8/12/2019 ACCESS Housekeeping
1/12
PMR IMPLEMENTATION
ACCESS - PMR Implementation1. Antenna System Checking c/o SNC
Determine condition of TX/RX antenna & feeder cable throughsweep testing.
VSWR value = 1.5
2. BTS Health Check (re-commissioning) c/o SNC TRX loop testing
Diversity testing
Other PIU testing (Duplexer, Multi-coupler, combiner cooling fanetc.)
Checking of loose connector & cabling
Antenna Mechanical Tilt = from audit data
Antenna Orientation = from audit data
8/12/2019 ACCESS Housekeeping
2/12
PMR IMPLEMENTATION
ACCESS - PMR Implementation3. Basic Parameter checking through CDD c/o SNC,
NSA & Access
TRX Frequency MBCCH/TCH
Hopping Parameter MAL list
GTRX
GENA
EGENA
CDED
CDEF
ADCE
8/12/2019 ACCESS Housekeeping
3/12
PMR IMPLEMENTATION
ACCESS - PMR ImplementationBTS KPI
http://localhost/var/www/apps/conversion/tmp/scratch_7/Eng08-May-2007.xlshttp://localhost/var/www/apps/conversion/tmp/scratch_7/Eng08-May-2007.xls8/12/2019 ACCESS Housekeeping
4/12
PMR IMPLEMENTATION
ACCESS BSC - PMR ImplementationBSC OVERLOAD PROTECTION:
0.4 Signalling link load
80% Ater Utilization (average)
80% TRX Utilization (average)
80% CPU Load (average)
90% Gb link load (average)
BTS REHOMING CONSIDERATION: Ater utilization of target BSC < 80%
Paging load of target BSC < 150000 pages (assuming 1
LAC per BSC) Signaling link load of target BSC < 0.4
CPU load of target BSC < 80%
Gb link load of target BSC < 90%
Gb link license (GPRS/EDGE) must be updated
VLR of target homing MSC < 85%
8/12/2019 ACCESS Housekeeping
5/12
PMR IMPLEMENTATION
BSC Health Check c/o BSS Opti
Printing of Alarm History (for the past 24 hrs)
Printing of Current Alarms
Checking working states of PIUs
Checking of TRX Channel
Interrogate Circuit Checking of Signaling
Checking of Network Configuration
Unit diagnostics and HW Switchover
8/12/2019 ACCESS Housekeeping
6/12
PMR IMPLEMENTATION
ACCESS BSC - PMR ImplementationBSC2i Traffic Handling Capacity:
BSC2i configured with 512 full rate TRXs,circuit switched:
512 TRXs (64 TRX per BCSU)
248 BCFs (31 BCFs per BCSU) 512 BTSs (64 BTSs per BCSU)
6144 SDCCHs (768 SDCCHs per BCSU)
4096 TCHs (512 TCHs per BCSU)
3040 Erlangs total traffic handling capacity(max of 26 aters)
2 x 128 kbps (max signaling link per bcsu)
8/12/2019 ACCESS Housekeeping
7/12
PMR IMPLEMENTATION
ACCESS BSC - PMR ImplementationBSC3i Traffic Handling Capacity:
BSC3i is configured with 660 full rate TRXs,circuit switched:
660 TRXs (110 TRX per BCSU)
660 BCFs (110 BCFs per BCSU) 660 BTSs (110 BTSs per BCSU)
10560 SDCCHs (1760 SDCCHs per BCSU)
5280 TCHs (880 TCHs per BCSU)
3920 Erlangs total traffic handling capacity(max of 33 aters)
2 x 256 kbps (max signaling link per bcsu)
8/12/2019 ACCESS Housekeeping
8/12
PMR IMPLEMENTATION
8/12/2019 ACCESS Housekeeping
9/12
PMR IMPLEMENTATION
8/12/2019 ACCESS Housekeeping
10/12
PMR IMPLEMENTATION
8/12/2019 ACCESS Housekeeping
11/12
PMR IMPLEMENTATION
8/12/2019 ACCESS Housekeeping
12/12
PMR IMPLEMENTATION