Top Banner
AFEII update (first 224 TriP channels) Juan Estrada Paul Rubinov
17

AFEII update (first 224 TriP channels) Juan Estrada Paul Rubinov

Jan 02, 2016

Download

Documents

elvis-gilbert

AFEII update (first 224 TriP channels) Juan Estrada Paul Rubinov. Working TriP Chips. 1 bad TriP chip. MCMIIc (32ch.). MCMIIb (64ch.). MCMIIb. FPGA. JTAG cable (temporary solution). 2 ADCs. DIGITAL. ANALOG. 2 TriP chips inside. Charge injection connector. - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

AFEII update(first 224 TriP channels)

Juan Estrada Paul Rubinov

Page 2: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

Working TriP Chips

MCMIIb (64ch.)

MCMIIc (32ch.)

1 bad TriP chip

Page 3: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

MCMIIb

2 TriP chips inside

2 ADCs

FPGA

JTAG cable(temporary solution)

Charge injectionconnector

DIGITALANALOG

Page 4: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

Typical Discriminator Scan

The total spread for this Trip (32 channels) is about 4 fC

Page 5: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

Things we want to test

1. With Abder’s test we decided that the chip could not be operated in the design mode because it will give large spread in the discrimininators. We want to confirm this. There is a workaround to operate the TriP, we have to test it in the AFE.

2. How does a pulse in the previous event affect us

3. We want to learn about the analog pedestal differences inside the TriP.

4. Any layout issues in the MCM?

Page 6: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

Design operating mode/workaround

What you need to know to understand the problem:

• The trip has 16 discriminator outputs and 32 channels. DIGENUP and DIGENLOW choose which bank is at the output.

• The discriminators in the trip are always high (1) and go low (0) when they fire.

• The discriminators in the trip are also low (0) when no bank is enable.

Design operating mode:

During the reset (no integration time) one would enable DIGENUP and DIGENLOW. During integration time both are disable. This produces the 16 outputs to swing from at the same time when no discriminator has fired. This swing produces a transient signal that generates noise.

Workaround:

Have always one bank enable. The discriminators can fire in the integration window affecting.

Page 7: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

Workaround

Always one discriminator bank is enabled

Page 8: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

Design operating Mode, “16 channels swing”.

Page 9: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

Design operating Mode, “16 channels swing”.The only difference here is that the “swing” was moved 8 nsec later.

Page 10: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

Conclusion for the operating modes

• We have 2 operation modes that can be usable.

• The transient generated in the design mode does not affect us so bad in the AFE and has a less spread in the discriminators when compared with the workaround.

• In order to decide how to operate the TriP we need a test in the cryostat when the signal coming from a VLPC (correct electrical properties).

• The signal in the previous bucket seems to affect more the workaround operation mode. This again points to the design mode as a better solution.

Page 11: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

Workaround

Always one discriminator bank is enabled

Significant effect from the previous bucket. (1/25)

Page 12: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

Design operating Mode, “16 channels swing”.

No effect from the previous bucket.

Page 13: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

We have 2 MCMs with TriP-1 operational, in both we see channel 0 far (3 fC) away of the rest. This is most likely a layout issue in MCMIIb.

Page 14: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

Analog Pedestal Spread in Trip-1

Layout?

Page 15: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

Analog Pedestal Spread in Trip-2

Page 16: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

Timing scan (20 fC input)

For the design operating mode there is full efficiency in a window of 50 nsec. Similar for the other mode.

Page 17: AFEII update (first 224 TriP channels) Juan Estrada  Paul Rubinov

Conclusions

1. We have to modes to operate the TriP and need to test it in the cryostat with VLPCs to decide which is better.

2. There are some layout issues on the MCMs, we will have to consider this for the final AFEII (useful information)

3. 8 TriPs work from a total of 9 tested!!!!