Top Banner
27

Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Dec 16, 2015

Download

Documents

Hillary Hoover
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.
Page 2: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Adapting to people & the environmentAdapting to people & the environment

Page 3: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

System OverviewSystem Overview

• Workspace specific

• Quality illumination

• Personal dimming control

• Occupancy sensors

• Daylight dimming

• Peak load management

• Scheduling/Reporting

Page 4: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Workspace specific lightingWorkspace specific lighting

• One Ergolight per standard workstation

• Positioned directly over work area

• Puts light where it is needed

Page 5: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Standard troffer layout: 26 fixturesStandard troffer layout: 26 fixtures

Page 6: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Workspace specific layout: 13 fixturesWorkspace specific layout: 13 fixtures

Page 7: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Application PhotoApplication Photo

Page 8: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Quality Direct/Indirect LightingQuality Direct/Indirect Lighting

• Center lamp distributes light

upwards, reflects off ceiling

• Provides uniform ambient

light / Softens shadows

• Eliminates cave-like room

appearance

• Outer lamps deliver extra

light on desk-top for

enhanced visibility

• Louvers control glare on

computer screens

Page 9: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Constant up-light in open spacesConstant up-light in open spaces

Personal Dimming Daylight Dimming Occupancy Sensing

Up-light unaffected

Page 10: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Occupancy and daylight sensingOccupancy and daylight sensing

• Overhead sensor location= reliable sensing

• Gradually dims outer lamps to 10% after

time delay

• Holds at 10%, before turning lamps off

• Over 30% energy savings in window-

adjacent locations

• Gradual dimming avoids

sudden changes in levels

• Maintains constant light

level at work plane

Page 11: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Cubicle IlluminanceCubicle Illuminance

Ceiling Height 8’x8’ 8’x10’ 10x10’

8’ 48.5 fc 45.2 fc 35.5 fc

9’ 46.8 fc 44.0 fc 33.4

10’ 44.8 fc 42.3 fc 31.3 fc

11’ 42.3 fc 40.1 fc 29.2 fc

12’ 40.4 fc 38.4 fc 25.2 fc

Workspace Dimensions

Reflectances 80/50/20. Cubicle Walls 5’ @ 50% reflectance. T8 Lamps. LLF .9

Page 12: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Personal Dimming ControlPersonal Dimming Control

• On-screen control panel

• Users select preferred light level

• Ceiling light stays constant

Page 13: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

System-wide managementSystem-wide management

• FM has full control over entire Ergolight network

• Entire network can be gradually dimmed for load shedding

• Events can be scheduled on daily/weekly/monthly basis

Page 14: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Detailed energy reportingDetailed energy reporting

Page 15: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Load shedding and sensor commissioningLoad shedding and sensor commissioning

• Avoid peak demand charges with load shedding• Commission sensors with the click of a mouse

Page 16: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

How it works: The Lighting NetworkHow it works: The Lighting Network

Page 17: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Where the energy savings come fromWhere the energy savings come from

Ene

rgy

Use

7 am Noon7 pm

Page 18: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Where the energy savings come fromWhere the energy savings come from

Ene

rgy

Use

7 am Noon7 pm

Page 19: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Where the energy savings come fromWhere the energy savings come from

Ene

rgy

Use

7 am Noon7 pm

Page 20: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Where the energy savings come fromWhere the energy savings come from

Ene

rgy

Use

7 am Noon7 pm

Page 21: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Where the energy savings come fromWhere the energy savings come from

Ene

rgy

Use

7 am Noon7 pm

Page 22: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Proven results with Ergolight ControlsProven results with Ergolight Controls

Reynolds Metals

87%

(retrofit)

Raytheon

83%

(retrofit)

BC Hydro

78%

(new construction)

Page 23: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Actual 3rd party resultsActual 3rd party results

• BC Hydro – Comparison Study

Weekly Power Profile Comparison – 8th floor (Ergolight) vs. 5 th floor (Reference)

0

1

2

3

4

5

6

7

8

9

Monday Tuesday Wednesday Thursday Friday Saturday Sunday Time (Hour)

Power (kW)

CPP 8 Ergolight CPP5 Open Offices

Page 24: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Light Right Consortium: Albany, NYLight Right Consortium: Albany, NY

• A comprehensive study on worker satisfaction and productivity

Page 25: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

3 aesthetic mounting options3 aesthetic mounting options

Page 26: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.

Other optionsOther options

Available with T8 or T5 lamping

Page 27: Adapting to people & the environment System Overview Workspace specific Quality illumination Personal dimming control Occupancy sensors Daylight dimming.