ADDENDUM NO. 1 EDUCATION BUILDING FOR GRACE COMMUNITY CHURCH 10938 HOOD ROAD SOUTH JACKSONVILLE, FLORIDA RDSA PROJECT NO. D-17-04 MAY 9, 2018 THIS ADDENDUM IS ISSUED FOR THE INFORMATION OF THE BIDDERS ON THE ABOVE TITLED PROJECT AND SHALL BE PART OF THE CONTRACT DOCUMENTS UNLESS SPECIFICALLY INDICATED OTHERWISE. CHANGES TO THE PROJECT MANUAL ARE ISSUED AS FULL REPLACEMENT SECTIONS WITH REVISIONS (IF ANY) IN BOLD AND DELETIONS (IF ANY) IN STRIKETHROUGH TEXT. NEW SECTIONS (IF ANY) WILL BE ISSUED IN FULL WITHOUT BOLD TEXT. ALL REVISED AND NEW SECTIONS WILL BEAR THE DATE OF THE ADDENDUM. CHANGES TO THE DRAWINGS ARE ISSUED AS FULL SIZE REPLACEMENT SHEETS WITH REVISIONS CLOUDED AND NOTED. NEW SHEETS (IF ANY) WILL BE ISSUED WITHOUT CLOUDS. ALL REVISED AND NEW SHEETS WILL BEAR THE DATE OF THE ADDENDUM. THE FOLLOWING CHANGES SHALL BE MADE TO THE PROJECT MANUAL, DRAWINGS AND OTHER PROJECT DOCUMENTS WHICH BEAR THE PROJECT TITLE ABOVE. ALL CHANGES ARE INDICATED ON THE ATTACHED SPECIFICATION SECTIONS AND DRAWINGS. ADDITIONAL DESCRIPTIONS OF THE CHANGES INCLUDED BELOW (IF ANY) ARE FOR CONVENIENCE OF THE BIDDERS AND ARE NOT PART OF THE CONTRACT DOCUMENTS. ANSWERS TO QUESTIONS FROM BIDDERS AND PRODUCT SUBSTITUTION REQUESTS ARE OFFERED FOR GENERAL INFORMATION AND ARE NOT PART OF THE CONTRACT DOCUMENTS. CHANGES TO PROJECT MANUAL ITEM NO. 1: SECTION 000000 TABLE OF CONTENTS A. Delete entirely and replace with attached Section 000000 Table of Contents. ITEM NO. 2: SECTION 007300 SUPPLEMENTARY CONDITIONS A. Insert new Section 007300 Supplementary Conditions into Project Manual. Refer to attachment.
16
Embed
ADDENDUM NO. 1 EDUCATION BUILDING FOR GRACE … · addendum no. 1 education building for grace community church 10938 hood road south jacksonville, florida rdsa project no. d-17-04
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
ADDENDUM NO. 1
EDUCATION BUILDING FOR GRACE COMMUNITY CHURCH
10938 HOOD ROAD SOUTH JACKSONVILLE, FLORIDA
RDSA PROJECT NO. D-17-04
MAY 9, 2018
THIS ADDENDUM IS ISSUED FOR THE INFORMATION OF THE BIDDERS ON THE ABOVE TITLED PROJECT AND SHALL BE PART OF THE CONTRACT DOCUMENTS UNLESS SPECIFICALLY INDICATED OTHERWISE. CHANGES TO THE PROJECT MANUAL ARE ISSUED AS FULL REPLACEMENT SECTIONS WITH REVISIONS (IF ANY) IN BOLD AND DELETIONS (IF ANY) IN STRIKETHROUGH TEXT. NEW SECTIONS (IF ANY) WILL BE ISSUED IN FULL WITHOUT BOLD TEXT. ALL REVISED AND NEW SECTIONS WILL BEAR THE DATE OF THE ADDENDUM. CHANGES TO THE DRAWINGS ARE ISSUED AS FULL SIZE REPLACEMENT SHEETS WITH REVISIONS CLOUDED AND NOTED. NEW SHEETS (IF ANY) WILL BE ISSUED WITHOUT CLOUDS. ALL REVISED AND NEW SHEETS WILL BEAR THE DATE OF THE ADDENDUM. THE FOLLOWING CHANGES SHALL BE MADE TO THE PROJECT MANUAL, DRAWINGS AND OTHER PROJECT DOCUMENTS WHICH BEAR THE PROJECT TITLE ABOVE. ALL CHANGES ARE INDICATED ON THE ATTACHED SPECIFICATION SECTIONS AND DRAWINGS. ADDITIONAL DESCRIPTIONS OF THE CHANGES INCLUDED BELOW (IF ANY) ARE FOR CONVENIENCE OF THE BIDDERS AND ARE NOT PART OF THE CONTRACT DOCUMENTS. ANSWERS TO QUESTIONS FROM BIDDERS AND PRODUCT SUBSTITUTION REQUESTS ARE OFFERED FOR GENERAL INFORMATION AND ARE NOT PART OF THE CONTRACT DOCUMENTS.
CHANGES TO PROJECT MANUAL
ITEM NO. 1: SECTION 000000 TABLE OF CONTENTS A. Delete entirely and replace with attached Section 000000 Table of Contents.
A. Insert new Section 007300 Supplementary Conditions into Project Manual. Refer to attachment.
EDUCATION BUILDING ADDENDUM NO. 1 GRACE COMMUNITY CHURCH MAY 9, 2018 RDSA PROJECT NO. D-17-04 PAGE 2 of 4
CHANGES TO DRAWINGS
ITEM NO. 1: SHEET G-2 - REMOVE DRAWING AND REPLACE WITH ATTACHED REVISED DRAWING A. Revised Drawing Index to include new dates for sheets revised as part of this Addendum.
ITEM NO. 2: SHEET A-4 - REMOVE DRAWING AND REPLACE WITH ATTACHED REVISED DRAWING
A. Added window symbols for several windows. ITEM NO. 3: SHEET A-11 - REMOVE DRAWING AND REPLACE WITH ATTACHED REVISED DRAWING
A. Added information about basis of design wall sheathing at Connecting Corridor. ITEM NO. 4: SHEET A-21 - REMOVE DRAWING AND REPLACE WITH ATTACHED REVISED DRAWING
A. Added information about basis of design window film for application to glazing in certain locations. ITEM NO. 5: SHEET A-25 - REMOVE DRAWING AND REPLACE WITH ATTACHED REVISED DRAWING
A. Revised specification for hand sink to coordinate with Plumbing.
ATTACHMENTS
SECTION 000000 TABLE OF CONTENTS, DATED MAY 9, 2018 SECTION 007300 SUPPLEMENTARY CONDITIONS, DATED MAY 9, 2018 SHEET G-2 GENERAL INFORMATION, REVISION 1, DATED MAY 9, 2018 SHEET A-4 FLOOR PLAN – EDUCATION BUILDING, REVISION 1, DATED MAY 9, 2018 SHEET A-11 WALL SECTIONS, REVISION 1, DATED MAY 9, 2018 SHEET A-21 DOOR AND WINDOW SCHEDULES, REVISION 1, DATED MAY 9, 2018 SHEET A-25 MISC DETAILS, REVISION 1, DATED MAY 9, 2018
EDUCATION BUILDING ADDENDUM NO. 1 GRACE COMMUNITY CHURCH MAY 9, 2018 RDSA PROJECT NO. D-17-04 PAGE 3 of 4
QUESTIONS FROM BIDDERS
Q1: Specification Section 015000 – Temporary Facilities and Controls Part 1 Subsection 1.2 Use Charges – Please clarify this section of the bid documents and owners intentions. Answer: Section 015000 accurately indicates the Owner’s intent. Review in its entirety. Q2: Drawing A-1 – Site Key Note #4 – States “Playfield to be fine graded and grassed (sodded) - Refer to Landscape for extent of grassing and landscaping remainder of site.” Drawing L-7 Plant Schedule calls for sod to be Bahia. Please confirm Playfield Grass type? Answer: Bahia is correct. Playfield is for general activities and is not intended for organized sports. Q3: Drawing A-3 – Keyed Demolition Note #3 – States “Relocate electrical and systems panels and light controls - Refer to Electrical.” In the Pre-Bid we discussed the owner self-performing audio-visual and security. Please clarify the electrical “systems” scope of work. Answer: Contractor will provide complete and operational fire alarm system. Contractor will provide pathways for phone/data/security systems as indicated on the drawings. Owner will relocate any non-built in AV equipment in the auditorium. Owner will pull low voltage wire in Contractor provided pathways and Owner will provide/install low voltage terminations, wiring devices and outlets. Owner will reconnect the non-built in AV equipment and/or provide new equipment as necessary. Owner will provide systems testing for any AV system for which Owner relocated equipment. Owner may self-perform or engage others to perform phone/data/security system installation in Contractor provided pathways or otherwise. Relocation of any electrical service panel, fire alarm panel, light switches, etc. shall be by Contractor. New low voltage lighting controls shall be by Contractor. Refer to drawings. Q4: In the Pre-Bid the impact fees were discussed. Please advise. Answer: The water meters are existing to remain. We know of no required impact / connection fees for water utilities. The sanitary sewer system exists on site and will be extended. We know of no required impact / connection fees for sanitary sewer. As mentioned during the Pre-Bid Meeting, we are working with JEA to gain their acceptance of a section of offsite sewer constructed with the original building in the early 2000s. This effort is separate from the Project. Q5: Regarding Concurrency and Mobility Permitting and Fees. May we use an allowance? Answer: The church is exempt from concurrency and mobility fees. This has been confirmed with City of Jacksonville. Q6: In the Pre-Bid, Builders Rick Policy and limits were discussed. Owner was going to discuss. Please clarify. Answer: Contractor to provide Builder’s Risk Insurance. Refer to Addendum No. 1.
Q7: Are there any window treatments on this project? Answer: Window treatments will be Owner furnished / Owner installed.
EDUCATION BUILDING ADDENDUM NO. 1 GRACE COMMUNITY CHURCH MAY 9, 2018 RDSA PROJECT NO. D-17-04 PAGE 4 of 4
Q8: Drawing A-4 – There are two exterior windows in the Age 3 Room. One window is not labeled. Please advise. Answer: The missing window symbols have been added. Refer to Addendum No. 1. Q9: Drawing A-21 – There is a window Type D listed on the window schedule. However on window elevation #3 there is not a window Type D shown, nor can I find one on the drawings. Please advise. Answer: Window Type D is located above Window Type B. Refer to 3/A-21. Q10: Drawing A-25 – Kitchen Key Note K7 calls for a 3-Compartment Elkay Sink. However this sink is not listed on the plumbing fixture schedule on P-3. Answer: Contractor to provide 3-Compartment sink (or approved equivalent) as indicated on 1/A-25. Connections for the “scullery sink” are indicated on Plumbing Fixture Schedule on Sheet P-3. Q11: Drawing A-25 – Kitchen Key Note K2 is calling for an advanced Tabco Stainless Steel Sink. This same sink is listed on Drawing P-3 as P-5 on the fixture schedule. Shown as an Elkay Sink. Please advise. Answer: Elkay model hand sink (or approved equivalent) referred to on Sheet P-3 is acceptable. This has been coordinated. Refer to Addendum No. 1. Q12: Section 072419 – Water Managed Exterior Insulation and Finish System (EIFS). Is StoTherm ci Classic System and acceptable alternate to BASF Senergy Senerflex Channeled Adhesive system indicated as the basis of design? Answer: Subject to specified requirements, StoTherm ci Classic is acceptable.
END OF ADDENDUM NO. 1
EDUCATION BUILDING ADDENDUM NO. 1 - MAY 9, 2018 GRACE COMMUNITY CHURCH RDSA PROJECT NO. D-17-04
TABLE OF CONTENTS 000000 - 1
000000 Table of Contents
DIVISION 1 – PROCUREMENT & CONTRACTING REQUIREMENTS 000101 Project Title Page 000107 Seals Page 000115 List of Drawing Sheets 000116 Invitation to Bid 002113 Instructions to Bidders ---------- AIA A701 – 1997, Instructions to Bidders 002213 Supplementary Instructions to Bidders 002513 Prebid Meetings 003119 Existing Condition Information 003132 Geotechnical Data 003143 Permit Application 004113 Bid Form 004322 Unit Prices Form 004323 Alternates Form 006000 Forms 007300 Supplementary Conditions ------------ AIA A101 – 2017, Standard Form of Agreement Between Owner and Contractor, Stipulated Sum. ------------ AIA A201 – 2017, General Conditions of the Contract for Construction.
DIVISION 1 – GENERAL REQUIREMENTS 012000 Unit Prices 012300 Alternates 012500 Substitution Procedures 012600 Contract Modification Procedures 012900 Payment Procedures 013100 Project Management and Coordination 013300 Submittal Procedures 013400 Direct Purchase Procedures 015000 Temporary Facilities and Controls 017300 Execution 017700 Closeout Procedures 017939 Project Record Documents
DIVISION 7 – THERMAL AND MOISTURE PROTECTION 072419 Water Drainage Exterior Insulation and Finish System (EIFS)
DIVISION 8 – OPENINGS 087100 Door Hardware
DIVISION 9 – FINISHES 090000 Finishes
EDUCATION BUILDING ADDENDUM NO. 1 - MAY 9, 2018 GRACE COMMUNITY CHURCH RDSA PROJECT NO. D-17-04
F:\Active\Design\D-17-04 Grace Community\D-17-04 Dwgs\revit\Grace Community Church_SND.rvt
GENERAL INFORMATION G-2
2
A-5
1
ROOM
1
COMMON ABBREVIATIONS
GENERAL NOTESCOMMON SYMBOLS WIND LOADS
DRAWING INDEX
A
NOTES:
1. REFER TO STRUCTURAL FOR WIND LOADS.2. FLORIDA PRODUCT APPROVAL REQUIRED FOR EXTERIOR DOORS, DOOR FRAMES, WINDOWS, STOREFRONTS, COMPONENTS AND CLADDING PER FLORIDA BUILDING CODE - BUILDING -SIXTH EDITION (2017). REFER TO DOOR AND WINDOW SCHEDULES FOR PRODUCT APPROVAL NUMBERS FOR BASIS OF DESIGN PRODUCTS.
1
2
3
4 A-8
6A-7
DOOR SYMBOL - REFER TODOOR SCHEDULE
WINDOW SYMBOL - REFERTO WINDOW SCHEDULE
WALL TYPE SYMBOL -REFER TO WALL SECTIONS
REVISION NOTE
ROOM NAME
DETAIL NUMBER
SHEET DETAIL IS DRAWN
SECTION NUMBER
SHEET SECTION IS DRAWN
INTERIOR/EXTERIORELEVATION NUMBER
SHEET ELEVATION IS DRAWN
UNIVERSAL ACCESSIBILITY
SYMBOL
REVISION CLOUD
EARTH
AC AIR CONDITIONING
ADJ ADJACENT
A/E ARCHITECT/ENGINEER
AFF ABOVE FINISHED FLOOR
AHJ AUTHORITY HAVING
JURISDICTION
ALUM ALUMINUM
ARCH ARCHITECT
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BOT BOTTOM
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CSK COUNTERSUNK
CT CERAMIC TILE
CUST CUSTODIAL
DBL DOUBLE
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DN DOWN
DOT DEPARTMENT OF
TRANSPORTATION
DR DOOR
DS DOWNSPOUT
DWG DRAWING
E EAST
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
EX EXISTING
EXIST EXISTING
EXT EXTERIOR
EWC ELECTRIC WATER COOLER
FACBC FLORIDA ACCESSIBILITY CODE
FBC FLORIDA BUILDING CODE
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FIN FINISH(ED)
FLR FLOOR
FRP FIBERGLASS REINFORCED
PLASTIC
FS FLOOR SINK
FT FOOT / FEET
LAV LAVATORY
LB POUND
LF LINEAL FOOT / FEET
LWIC LIGHTWEIGHT INSULATING
CONCRETE
MAINT MAINTENANCE
MAX MAXIMUM
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTL METAL
RDSA R. DEAN SCOTT, ARCHITECT
RO ROUGH OPENING
S SOUTH
SCHED SCHEDULE / SCHEDULED
SECT SECTION
SHT SHEET
SIM SIMILAR
SJ SAWN JOINT
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STRUCTSTRUCTURAL
SUSP SUSPENDED
T TREAD
T&G TONGUE AND GROOVE
TEL TELEPHONE
TEMP TEMPERED / TEMPORARY
THK THICK
TJ TOOLED JOINT
TOC TOP OF CURB
TYP TYPICAL
UBCI UNIFORM BUILDING CODE
INSPECTOR
UL UNDERWRITER'S LABORATORY
UNO UNLESS NOTED OTHERWISE
VEST VESTIBULE
W WEST
W/ WITH
WC WATER CLOSET
WD WOOD
WP WORKING POINT
GA GAGE / GAUGE
GALV GALVANIZED
GYP GYPSUM
HC HANDICAPPED ACCESSIBLE
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT / HIGH
HVAC HEATING, VENTILATION AND
AIR CONDITIONING
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
N NORTH
NIC NOT IN CONTRACT
NO NUMBER
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OF OWNER FURNISHED
OFC OFFICE
OI OWNER INSTALLED
OPN'G OPENING
OPP OPPOSITE
PL PLATE
PLAM PLASTIC LAMINATE
PLWD PLYWOOD
PNT PAINT
PR PAIR
QT QUARRY TILE
R RADIUS
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
B
1. SHORING DESIGN, ERECTION, MAINTENANCE AND REMOVAL IS RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING INTEGRITY OF STRUCTURE(S) DURING EXECUTION OF THE WORK.
2. COORDINATE ANY UTILITY OR SERVICES INTERRUPTION IN ADVANCE WITH OWNER.
3. UPON COMPLETION OF WORK, ALL EQUIPMENT, FINISHES, AND SURFACES TO BE THOROUGHLY CLEANED.
4. INTENT IS FOR NEW CONSTRUCTION TO BE PARALLEL AND PERPENDICULAOR TO EXISTING BUILDING. ALL NEW CORNERS TO BE 90 CEGREES UNLESS INDICATED OTHERWISE.
5. DIMENSIONS INDICATED ARE TO FACE OF STUD AT NEW WALLS AND TO FACE OF EXISTING WALLS UNLESS OTHERWISE INDICATED. DIMENSIONS ARE TO CENTER LINE OF COLUMNS AND FACE OF MASONRY AND/OR CONCRETE OPENINGS UNLESS OTHERWISE INDICATED. LOCATIONS OF EXISTING CONSTRUCTION SHALL BE FIELD VERIFIED. DO NOT SCALE DRAWINGS. IF QUESTIONS AND/OR APPARENT CONFLICTS EXIST REQUEST CLARIFICATION OF DIMENSIONS FROM ARCHITECT PRIOR TO PROCEEDING.
NO. SHEET TITLE LATEST DATE
A-22 DOOR AND WINDOW DETAILS 04.27.18
A-23 DOOR AND WINDOW DETAILS 04.27.18
A-24 FINISH SCHEDULE 04.27.18
A-25 MISC DETAILS 05.09.18
S0.1 GENERAL NOTES & DESIGN CRITERIA 04.27.18
S1.0 FOUNDATION & SLAB PLAN 04.27.18
S1.1 TOWER & ROOF FRAMING PLANS 04.27.18
S2.1 SECTIONS & DETAILS 04.27.18
S2.2 SECTIONS & DETAILS 04.27.18
S2.3 SECTIONS & DETAILS 04.27.18
S2.4 TYPICAL METAL STUD DETAILS 04.27.18
M-1 HVAC MECHANICAL FLOOR PLAN 04.27.18
M-2 HVAC MECHANICAL PIPING FLOOR PLAN 04.27.18
M-3 DEMOLITION MECHANICAL FLOOR PLAN 04.27.18
M-4 NEW MECHANICAL FLOOR PLAN 04.27.18
M-5 MECHANICAL DETAILS 04.27.18
M-6 MECHANICAL DETAILS 04.27.18
M-7 MECHANICAL SCHEDULES 04.27.18
M-8 MECHANICAL SPECIFICATIONS 04.27.18
P-1 WASTE PIPING PLAN 04.27.18
P-2 WATER PIPING PLAN 04.27.18
P-3 PLUMBING NOTES/DETAILS 04.27.18
P-4 PLUMBING RISER DIAGRAMS 04.27.18
FP-1 FIRE PROTECTION FLOOR PLAN 04.27.18
FP-2 FIRE PROTECTION DETAILS 04.27.18
FP-3 FIRE PROTECTION SPECIFICATIONS 04.27.18
E-1 ELECTRICAL LEGEND, NOTES AND LIGHTING SCHEDULE 04.27.18
E-2 ELECTRICAL PANEL SCHEDULES 04.27.18
E-3 ELECTRICAL SITE PLAN 04.27.18
E-4 ELECTRICAL DEMOLITION PLAN-EXISTING BUILDING 04.27.18
E-5 ELECTRICAL LIGHTING PLAN-EXISTING BUILDING 04.27.18
E-6 ELECTRICAL POWER PLAN - EXISTING BUILDING 04.27.18
E-7 ELECTRICAL LIGHTING PLAN-ADDITION 04.27.18
E-8 ELECTRICAL POWER PLAN 04.27.18
E-9 ELECTRICAL RISERS & DETAILS 04.27.18
E-10 ELECTRICAL DETAILS 04.27.18
E-11 ELECTRICAL SPECIFICATIONS 04.27.18
E-12 ELECTRICAL SPECIFICATIONS 04.27.18
NO. SHEET TITLE LATEST DATE
G-1 COVER SHEET 04.27.18
G-2 GENERAL INFORMATION 05.09.18
1 OF 4 SURVEY 12.26.17
2 OF 4 SURVEY 12.26.17
3 OF 4 SURVEY 12.26.17
4 OF 4 SURVEY 12.26.17
1 COVER SHEET 12.20.17
2 GENERAL NOTES 12.20.17
3 EXISTING CONDITIONS AND DEMOLITION PLAN 12.20.17
4 GEOMETRY PLAN 12.20.17
5 GRADING AND DRAINAGE PLAN 12.20.17
6 GRADING AND UTILITY PLAN 12.20.17
7 CONSTRUCTION DETAILS 12.20.17
8 CONSTRUCTION DETAILS 12.20.17
9 TRAFFIC CONTROL PLAN 12.20.17
10 STORMWATER POLLUTION PREVENTION PLAN 12.20.17
11 NPDES DETAIL SHEET #1 12.20.17
12 NPDES DETAIL SHEET #2 12.20.17
L-1 TREE PROTECTION / REMOVAL PLAN 12.08.17
L-2 TREE PROTECTION / REMOVAL PLAN 12.08.17
L-3 TREE PROTECTION / REMOVAL PLAN 12.08.17
L-4 LANDSCAPE PLAN 12.08.17
L-5 LANDSCAPE PLAN 12.08.17
L-6 LANDSCAPE PLAN 12.08.17
L-7 LANDSCAPE DETAILS 12.08.17
L-8 IRRIGATION PLAN 12.08.17
L-9 IRRIGATION PLAN 12.08.17
L-10 IRRIGATION DETAILS 12.08.17
A-1 SITE PLAN 04.27.18
A-2 LIFE SAFETY PLAN 04.27.18
A-3 DEMOLITION PLAN - EXISTING BUILDING 04.27.18
A-4 FLOOR PLAN - EDUCATION BUILDING 05.09.18
A-5 FLOOR PLAN - EXISTING BUILDING 04.27.18
A-6 ROOF PLAN - EDUCATION BUILDING 04.27.18
A-7 REFLECTED CEILING PLAN - EDUCATION BUILDING 04.27.18
A-8 REFLECTED CEILING PLAN - EXISTING BUILDING 04.27.18
A-9 EXTERIOR ELEVATIONS 04.27.18
A-10 BUILDING SECTION 04.27.18
A-11 WALL SECTIONS 05.09.18
A-12 WALL SECTIONS 04.27.18
A-13 ENLARGED FLOOR PLAN 04.27.18
A-14 INTERIOR ELEVATIONS 04.27.18
A-15 INTERIOR ELEVATIONS 04.27.18
A-16 CASEWORK DETAILS 04.27.18
A-17 ACCESSIBILITY DETAILS 04.27.18
A-18 DETAILS 04.27.18
A-19 DETAILS 04.27.18
A-20 ROOF DETAILS 04.27.18
A-21 DOOR AND WINDOW SCHEDULES 05.09.18
1
1
1
1
1
1 ADDENDUM NO. 1 SND 05.09.18
FD
FD
FD
FD
FD
589 SFAGE 4
55 SFRESTROOM 2
143 SF
TEACHER'SWORKROOM
182 SF
WOMEN'SRESTROOM
182 SF
MEN'SRESTROOM
770 SFFOYER
1140 SF
CONNECTINGCORRIDOR
398 SFKITCHEN
47 SFPANTRY
46 SFELECTRIC
110 SFSTORAGE 1
2929 SF
YOUTH /FELLOWSHIP
578 SF
SPECIALNEEDS
70 SFRESTROOM 1 380 SF
HALLWAY 1
361 SFHALLWAY 2
15'-6"
4'-8"
11'-7"
93 SF
CHILDREN'SRECEPTION
19'-4"
8'-8" 12'-10" 12'-10"
1 2 3 4 5 6
A
B
F
28'-6"
28'-5"
26'-4"
6'-11"
15'-10"
3'-8"
8'-4"
7'-6"
14'-0"
26'-5"
7'-0"
7'-0"
33'-3"
3'-11"
A-14
1
A-142
1
A-11
3
A-11
4
A-11
2 1
4
3
5
8
10
12
13 14
15
16
24
9
11
20
19 21
22
18
17
23
25 26
28
D
A-15 2
3
4
1
A-14 7
BBBBB
A
A
A
B
B
B
B B B A A A A A A C
79'-3"
124'-9"
A-13
1A-13
3
A-13
2
SOUTH1186 SF
NORTH914 SF
YOUTH420 SF
4TH / 5TH GRADE413 SF
1ST GRADE612 SF
2ND / 3RD GRADE613 SF
1760 SF
K5/1ST/2ND/3RDGRADE
LOCATION FOR FUTURE OPERABLE PARTITION (OPP-5)
FUTURE WALLS AT STACKING AREA
F
A-19
2
A-19
1
6'-11" 74'-4"
35'-0"
19'-9"
4'-8"
22'-5"
21'-7"
11'-11" 11'-0"10'-0" 16'-7" 10'-5" 9'-5" 20'-9"
24'-11"
4'-8"
4'-8"
4'-5"
3'-11"
4'-8"4'-8"6'-9"
5'-1"
3'-3"
3'-6"
15'-2"
7'-10"29
A-19
3
7'-2"
8'-7"
40'-11"
A-18
1
A-14
23'-10" 25'-0" 25'-0"
PORTAL FRAME
PORTAL FRAME
A-19
4
A-19
5
6'-9"
2'-6"
2'-6"
19'-2"
4'-8"17'-2"
4'-8" 17'-2" 4'-8" 11'-6"
4'-8"
8
A-18
9
A-18
K5550 SF
19'-7" 22'-4" 22'-1"
C
E
5'-4"
56 SFJANITOR
38 SFVESTIBULE
578 SFAGE 3
6
2
A-11
2'-1"
26'-10 1/2"
11'-2 1/2"
14'-11 1/2"
5'-10"
20'-4 1/2"
G
H
A-14 4
58 SFSTORAGE 2
1'-10"
15'-6"
1'-10"
A-14
3
6
7
31
3227
30
33
COURTYARD
A-14
8
10'-1"
10'-1"
10'-1"
10'-1"
1S
1C2A
3
1S
1A
1A
2A
1B 3
2S
1S
1A
2B 3
1B
2B
2A
1A
2A
3
1A
1B
2B
3
2B
1C
3
3
3
3
1A
1A
1S
1A
1B
1A
3
3
1A
A-14
9
A-14 5
A-14
1 Sim
A-14
3 Sim
MOTORIZED SCREEN BY
OWNER
10
MOTORIZED SCREEN BY
OWNER
FFE: 0'-0"
FFE: 0'-0"
9'-5" 7'-0" 7'-0" 2'-5"
25'-4"
7'-6" 6'-6" 2'-5"
2
A-12
1
A-12
H H
H H
1
A-10
26'-0"
20'-8"
NORTH HVAC EQUIPMENT YARD
SOUTH HVAC EQUIPMENT YARD
WALLS ALIGN
A-18
5
EQ EQ1'-0"
A-25
1
26'-2"
26'-2 1/2"
2C
15'-4"
1B
2
A-10
11
A-18
27'-10"
11'-0"
PLATFORM BY OWNER
A-14
11
MOTORIZED SCREEN BY OWNER
A-19
5Sim
1A
1A
LIGHT POLE - REFER TO ELECTRICAL
LIGHT POLE - REFER TO ELECTRICAL
SEALED EXPANSION JOINT IN FLOOR TILE
A-19
14
9'-4" 13'-4"
REFRIGERANT LINES - REFER TO MECHANICAL
REFRIGERANT LINES - REFER TO MECHANICAL
EXISTINGNEW
NEW
EXISTING
11'-8" 12'-4" TYPICAL CENTER LINE TO CENTER LINE UON 13'-10" 13'-10" 13'-10" +/- 13'-10"
11'-6"
C LC L
A-25 5
OPP-1
OPP-2
OPP-3
OPP-4
3
3
+/- 2"
REFER TO 10/A-18 FOR CANOPY INTERFACE
249 SFNURSERY 1
269 SFNURSERY 2
32 SF
EXISTINGRESTROOM
524 SF
SOUTHCORRIDOR
A
D D D
D
D
D
1
1
1
DOOR SYMBOL - REFER TO DOOR SCHEDULE
WINDOW SYMBOL - REFER TO WINDOW SCHEDULE
WALL TYPE SYMBOL - REFER TO WALL SECTIONS
EXTERIOR WALL
INTERIOR PARTITION
MASONRY WALL
NOT PART OF WORK AREA
EQUIPMENT PLATFORM ABOVE
CURTAIN - OWNER FURNISHED OWNER INSTALLED
OPERABLE PANEL PARTITION
101
A
1
FLOOR PLAN LEGEND
OPP
GRACE COMMUNITY CHURCHJ A C K S O N V I L L E
T E L E P H O N E
F A C S I M I L E
W E B S I T E
L I C E N S E
F L O R I D A 3 2 2 0 2
9 0 4 - 5 9 8 - 0 0 7 2
9 0 4 - 5 9 8 - 0 4 5 0
W W W . R D E A N S C O T T . C O M
N O . A A C 0 0 0 3 0 2
1 2 6 W . A D A M S S T R E E T S U I T E 6 0 2
:
,
:
:
,
C O P Y R I G H T 2 0 1 8
R . D E A N S C O T T , A R C H I T E C T , I N C .
A L L R I G H T S R E S E R V E D .
T H E S E D R A W I N G S & S P E C I F I C A T I O N S
A R E I N S T R U M E N T S O F S E R V I C E A N D
S H A L L R E M A I N P R O P E R T Y O F
R . D E A N S C O T T , A R C H I T E C T , I N C .
A N D S H A L L N O T B E U S E D
F O R A N Y O T H E R P R O J E C T O R
F O R A N E X T E N S I O N O F T H I S
P R O J E C T W I T H O U T E X P R E S S
W R I T T E N C O N S E N T O F
R . D E A N S C O T T , A R C H I T E C T , I N C .
F:\Active\Design\D-17-04 Grace Community\D-17-04 Dwgs\revit\Grace Community Church_SND.rvt
A-4FLOOR PLAN -
EDUCATION BUILDING
PLAN
W
E
NS
1/8" = 1'-0"1
FLOOR PLAN
1. DIMENSIONS ARE TO FACE OF STUD UNLESS OTHERWISE NOTED.2. CONTACT ARCHITECT FOR CLARIFICATION OF DIMENSIONS. DO NOT SCALE DRAWINGS.3. PROVIDE SOLID BLOCKING IN STUD WALLS WHERE ITEMS ARE INDICATED TO BE ATTACHED TO WALLS.4. FIELD VERIFY ALL DIMENSIONS FOR FABRICATION AND INSTALLATION OF CASEWORK.5. INFILL WINDOW/LOUVER WITH METAL STUDS, UNFACED BATT INSULATION, AND GYPSUM BOTH SIDES. GYPSUM TO ALIGN WITH ADJACENT GYPSUM WALLS.6. OPP-1 THROUGH OPP-4 ARE CF/CI. OPP-5 IS FUTURE. REFER TO BID ALTERNATES.7. REFER TO FINISH SCHEDULE FOR PAINTING INFORMATION.
FLOOR PLAN GENERAL NOTES
1 ADDENDUM NO. 1 SND 05.09.18
FFE0' - 0"
A
TOP OF STEEL EAST18' - 0"
5/8" GYPSUM BOARD OVERMETAL FURRING AT 16" O.C.CONTRACTOR'S OPTION: 6"METAL STUDS CUT IN BETWEENPEMB WALL GIRTS ANDSTRUCTURE AT 16" O.C.
WALL SHEATHING NOTE: PROVIDE 5/8" WALL SHEATHING WITH INTEGRAL AIR BARRIER AND TAPED/SEALED SEAMS PER MANUFACTURER'S GUIDELINES. ZIP SYSTEM OR APPROVED EQUIVALENT.
1
FFE0' - 0"
F
TOP OF STEEL WEST16' - 4"
FIN FLOOR ELEV0' - 0"
PEMB GUTTER AND DOWNSPOUTSYSTEM
PEMB METAL ROOF SYSTEM
GRACE COMMUNITY CHURCHJ A C K S O N V I L L E
T E L E P H O N E
F A C S I M I L E
W E B S I T E
L I C E N S E
F L O R I D A 3 2 2 0 2
9 0 4 - 5 9 8 - 0 0 7 2
9 0 4 - 5 9 8 - 0 4 5 0
W W W . R D E A N S C O T T . C O M
N O . A A C 0 0 0 3 0 2
1 2 6 W . A D A M S S T R E E T S U I T E 6 0 2
:
,
:
:
,
C O P Y R I G H T 2 0 1 8
R . D E A N S C O T T , A R C H I T E C T , I N C .
A L L R I G H T S R E S E R V E D .
T H E S E D R A W I N G S & S P E C I F I C A T I O N S
A R E I N S T R U M E N T S O F S E R V I C E A N D
S H A L L R E M A I N P R O P E R T Y O F
R . D E A N S C O T T , A R C H I T E C T , I N C .
A N D S H A L L N O T B E U S E D
F O R A N Y O T H E R P R O J E C T O R
F O R A N E X T E N S I O N O F T H I S
P R O J E C T W I T H O U T E X P R E S S
W R I T T E N C O N S E N T O F
R . D E A N S C O T T , A R C H I T E C T , I N C .
1. BASIS OF DESIGN FOR ALUMINUM STOREFRONT ENTRANCES: YKK 20D
BASIS OF DESIGN:ALUMINUM ENTRANCES YKK 20D FL#: 8581.1HOLLOW METAL DOORS CECO FLUSH SINGLE FL#: 16355.2
GLAZING NOTES
TI TEMPERED INSULATED GLASSNOTE: DOORS 28 AND THE TWO TYPE H WINDOWS IN EAST WALL OF CONNECTING CORRIDOR TO HAVE 3M THINSULATE 40 -CLEAR WINDOW FILM OR APPROVED EQUIVALENT APPLIED TO THE GLAZING PER MANUFACTURER'S INSTRUCTIONS
TS TEMPERED SINGLE PANE GLASS IG INSULATED GLASS
HARDWARE NOTES
1. REFER TO SPECIFICATIONS2. SET THRESHOLDS AT EXTERIOR DOORS IN FULL BED OF SEALANT
WINDOW NOTES
1. PROVIDE INTEGRAL GRIDS AS SHOWN
BASIS OF DESIGN:ALUMINUM STOREFRONT YKK YES 45 FI FL#: 12926.1FIBERGLASS PELLA IMPERVIA FL#: 12599.2
O P E R A B L E P A N E L P A R T I T I O N STYPEMARK WIDTH HEIGHT THICKNESS WEIGHT
HEADDETAIL
JAMBDETAIL
SILLDETAIL
BASIS OFDESIGN MODEL STC CF/CI FINISH
OPP-1 21'-0" 12'-0" 3 1/2" 14.3 LBS/SF 11/A-19 - - HUFCOR 642 56 CF/CI STRATUS HIGH PERFORMANCEWOVEN FABRIC OR EQUIVALENT
OPP-2 40'-0" 12'-0" 3 1/2" 14.3 LBS/SF 11/A-19 - - HUFCOR 642 56 CF/CI STRATUS HIGH PERFORMANCEWOVEN FABRIC OR EQUIVALENT
OPP-3 28'-0" 10'-0" 3 1/2" 14.3 LBS/SF 11/A-19 - - HUFCOR 642 56 CF/CI STRATUS HIGH PERFORMANCEWOVEN FABRIC OR EQUIVALENT
OPP-4 28'-0" 10'-0" 3 1/2" 14.3 LBS/SF 11/A-19 - - HUFCOR 642 56 CF/CI STRATUS HIGH PERFORMANCEWOVEN FABRIC OR EQUIVALENT
OPP-5 40'-0" 12'-0" 3 1/2" 14.3 LBS/SF 11/A-19 - - HUFCOR 642 56 FUTURE STRATUS HIGH PERFORMANCEWOVEN FABRIC OR EQUIVALENT
OPERABLE PANEL PARTITION NOTES
1. EQUIVALENT PRODUCTS FROM OTHER MANUFACTURERS WILL BE CONSIDERED.2. COORDINATE SUPPORT STRUCTURE WITH PEMB MANUFACTURER.3. REFER TO BID ALTERNATES REGARDING OPP-5.
3
2
1
1 ADDENDUM NO. 1 SND 05.09.18
1
FD
FD
FD
FD
6
D
A-15 2
3
4
1
C
E
K1
K2
K3
K4 K5
K6
K7
K8
K9
K10
K9
K10
K11
FLOOR DRAIN - REFER TO PLUMBING, TYPICAL
REFER TO ELECTRICAL
REFER TO ELECTRICAL
K12
2'-0"
2'-0"
2'-0"
20'-4"
15'-0"
1'-0"
13'-8"
7'-5 1/2"
15'-0"
10'-8 1/2" 14'-3"
21'-5 1/2"
20'-3"
2'-0"
2'-0"
3
A-25
A-25
6
RELOCATED PLAY UNIT LOCATION TO BE VERIFIED IN FIELD BY OWNER
OPTION 1: FORMED ANDPOURED CURB SHALL INCLUDE2 CONTINUOUS #4 REBARSWITH 1/2" EXPANSION JOINTEVERY 20' AND CONTROLJOINTS EVERY 5'. BROOMFINISH.OPTION 2: MACHINEINSTALLED CURB SHALLINCLUDE 2 POUNDS OF LONGFIBERGLASS MESH PER CUBICYARD WITH 1/2" EXPANSIONJOINTS EVERY 20' ANDCONTROL JOINTS EVERY 5'.BROOM FINISH.
8"
POWDER COATED STEEL RAILING
POWDER COATED STEELPICKETS
POWDER COATED STEEL SQUAREPOST WITH POST CAP
6'-0"
4'-0"
NOTE: PROVIDE CANE BOLTS EACH GATE
3'-2" @ PLAYGROUND
4'-0"
4'-0" @ HVAC NOTE: PROVIDE PULL LATCH EACH GATE
GRACE COMMUNITY CHURCHJ A C K S O N V I L L E
T E L E P H O N E
F A C S I M I L E
W E B S I T E
L I C E N S E
F L O R I D A 3 2 2 0 2
9 0 4 - 5 9 8 - 0 0 7 2
9 0 4 - 5 9 8 - 0 4 5 0
W W W . R D E A N S C O T T . C O M
N O . A A C 0 0 0 3 0 2
1 2 6 W . A D A M S S T R E E T S U I T E 6 0 2
:
,
:
:
,
C O P Y R I G H T 2 0 1 8
R . D E A N S C O T T , A R C H I T E C T , I N C .
A L L R I G H T S R E S E R V E D .
T H E S E D R A W I N G S & S P E C I F I C A T I O N S
A R E I N S T R U M E N T S O F S E R V I C E A N D
S H A L L R E M A I N P R O P E R T Y O F
R . D E A N S C O T T , A R C H I T E C T , I N C .
A N D S H A L L N O T B E U S E D
F O R A N Y O T H E R P R O J E C T O R
F O R A N E X T E N S I O N O F T H I S
P R O J E C T W I T H O U T E X P R E S S
W R I T T E N C O N S E N T O F
R . D E A N S C O T T , A R C H I T E C T , I N C .
F:\Active\Design\D-17-04 Grace Community\D-17-04 Dwgs\revit\Grace Community Church_SND.rvt
A-25MISC DETAILS
PLAN
W
E
NS
1/4" = 1'-0"1
ENLARGED KITCHEN PLAN
KITCHEN KEYED NOTES
K1 RESIDENTIAL RANGE/OVEN OF/CI
K2 ELKAY STAINLESS STEEL HAND SINK WITH INTEGRAL SPLASH ANDSELF CLOSING METERING FAUCET WITH WRIST BLADES, MIXING VALVEAND REQUIRED ACCESSORIES CF/CI - REFER TO PLUMBING
K3 ICE MACHINE OF/CI
K4 REACH IN FREEZER OF/CI
K5 REACH IN REFRIGERATOR OF/CI
K6 COFFEE AND/OR TEA BREWERS OF/OI
K7 ELKAY 14-3C18x24-0X 14" DEEP STAINLESS STEEL THREECOMPARTMENT SINK WITH INEGRAL SPLASH, STAINLESS STEEL BULLETFEET, LEVER WASTES, BASKET STRAINERS AND REQUIREDACCESSORIES CF/CI
K8 COUNTERTOP MICROWAVE OVEN OF/OI
K9 ADVANCE TABCO MSLAG STAINLESS STEEL WORK TABLE 2'X7' CF/CI
K10 ADVANCE TABCO MSLAG STAINLESS STEEL WORK TABLE 2'X4' CF/CI