftheinstalledglowplugfordirt.Iftheliningishighlysoiledanditssurfaceclosed,renewthelining.

    Removing the lining (see Figure 4)

    Uselongnoseplierstopulltheliningoutofthesocketfromabove.Blowoutthesocketwithcompressedairandifnecessarycleanthesideventhole.

    Usethespecialtooltoinstallthenewlining.Thespecialtoolisincludedwiththelining.Pushtheliningonthetool.Pushinthetooltogetherwiththelininguptothelimitstop.Welding points of lining must lie opposite the fuel intake.

    Figure4

    Specialtool Lining

    5

    Repairinstructions

  • 32

    Repair step 5 Dismantle combination sensor (overheating / flame sen-sor) (seeFigure5)

    • Repairstep2.• Removebothconnectorsfromthe“combinationsensor”

    cableloomatthecontrolbox.• Unlockbracketfromcombinationsensor.• Removethecombinationsensor.

    Figure5

    “Combinationsensor”cableloom Bracket,unlocked

    Check combination sensor

    Theexternaltemperaturesensormustbecheckedwithadigi-talmultimeter.Replacetheoverheatingorflamesensoriftheresistancevalueisnotthesameasthecurveinthediagramorthetableofvalues.

    Table of overheating sensor values

    Temperature °C Resistance k min. max. – 40 1597.00 1913.00 – 20 458.80 533.40 0 154.70 175.50 20 59.30 65.84 40 25.02 28.04 60 11.56 13.16 80 5.782 6.678 100 3.095 3.623 120 1.757 2.081 140 1.050 1.256 160 0.6554 0.792 180 0.4253 0.5187 200 0.2857 0.3513

    Table of flame sensor values

    Temperature °C Resistance min. max.– 40 842.7 825.9 859.6– 20 921.6 803.2 940.0 0 1000.0 980.0 1020.0 20 1077.9 1056.4 1099.5 40 1155.4 1132.3 1178.5 60 1232.4 1207.8 1257.1 80 1308.9 1282.8 1335.1 100 1385.1 1357.4 1412.8 120 1460.7 1431.5 1489.9 140 1535.8 1505.1 1566.6 160 1610.5 1578.3 1642.8

    Res

    ista

    nce

    (kO

    hm)

    Temperature(°C)

    5

    Notethemax.temperatureof320°Cforthetest.

    Temperature(°C)

    Res

    ista

    nce

    (Ohm

    )

    Overheating sensor Flame sensor

    Repairinstructions

    Please note!

  • 33

    Sketch2

    Specialtool–onlyrequiredforAirtronic Combinationsensor

    Figure6

    Specialtool–onlyrequiredforAirtronic Combinationsensor

    Repair step 6 Install combination sensor (overheating / flame sensor)(seeFigure6,7andSketch2–4)

    •Repairstep2.• ForAirtronic(assemblywithspecialtool,seeSketch2) Pushthespecialtoolaontothecombinationsensorb.Use

    thespecialtooltopositionthecombinationsensorontheheatexchanger,thespecialtoolslidesontheheatexchang-eruntilthecombinationsensorhitsthecollar(installationpositionofthecombinationsensor).

    Lockthecombinationsensor’sbracketandremovethespecialtool.Thenalwayscheckthatthecombinationsen-sorsitsflatontheheatexchanger.Ifnecessary,useaidssuchasamirrorandlamp.

    Laythe“combinationsensor”cableloomalongthebracket,throughthebracketeyeletuptothecontrolboxandcon-nect.

    • ForAirtronicM(assemblywithoutspecialtool) Placethecombinationsensorontheheatexchanger;itis

    importanttoensurethecombinationsensorsitsflatontheheatexchanger.

    Lockthecombinationsensor’sbracketandcheckagainthatthecombinationsensorissittingflatontheheatex-changer.

    Laythe“combinationsensor”cableloomalongthebracket,throughthebracketeyeletuptothecontrolboxandcon-nect.

    Sketch4

    Bracket Combinationsensor

    Figure7

    Bracket,locked “Combinationsensor”cableloom Specialtool–onlyrequiredforAirtronic

    Circuit diagram for combination sensor (overheating sensor / flame sensor)

    Sketch3

    NTC50KΩ=overheatingsensorPT1000=flamesensor

    Connectorblue

    Connectorgreen

    5 Repairinstructions

  • 34

    Repair step 7 Dismantle heat exchanger (seeFigure8andSketch5)Dismantle combustion air fan (seeFigure8andSketch5)

    • Repairstep2.• Removeflangeseal.Removeheaterfromtheoutershell

    (bottomsection). Unscrewthe4fixingscrewsfromthecombustionairfan. Removethecombustionairfanandthesealfromtheheat

    exchanger.

    Caution!Wheninstallingthecombustionairfanthesealmustalwaysberenewed.

    Tightenthe4fixingscrewsofthecombustionairfan–intheordershowninSketche–withatighteningtorqueof4+0.5Nm. Figure8

    Combustionairfan Heatexchanger Fixingscrew

    Sketch5

    1–4 Tightenthefixingscrewsinthisorderwithatightening

    torqueof4+0.5Nm

    5

    5 Alwaysrenewthesealbetweenthecombustionairfanandtheheatexchanger.

    5

    2

    4

    3

    1

    Repairinstructions

  • 35

    Repair step 8Dismantle combustion chamber (seeFigure9andSketch6)

    • Repairstep3.• Repairstep7.• Unscrewthefixingscrews. IntheAirtronic=3fixingscrews, intheAirtronicM=4fixingscrews.• Pulloutthecombustionchamberfromthefrontandremove

    theheatexchanger’sseal.

    Caution!Whenassemblingthecombustionchamber,alwaysrenewtheseal,whichisincludedwiththesparepart.

    Tightenthefixingscrewsofthecombustionchamberwithatighteningtorqueof5+0.5Nm

    Iftheheatexchangerisreplacedthecombinationsensor(overheatingsensor/flamesensor)mustbedismantledandfittedonthenewheatexchanger(seeRepairstep6,Page33).

    Sketch6

    1Combustionchamber2Alwaysrenewthesealbetweenthecombustionchamber

    andtheheatexchanger.3Heatexchanger

    4Fixingscrew Airtronic=3fixingscrews AirtronicM=4fixingscrews

    Figure9

    Combustionchamber Heatexchanger Fixingscrew Airtronic=3fixingscrews AirtronicM=4fixingscrews

    5

    4

    1

    2

    3

    Repairinstructions

    Please note!

  • 36

    Measuring the fuel quantity

    1. Preparation

    Removethefuelpipeattheheaterandinsertameasuringcylinder(size10ml).Switchontheheater,ifthefuelisuniformlypumped(beginsapprox.60secafterbeingswitchedon),thefuelpipeisfullandvented.Switchoffheaterandemptymeasuringcylinder.

    Forprecisefuelmeasurementatleast11volt/22voltormaximum13volt/26voltshouldbeappliedtothecontrolboxduringthemeasurement.

    2. Measurement

    Thefuelbeginstobepumpedapprox.60secafterswitchingontheheater.Holdthemeasuringcylinderatglowpluglevelduringthemeasurement.

    Airtronic Afterapprox.90secofthefuelbeingpumpeditisautomati-callyswitchedoff.

    Caution!Switch off heater,asotherwiseitwillstartupagain.

    Readoffthequantityoffuelinthemeasuringcylinder.

    Airtronic MAfterapprox.105secofthefuelbeingpumpeditisautomati-callyswitchedoff.

    Caution!Switch off heater,asotherwiseitwillstartupagain.

    Readoffthequantityoffuelinthemeasuringcylinder..

    Ifthemeasuredfuelquantityliesoutsidethevaluesgivenbelow,themeteringpumpmustbereplaced.

    1 Heater2 Meteringpump

    Check fuel supply

    Beforemeasuringthefuelquantity,checkthefollowingpointsinthefuelsupply.

    • Checkthescreeninthemeteringpump.• Checkthelayingofthefuelpipes.• Checkfuelpipesforleaks.• Checkandtightenthehoseconnections.• Isthefuelremovalinstalledaccordingtothedetailsinthe

    technicaldescription?

    5

    3 Measuringcylinder(size10ml)4 Disconnectfuelpipeatheaterandinsertinameasuringcylinder.

    1

    2

    3

    4

    Table of values – fuel quantity

    Heater Fuel Fuel quantity

    Minimal Maximal

    Airtronic diesel 3,5ml/90sec 4,3ml/90sec

    AirtronicM petrol 6,8ml/105sec 7,6ml/105sec

    AirtronicM diesel 5,0ml/105sec 6,0ml/105sec

    Bitte beachten!

    Repairinstructions

  • 37

    Circuitdiagram6Overview of the parts lists and circuit diagrams

    PartslistcircuitdiagramAirtronic/AirtronicM................................................................................................................................ 38CircuitdiagramAirtronic/AirtronicM.............................................................................................................................................. 39 Thiscircuitdiagramisforheaterswithonediagnosticscableandacontrolboxcableloomwhichisfirmlyencapsulated.CircuitdiagramAirtronic/AirtronicM.............................................................................................................................................. 40 Thiscircuitdiagramisforheaterswith2diagnosticscableandwhosecontrolboxcableloomiswoundwithcabletape.

    Partslistcontrolunits..................................................................................................................................................................... 41Circuitdiagramscontrolunits...................................................................................................................................................42–48

    PartslistEasyStartR+/R/Tcontrolunits..................................................................................................................................... 49EasyStartR+circuitdiagram...................................................................................................................................................50–52EasyStartRcircuitdiagram......................................................................................................................................................53–55EasyStartTcircuitdiagram....................................................................................................................................................... 56,57

    PartslistcircuitdiagramAirtronic/AirtronicM–ADR..................................................................................................................... 58CircuitdiagramAirtronic/AirtronicM–ADR................................................................................................................................... 59 Thiscircuitdiagramisforheaterswithonediagnosiscableandacontrolboxcableloomwhichisfirmlyencapsulated.CircuitdiagramAirtronic/AirtronicM–ADR................................................................................................................................... 60 Thiscircuitdiagramisforheaterswith2diagnosticscableandwhosecontrolboxcableloomiswoundwithcabletape.

    Partslistcontrolunits–ADR.......................................................................................................................................................... 61Circuitdiagramcontrolunits–ADR............................................................................................................................................... 62EasyStartT–ADRcircuitdiagram............................................................................................................................................ 63,64

  • 38

    Parts list circuit diagrams Airtronic / Airtronic M

    1.1 Burnerengine1.2 Glowplug1.5 Overheatingandflamesensor2.1 Controlbox2.2 Meteringpump2.7 Mainfuse 12volt=20A 24volt=10A2.7.1Fuse,actuation5A5.1 Battery

    a) Connectionofcontrolunitandexternalsensoraccord-ingto“controlunits”circuitdiagram

    •rt Powersupply,plus–terminal30 •ge Switch-onsignal–S+ •gr Temperature–actualvalue •wsrt Switchofftheanti-theftalarmsystem (ADR–feedbacksignalfortimer) •br Powersupply,minus–terminal31 •blws Diagnosis •grrt Temperature–setpoint •brws Groundconnectionforexternaltempera-

    turesensorandtemperaturesetpoint b) Option •Vehiclefancontrol and/or •separatefreshairfan

    Thecircuitdiagramsareassignedviatheinstalledcontrolbox:• Controlboxwithonediagnosticscable: Atthe16pinconnectorthediagnosticscablebl/wsiscon-

    nectedtochamber8.• Controlboxwith2diagnosticscablesandJEdiagnosis: Atthe16pinconnectorthediagnosticscablebl/wsis

    connectedtochamber3,thediagnosticscablebl/geisconnectedtochamber8.

    • Insulateunusedcableends.• Connectorsandbushhousingsareshownfromthecable

    inletside.

    Circuitdiagram6

    Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple

    Please note!

  • 39

    Circuit diagram – Airtronic / Airtronic M

    252069009801APartslistPage38

    Circuitdiagram6

    Thiscircuitdiagramisforheaterswithadiagnosticscableandwhosecontrolboxcableloomwhichisfirmlyencapsulated.

    Please note!

  • 40

    Circuit diagram – Airtronic / Airtronic M

    Circuitdiagram6

    Thiscircuitdiagramisforheaterswith2diagnosticscableandwhosecontrolunitcableloomiswoundwithcabletape.

    252069009801BPartslistPage38

    Bitte beachten!

  • 41

    Circuitdiagram6Parts list circuit diagrams, control units

    2.15.1 Temperaturesensor,external(roomtemperature)2.15.9 Temperaturesensor(externaltemperature)3.1.9 Changeoverswitch“heat/ventilate”3.1.11 Controlunit,round3.1.16 Radioremotecontrolbutton3.1.17 MinicontrollerAirtronic3.1.18 ButtonCalltronic3.2.8 Moduletimer(ADR–potentiometer)3.2.12 Timer,mini–12/24volt3.2.14 Lighting,timer,mini–12voltonly3.3.6 RadioremotecontrolstationarypartTP41i3.3.7 RadioremotecontrolstationarypartTP53.3.8 RemotecontrolCalltronic3.8.3 Antenna3.9.1 Diagnosis,JEdiagnosis

    a)ConnectioncontrolelementstotheAirtronic •rt Powersupply,plus–terminal30 •ge Switch-onsignal–S+ •gr Temperature–actualvalue •wsrt Switchoffburglaralarm (ADR–feedbackfortimer) •br Powersupply,minus–terminal31 •blws Diagnosis •grrt Temperature–setpoint •brws Groundconnectionforexternaltempera-

    turesensorandtemperaturesetpoint b) Terminal15–necessaryforconnectionTP4i c) Lighting,terminal58d) Connection,diagnosticunit e) Connection,externaltemperaturesensor g) Connection,externalheatingbutton h) Connection,radioremotecontrolTP4i j) Connection,temperaturesensor(outsidetemperature) k) Ifconnectingtimerorradioreceiver– Disconnectcablehere l) Connection,change-overswitch“heat/ventilate” option) Initialoperation:Activatechangeoverswitch “heat/ventilate”,thenswitchontheheater. z) Lighting,terminal58

    • Insulateunusedcableends.• Connectorsandbushhousingsareshownfromthecable

    inletside.

    Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple

    Please note!

  • 42

    Circuit diagram, control units – part 1

    252069009701CPartslistPage41

    Circuitdiagram6

  • 43

    Circuitdiagram6

    252069009701CPartslistPage41

    Circuit diagram, control units – part 2

  • 44

    Circuit diagram, control units – part 3

    252069009702APartslistPage41

    Circuitdiagram6

  • 45

    Circuit diagram, control units – part 4

    252069009702APartslistPage41

    Circuitdiagram6

  • 46

    Circuit diagram, control units – part 5

    252069009704APartslistPage41

    Circuitdiagram6

  • 47

    Circuit diagram, control units – part 6

    252069009704APartslistPage41

    Circuitdiagram6

  • 48

    Circuit diagram, control units – part 7

    PartslistPage41

    Circuitdiagram6

    252069009703B

  • 49

    Circuitdiagram6Parts list circuit diagram control units – EasyStart R+ / R / T

    2.15.1 Temperaturesensor(roomtemperature) (includedinscopeofsupplyforEasyStartR+, optionalforEasyStartR/T)2.15.9 Outsidetemperaturesensor(optional)

    3.1.7 “OFF”button3.1.9 “Heat/ventilate”switch3.1.11 “Round”controlunit3.1.16 Radioremotecontrolbutton3.1.17 “Minicontroller”controlunit

    3.2.15 EasyStartTtimer

    3.3.9 RadioremotecontrolEasyStartR(stationaryunit)3.3.10 RadioremotecontrolEasyStartR+(stationaryunit)

    3.6.1 Leadharness

    3.8.3 Antenna

    a) Connectionofcontrolunitsattheheaterc) Terminal58(lighting)d) Parkingventilationwithvehiclefan(optional)e) ConnectionofEasyStartTtimertimerg) Connection“ON/OFF”key (optionale.g.OrderNo.:221000328400)h) Connectionof“Ventilate”viaEasyStartR+x) ADRjumpery) Connectandinsulatecables

    •Note heater type!•Thejumperlabelledwithy)inthecircuitdiagrammustalways

    beconnected.•Insulateunusedcableends.•Connectorsandbushhousingsareshownfromthecable

    inletside.

    Assignment of the circuit diagrams for Airtronic heatersThecircuitdiagramsareassignedviatheinstalledcontrolbox:• Controlboxwithonediagnosticscable: Atthe16pinconnectorthediagnosticscablebl/wsiscon-

    nectedtochamber8.• Controlboxwith2diagnosticscablesandJEdiagnosis: Atthe16pinconnectorthediagnosticscablebl/wsis

    connectedtochamber3,thediagnosticscablebl/geisconnectedtochamber8.

    Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple

    Please note!

    EasyStart TPinassignmentEasyStartT-connectorS1

    1 Terminal 30 (positive) rt 2 S+(switchingonsignal) ge 3 Terminal 31 (negative) br 4 DATcable vi 5 Diagnosis cable (K line) bl/ws 6 Terminal58 gr/sw 7 Temperaturesensor(positive)) gr 8 Temperaturesensor(negative) br/ws 9 –– ––

    EasyStart R Pinassignmentatthestationaryunitconnector

    1 Terminal31(negative) 2 –– 3 –– 4 DATcable 5 Pushbutton/LED(negative) 6 –– 7 Terminal30(positive) 8 S+(switching on signal) 9 LED(positive)10 Diagnosiscable(Kline))11 Pushbutton(negative)12 ––

    EasyStart R+ Pinassignmentatthestationaryunitconnector

    1 Terminal31(negative) 2 –– 3 Ventilate(switchingsignal–) 4 DATcable 5 Pushbutton/LED(negative) 6 Temperaturesensor(negative) 7 Terminal30(positive) 8 S+(switchingonsignal) 9 LED(positive)10 Diagnosiscable(Kline)11 Pushbutton(negative)12 Temperaturesensor(positive)

    Pin assignments

  • 50

    Circuitdiagram6EasyStart R+ control unit circuit diagram(Controlboxwithonediagnosticscable)

    PartslistPage49 252069009706B

  • 51

    Circuitdiagram6

    PartslistPage49 252069009706B

    EasyStart R+ control unit circuit diagram(Controlboxwithonediagnosticscable)

  • 52

    Circuitdiagram6EasyStart R+ control unit circuit diagram(Controlboxwithtwodiagnosticscables)

    PartslistPage49 252361009701B

  • 53

    Circuitdiagram6EasyStart R control unit circuit diagram(Controlboxwithoneortwodiagnosticscables)

    PartslistPage49 252361009705B

  • 54

    Circuitdiagram6EasyStart R control unit circuit diagram(Controlboxwithtwodiagnosticscables)

    PartslistPage49 252361009702B

  • 55

    Circuitdiagram6EasyStart R control unit circuit diagram(Controlboxwithonediagnosticscable)

    PartslistPage49 252069009707B

  • 56

    Circuitdiagram6EasyStart T control unit circu