Top Banner
Airtronic M Order no. Airtronic D3, 12 V 25 2317 05 00 00 Airtronic B4, 12 V 20 1812 05 00 00 Airtronic D4, 12 V 25 2113 05 00 00 Airtronic D4, 24 V 25 2114 05 00 00 Airtronic D4 Plus, 12 V 25 2484 05 00 00 Airtronic D4 Plus, 24 V 25 2489 05 00 00 Airtronic D4S, 12 V 25 2144 05 00 00 Airtronic D4S, 24 V 25 2145 05 00 00 Airtronic D3 Camper, 12 V (see Airtronic D3) Airtronic D4 Camper, 12 V 25 2318 05 00 00 Airtronic D4 Camper plus, 12 V 25 2327 05 00 00 AIRTRONIC / AIRTRONIC M Troubleshooting and Repair Instructions 25 2115 95 19 01 04.2009 Airtronic Order no. Airtronic D2, 12 V 25 2069 05 00 00 Airtronic D2, 24 V 25 2070 05 00 00 Airtronic D2 Camper, 12 V 25 2326 05 00 00 Complete package Airtronic D2, 12 V 25 2115 05 00 00 Airtronic D2, 24 V 25 2116 05 00 00 Air heater for diesel and petrol operating independently of the engine. http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic
70

AIRTRONIC / AIRTRONIC M - Eberspachereberspacher.frl/wp-content/uploads/D2-Airtronic-werkplaatshandleiding.pdfAirtronic M Order no. Airtronic D3, 12 V 25 2317 05 00 00 Airtronic B4,

Jan 27, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • Airtronic M Orderno.

    AirtronicD3,12V 252317050000

    AirtronicB4,12V 201812050000

    AirtronicD4,12V 252113050000AirtronicD4,24V 252114050000

    AirtronicD4Plus,12V 252484050000AirtronicD4Plus,24V 252489050000

    AirtronicD4S,12V 252144050000AirtronicD4S,24V 252145050000

    AirtronicD3Camper,12V(seeAirtronicD3)

    AirtronicD4Camper,12V 252318050000

    AirtronicD4Camperplus,12V 252327050000

    AIRTRONIC / AIRTRONIC MTroubleshooting and Repair Instructions

    25211595190104.2009

    Airtronic Orderno.

    AirtronicD2,12V 252069050000AirtronicD2,24V 252070050000AirtronicD2Camper,12V 252326050000

    Completepackage

    AirtronicD2,12V 252115050000AirtronicD2,24V 252116050000

    Air heater for diesel and petroloperating independently of the engine.

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

    www.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.comwww.butlertechnik.com

  • 2

    4

    3

    1

    2

    1Contents

    ThislistofcontentsgivesyoupreciseinformationaboutthecontentsoftheTroubleshootingandRepairInstructions.

    Introduction

    Usetheindex,listofabbreviations,etc,tolookforaterm,technicalwordoranexplanationforanabbreviation.

    Chapter Title Contents Page

    Introduction • Foreword.................................................................................................................. 4• Accidentprevention.................................................................................................. 4• Specialtextstructure,presentationandpicturesymbols........................................... 4• Importantinformationbeforestartingwork................................................................ 4

    Function and use Cutawayview............................................................................................................ 5• Descriptionoffunctions– Switchingon.......................................................................................................... 6– StartingtheAirtronic.............................................................................................. 6– StartingtheAirtronicM.......................................................................................... 6– Temperatureselectionwiththecontrolelement...................................................... 6– Controlinheatingmode......................................................................................... 6– Ventilatingmode.................................................................................................... 6– Switchingoff.......................................................................................................... 6

    • Controlandsafetydevices........................................................................................ 7– Forcedshut-downforADRoperation..................................................................... 7– Emergencyshutdown–EMERGENCYOFF........................................................... 7

    Technical data • Airtronic(fordiesel)................................................................................................... 8• AirtronicM(forpetrol)................................................................................................ 9• AirtronicM(fordiesel)........................................................................................ 10,11• Checkvalues– Testspeedfortheblower..................................................................................... 12– Resistan\cevalues............................................................................................... 12– Switchingvalue.................................................................................................... 12– Exhaustemissionspecification............................................................................. 12– Check“externaltemperaturesensor”................................................................... 12– Tableofvalues:“Externaltemperaturesensor”..................................................... 12

    Troubleshooting • Whattocheckfirstincaseoffaults– Check.................................................................................................................. 13– Electricalcomponents.......................................................................................... 13–Measurebatteryvoltage....................................................................................... 13–Measuresvoltagesupply..................................................................................... 13– Checkswitch-onsignal........................................................................................ 13– Checkcontrolunit................................................................................................ 13

    •Overviewoftheindividualtestequipmentandcontrolunits..................................... 14• Lockingthecontrolbox........................................................................................... 14• Cancelthecontrolboxlock..................................................................................... 14• Importantnotes(diagnosisofheaterswithmini-controller)....................................... 14• Testingdeviceforthecontroldevice........................................................................ 15• Faultdiagnosisusingthediagnosticunit........................................................... 15,16• FaultdiagnosisusingtheEDiTHdiagnosticstoolwithISOadapter.......................... 17• AirpressuresensordiagnosisusingEDiTHdiagnosticstoolandISOadapter.......... 18• FaultdiagnosisusingtheEDiTHdiagnosticstoolwithbasicadapter....................... 19• Faultdiagnosisusingthemoduletimer.................................................................... 20• FaultdiagnosisusingtheradioremotecontrolTP5................................................. 21• FaultdiagnosisusingtheEasyStartR+radioremotecontrolortheEasyStartTtimer............................................................................................... 22

    • Faultcodetable...............................................................................................23–27

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 3

    Introduction

    7

    6

    5

    1

    Chapter Title Contents Page

    Repair instructions • Repairinstructions.................................................................................................. 28• Alwaysobservethefollowingsafetyinstructionsbeforeworkingontheheater........ 28• Specialtool,AMPreleasetool................................................................................. 28• AssemblydrawingAirtronic/AirtronicM................................................................. 29• Repairstep1,removetheheatercover................................................................... 30• Repairstep2,dismantlecontrolbox,checkcontrolbox......................................... 30• Repairstep3,dismantleglowplug.......................................................................... 31• Repairstep4,renewlining...................................................................................... 31• Repairstep5,dismantlecombinationsensor(overheating/flamesensor............... 32• Repairstep6,installcombinationsensor(overheating/flamesensor)..................... 33• Repairstep7,dismantleheatexchanger/dismantlecombustionairfan................................................................................... 34

    • Repairstep8,dismantlecombustionchamber........................................................ 35• Checkfuelsupply.................................................................................................... 36•Measuringthefuelquantity...................................................................................... 36

    Circuit diagrams Overviewofthepartslistsandcircuitdiagrams........................................................... 37• PartslistcircuitdiagramsAirtronic/AirtronicM....................................................... 38• CircuitdiagramAirtronic/AirtronicM..................................................................... 39Thiscircuitdiagramisvalidforheaterswithonediagnosiscableandacontrolboxcableloomwichisfirmlyencapsulated.

    • CircuitdiagramAirtronic/AirtronicM..................................................................... 40Thiscircuitdiagramisforheaterswith2diagnosticscableandwhosecontrolboxcableloomiswoundwithcabletape.

    • Partslistcircuitdiagrams,controlunits.................................................................... 41• Circuitdiagramcontrolunits–part1....................................................................... 42• Circuitdiagramcontrolunits–part2....................................................................... 43• Circuitdiagramcontrolunits–part3....................................................................... 44• Circuitdiagramcontrolunits–part4....................................................................... 45• Circuitdiagramcontrolunits–part5....................................................................... 46• Circuitdiagramcontrolunits–part6....................................................................... 47• Circuitdiagramcontrolunits–part7....................................................................... 48• PartslistcircuitdiagramcontrolunitEasyStartR+/R/T........................................ 49• CircuitdiagramcontrolunitEasyStartR+(controlboxwith1diagnosticscable)...... 50• CircuitdiagramcontrolunitEasyStartR+(controlboxwith1diagnosticscable)...... 51• CircuitdiagramcontrolunitEasyStartR+(controlboxwith2diagnosticscable)...... 52• CircuitdiagramcontrolunitEasyStartR(controlboxwith1/2diagnosticscables). 53• CircuitdiagramcontrolunitEasyStartR(controlboxwith2diagnosticscables)...... 54• CircuitdiagramcontrolunitEasyStartR(controlboxwith1diagnosticscables)...... 55• CircuitdiagramcontrolunitEasyStartT(controlboxwith1diagnosticscable)........ 56• CircuitdiagramcontrolunitEasyStartT(controlboxwith2diagnosticscable)........ 57• PartslistcircuitdiagramsAirtronic/AirtronicM–ADR............................................ 58• CircuitdiagramAirtronic/AirtronicM–ADR.......................................................... 591encapsulateddiagnosticscableandcontrolboxcableloomfirmlyencapsulated

    • CircuitdiagramAirtronic/AirtronicM–ADR.......................................................... 602diagnosticscablesandcontrolboxcableloomwithcabletape

    • Partslistcircuitdiagrams,controlunits–ADR......................................................... 61• Partslistcircuitdiagrams,controlunits–EasyStartT–ADR................................... 61• Circuitdiagramcontrolunits–ADR......................................................................... 62• CircuitdiagramcontrolunitEasyStartT–ADR(controlboxwith1diag.cable)....... 63• CircuitdiagramcontrolunitEasyStartT–ADR(controlboxwith2diag.cable)....... 64

    Service • Certification............................................................................................................. 65• Disposal.................................................................................................................. 65• ECDeclarationofConformity.................................................................................. 65• Representativesabroad.................................................................................... 66,67• Listofkeywords............................................................................................... 68,69• Listofabbreviations................................................................................................ 69

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 4

    Special text structure, presentation and picture symbols

    Specialtextformatsandpicturesymbolsareusedintheseinstructionstoemphasisedifferentsituationsandsubjects.Pleaserefertothefollowingexamplesfortheirmeaningsandappropriateaction.

    Special text formats and presentations• Adot(•)indicatesalist,whichisstartedbyaheading.– Ifanindenteddash(–)followsa“dot”,thislistisasub-sectionoftheblackdot.

    Picture symbols

    Danger!Thisinformationpointsoutadangeroussituationforapersonand/ortheproduct.Failuretocomplywiththeseinstructionscanresultininjuriestopeopleand/ordamagetomachinery.

    Caution!Thisinformationpointsoutadangeroussituationforapersonand/ortheproduct.Failuretocomplywiththeseinstructionscanresultininjuriestopeopleand/ordamagetomachinery.

    Important information before starting work

    Initial commissioning of the heater or functional test after a repair

    • Afterinstallingtheheater,thewholefuelsupplysystemmustbecarefullyvented:pleaserefertoandfollowthevehiclemanufacturer’sinstructions.

    • Duringtheheatertrialrun,allfuelconnectionsmustbecheckedforleaksandsecure,tightfit.

    • Iffaultsoccurwhiletheheaterisrunning,useadiagnosticunittodetermineandcorrectthecauseofthefault.

    1 IntroductionForeword

    TheseTroubleshootingandRepairInstructionsareapplicabletotheheaterslistedonthetitlePage,totheexclusionofallliabilityclaims.Dependingontheversionorrevisedstatusoftheheater,theremaybedifferencesbetweenitandthesetroubleshootingandrepairinstructions.Theusermustcheckthisbeforecarryingouttherepairworkand,ifnecessary,takethedifferencesintoaccount.

    Caution!Safety instructions for installation and repair!

    ImproperinstallationorrepairofEberspächerheaterscancauseafireorresultpoisonousexhaustenteringtheinsideofthevehicle.Thiscancauseseriousandevenfatalrisks.

    Theheatermayonlybeinstalledaccordingtothespecifica-tionsinthetechnicaldocumentsorrepairedusingoriginalsparepartsbyauthorisedandtrainedpersons.Installationandrepairsbyunauthorisedanduntrainedper-sons,repairsusingnon-originalsparepartsandwithoutthetechnicaldocumentsrequiredforinstallationandrepairaredangerousandthereforearenotpermitted.

    Arepairmayonlybecarriedoutinconnectionwiththere-spectiveunit-relatedtechnicaldescription,installationinstruc-tions,operatinginstructionsandmaintenanceinstructions.Thisdocumentmustbecarefullyreadthroughbefore/duringinstallationandrepairandfollowedthroughout.Particularattentionistobepaidtotheofficialregulations,thesafetyinstructionsandthegeneralinformation.

    Please note!

    Therelevantrulesofsoundengineeringpracticeandanyinformationprovidedbythevehiclemanufactureraretobeobservedduringtheinstallationandrepair.Eberspächerdoesnotacceptanyliabilityfordefectsanddamage,whichareduetoinstallationorrepairbyunauthor-isedanduntrainedpersons.Compliancewiththeofficialregulationsandthesafetyinstruc-tionsisprerequisiteforliabilityclaims.Failuretocomplywiththeofficialregulationsandsafetyinstructionsleadstoexclu-sionofanyliabilityoftheheatermanufacturer.

    Accident prevention

    Generalaccidentpreventionregulationsandthecorrespond-ingworkshopandoperatingsafetyinstructionsaretobeobserved.

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 5

    Cutaway view

    1 Heaterimpeller 2 Controlbox 3 Combustionairfanimpeller 4 Glowplug 5 Cover 6 Heatexchanger 7 Combinationsensor(overheating/flamesensor) 8 Radioremotecontrol(mobileunit) 9 Radioremotecontrol(stationaryunit)10 Button11 Temperaturesensor(roomtemperature)12 Fusebracketwithmainfuseand“actuation”fuse13 Electricalmotor14 Fuelconnection15 Flangeseal

    16 Combustionchamber17 Outlethood18 Combustionairhose19 Meteringpump20 Pot-typestrainer,installedinthedosingpump21 Outflow22 FlexibleexhaustpipeF= FreshairW= HotairA= ExhaustB= FuelV= Combustionair

    Functionanduse2

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 6

    Description of functions

    Switching on

    Whentheheaterisswitchedon,thecontrollampinthecon-trolunitlightsup.Theglowplugisswitchedonandthefanstartsatlowspeed.

    fthereisstilltoomuchresidualheatintheheatexchangerfromwhentheheaterwaslastused,firstlyonlythefanstartsup(coldblowing).Oncetheresidualheathasbeencleared,theheaterstarts.

    Starting Airtronic

    Afterapprox.65secondsthefuelsupplystartsandthefuel/airmixtureinthecombustionchamberignites.Oncethecombinedsensor(flamesensor)hasdetectedtheflame,theglowplugisswitchedoffafter60seconds.Theheaterisnowinstandardoperation.

    Starting Airtronic M

    Afterapprox.60secondsthefuelsupplystartsandthefuel/airmixtureinthecombustionchamberignites.Aftertheflamesensorhasdetectedtheflame,theglowplugisswitchedoffafterapprox.90sec.Theheaterisnowinstandardoperation.Afteranother120seconds,theheaterhasreachedthe“POWER”stage(maximumfuelquantity,maximumfanspeed).

    Temperature selection with the control element

    Thecontrolcanbeusedtopreselectaninteriortemperature.Theresultingtemperaturecanbewithintherangeof+10°Cto+30°Canddependsontheselectedheater,onthesizeofthespacetobeheatedandontheprevailingoutdoortem-perature.Thesettingtobeselectedatthecontrolisanempiricalvalue.

    Control in the heating mode

    Duringtheheatingmode,theroomtemperatureorthetem-peratureofthesuckedinheatingairisconstantlymeasured.Ifthetemperatureishigherthanthetemperatureselectedonthecontrolelement,theheaterstartstoregulateitsoutput.Thereare4controlstagessothattheoutflowofheatpro-ducedbytheheatercanbeadjustedfinelytotheheatingrequirements.Fanspeedandfuelquantitycorrespondtotheparticularcontrolstage.Ifthesettemperatureisstillexceededinthesmallestcontrolstage,theheatergoestothe“OFF”stagewiththefanrunningonforapprox.4minutestocooloff.Thefanthencontinuesrunningatminimumspeed(circulationmode)untiltherestartorisswitchedoff(freshairmodewithexternaltemperaturesensor).

    Ventilating mode

    TheEasyStartR+andEasyStartTcontrolunitsandthemini-controllercanbeusedtoactivatethe„Ventilate“function.The„Heat/Ventilate“switchisalsorequiredforthemodulartimerandcontroldevicewhereby,forfanmode,the„Heat/Ventilate“switchmustbepressedfirstandthentheheaterswitchedon.Theblowerrunsatmaximumspeedinfanmode.

    Switching off

    Whentheheaterisswitchedoff,thecontrollampgoesoffandthefuelsupplyisswitchedoff.Thefanrunsonforapprox.4minutestocooldown.Whilethefanisrunningon,theglowplugisswitchedonforapprox.40secondstoclean.Specialcase:Ifnofuelhasbeensuppliedoriftheheaterisinthe“OFF”stageuntilitisswitchedoff,theheaterisstoppedwithoutanyafterrunning.

    Functionanduse2

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 7

    Forced shut-down for ADR operation

    Invehiclesforthetransportofdangerousgoods(e.g.tankertrucks),theheatermustbeswitchedoffbeforethetruckdrivesintoadangerarea(refinery,petrolstation,etc.).Failuretocomplyresultsintheheaterautomaticallyswitchingoffif:• thevehicleengineisswitchedoff,• anadditionalunitisstartedup(auxiliarydriveforunloadingpump,etc.),

    • avehicledoorisopened(ADR99regulation,onlyinFrance).Thefanthenrunsonformax.40seconds.

    Functionanduse2

    Emergency shutdown – EMERGENCY OFFIfanemergencyshutdown–EMERGENCYOFF–isre-quiredduringoperation,executethefollowing:• Switchtheheateroffatthecontrolelementor• removethefuseor• disconnecttheheaterfromthebattery.

    Control and safety devices

    • Iftheheaterdoesnotignitewithin90secondsafterstartingthefuelpump,thestartisrepeated.Iftheheaterstilldoesnotigniteafteranother90secondsofpumpingfuel,theheaterisswitchedoff,i.e.thefuelsupplyisoffandthefanrunsonforapprox.4minutes.

    • Iftheflamegoesoffbyitselfduringoperation,theheaterisrestarted.Iftheheaterdoesnotignitewithin90secondsafterthefuelpumphasstarted,orignitesandgoesoffagainwithin15minutes,theheaterisswitchedoff,i.e.thefuelsupplyisoffandthefanrunsonforapprox.4minutes.Thisstatuscanberemediedbybrieflyswitchingoffandonagain.Donotrepeattheswitchingoff/onroutinemorethantwice.

    • Inthecaseofoverheating,thecombinedsensor(flamesensor/overheatingsensor)triggers,thefuelsupplyisinterruptedandtheheaterswitchedoff.Oncethecauseoftheoverheatinghasbeeneliminated,theheatercanbere-startedbyswitchingoffandonagain.

    • Iftheloweroruppervoltagelimitisreached,theheaterisswitchedoffafter20seconds.

    • Theheaterdoesnotstartupiftheglowplugorblowermo-torisdefectiveoriftheelectricleadtothemeteringpumpisinterrupted.

    • Ifthecombinedsensor(flamesensor/overheatingsensor)isdefectortheelectricleadinterrupted,theheaterstartsupandisthenswitchedoffagainduringthestartphase.

    • Thespeedofthefanmotorismonitoredcontinuously.Ifthefanmotordoesnotstartuporifthespeeddeviatesbymorethan10%,theheaterisswitchedoffafter30sec.

    •Whentheheaterisswitchedoff,theglowplugis switchedonfor40seconds(after-glowing)whilethe fanrunsontocleanoffanycombustionresidues.

    Please note!

    Donotrepeattheswitchingoff/onroutinemorethantwice.

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 8

    Technichaldata3

    Providednolimitvaluesaregiven,thetechnicaldatalistedissubjecttothetolerancesusuallyapplicabletoheatersof±10%fornominalvoltage,ambienttemperature20°CandreferencealtitudeEsslingen.

    Caution!Safety instructions for technical data!Failuretocomplywiththetechnicaldatacanresultinmalfunc-tions.

    Technichal data

    Heatertype

    Heater

    Version

    Heatingmedium

    Controloftheheatflow

    Heatflow(watt)

    Heaterairflowratewithoutcounterpressure(kg/h) withhoodØ60mm

    Fuelconsumption(l/h)

    Elektr.powerconsumption(watt)

    inoperation(12and24volt)

    atstart(12and24volt)

    Ratedvoltage

    Operatingrange Lowervoltagelimit:Anundervoltageprotectioninthecontrollerswitchesofftheheaterwhenthevoltagelimitisreached.

    Uppervoltagelimit: Anuppervoltageprotectioninthecontrollerswitchesofftheheaterwhenthevoltagelimitisreached.

    Fuel

    Tolarableambienttemperature

    Heater

    Dosingpump

    Maximumairintaketemperature

    Interferencesuppression

    Weight

    Ventilationmode

    Airtronic

    AirtronicD2/AirtronicD2Camper

    D2/D2Camper

    Air

    Stage

    Power Large Medium Small Off

    2200 1800 1200 850 –

    105 90 60 40 13

    0.28 0.23 0.15 0.10 –

    34 22 12 8 5

    #100

    12or24volt

    approx.10.5voltresp.21voltUndervoltageprotectiontriggertime:20seconds

    approx.16voltresp.32voltOvervoltageprotectiontriggertime:20seconds

    DieselDINEN590(commerciallyavailable)

    inoperation nooperation

    –40°Cto+70°C –40°Cto+85°C

    –40°Cto+50°C –40°Cto+125°C

    max.+40°C

    Interferencesuppressionclass5toDINEN55025

    approx.2.7kg

    possible

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 9

    Technichaldata3Technichal data

    Heatertype

    Heater

    Version

    Heatingmedium

    Controloftheheatflow

    Heatflow(watt)

    Heaterairflowratewithoutcounterpressure(kg/h) withhoodØ90mm

    Fuelconsumption(l/h)

    Elektr.powerconsumption(watt)

    inoperation(12and24volt)

    atstart(12and24volt)

    Ratedvoltage

    Operatingrange Lowervoltagelimit:Anundervoltageprotectioninthecontrollerswitchesofftheheaterwhenthevoltagelimitisreached.

    Uppervoltagelimit: Anuppervoltageprotectioninthecontrollerswitchesofftheheaterwhenthevoltagelimitisreached.

    Fuel

    Tolarableambienttemperature

    Heater

    Dosingpump

    Maximumairintaketemperature

    Interferencesuppression

    Weight

    Ventilationmode

    Airtronic M

    AirtronicB4

    B4

    Air

    Stage

    Power Large Medium Small Off

    3800 3200 2100 1300 –

    185 160 120 85 24

    0.54 0.46 0.29 0.18 –

    40 29 15 9 5

    #100

    12volt

    approx.10.5voltUndervoltageprotectiontriggertime:20seconds

    16voltOvervoltageprotectiontriggertime:20seconds

    PetrolDINEN228(commerciallyavailable)

    inoperation nooperation

    –40°Cto+50°C –40°Cto+85°C

    –40°Cto+20°C –40°Cto+125°C

    max.+40°C

    Interferencesuppressionclass5toDINEN55025

    ca.4.5kg

    possible

    Providednolimitvaluesaregiven,thetechnicaldatalistedissubjecttothetolerancesusuallyapplicabletoheatersof±10%fornominalvoltage,ambienttemperature20°CandreferencealtitudeEsslingen.

    Caution!Safety instructions for technical data!Failuretocomplywiththetechnicaldatacanresultinmalfunc-tions.

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 10

    Technichaldata3Technichal data

    Heatertype

    Heater

    Version

    Heatingmedium

    Controloftheheatflow

    Heatflow(watt) D3

    D4

    D4Plus

    Heaterairflowratewithoutcounterpressure(kg/h) D3withhoodØ90mm

    D4withhoodØ90mm

    D4PluswithhoodØ75mm

    Fuelconsumption(l/h) D3

    D4

    D4Plus

    Elektr.powerconsumption(watt) D3

    inoperation(12and24volt) D4

    D4Plus

    atstart(12and24volt)

    Ratedvoltage

    Operatingrange Lowervoltagelimit:Anundervoltageprotectioninthecontrollerswitchesofftheheaterwhenthevoltagelimitisreached.

    Uppervoltagelimit: Anuppervoltageprotectioninthecontrollerswitchesofftheheaterwhenthevoltagelimitisreached.

    Fuel

    Tolarableambienttemperature

    Heater

    Dosingpump

    Maximumairintaketemperature

    Interferencesuppression

    Weight

    Ventilationmode

    Airtronic M

    AirtronicD3/AirtronicD4/AirtronicD4Plus

    D3/D4/D4Plus

    Air

    Stage

    Power Large Medium Small Off

    3000 2200 1600 900 –

    4000 3000 2000 900 –

    4000 3000 2000 900 –

    150 120 90 60 24

    185 150 110 60 24

    175 140 100 55 22

    0.38 0.28 0.2 0.11 –

    0.51 0.38 0.25 0.11 –

    0.51 0.38 0.25 0.11 –

    24 16 10 7 5

    40 24 13 7 5

    55 30 16 7 5

    #100

    12or24volt

    approx.10.5voltresp.21voltUndervoltageprotectiontriggertime:20seconds

    approx.16voltresp.32voltOvervoltageprotectiontriggertime:20seconds

    DieselDINEN590(commerciallyavailable)

    inoperation nooperation

    –40°Cto+70°C –40°Cto+85°C

    –40°Cto+50°C –40°Cto+125°C

    max.+40°C

    Interferencesuppressionclass5toDINEN55025

    approx.4.5kg

    possible

    Providednolimitvaluesaregiven,thetechnicaldatalistedissubjecttothetolerancesusuallyapplicabletoheatersof±10%fornominalvoltage,ambienttemperature20°CandreferencealtitudeEsslingen.

    Caution!Safety instructions for technical data!Failuretocomplywiththetechnicaldatacanresultinmalfunc-tions.

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 11

    Technichaldata3Technichal data

    Heatertype

    Heater

    Version

    Heatingmedium

    Controloftheheatflow

    Heatflow(watt) D4S

    D4Camper/D4CamperPlus

    Heaterairflowratewithoutcounterpressure(kg/h) D4S

    D4Camper/D4CamperPlus

    Fuelconsumption(l/h)) D4S

    D4Camper/D4CamperPlus

    Elektr.powerconsumption(watt) D4S

    inoperation(12and24v) D4Camper/D4CamperPlus

    atstart(12and24v)

    Ratedvoltage

    Operatingrange Lowervoltagelimit:Anundervoltageprotectioninthecontrollerswitchesofftheheaterwhenthevoltagelimitisreached.

    Uppervoltagelimit: Anuppervoltageprotectioninthecontrollerswitchesofftheheaterwhenthevoltagelimitisreached.

    Fuel

    Tolarableambienttemperature

    Heater

    Dosingpump

    Maximumairintaketemperature

    Interferencesuppression

    Weight

    Ventilationmode

    Airtronic M

    AirtronicD4S/Airtronic D4Camper/AirtronicD4CamperPlus

    D4S/D4Camper/D4CamperPlus

    Air

    Stage

    Power Large Medium Small Off

    3500 3000 2000 1000 –

    4000/3500 3000 2000 900 –

    160 140 100 60 22

    185/160 150/140 110/100 60/55 24/22

    0.44 0.38 0.25 0.13 –

    0.51/0.44 0.38 0.25 0.11 –

    40 30 16 8 5

    40 24/30 13/16 7/8 5

    #100

    12or24volt

    approx.10.5voltresp.21voltUndervoltageprotectiontriggertime:20seconds

    approx.16voltresp.32voltOvervoltageprotectiontriggertime:20seconds

    DieselDINEN590(commerciallyavailable)

    inoperation nooperation

    –40°Cto+70°C –40°Cto+85°C

    –40°Cto+50°C –40°Cto+125°C

    max.+40°C

    Interferencesuppressionclass5toDINEN55025

    approx.4.5kg

    possible

    Providednolimitvaluesaregiven,thetechnicaldatalistedissubjecttothetolerancesusuallyapplicabletoheatersof±10%fornominalvoltage,ambienttemperature20°CandreferencealtitudeEsslingen.

    Caution!Safety instructions for technical data!Failuretocomplywiththetechnicaldatacanresultinmalfunc-tions.

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 12

    Check values

    Test speed for the blower

    Airtronic D2 / D2 Camper(12volt/24volt)• 12volt 5000rpm±25% atU=10,0volt• 24volt 5000rpm±25% atU=18,0volt

    AirtronicB4 (12volt)AirtronicD3 / D3 Camper(12volt)AirtronicD4(12volt/24volt)AirtronicD4 Camper(12volt)• 12volt 4400rpm±25% atU=10,0volt• 24volt 4400rpm±25% atU=18,5volt

    AirtronicD4S/Airtronic D4 Plus (12volt/24volt)AirtronicD4 Camper Plus (12volt)• 12volt 4400rpm±25% atU=10,5volt• 24volt 4400rpm±25% atU=19,0volt

    Resistance values at 20 °C

    12 volt 24 volt

    Glowplug 0.42 –0.70 1.2 –2.0Dosingpump 9.5±0.50 36.0±1.8

    Control unit resistance values

    Switch position, left limit stop

    Switch position, right limit stop

    Controldevice12volt/24volt

    min.1720max.1760

    min.2096max.2216

    Modulartimerandmini-controller12volt/24volt

    min.1730max.1780

    min.2120max.2240

    Switching value Overheatingsensor 140°C–170°C measuredinthe“High”controlstage andatadistanceof300mmdownstream fromthehotairoutletExhaust emission specificationCO2 in exhaustincontrolstage“high” 7,5–12,5Vol.%SmokespotnumberaccordingtoBacharach <4

    Temperature (°C)

    Res

    ista

    nce

    (ohm

    )

    2200

    2000

    1800

    1600

    1400

    1200

    1000±40 ±20 0 20 40±10±30 10 30

    2400

    50

    Technicaldata3

    Check “external” temperature sensor(OrderNo.:251774890300)The“external”temperaturesensortestmustbecarriedoutusingadigitalmultimeter.Iftheresistancevalueisnotthesameasthecurveinthediagramorthetableofvalues,re-placethetemperaturesensor.

    Table of values – “external” temperature sensor

    Temperature°C Resistance

    min. max.0 1600 16605 1670 173010 1745 180015 1820 187020 1895 195025 1970 203030 2050 211035 2130 219040 2210 228045 2295 2370

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 13

    Troubleshooting4What to check first in case of faults

    • Check– Fuelinthetank?– Fuelpipesleaking?(visualcheck)– Summerdieselinthefuelpipe?– Combustionairsystemorexhaustsystemdamagedorblocked?

    – Hotairsystemblocked?– Airpressuresensorinstalled?Ifyes,referto„Whattodoif…?“chapterofthe„AltitudeKit“installationinstructions.

    – Newgenerationcontrolboxinstalled? Features: >Cableloomofcontrolboxwoundwithcabletie >Temperaturesensormountedonthesideofthecontrol

    box(visiblewhencoverremoved)

    • Electrical components– Cables,connectionsdamaged?– Contactscorroded?– Fusesdefective?– Incorrectwiring?(shortcircuits,interrupted/broken)

    • Measure battery voltage– Batteryvoltage<10.5volt,theundervoltageprotectionofthe12voltheaterhastriggered.

    – Batteryvoltage<21volt,theun

    • Measure voltage supply (Cl 30) Disconnectthe16-pinconnectorS1/B1andmeasurethevoltageappliedatconnectorB1betweenchamber1(cable2.52rt)andchamber10(cable2.52br).

    Ifitdiffersfromthebatteryvoltage,checkthefuses,thesupplycables,thenegativeconnectionandthepositivesupportpointonthebatteryforvoltagedrop(corrosion/interruption).

    • Check switch-on signal Disconnectthe16-pinconnectorS1/B1andthenswitchontheheateratthecontrolunit.

    CheckwhethervoltageisappliedintheconnectorB1betweenchamber4(cable0.52ge)andchamber10(cable2.52br).

    Ifnovoltageismeasured,thencheckthesupplycable(ca-ble0.52ge),the5Afuse(item2.7.1inthecircuitdiagram)andthecontrolunit.

    • Check control unit

    Control device, mini-timer, mini-controller and modular timer

    Disconnecttheconnectoratthecontrolunit;installajumperbetweenthered0.5²rtcableandtheyellow0.5²gecable.

    IfavoltageismeasuredinconnectorB1betweencham-ber4(cable0.5²ge)andchamber10(cable2.5²br),thenreplacethecontrolunit.

    EasyStart R+ / EasyStart R / EasyStart T Disconnecttheconnectoratthecontrolunit;installajumperbetweentheblack/white0.5²bl/wscableandthered0.5²rtcable.

    IfavoltageismeasuredinconnectorB1betweenchamber8(cable0.5²bl/ws)andchamber10(cable2.5²br),thenreplacethecontrolunit.

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 14

    Troubleshooting4Overview of the test equipment and control units suitable for diagnosis

    Theelectroniccontrolboxcanstoreupto5faults,whichcanbereadoutanddisplayed.Thefollowingtestequipmentand/orcontrolunitscanbeusedtoquerythefaultmemoryinthecontrolboxandifnecessarytodeletethelockingofthecontrolbox:

    Test equipment Order No.:

    • Testingdevice forthecontroldevice 221509890000

    • Diagnosticunit 221529890000 additionallyrequired: Adaptercable 221000318600

    • EDiTHdiagnostictool – Basicadapterwithsoftware 221542890000 additionallyrequired: Airtronicextension 221537890000

    – ISO-adapter 221541890000 additionallyrequired: Adaptercable 221000318600

    – „Airpressuresensor“adaptercable221000333100 Onlyforheaterswithconnectedairpressuresensorfor

    readingoutthe„airpressuresensor“faultmemory.

    Ifadiagnosticscableisconnected,thefollowingcontrolunitscanalsobeused:

    Control units Order No.:

    •Moduletimer 221000303400

    • TP5radioremotecontrol 221000320100

    • EasyStartT 221000328800

    • EasyStartR+ 221000328000

    Please note!

    Ifthefaultmemorycannotbereadout,checkthediagnosticscableforcorrectlayingandpossibledamage.

    Important notes on diagnosis of heaters with mini-controller control unit

    Caution!WhencheckingtheheaterwiththediagnosticsunitortheEDiTHdiagnosticstooltheordergiveninthefollowingnotesmustalwaysbefollowedasotherwisetheheaterdetectsError62(controlunit–interruption)andswitchestoemergencyoperation.

    Mini-controller in stand-alone operation

    • Connectadaptercable221000318600asdescribedintheoperatinginstruction.

    • Selectoperatingmode(Heat/Ventilate)atthemini-control-ler

    • PerformdiagnosisusingthediagnosticsunitortheEDiTHdiagnosticstool.

    • Switchoffthemini-controllerafterfinishingthediagnosis• Removetheadaptercable

    Mini-controller in combination with mini-timer

    • Connectadaptercable221000318600asdescribedintheoperatinginstruction.

    • Pressthembuttonofthemini-timer• Selectoperatingmode(seemini-timeroperatinginstruc-tions)

    • PerformdiagnosisusingthediagnosticsunitortheEDiTHdiagnosticstool.

    • Switchoffthemini-timerafterfinishingthediagnosis• Removetheadaptercable

    Mini-controller in combination with TP5

    • Connectadaptercable221000318600asdescribedintheoperatinginstruction.

    • Pressthe buttonoftheTP5radioremotecontrol• Selectoperatingmode(seeTP5radioremotecontroloper-atinginstruction)

    • Performdiagnosis.• SwitchoffTP5radioremotecontrolafterfinishingthediag-nosis

    • Removetheadaptercable

    Please note!

    IftheoperatingmodeistobechangedduringthetesttheheatermustbeswitchedofffirstusingthediagnosticsunitortheEDiTHdiagnosticstool,otherwisetheheaterdetectsError62(controlunit–interruption)andswitchestoemergencyoperation.

    Test mini controller

    Themini-controllermustbeconnectedtotheheaterfortest-ing.ThesetpointvaluecanbedisplayedusingtheEDiTHdiagnosticstool.Iftherotaryknobisattheleftlimitstopthesetpointvalueis8°C,attherightlimitstopitis34°C.

    Please note!

    Theresistanceofthesetpointvaluepotentiometercannotbemeasureddirectly.Themeasuredvaluesarenotmeaningful.

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 15

    Troubleshooting4Testing device for the control device(OrderNo.:221509890000)

    Prepare for testConnectthecorrectoperatingvoltage(12or24volt)tothete-stingdevice,withplusattheredconnectorsocketandminusattheblueconnectorsocket.

    • Disconnectsocketfromthecontrolunit.• Connectcableloomfromtestingdevicewiththecontrolunit.

    • Settherotaryknobofthecontrolunitto“Heat”,thecorre-spondingredLEDinthetestingdevicemustlightup.

    • Setcontrolunitto“0”,thenpressthe“LED–red”button,theredcontrollampinthecontrolunitmustlightup.

    • Setcontrolunitto“Heat”,thenpressthe“LED–green”button,correspondingredcontrollampinthetestingdeviceandthegreencontrollampinthecontrolunitmustlightup.

    Caution!Safety instructions for checking the control unit!Ensureyouusethecorrectoperatingvoltage,otherwisetheconnectedcomponentscanbeseverelydamaged.

    Check the setpoint potentiometer of the control unitSetthe“Temperaturesensor/Potentiometer”switchinthetestingdevicetothe“Potentiometer”settingandslowlyturntherotaryknobofthecontrolunit.ThegreenLED–temperaturesensor/potentiometermustlightupcontinuously.Incaseofafault,replacethecontrolunit.

    1 Testingdevice2 Controldevice

    Diagnostic unit(OrderNo.:221529890000)

    Anadditionaladaptercableisrequiredtoconnectthediag-nosticunit(OrderNo.:221000318600).

    Thecurrentfaultisdisplayedas“AF”anda2-digitnumberandisalwayswritteninthememorypositionF1.PrecedingfaultsaremovedtothememorylocationsF2–F5,ifnecessarythecontentsofmemorypositionF5isoverwrit-ten.

    • Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.

    • Inheaterswithconnectedairpressuresensorthediagnos-ticsunitcanbeusedtoreadoutthefaultmemoryoftheheateronly.

    Thefaultmemoryofthe„airpressuresensor“canbereadoutusingtheEDiTHdiagnosticstoolonly.

    • Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.

    l–Deletefaultmemoryl–Deletefaultmemoryd–Switchheateron/off,requestdiagnosise–Reverse,F5–F1f–Forward,F1–F5,currentfault(AF)

    Connectdiagnosticsunit,seepage16.

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 16

    Connect diagnostic unit• Disconnectthe8-pinconnectoroftheheater’scablehar-nessandconnecttheadaptercable.

    • Connectthediagnosticunittotheadaptercable. Displayisasfollows:

    Query fault memory• UsetheDkeytoswitchontheheater. Displayisasfollows:

    • After8secthefollowingisdisplayed: Displayisasfollows:

    Heaterhasnomalfunction or

    e.g.currenterror/faultcode64

    or

    Faultdiagnosisnotpossible

    Possiblecauses: – Adaptercableisnotproperlyconnected. – Controlboxisdefectiveorisnotcapableofdiagnosing

    (notauniversalcontrolbox).

    Display of the fault memory F1 – F5 or F5 – F1• Presstheeorfbutton,orpressseveraltimes,todisplaythefaultmemory.

    Displayisasfollows:

    e.g.faultmemory2/faultcode10

    Onlythefaultmemorypositionswithanerrorassignedtothemaredisplayed.

    Delete fault memory• PressbothLbuttonssimultaneouslyuntilthefollowingap-pearsinthedisplay:

    Displayisasfollows:

    • Ifthefaultmemoryhasbeendeletedthemostrecentcur-rentfaultisdisplayed.Thecurrentfaultisnotresetto00untiltheheaterisrestarted–providedthereisnonew,morerecentfault.

    Displayisasfollows:

    Heaterhasnomalfunction

    Cancel the control box lock• Deletethefaultmemoryasdescribedandswitchofftheheaterusingthedkey.

    • Thecontrolboxlockiscancelledandthediagnosisclosed. Displayisasfollows:

    Troubleshooting4

    1 Heater2 Adaptercable3 Diagnosticunit

    1

    2

    3

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 17

    Troubleshooting4EDiTH diagnostic tool with ISO adapter(OrderNo.:221541890000)

    AnadditionaladaptercableisrequiredtoconnecttheISOadapter(OrderNo.:221000318600).

    • Itisveryimportanttoalwaysinstallinthegivenorder.• Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.

    • Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.

    • TheEDiTHdiagnosticstoolscopeofsupplydoesnotincludethesoftware;thismustbedownloadedfromtheServicePortal.

    Connect ISO adapter

    • Disconnecttheheater’scableharness.• Connecttheadaptercabletothecableharness–asshowninthesketch.

    • ConnecttheadaptercabletotheISOadapter.• ConnecttheSUB-DconnectioncablewiththePCandthe ISOadapter.

    Installing the software on your PC• Doubleclickthe“setup.exe”filetostarttheinstallationandfollowingtheSETUPprograminstructions.

    Query / delete fault memory F1 – F5 or cancel the control box lock• StartthesoftwareonyourPC: – onthedesktop—>doubleclickthe“EDiTH”icon – Selectheatertype – Pressthe“GO”button.

    • Deletefaultmemoryorcancelthecontrolboxlock: – pressthe“Deletefaultmemory”button —>thestoredfaultsF1–F5aredeletedandthecontrol

    boxisunlocked.

    Quit diagnosis• Pressthe“STOP”button—>faultmemoryqueryisended.

    1 Heater2 Adaptercable3 ISOadapter

    4 SUB-Dconnectioncable5 USBtoSerialRS-232adapter

    e

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 18

    Troubleshooting4Air pressure sensor diagnosis using EDiTH diagnostics tool and ISO adapter(OrderNo.221524890000)

    AnadditionaladaptercableisrequiredtoconnecttheISOadapter(OrderNo.:221000333100).

    Theairpressuresensorconnectedtotheheatercanbediag-nosed.Iffaultsoccurduringthealtitudeadjustmenttheyarestoredintheairpressuresensor.Ifnecessary,faultscanbereadoutusingtheISOadapterinconjunctionwiththeEDiTHdiagnosticstool–fromVersionS3V7-F–andtheadditionallynecessaryadaptercable.

    Please note!

    • Itisveryimportanttoalwaysinstallinthegivenorder.• Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.

    • Faultcode,faultdescription,cause/remedialactionaredescribedonpages27.

    • TheEDiTHdiagnosticstoolscopeofsupplydoesnotincludethesoftware;thismustbedownloadedfromtheServicePortal.

    Perform diagnosis of the air pressure sensor

    Disconnecttheconnectorbetweentheairpressuresensor/heater,controlunit,connecttheISOadapterwiththeadaptercable(seesketch).Startthediagnosisoftheairpressuresensor.

    • Double-clickthe>>EDiTH

  • 19

    Caution! Magnetic field!Duringthetestoperationamagneticfielddevelopsattheadapter.Therefore,donotplaceanyobjectssuchasdatamedia,creditcards,etc.ontheadapterorinitsimmediatevicinity.

    Troubleshooting4

    (A) Basicadapter(B) SUB-Dconnectioncable(C) Mainsconnection(D) Mainsswitch(E) USBtoSerialRS-232adapter(F) Adapter(G) Controlbox

    Cable colourssw = blackgn = greenbl = blue

    EDiTH diagnostic tool with basic adapterEDiTHbasicadapter(OrderNo.:221542890000)

    Anadditionalextensionisrequiredtocheckthecontrolbox(OrderNo.:221537890000).

    • Itisimportanttoalwaysfollowthepreciseconnectionorderasgivenbelow!

    • TheHallsensorintegratedinthecontrolboxcanonlybeproperlytestedinthecontrolboxiscorrectlyplacedontheextension.

    • Onlypushorpullontheconnectors,notonthecables!• OnlyusethenetworkcableandRS232cablewithsnapferritesincludedinthescopeofsupply.Useoriginalacces-sorieswithsnapferritesonlytoconnectthetestequipment.

    • Notonlythedefectivecomponent,butalsoadefectivecurrentcircuitresultsinafaultbeingdisplayed.

    • Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.

    Connect basic adapter• Startcomputerandwaituntilthesystemhassuccessfullybooted.

    • StartPCsoftware.• Inserttheunitconnectorofthemainscableinthebasicadapter(A)andconnectthemainsconnection(C)tothemains.

    • ConnecttheSUB-Dconnectioncable(B)withthePCandbasicadapter(A).

    Connect extension and test control box• Connecttheextensiontothebasicadapter(A).• Connectthecontrolbox(E)totheextensionandtheadap-ter(F).

    • Switchonthebasicadapter(A)atthemainsswitch(D).• Selectthecontrolboxversionandoperatingvoltage(12V/24V)inthePCsoftware.

    • StartthecontrolboxtestwiththePCsoftware.Amorede-taileddescriptionofhowtooperatethebasicadapters(A)isgivenintheEDiTHonlinehelp.

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 20

    Troubleshooting4Module timer(OrderNo.:221000303400)

    Thecurrentfaultisdisplayedas“AF”andisalwayswritteninmemorypositionF1.PrecedingfaultsaremovedtothememorylocationsF2–F5,ifnecessarythecontentsofmemorypositionF5isoverwrit-ten.

    • Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.

    • Inheaterswithconnectedairpressuresensorthemodulartimercannotbeusedtoperformdiagnoses.Thediagnos-ticsunitortheEDiTHdiagnosticstoolmustbeusedtoperformthediagnosis.

    Thefaultmemoryofthe„airpressuresensor“canbereadoutusingtheEDiTHdiagnosticstoolonly.

    • Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.

    Query fault memory F1 – F5 Condition:Theheaterisswitchedoff.

    • Pressckey–>theheaterisswitchedon.

    • Pressakeyandkeeppressed, thenpresspkeywithin2seconds. Displayisasfollows: AF=currentfault 3digitnumber=faultcode cflashes.

    • Pressfkeyonceorseveraltimes,faultmemorypositionsF1–F5aredisplayed.

    Cancel the control box lock and simultaneously delete the fault memoryCondition:Anelectricalconnectionexistsfromterminal15(ignition)tothemoduletimer,12-pinconnector,chamber10.

    • Pressckey Displayisasfollows: thecurrentfaultF15orF50.

    • Pressbuttona,keepitdepressedandthenpressbuttonpwithin2seconds.

    Themoduletimerisnowinthe“Queryfaultmemory”pro-gram.

    • Switchoffignition(terminal15).

    • Simultaneouslypressbuttonaandbuttonp,inaddition,switchontheignition(terminal15)andwaituntilthefollow-ingappearsinthedisplay.

    Afterignition“ON”thefollowingappearsinthedisplay:

    Displayflashes, Heatersymboldoesnotflash

    • Switchtheheateroffandon–>thecontrolboxisunlocked,theheaterrestarts.

    Afterswitchingtheheateroffandonandrenewedqueryofthefaultmemory,thefollowingappearsinthedisplay:

    Displayflashes, Heatersymboldoesnotflash

    a–Timep–Presetc–Heate–Reversef–Forward

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 21

    Troubleshooting4TP5 radio remote control(OrderNo:221000320100)

    Iffaultsoccurwhiletheheaterisrunning,theyaredisplayedwith“Err”afterthemobileunitisactivated.

    Afterthediagnosticscable(bl/ws)hasbeenconnectedandthefirstlogshavearrivedatthestationaryunit,thediagnosecanbecarriedoutusingthemobileunitoftheTP5radioremotecontrol.Thecurrentfault“F0”isdisplayed.Thestoredfaults“F1”to“F5”canbequeried.

    • Inordertocarryoutthediagnosis,thediagnosticscable(bl/ws)mustbeconnectedtothestationaryunitandtheheatercableharness.Tothisend,pleaserefertoandfollowthecircuitdiagramfortheTP5radioremotecontrolandtheheater.

    • Ifthediagnosticscable(bl/ws)isnotconnected,the“Diag-nosis”menuisblocked.

    • Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.

    • InheaterswithconnectedairpressuresensortheTP5radioremotecontrolcannotbeusedtoperformdiagnoses.ThediagnosticsunitortheEDiTHdiagnosticstoolmustbeusedtoperformthediagnosis.

    Thefaultmemoryofthe„airpressuresensor“canbereadoutusingtheEDiTHdiagnosticstoolonly.

    • Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.

    Buttontoactivate/deactivatethemobileunit

    Buttonforforwardtimesetting

    Buttonforbackwardtimesetting

    Buttonforactivatingthepossiblesettings

    Buttonforswitchingheat/ventilateON/OFF; Activate/deactivatepreselectedtime

    Enquire / delete fault memoryUsethe keytoactivatethemobileunit.Switchontheheaterwiththe key.Pressthe keytwicetoopentheTimesettingmenu–thetimeflashesinthedisplay.

    Pressthe keyforapprox2sec–untilthefollowingap-pearsinthedisplay:

    Press key.Press key.Press keytwice.Press key.

    Malfunctioninheater: Heaterhasnomalfunction:

    Usethe and buttonstocallupthefaultmemoryposi-tions1to5.

    Delete fault memory / Cancel the control box lockUsethe keytodeletethefaultmemory.

    Toconfirm,pressthe keyforapprox2secuntil lightsupinthedisplay–faultmemoryisdeleted.

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 22

    The following actions are possible• Callupfaultmemory. CallupthefaultmemorypositionsF1–F5with or .

    • Callupfaultmemoryagain. Brieflypress and simultaneously.

    • Deletefaultmemory (displaydEL) Press .

    Press again.

    The diagnosis is completed.

    Switch off heater.

    Enquire / delete fault memoryActivatemobilepart/timer(seeEasyStartR+/EasyStartToperatinginstructions)

    Confirmsymbol with .

    Heater is switched on.

    Confirmoperatingtimewith .

    Brieflypress and simultaneously.

    Troubleshooting4EasyStart R+ radio remote control(Order-No.:221000328000)

    EasyStart T timer(Order-No.:221000328800)

    Iffaultsoccurwhiletheheaterisrunning,theyaredisplayedwith“Err”afterthemobileunitortimerisactivated.

    Thecurrentfaultisdisplayed.Thestoredfaults“F1”to“F5”canbequeried.

    • Inordertocarryoutthediagnosis,thediagnosticscable(bl/geatheaterconnector,bl/wsatcableharnessconnector)mustbeconnectedtothestationaryunitandtheheatercableharness.Tothisend,pleaserefertoandfollowthecircuitdiagramfortheradioremotecontrolandtheheater.

    • Ifthediagnosticscableisnotconnected,the“Diagnosis”menuisblocked.

    • Notonlythedefectivecomponent,butalsoadefectivecur-rentcircuitresultsinafaultbeingdisplayed.

    • Theheaterdiagnosiscanalsobeperformediftheairpres-suresensorisconnected.

    Thefaultmemoryofthe„airpressuresensor“canbereadoutusingtheEDiTHdiagnosticstoolonly.

    • Faultcode,faultdescription,cause/remedialactionaredescribedonPages23–27.

    Backcontrolkey

    Nextcontrolkey

    ON/OFFactivationkeymobileunit/timer

    OKkey(symbolselection/confirminput)

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 23

    Troubleshooting4Fault codeDisplay

    Fault description Comments• Remedial action

    000 Nofaults ——

    004 Warning:Shortcircuitincontrolbox,freshairoutput

    • DisconnectconnectorS1/B1attheheaterandattheconnectorB1,PIN16checkthecableuptothefreshairfanrelayforshortcircuittonegative,ifok—>replacecontrolbox.

    005 Warning:Shortcircuitincontrolbox,caralarmoutput

    • DisconnectconnectorS1/B1attheheaterandattheconnectorB1,PIN15checkthecableuptotherelayisolatingswitchorburglaralarmsysteminputforshortcircuittonegative,ifok—>replacecontrolbox.

    006 Warning:Inexplicableatmosphericaltitudeinformation(Displayonlyifheaterslabelled“H-Kit”onthenameplate.)

    Controlboxhasnotreceivedanyexplicablealtitudeinformation.• ReadoutfaultmemoryintheairpressuresensorusingtheEDiTHdiagnos-ticstoolandcorrectfault.

    009 Cut-offADR ADRshutdownduetosignalchangefrom(+)to(–)atconnectorS1,PIN13(D+)orplussignalatconnectorS1,PIN14(HA+).

    010 Overvoltage–cut-off Overvoltageappliedtocontrolboxforatleast20secondswithoutinterruption–heaternotworking.• DisconnectconnectorS1/B1attheheater,startthevehicle’sengine,measurethevoltageatconnectorB1betweenPIN1(cable2.52rt)andPIN10(cable2.52br).

    Airtronic12volt–voltage>16volt—>checkgeneratorregulator Airtronic24volt–voltage>32volt—>checkgeneratorregulator

    011 Undervoltage–cut-off Undervoltageappliedtocontrolboxforatleast20secondswithoutinterrup-tion–heaternotworking.• DisconnectconnectorS1/B1attheheater,thevehicle’sengineisswitchedoff,measurethevoltageatconnectorB1betweenPIN1(cable2.52rt)andPIN10(cable2.52br).

    Themeasuredvalueandthevoltageatthebatteryshouldbethesame. Incaseofavoltagedrop,checkthefuses,thesupplycables,thenegativeconnectionsandthepositivesupportpointonthebatteryforcorrosionandcorrectcontact.

    012 Overheatingattheoverheatingsensor Temperatureoftheoverheatingsensortoohigh.• Checkhotairpipesforblockage—>removeblockage.• Sumofthecomponentratingsofair-conductingpartsistoolarge—>Checkairsystem,ifnecessaryre-lay–forcomponentratings,pleaserefertoadditionalpartscatalogue.

    • Checkoverheatingsensor,fordiagramandtableofvaluespleaserefertoPage32,ifok—>measurefuelquantity,seePage36.

    013 Overheatingattheflamesensor Flamesensorsignalstemperatureatheatexchangeristoohigh.• Checkhotairpipesforblockage—>removeblockage.• Sumofthecomponentratingsofair-conductingpartsistoolarge—>Checkairsystem,ifnecessaryre-lay–forcomponentratings,pleaserefertoadditionalpartscatalogue.

    • Checkflamesensor,ifok—>checkoverheatingsensor,ifoverheatingsensordefective—>replacecombinationsensor,ifoverheatingsensorok—>measurefuelquantity,seePage36,fordiagramandtableofvaluesforflamesensorandoverheatingsensorpleaserefertoPage32.

    014 Temperaturedifferencebetweenflamesensorandoverheatingsensortoolarge

    Temperaturedifferencebetweenflamesensorandoverheatingsensortoolarge• Checkhotairpipesforblockage—>removeblockage.• Sumofthecomponentratingsofair-conductingpartsistoolarge—>Checkairsystem,ifnecessaryre-lay–forcomponentratings,pleaserefertoadditionalpartscatalogue.

    • Checkflamesensor,ifok—>checkoverheatingsensor,ifoverheatingsen-sordefective—>replacecombinationsensor,ifoverheatingsensorok—>measurefuelquantity,seePage36,iffuelquantityok—>replacecontrolbox.Fordiagramandtableofvaluesforflamesensorandoverheatingsen-sor,seePage32.

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 24

    Troubleshooting4Fault codeDisplay

    Fault description Comments• Remedial action

    015 Operatinglock-out Thefaultcode015isdisplayed,iftheheaterwasswitchedbackonafterthefaultcodedisplay017.

    Thehardwarethresholdvaluefortheoverheatingsensorhasbeenexceeded—>thecontrolboxislocked.

    • Replacecontrolbox.

    017 Overheating Thehardwarethresholdvaluefortheoverheatingsensorhasbeenexceeded,becausethecontrolboxfailedtorecognisethefaultcode012or013–>thecontrolboxislocked.Iftheheaterisswitchedonagain,thefaultcode015isdisplayed.• Replacecontrolbox.

    018 Startingenergyoftheglowplugistoolow(Displayonlyifheaterslabelled“H-Kit”onthenameplate.)

    • Checkglowplug(seefaultcode020and021),ifok• Checkglowplugcableharnessforcorrectlayinganddamage,ifok—>checkcableharnessforcontinuity,ifok—>replacecontrolbox.

    019 Ignitionenergytoolow •Checkglowplug(seefaultcode020and021),ifok• Checkglowplugcableharnessforcorrectlayinganddamage,ifok—>checkcableharnessforcontinuity,ifok—>replacecontrolbox.

    020

    021

    Glowplug–interruption

    Glowplug–shortcircuit,overloadorshortcircuitafternegative

    • Checkglowplugforfunctionandcontinuityatambienttemperature20°C. 12voltheater–0.42upto±0.7 24voltheater–1.2upto±2.0

    • Ifthevaluesareok—>checkglowplugleadharnessfordamageandcon-tinuity,ifok—>replacecontrolbox.

    022 * Glowplug,output(+)–shortcircuitafterUB(batteryvoltage)

    • Checkglowplugleadharnessforcorrectlayinganddamage,ifok—>checkleadharnessforcontinuity,ifok—>replacecontrolbox.

    025 * Diagnosticscablebl/ws–shortcircuit–afterUB(batteryvoltage)

    Faultcodedisplayisnotpossible.Thisfaultcodecannotbereadoutfromthefaultmemoryuntilthefaulthasbeencorrected.• Checkdiagnosticscableforcorrectlayingandpossibledamage.

    031 Blower–interruption • Checkthattheleadharnessoftheblowermotorhasbeencorrectlylaidandcheckfordamage,ifok—>removeleadharnessatcontrolboxandcheckforcontinuity,ifok—>replacecontrolbox.

    032 Blowermotor–shortcircuitafternegative

    Please note!

    Ensurecompliancewiththetestvolt-age(seepage12).Thecomponentisdestroyedifthevoltagevalueisexceeded.Ensure the power pack has ad-equate short-circuit resistance – min 20 A.

    • Carryoutfunctionaltestontheblowermotor,todothisremovethecon-nectorfromthecontrolbox.Applyatestvoltage(seepage12)totheblow-ermotorandmeasurethecurrentintensityafter40sec.

    Currentintensity<6.5A–blowermotorok–>replacecontrolbox. Currentintensity>6.5A—>replaceblower.• Checkwiringforshortcircuit.

    033 Blowermotorwon’trotateorshortcircuitafternegative

    Please note!

    Ensurecompliancewiththetestvolt-age(seepage12).Thecomponentisdestroyedifthevoltagevalueisexceeded.Ensure the power pack has ad-equate short-circuit resistance – min 20 A.

    Speeddeviation>10%fromsetpointvalueforlongerthan30seconds.Useanon-contactr.p.m.countertomeasurethespeedofthecombustionairfan(seepage12fortestspeedandtestvoltage).

    • Speedtoolow: Blowerblocks–checkblowerforfreerunning,ifnecessaryremoveforeignbody,ifok—>checkblower(seefaultcode032).

    • Speedtoohigh: –Magnetmissingfromblowerimpeller—>replaceblower. – Speedsensorincontrolboxisdefective—>replacecontrolbox.• Checkwiringforshortcircuit.

    * Thisfaultcodeorohmicvalueisvalidforanewgenerationcontrolboxonly.Thisdiffersfromthecontrolboxtodatebyitscableloomwrappedincabletapeandbyatemperaturesensormountedontheside,whichbecomesvisiblewhenthecoverisremoved.

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 25

    Troubleshooting4Fault codeDisplay

    Fault description Comments• Remedial action

    034 * Blowermotor,outlet(+)shortcircuitafterUB(batteryvoltage)

    • Checkthattheleadharnessoftheblowermotorhasbeencorrectlylaidandcheckfordamage,ifok—>removeleadharnessatcontrolboxandcheckforcontinuity,ifok—>replacecontrolbox.

    047 Meteringpump–shortcircuitoroverload

    • Removeconnectorfromthemeteringpump,ifthefaultcode048(inter-ruption)isdisplayedthemeteringpumpisdefective—>replacemeteringpump.

    • Ifthefaultcode047continuestobedisplayed,disconnectconnectorS1/B1attheheater,andattheconnectorB1,PIN5checkthecable12gn/rtuptothemeteringpumpforshortcircuittonegative(PIN10),ifok–>replacecontrolbox.

    048 Meteringpump–interruption • Disconnectconnectorfrommeteringpumpandmeasuretheresistancevalueofthemeteringpump(seePage12forvalues),ifresistancevalueok,re-connectthecableloomtothemeteringpump.

    • DisconnectconnectorS1/B1attheheaterandmeasuretheresistancevalue(seePage12)betweenPIN5andPIN10,ifok—>replacecontrolbox.

    049 * Meteringpumpoutlet(+)Shortcircuit–afterUB(batteryvoltage)

    • Checkthattheleadharnessofthemeteringpumphasbeencorrectlylaidandcheckfordamage,ifok—>removeleadharnessandcheckforconti-nuity,ifok—>replacecontrolbox.

    050 Toomanyfailedstartattempts(opera-tinglock-out)

    Thecontrolboxlocksaftertoomanyfailedstartattempts(max.255startat-tempts).• Unlockthecontrolboxbydeletingthefaultmemorywiththetimer,thediagnosticunit,EDiTHdiagnostictool,theTP5radioremotecontrol/EasyStartR+andtheEasyStartTtimer.

    051 Flamedetectedwhenswitchingon If,afterbeingswitchedon,theresistancevalueoftheflamesensoris1274(>70°C)theheater’sfanrunsforapprox15mintocooldown,iftheresist-ancedoesnotfallbelowtheaforementionedvaluewithin15mintheheaterisswitchedoff.

    • Checkflamesensor,seePage32fordiagramandtableofvalues,ifok—>replacecontrolbox.

    052 Safetytimeexceeded Noflamedetectedwithinthestartphase.• Checkexhaustandcombustionairsystem.• Checkfuelsupply/measurefuelquantity,seePage36.• Checksparkplug(seefaultcode020and021)• Checkflamesensor,diagramandtableofvalues,seePage32,ifok—>replacecontrolbox.

    053

    054

    055

    056

    Flamecutoutinthe

    “POWER”controlstage

    “HIGH”controlstage

    “MEDIUM”controlstage

    “LOW”controlstage

    Theheaterhasignited(flamedetected)andsignalsflamecutoutduringapowerstage.

    • Checkexhaustandcombustionairsystem.• Checkfuelsupply/measurefuelquantity,seePage36.• Checkflamesensor,diagramandtableofvalues,seePage32,ifok—>replacecontrolbox.

    057 Flamecutoutfromstartphase(Displayonlyifheaterslabelled“H-Kit”onthenameplate.)

    Aflamecutoutwasdetectedduringthestartphase..• Checkexhaustandcombustionairsystem.• Checkfuelsupply/measurefuelquantity,seePage36.• Checkglowplug(seefaultcode020and021).• Checkflamesensor,diagramandvaluestable,seepage32,ifok—>replacecontrolbox.

    060 Externaltemperaturesensor–interruption

    • DisconnecttheconnectorS4/B4oftheexternaltemperaturesensorandmeasuretheresistancevalueatconnectorB2,fordiagramandtableofva-luesseePage12,iftemperaturesensorok,reassembleconnectorS4/B4.

    • DisconnectconnectorS1/B1attheheaterandmeasuretheresistancevalueinconnectorhousingB1betweenPIN6andPIN12.Ifinterruptedtheohmicvalueis>7175/3k*.Ifresistancevalueok—>replacecontrolbox.

    * Thisfaultcodeorohmicvalueisvalidforanewgenerationcontrolboxonly.Thisdiffersfromthecontrolboxtodatebyitscableloomwrappedincabletapeandbyatemperaturesensormountedontheside,whichbecomesvisiblewhenthecoverisremoved.

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 26

    Troubleshooting4Fault codeDisplay

    Fault description Comments• Remedial action

    061 Externaltemperaturesensor–shortcircuit

    • DisconnectconnectorS4/B4oftheexternaltemperaturesensor,iffaultcode060isdisplayed—>checkexternaltemperaturesensor,diagramandtableofvalues,seePage32.Iftemperaturesensorok—>checkconnec-tioncables0.5grand0.5br/wsforshortcircuit,ifok,reassemblethecon-nectorS2/B2.

    • DisconnectconnectorS1/B1attheheaterandmeasuretheresistancevalueinconnectorhousingB1betweenPIN6andPIN12.Incaseofshortcircuittheohmicvalueis<486/<800*.

    Iferror061continuestobedisplayed—>replacecontrolbox.

    062 Controlunit–interruption

    Please note!

    Refertonotesondiagnosiswithmini-controlleronpage14.

    Heaterrunsin„High“controlstageonly• Removeconnectoratthecontrolunitandmeasuretheresistancevalueofthesetpointpotentiometer,forconnectorpinsseePage42onwards.Iftheresistancevalueisok,reconnectconnectoratthecontrolunit.

    • DisconnectconnectorS1/B1attheheater,measuretheresistancevaluebetweenPIN6andPIN7inconnectorhousingB1,ifresistancevalueok—>replacecontrolbox.Resistancevalueincaseofinterruption>7175 />3k *.Normalvalues:seepage12.

    063 Controlunit–shortcircuit

    Faultrecognitiononlyworksinhea-tingmode.If,ontheotherhand,theshortcircuithasalreadyoccurredandthentheheaterisswitchedon,„Venti-lation“isactive(notafaultcode).

    • Ifthe“Ventilate”switchisinstalled,disconnectitandcheckitworks.Ifnotok—>replaceswitch.

    • Disconnectconnectoratcontrolunit,iferrorcode062isdisplayed,replacethecontrolunit.Ifcontrolunitok,checkconnectioncables0.5gr/rtand0.5br/wsforshortcircuit,ifok—>reconnectconnectoratcontrolunit.

    • DisconnectconnectorS1/B1attheheater,iftheerror063continuestobedisplayed—>replacecontrolbox.Resistancevalueincaseofshort-circuit<486 / <800 *.Normalvalues:seepage12.

    064 Flamesensor–interruption • Dismantlecontrolboxanddisconnectgreenconnectorfromcontrolbox.Checkflamesensor,diagramandtableofvalues,seePage32,ifflamesen-sorok—>replacecontrolbox.Resistancevalueincaseofinterruption>7175 />3k *.

    065 Flamesensor–shortcircuit Dismantlecontrolbox,removegreenconnectorfromcontrolbox,iferror064isdisplayed—>replacecombinationsensor.

    Iferror065continuestobedisplayed—>replacecontrolbox. Resistancevalueincaseofshortcircuit<486 /<500*,seealsodia-gramonPage32.

    071 Overheatingsensor–interruption • Dismantlecontrolbox,disconnectblueandgreenconnectorsfromcontrolbox.MeasureresistancevalueatblueconnectorPIN1(cable0.52bl)andatgreenconnectorPIN2(cable0.52br/ws),ifok,—>replacecontrolbox.

    Resistancevalueincaseofinterruption>223k />1600k *,seealsodiagramonPage32.

    072 Overheatingsensor–shortcircuit • Dismantlecontrolbox,removeblueconnectorfromcontrolbox,iferror071isdisplayed—>replacecombinationsensor.

    Iferror072continuestobedisplayed—>replacecontrolbox. Resistancevalueincaseofshortcircuit<183 /<95*,seealsodia-gramonPage32.

    074 * Controlboxdefective •Overheatingthresholdvalueisnotdetectedbycontrolbox—>replacecon-trolbox.

    090 Controlboxdefective(internalfault) • Replacecontrolbox.

    091 Externalinterferencevoltage • Controlboxfaultduetointerferencevoltagesfromthevehicle’selectricalsystem.Possiblecauses:

    Poorbattery,charger—>removeinterferencevoltage.

    092 Controlboxisdefective(ROMerror) • Replacecontrolbox.

    093 * Controlboxdefective • Replacecontrolbox.

    * Thisfaultcodeorohmicvalueisvalidforanewgenerationcontrolboxonly.Thisdiffersfromthecontrolboxtodatebyitscableloomwrappedincabletapeandbyatemperaturesensormountedontheside,whichbecomesvisiblewhenthecoverisremoved.

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 27

    Troubleshooting4Fault codeDisplay

    Fault description Comments• Remedial action

    094 Controlboxdefective(EEPROM-Fehler)

    • Replacecontrolbox.

    095 * Controlboxdefective • Replacecontrolbox.

    096 Internaltemperaturesensordefective • Replacecontrolboxoruseanexternalroomtemperaturesensor..

    097 Controlboxdefective • SReplacecontrolbox.

    098 * Controlboxdefective • Replacecontrolbox.

    099 * Toomanyresetsinsequence

    Transistorerrorincontrolbox

    • Voltageshort-term<5–6volt(for12volt)or<7–8volt(for24volt). Incaseofavoltagedrop,checkthefuses,thesupplycables,thenegativeconnectionsandthepositivesupportpointonthebatteryforcorrosionandcorrectcontact.

    Testcontrolboxwithtestingdevice,ifok—>checkleadharnessoftheex-ternalcomponentshasbeencorrectlylaidandcheckfordamage,ifok—>checkleadharnessforcontinuity,ifok—>replacecontrolbox.

    Air pressure sensor fault code displayFault code display

    Fault description Comments• Remedial action

    0 Nofaults —

    11 Communicationloss Interruptionofthediagnosticscablebetweenthecontrolbox(heater)andtheairpressuresensor• Checkwiringandplug-inconnections

    12 Noaltitudeadjustment Controlbox(heater)doesnotsupportaltitudeoperationwiththeairpressuresensor• Useacontrolbox(heater)whichsupportsaltitudeadjustment

    13 Airpressuresensorfault Theairpressuresensorisdefective• Replacetheairpressuresensor

    * Thisfaultcodeorohmicvalueisvalidforanewgenerationcontrolboxonly.Thisdiffersfromthecontrolboxtodatebyitscableloomwrappedincabletapeandbyatemperaturesensormountedontheside,whichbecomesvisiblewhenthecoverisremoved.

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 28

    Repair instructions

    Thepermittedrepairworktotheheaterisdescribedinthe“RepairInstructions”chapter.Ifextensiverepairsarenecessary,itmakessensetodismantletheheater.

    Theheaterisassembledinthereverseorder,ifapplicablenotadditionalinstructions.

    Aftercompletingalltheworkontheheater,youmustcarryoutafunctionalcheck(seePage4).

    Always observe the following safety instructions before working on the heater:

    Danger!Risk of injury, burns and poisoning!• Alwaysswitchofftheheaterbeforehandandleaveittocool.• Disconnectthebattery.• Theheatermustnotbeoperatedinclosedroomssuchasgaragesorworkshops.

    Exception: Exhaustsuctionavailabledirectlyattheentrytotheexhaustpipe.

    Caution!• Thesealsofdismantledcomponentsmustberenewed.• Duringrepairwork,checkallcomponentsfordamageandifnecessaryreplace.

    • Checkconnectorcontacts,plug-inconnectionsandcablesforcorrosionanddamageandifnecessaryrepair.

    • OnlyeveruseEberspächersparepartsifreplacementsarenecessary.

    • Operationortheafterrunningoftheheatermayonlybestoppedinanemergency(see“EMERGENCYOFF”Page8)byinterruptingthebatterycurrent(riskofheateroverheat-ing).

    Repairinstructions5Special tool

    AMP release tool

    TheAMPreleasetoolisusedtoreleaseplug-incontactsinaconnectorhousing.

    ThisreleasetoolcanbeordereddirectlyfromAMP.

    • ForMicroTimer: AMPOrderNo.0-0539960-1

    • ForJunior-Power-Timer: AMP-Bestell-Nr.1-1579007-6

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 29

    Assembly drawing Airtronic / Airtronic M

    Partslist

    1 Combustionairfan 2 Seal–combustionairfan/heatexchanger 3 Combustionchamber 4 Seal–combustionchamber/heatexchanger 5 Heatexchanger 6 Controlbox 7 Combinationsensor(overheating/flamesensor)with

    assemblytool

    8 Bracket 9 Glowplug,withspecialtool(SW12)10 Lining–glowplugsocket,withassemblytool11 Cover12 Outershell(bottomsection)13 Flangeseal14 Sleeve(forpetrolonly)

    Repairinstructions5

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 30

    Repair step 1Remove the heater’s cover (seeFigure1)

    Unlockbothfasteningclips,liftthecoverandremovefromthefront.

    Theheater’scovermustberemovedforallrepairsteps.Ifnecessary,waituntiltheunithascooleddown.

    Cableharnessoutletfromthehousingoptionallyonleftorright-handside.

    1. 2.

    Figure1

    Cover Fasteningclips

    Repair step 2Dismantle control box (seeFigure2)

    • Repairstep1.• Unscrewfixingscrew,• Presstogethertheretainingclamps.• Removethecontrolboxfromabove.• Unclipcablesfromholderoncontrolbox (Notethepositionofthecables).• Pullgrommetoutoftheoutershell(bottomsection).• Pullconnectoroutofcontrolbox,thecontrolboxcannowberemoved.

    Whenassemblingthecontrolbox,ensurethecablesareclip-pedintotheholderonthecontrolboxandtheconnectorsarepluggedintothecontrolbox(unmistakeable).TighteningtorqueofthefixingscrewItem:2+0.2Nm

    Figure2

    Fixingscrew Retainingclamp Controlbox Grommet

    Check control box

    TheEDiTHdiagnostictoolisrequiredtocheckthecontrolboxwhenitisdismantled.Forconnection,useandOrderNo.,seePage19.

    5 Repairinstructions

    Please note!

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 31

    Repair step 3Dismantle glow plug (seeFigure3)

    • Repairstep2.• Disconnectconnectorfrom“glowplug”cableloomoncon-trolbox.

    • Removerubbergrommetandunscrewtheglowplugusingthespecialtool(SW12).

    (Thespecialtoolisincludedwiththeglowplug).

    Tighteningtorqueforglowplug:6+0.5Nm

    Specialglowplugtool

    Withtheglowplugdismantled,visuallycheckthesocketliningoftheinstalledglowplugfordirt.Iftheliningishighlysoiledanditssurfaceclosed,renewthelining.

    Figure3

    Glowplug Connectorfromglowplugcableloom Rubbergrommet

    Removing the lining (see Figure 4)

    Uselongnoseplierstopulltheliningoutofthesocketfromabove.Blowoutthesocketwithcompressedairandifnecessarycleanthesideventhole.

    Usethespecialtooltoinstallthenewlining.Thespecialtoolisincludedwiththelining.Pushtheliningonthetool.Pushinthetooltogetherwiththelininguptothelimitstop.

    Figure4

    Specialtool Lining

    5

    Repairinstructions

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 32

    Repair step 5 Dismantle combination sensor (overheating / flame sen-sor) (seeFigure5)

    • Repairstep2.• Removebothconnectorsfromthe“combinationsensor”cableloomatthecontrolbox.

    • Unlockbracketfromcombinationsensor.• Removethecombinationsensor.

    Figure5

    “Combinationsensor”cableloom Bracket,unlocked

    Check combination sensor

    Theexternaltemperaturesensormustbecheckedwithadig-italmultimeter.Replacetheoverheatingorflamesensoriftheresistancevalueisnotthesameasthecurveinthediagramorthetableofvalues.

    Table of overheating sensor values

    Temperature °C Resistance k min. max. – 40 1597.00 1913.00 – 20 458.80 533.40 0 154.70 175.50 20 59.30 65.84 40 25.02 28.04 60 11.56 13.16 80 5.782 6.678 100 3.095 3.623 120 1.757 2.081 140 1.050 1.256 160 0.6554 0.792 180 0.4253 0.5187 200 0.2857 0.3513

    Table of flame sensor values

    Temperature °C Resistance min. max.– 40 842.7 825.9 859.6– 20 921.6 803.2 940.0 0 1000.0 980.0 1020.0 20 1077.9 1056.4 1099.5 40 1155.4 1132.3 1178.5 60 1232.4 1207.8 1257.1 80 1308.9 1282.8 1335.1 100 1385.1 1357.4 1412.8 120 1460.7 1431.5 1489.9 140 1535.8 1505.1 1566.6 160 1610.5 1578.3 1642.8

    Resistance(kOhm)

    Temperature(°C)

    5

    Notethemax.temperatureof320°Cforthetest.

    Temperature(°C)

    Resistance(Ohm)

    Overheating sensor Flame sensor

    Repairinstructions

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 33

    Sketch2

    Specialtool–onlyrequiredforAirtronic Combinationsensor

    Figure6

    Specialtool–onlyrequiredforAirtronic Combinationsensor

    Repair step 6 Install combination sensor (overheating / flame sensor)(seeFigure6,7andSketch2–4)

    •Repairstep2.• ForAirtronic(assemblywithspecialtool,seeSketch2) Pushthespecialtoolaontothecombinationsensorb.Usethespecialtooltopositionthecombinationsensorontheheatexchanger,thespecialtoolslidesontheheatexchang-eruntilthecombinationsensorhitsthecollar(installationpositionofthecombinationsensor).

    Lockthecombinationsensor’sbracketandremovethespecialtool.Thenalwayscheckthatthecombinationsen-sorsitsflatontheheatexchanger.Ifnecessary,useaidssuchasamirrorandlamp.

    Laythe“combinationsensor”cableloomalongthebracket,throughthebracketeyeletuptothecontrolboxandcon-nect.

    • ForAirtronicM(assemblywithoutspecialtool) Placethecombinationsensorontheheatexchanger;itisimportanttoensurethecombinationsensorsitsflatontheheatexchanger.

    Lockthecombinationsensor’sbracketandcheckagainthatthecombinationsensorissittingflatontheheatex-changer.

    Laythe“combinationsensor”cableloomalongthebracket,throughthebracketeyeletuptothecontrolboxandcon-nect.

    Sketch4

    Bracket Combinationsensor

    Figure7

    Bracket,locked “Combinationsensor”cableloom Specialtool–onlyrequiredforAirtronic

    Circuit diagram for combination sensor (overheating sensor / flame sensor)

    Sketch3

    NTC50KΩ=overheatingsensorPT1000=flamesensor

    Connectorblue

    Connectorgreen

    5 Repairinstructions

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 34

    Repair step 7 Dismantle heat exchanger (seeFigure8andSketch5)Dismantle combustion air fan (seeFigure8andSketch5)

    • Repairstep2.• Removeflangeseal.Removeheaterfromtheoutershell(bottomsection).

    Unscrewthe4fixingscrewsfromthecombustionairfan. Removethecombustionairfanandthesealfromtheheatexchanger.

    Caution!Wheninstallingthecombustionairfanthesealmustalwaysberenewed.

    Tightenthe4fixingscrewsofthecombustionairfan–intheordershowninSketche–withatighteningtorqueof4+0.5Nm. Figure8

    Combustionairfan Heatexchanger Fixingscrew

    Sketch5

    1–4 Tightenthefixingscrewsinthisorderwithatightening

    torqueof4+0.5Nm

    5

    5 Alwaysrenewthesealbetweenthecombustionairfanandtheheatexchanger.

    5

    2

    4

    3

    1

    Repairinstructionshttp://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 35

    Repair step 8Dismantle combustion chamber (seeFigure9andSketch6)

    • Repairstep3.• Repairstep7.• Unscrewthefixingscrews. IntheAirtronic=3fixingscrews, intheAirtronicM=4fixingscrews.• Pulloutthecombustionchamberfromthefrontandremovetheheatexchanger’sseal.

    Caution!Whenassemblingthecombustionchamber,alwaysrenewtheseal,whichisincludedwiththesparepart.

    Tightenthefixingscrewsofthecombustionchamberwithatighteningtorqueof5+0.5Nm

    Iftheheatexchangerisreplacedthecombinationsensor(overheatingsensor/flamesensor)mustbedismantledandfittedonthenewheatexchanger(seeRepairstep6,Page33).

    Sketch6

    1Combustionchamber2Alwaysrenewthesealbetweenthecombustionchamberandtheheatexchanger.

    3Heatexchanger

    4Fixingscrew Airtronic=3fixingscrews AirtronicM=4fixingscrews

    Figure9

    Combustionchamber Heatexchanger Fixingscrew Airtronic=3fixingscrews AirtronicM=4fixingscrews

    5

    4

    1

    2

    3

    Repairinstructions

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 36

    Measuring the fuel quantity

    1. Preparation

    Removethefuelpipeattheheaterandinsertameasuringcylinder(size10ml).Switchontheheater,ifthefuelisuniformlypumped(beginsapprox.60secafterbeingswitchedon),thefuelpipeisfullandvented.Switchoffheaterandemptymeasuringcylinder.

    Forprecisefuelmeasurementatleast11volt/22voltormaximum13volt/26voltshouldbeappliedtothecontrolboxduringthemeasurement.

    2. Measurement

    Thefuelbeginstobepumpedapprox.60secafterswitchingontheheater.Holdthemeasuringcylinderatglowpluglevelduringthemeasurement.

    Airtronic Afterapprox.90secofthefuelbeingpumpeditisautomati-callyswitchedoff.

    Caution!Switch off heater,asotherwiseitwillstartupagain.

    Readoffthequantityoffuelinthemeasuringcylinder.

    Airtronic MAfterapprox.105secofthefuelbeingpumpeditisautomati-callyswitchedoff.

    Caution!Switch off heater,asotherwiseitwillstartupagain.

    Readoffthequantityoffuelinthemeasuringcylinder..

    Ifthemeasuredfuelquantityliesoutsidethevaluesgivenbelow,themeteringpumpmustbereplaced.

    1 Heater2 Meteringpump

    Check fuel supply

    Beforemeasuringthefuelquantity,checkthefollowingpointsinthefuelsupply.

    • Checkthescreeninthemeteringpump.• Checkthelayingofthefuelpipes.• Checkfuelpipesforleaks.• Checkandtightenthehoseconnections.• Isthefuelremovalinstalledaccordingtothedetailsinthetechnicaldescription?

    5

    3 Measuringcylinder(size10ml)4 Disconnectfuelpipeatheaterandinsertinameasuringcylinder.

    1

    2

    3

    4

    Table of values – fuel quantity

    Heater Fuel Fuel quantity

    Minimal Maximal

    Airtronic diesel 3,5ml/90sec 4,3ml/90sec

    AirtronicM petrol 6,8ml/105sec 7,6ml/105sec

    AirtronicM diesel 5,0ml/105sec 6,0ml/105sec

    Bitte beachten!

    Repairinstructionshttp://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 37

    Circuitdiagram6Overview of the parts lists and circuit diagrams

    PartslistcircuitdiagramAirtronic/AirtronicM................................................................................................................................ 38CircuitdiagramAirtronic/AirtronicM.............................................................................................................................................. 39 Thiscircuitdiagramisforheaterswithonediagnosticscableandacontrolboxcableloomwhichisfirmlyencapsulated.CircuitdiagramAirtronic/AirtronicM.............................................................................................................................................. 40 Thiscircuitdiagramisforheaterswith2diagnosticscableandwhosecontrolboxcableloomiswoundwithcabletape.

    Partslistcontrolunits..................................................................................................................................................................... 41Circuitdiagramscontrolunits...................................................................................................................................................42–48

    PartslistEasyStartR+/R/Tcontrolunits..................................................................................................................................... 49EasyStartR+circuitdiagram...................................................................................................................................................50–52EasyStartRcircuitdiagram......................................................................................................................................................53–55EasyStartTcircuitdiagram....................................................................................................................................................... 56,57

    PartslistcircuitdiagramAirtronic/AirtronicM–ADR..................................................................................................................... 58CircuitdiagramAirtronic/AirtronicM–ADR................................................................................................................................... 59 Thiscircuitdiagramisforheaterswithonediagnosiscableandacontrolboxcableloomwhichisfirmlyencapsulated.CircuitdiagramAirtronic/AirtronicM–ADR................................................................................................................................... 60 Thiscircuitdiagramisforheaterswith2diagnosticscableandwhosecontrolboxcableloomiswoundwithcabletape.

    Partslistcontrolunits–ADR.......................................................................................................................................................... 61Circuitdiagramcontrolunits–ADR............................................................................................................................................... 62EasyStartT–ADRcircuitdiagram............................................................................................................................................ 63,64

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 38

    Parts list circuit diagrams Airtronic / Airtronic M

    1.1 Burnerengine1.2 Glowplug1.5 Overheatingandflamesensor2.1 Controlbox2.2 Meteringpump2.7 Mainfuse 12volt=20A 24volt=10A2.7.1Fuse,actuation5A5.1 Battery

    a) Connectionofcontrolunitandexternalsensoraccord-ingto“controlunits”circuitdiagram

    •rt Powersupply,plus–terminal30 •ge Switch-onsignal–S+ •gr Temperature–actualvalue •wsrt Switchofftheanti-theftalarmsystem (ADR–feedbacksignalfortimer) •br Powersupply,minus–terminal31 •blws Diagnosis •grrt Temperature–setpoint •brws Groundconnectionforexternaltempera-

    turesensorandtemperaturesetpoint b) Option •Vehiclefancontrol and/or •separatefreshairfan

    Thecircuitdiagramsareassignedviatheinstalledcontrolbox:• Controlboxwithonediagnosticscable: Atthe16pinconnectorthediagnosticscablebl/wsiscon-nectedtochamber8.

    • Controlboxwith2diagnosticscablesandJEdiagnosis: Atthe16pinconnectorthediagnosticscablebl/wsisconnectedtochamber3,thediagnosticscablebl/geisconnectedtochamber8.

    • Insulateunusedcableends.• Connectorsandbushhousingsareshownfromthecableinletside.

    Circuitdiagram6

    Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 39

    Circuit diagram – Airtronic / Airtronic M

    252069009801APartslistPage38

    Circuitdiagram6

    Thiscircuitdiagramisforheaterswithadiagnosticscableandwhosecontrolboxcableloomwhichisfirmlyencapsulated.

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 40

    Circuit diagram – Airtronic / Airtronic M

    Circuitdiagram6

    Thiscircuitdiagramisforheaterswith2diagnosticscableandwhosecontrolunitcableloomiswoundwithcabletape.

    252069009801BPartslistPage38

    Bitte beachten!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic

  • 41

    Circuitdiagram6Parts list circuit diagrams, control units

    2.15.1 Temperaturesensor,external(roomtemperature)2.15.9 Temperaturesensor(externaltemperature)3.1.9 Changeoverswitch“heat/ventilate”3.1.11 Controlunit,round3.1.16 Radioremotecontrolbutton3.1.17 MinicontrollerAirtronic3.1.18 ButtonCalltronic3.2.8 Moduletimer(ADR–potentiometer)3.2.12 Timer,mini–12/24volt3.2.14 Lighting,timer,mini–12voltonly3.3.6 RadioremotecontrolstationarypartTP41i3.3.7 RadioremotecontrolstationarypartTP53.3.8 RemotecontrolCalltronic3.8.3 Antenna3.9.1 Diagnosis,JEdiagnosis

    a)ConnectioncontrolelementstotheAirtronic •rt Powersupply,plus–terminal30 •ge Switch-onsignal–S+ •gr Temperature–actualvalue •wsrt Switchoffburglaralarm (ADR–feedbackfortimer) •br Powersupply,minus–terminal31 •blws Diagnosis •grrt Temperature–setpoint •brws Groundconnectionforexternaltempera-

    turesensorandtemperaturesetpoint b) Terminal15–necessaryforconnectionTP4i c) Lighting,terminal58d) Connection,diagnosticunit e) Connection,externaltemperaturesensor g) Connection,externalheatingbutton h) Connection,radioremotecontrolTP4i j) Connection,temperaturesensor(outsidetemperature) k) Ifconnectingtimerorradioreceiver– Disconnectcablehere l) Connection,change-overswitch“heat/ventilate” option) Initialoperation:Activatechangeoverswitch “heat/ventilate”,thenswitchontheheater. z) Lighting,terminal58

    • Insulateunusedcableends.• Connectorsandbushhousingsareshownfromthecableinletside.

    Cable colours circuit diagramssw = blackws = whitert = redge = yellowgn = greenvi = violetbr = browngr = greybl = blueli = purple

    Please note!

    http://www.hagerbv.com/catalogus/87-eberspacher-d2-airtronic