Top Banner
AC890PX High Power Inverter
34

AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

May 22, 2018

Download

Documents

lycong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

AC890PX High Power Inverter

Page 2: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

The history of SSD LINK 1989-1996

• LINK 1 was the first fiber optic peer-to-peer network of its kind.

• Its sole purpose was to control a coordinated drive system.

• Used primarily with the 570L DC Link drive and later, the 590L and much later, the 620L AC vector Link drive.

• With speeds of 2.7MB, and all modules communicating at the same time, it was blazing fast for its time.

• Fiber optic cable was thin, light, and was not plagued with electrical noise issues. A single loop of fiber, linking drive to drive was the only signal connection required for a coordinated system.

Page 3: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

The history of SSD LINK 1989-1996

• There were Link 1 modules for digital and analog I/O, serial communication and processor modules that provided memory to hold function blocks. (570L, 590L drives had no function block memory)

• A one-page CRT Link touchscreen provided operator input and monitoring.

• ConfigEd and SAM software suite was used to program all components and monitor their performance on-line.

Page 4: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

A typical LINK 1 system

DIAGNOSTICS

SPEED DEMAND

E

M

Local

Prog Jog

Health

Run

Brake

Local

EUROTHERM

DRIVES

620 VECTOR LINK

SERIES

PLC

590L 620LProcessor

Analog I/O Digital I/OGateway

Repeater

CRT

Touchscreens

Gateway

Page 5: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

The history of 1996-2014

• A Link techbox was designed to fit into a standard drive, allowing it to be used as a Link drive. No more special Link drive.

• Link 2 started to consolidate the highly distributed control of LINK 1,

with the introduction of the LinkRack and LinkScreen

• Individual LINK 1 modules that needed their own 24V supply and RTN

cards were replaced by a Link rack that would fit up to 3 I/O cards and 1 RTN card.

• Racks could hold a communication card to talk directly to a PLC. No more gateway module, no more gateway repeater.

LINK

Page 6: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

The history of 1996-2014

• The touchscreen was now LCD based, and could be configured with multiple pages of screens. It also doubled-up as a rack.

• Racks and screens were powered by 120VAC, eliminating large 24VDC power supplies used in LINK 1 systems.

• Both the rack and screen had enough memory and storage to hold a 6-section drive system configuration.

• DSD software now had the monitoring part built-in. No more separate packages for designing and set-up/monitoring.

LINK

Page 7: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

A typical LINK system

PLC

590+

Analog I/O

Digital I/O

Link Rack

690+

L L

LCD

Touchscreen

Analog I/O

Digital I/O

Page 8: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net
Page 9: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

Introducing

• LINKnet is an Ethernet based modern version of our SSD LINK fiber optic system. CAT-6 cables replace fiber. No more repeaters.

• It caters to existing LINK customers whose fiber optic systems are several years old, and in need of modernization.

• A LINKnet techbox that fits in the same spot as the LINK techbox on 590+ and 690+ drives.

2014

Page 10: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

Introducing

• Customers get to keep their panels, 590+ and 690+ drives, and change out only the techbox and the fiber optic network.

• Huge savings for the customer, resulting in future business.

• Link I/O will be replaced by Ethernet remote I/O modules.

• Any Link touchscreens will be replaced by TS8000 in phase 1.

• It is the new peer-to-peer network for 590+ and 690+ drive systems.

2014

Page 11: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

New LINKnet Hardware

LINKnet HMI

Ethernet peer to peer

support & Modbus TCP/IP

fieldbus

Phase III(December 2015?)

LINKnet 890 Option Card

with Ethernet

Peer to Peer Support &

Modbus TCP/IP fieldbus

Phase II(March 2015)

Phase I(May 2014)

LINKnet Tech. Box

with Ethernet

Peer to Peer Support &

Modbus TCP/IP fieldbus

+ Remote I/O support

Page 12: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

LINKnet Techbox

Mini USB

programming

port

Ethernet RJ-45

peer-to-peer

port

Reserved

Do not use

External power

24VDC

(not essential)

6055-LNET-00-00590+ all frames

690+ frames C-K

6053-LNET-00-00690+ frame B only

6057-LNET-00-00Din rail mounted for

extra processing

Page 13: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

Current Peer to Peer Support

TS8000590+ 690+ L5392 L5300

LINKfiber optic

690+

PLC

FireWire

TS8000

L5300 PLCAC890 AC890AC890

Page 14: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

Future Peer to Peer Support

LINKnet DC590+ AC690+

TS8000AC890 AC890

3rd Party

HMI3rd Party

Remote I/O

Modbus TCP/IP

Modbus

TCP

PLC

Page 15: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

I/O support

Page 16: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

Modular Input and Output Modules

A node can consist of a combination of analog, digital, and specialty I/O modules, with

different potentials and signals (up to 230VAC). Up to 64 I/O modules* can be inserted in a

node.

* System can support up to 250 I/O modules with Bus Extension modules.

• Over 400 different I/O modules

• Digital Inputs & Outputs5-240 VDC & 24 - 230 VAC

(1, 2, 4, 8 & 16 Channel Devices)

• Analog Inputs & Outputs0-10 V, +/-10 V, 4-20 ma, thermocouple, RTD; 3

PH power measure. (differ. & single ended)

• Specialty ModulesCounters, encoders, serial interface (RS232 &

RS485), AS Interface, Vibration, DC Drive

Page 17: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

Bus Extension Modules

Bus Extension Modules make panel layout flexible.

• Max. no. of I/O

modules: 250

• Max. no. of bus

extensions: 10

• Cable length: 5m

• Cable: STP-cable

with RJ45 (straight

through cable)

Page 18: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

DSE programming & on-line Software

Page 19: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

ConfigEd / DSD > DSE highlights

• DSE replaces ConfigEd, SAM and DSD as the software tool for both designing and on-line use. Version 3.00 or later supports LINKnet.

• Newer platform, compatible with Windows XP, 7, 8, 32/64 bit.

• Newer features like remote IP address access.

• More intuitive interface, with icons for frequently used features.

• Monitoring and Charting of any parameter from any address.

• Several other ease-of-use improvements.

Page 20: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

LINKnet - DSE advantages

• No more -100 to + 100% limitation, as in LINK 1 and 2.

• No more 83.33% scaling for speed signals.

• No more 50% scaling for torque and current signals.

• Easy setup and mapping for I/O and communication cards.

• Update on-line from within DSE. No more Manger

• Import/export projects from inside DSE. No more Manager.

Page 21: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

DSE packages

• DSE Development is the designer’s package. It creates and manages projects and configurations of entire lines.

• DSE Runtime is the maintenance package. It has full editing rights, same as DSE Development, but it cannot be used to program new projects or new modules.

• If you have ConfigEd or DSD, you will need to purchase the equivalent DSE package.

• If you have DSE already, there is no charge. Just update to version 3.00 or later by checking for updates from within DSE.

Page 22: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

Read and write directly to Ethernet I/O

Page 23: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

Read and write directly to PLC or HMI

Page 24: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

Mapping PLC and HMI I/O

Page 25: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

Access drive parameters by Tag number

Page 26: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

Network Diagnostics

• System Control block now monitors Ethernet network integrity

• System Control block now monitors TB to drive comms

• All these outputs can be actioned as desired or displayed on HMI

Ethernet comms

TB to drive comms

Page 27: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

Retrofit plan

Page 28: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

Upgrade scope

When trying to specify an upgrade for an existing LINK line, use the following guidelines:

• Is it a LINK 1 system or a LINK 2 system?

• How many drive sections?

• How many locations/enclosures?

• How many points of analog and digital I/O?

• Where is the I/O distributed?

• How many touchscreens? How many total pages?

• How much extra processing in various modules?

• Any fieldbus communication present?

Page 29: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

LINK 1 to LINKnet

Is it a LINK 1 system or a LINK 2 system? LINK 1

How many drive sections? 1 DC, 2 AC (new drives)

How many locations/enclosures? 3

How many points of analog and digital I/O? Analog 4+1, Digital 6+4

Where is the I/O distributed? 1 location

How many touchscreens? How many total pages? 3 screens, 3 pages, no proc.

How much extra processing in various modules? 1 page

Any fieldbus communication present? Ethernet

DIAGNOSTICS

SPEED

DEMAND

E

M

Local

Prog Jog

He

alt

hR

u

nB

ra

keLo

cal

EUROTHERM

DRIVES

620 VECTOR LINKSERIES

PLC

590L 620LProcessor

Digital I/OGateway

Repeater

CRT

Touchscreens

Gateway

DIAGNOSTICS

SPEED

DEMAND

E

M

Local

Prog Jog

He

alt

hR

u

nB

ra

keLo

cal

EUROTHERM

DRIVES

620 VECTOR LINKSERIES

620L

Analog I/O

LINK 1

Fiber optic

1 page

1 DC drive 2 AC drives

4 in, 1 out

6 in, 4 out

3 screens1 page each

Ethernet PLC

Page 30: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

LINK 1 to LINKnet solutionDIAGNOSTICS

SPEED

DEMAND

E

M

Local

Prog Jog

He

alt

hR

u

nB

ra

keLo

cal

EUROTHERM

DRIVES

620 VECTOR LINKSERIES

PLC

590L 620LProcessor

Digital I/OGateway

Repeater

CRT

Touchscreens

Gateway

DIAGNOSTICS

SPEED

DEMAND

E

M

Local

Prog Jog

He

alt

hR

u

nB

ra

keLo

cal

EUROTHERM

DRIVES

620 VECTOR LINKSERIES

620L

Analog I/O

LINK 1

Fiber optic

590+ 690+690+

TS8000Remote I/O

Protocol

converter *

E-Switch

LINKnet

EthernetModbus

TCP

PLC

Page 31: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

LINK to LINKnet

Is it a LINK 1 system or a LINK 2 system? LINK 2

How many drive sections? 1 DC, 2 AC (same drives)

How many locations/enclosures? 3

How many points of analog and digital I/O? Analog 4+1, Digital 6+4

Where is the I/O distributed? 1 location

How many touchscreens? How many total pages? 1 screen, 3 pages, 3 proc.

How many Racks? 1 rack, 4 processing pages.

How much extra processing in various modules? 3+4 pages

Any fieldbus communication present? Ethernet

590+ 690+ L5392 L5300

LINKfiber optic

690+

PLC

1 page

1 DC drive 2 AC drives

1 screen3 pages3 pages

processing

Ethernet PLC

Dig. 6 in, 4 outAna. 4 in, 1 out

Comms: Ethernet4 pages processing

Page 32: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

LINK to LINKnet solution

590+ 690+ L5392 L5300

LINKfiber optic

690+

PLC

590+ 690+690+

TS8000Remote I/O

Modbus

TCP

PLCE-Switch

LINKnet

Ethernet

Page 33: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

• SSD Drives has over 1200 LINK systems in the field. There are many more designed by our Integrators.

• Most are ripe for modernization.

• LINKnet opens the door to:

• Sales opportunities

• Modern Ethernet network

• Same look and feel for the Customer

• Easier integration with PLC and I/O

• Customer retention

Upgrade opportunities

Page 34: AC890PX High Power Inverter - SDS Drives · 620 VECTOR LINK SERIES PLC ... • Individual LINK 1 modules that needed their own 24V supply and RTN ... New LINK net Hardware LINK net

Thank You!