GAPTEC-Electronic GmbH & Co. KG [email protected] – www.gaptec-electronic.com Page 1 of 5 3ACA_3 – Rev. 2017-1.4 Specifications subject to change without notice. 3ACA_3R Series 3W - Single Output AC-DC Converter - Universal Input - Isolated & Regulated AC-DC Converter 3 Watt The 3ACA_3 series is a compact size power converter series offered by Gaptec. It features universal input voltage, taking both DC and AC input voltage, low power consumption, high efficiency, high reliability, safer isolation. It offers good EMC performance, and is UL & CE certified, and widely used in industrial, electricity, instruments, telecommunication and civil applications. Universal input: 85~264VAC/100~370VDC AC and DC dual-use (input from the same terminal) High efficiency Operating temperature: -20°C~+70°C High power density Output over voltage protection Short circuit protection (SCP) Over temperature protection Meets EN60950, UL60950 Output specifications Voltage accuracy ±2% ±3% at 3.3V output Line regulation (full load) ±0.5% (typ) Load regulation (10% to 100%) ±1% (typ) Ripple & Noise (p-p) 20MHz Bandwidth: 50mV (typ), 100mV (max) Short circuit protection Continuous, self-recovery Temperature Drift Coefficient ±0.02%/°C (typ) Stand-by Power Consumption 0.3W (typ) Over-current Protection ≥110% Io self-recovery Over-voltage Protection • 3.3/5VDC output: ≤7.5VDC • 9VDC output: ≤12VDC • 12/15VDC output: ≤20VDC • 24VDC output: ≤30VDC Min. load 1% (min) Power-off Holding Time 230VAC input: 50ms * Parallel line test method is adopted to test the ripple and noise, please see AC-DC Converter Application Notes for specific operation methods. Input specifications Input voltage range 85~264VAC, 100~370VDC Input frequency 47~63Hz Input current 110VAC • 65mA (typ) 230VAC • 30mA (typ) Inrush current 110VAC • 10A (typ) 230VAC • 20A (typ) Leakage current 0.1mA RMS typ. 230VAC/50Hz Recommended External Input Fuse • 1A/250V • Slow-fusing Hot plug Unavailable Example: 3ACA_05S3R 3 = 3Watt; AC = AC-DC; A = case style; 5Vout; S = single output; 3 = 3kVAC; R = revised model Note: 1. Unless otherwise specified, data in this datasheet should be tested under the conditions of Ta = 25°C, humidity<75% when inputting nominal voltage and outputting rated load; 3. All index testing methods in this datasheet are based on our Company’s corporate standards; 4. The performance indexes of the product models listed in this manual are as above, but some indexes of non-standard model products will exceed the above-mentioned requirements, and please directly contact our technician for specific information; 5. We can provide product customization service; 6. The product specification may be changed at any time without prior notice. Approval Model Package Power [W] Output [Vo] Output [lo] Ripple and Noise [mV, typ] Efficiency [%, typ] Capacitive load [µF, max] UL/CE 3ACA_03S3R 37 x 24.50 x 18 mm 2.3 3.3V 700mA 50 66 6000 UL/CE 3ACA_05S3R 37 x 24.50 x 18 mm 3 5V 600mA 50 74 6000 UL/CE 3ACA_09S3R 37 x 24.50 x 18 mm 3 9V 330mA 50 75 1500 UL/CE 3ACA_12S3R 37 x 24.50 x 18 mm 3 12V 250mA 50 77 1500 UL/CE 3ACA_15S3R 37 x 24.50 x 18 mm 3 15V 200mA 50 77 1000 UL/CE 3ACA_24S3R 37 x 24.50 x 18 mm 3 24V 125mA 50 78 330
5
Embed
AC-DC Converter 3 Watt...3ACA_3R Series 3W - Single Output AC-DC Converter - Universal Input - Isolated Regulated AC-DC Converter 3 Watt The 3ACA_3 series is a compact size power converter
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
GAPTEC-Electronic GmbH & Co. KG [email protected] – www.gaptec-electronic.com
AC-DC Converter 3 WattThe 3ACA_3 series is a compact size power converter series offered by Gaptec. It features universal input voltage, taking both DC and AC input voltage, low power consumption, high efficiency, high reliability, safer isolation. It offers good EMC performance, and is UL & CE certified, and widely used in industrial, electricity, instruments, telecommunication and civil applications.
Universal input: 85~264VAC/100~370VDCAC and DC dual-use (input from the same terminal)High efficiencyOperating temperature: -20°C~+70°C
High power densityOutput over voltage protectionShort circuit protection (SCP)Over temperature protectionMeets EN60950, UL60950
* Parallel line test method is adopted to test the ripple and noise, please see AC-DC Converter Application Notes for specific operation methods.
Input specifications
Input voltage range 85~264VAC, 100~370VDC
Input frequency 47~63Hz
Input current 110VAC• 65mA (typ)
230VAC• 30mA (typ)
Inrush current 110VAC• 10A (typ)
230VAC• 20A (typ)
Leakage current 0.1mA RMS typ. 230VAC/50Hz
Recommended External Input Fuse
• 1A/250V • Slow-fusing
Hot plug Unavailable
Example:3ACA_05S3R3 = 3Watt; AC = AC-DC; A = case style; 5Vout; S = single output; 3 = 3kVAC; R = revised model
Note:1. Unless otherwise specified, data in this datasheet should be tested under the
conditions of Ta = 25°C, humidity<75% when inputting nominal voltage and outputting rated load;
3. All index testing methods in this datasheet are based on our Company’s corporate standards;
4. The performance indexes of the product models listed in this manual are as above, but some indexes of non-standard model products will exceed the above-mentioned requirements, and please directly contact our technician for specific information;
5. We can provide product customization service;6. The product specification may be changed at any time without prior notice.
Approval Model Package Power [W]
Output [Vo]
Output [lo]
Ripple and Noise [mV, typ]
Efficiency [%, typ]
Capacitive load [µF, max]
UL/CE 3ACA_03S3R 37 x 24.50 x 18 mm 2.3 3.3V 700mA 50 66 6000
UL/CE 3ACA_05S3R 37 x 24.50 x 18 mm 3 5V 600mA 50 74 6000
UL/CE 3ACA_09S3R 37 x 24.50 x 18 mm 3 9V 330mA 50 75 1500
UL/CE 3ACA_12S3R 37 x 24.50 x 18 mm 3 12V 250mA 50 77 1500
UL/CE 3ACA_15S3R 37 x 24.50 x 18 mm 3 15V 200mA 50 77 1000
UL/CE 3ACA_24S3R 37 x 24.50 x 18 mm 3 24V 125mA 50 78 330
GAPTEC-Electronic GmbH & Co. KG [email protected] – www.gaptec-electronic.com
EMC / EMI / PFM IEC/EN61000-4-8 10A/m perf. Criteria A
EMC / EMI / Voltage dips, short andinterruptions immunity
IEC/EN61000-4-11 0%-70% perf. Criteria B
Safety standards IEC60950, EN60950, UL60950
Safety approvals EN60950, UL60950
Safety class CLASS II
Case material UL94V-0
MTBF MIL-HDBK-217F@25°C: >300,000h
Weight 25g
Note: ①Input voltage should be derated based on temperature derating when it is 85~100VAC/240~264VAC/100~120VDC/340~370VDC;②This product is suitable for use in natural air cooling environments, if in a closed environment, please contact our company’s FAE.
GAPTEC-Electronic GmbH & Co. KG [email protected] – www.gaptec-electronic.com
Note:Output filtering capacitor C2 is electrolytic capacitor, it is recommended to apply electrolytic capacitor with high frequency and low resistance. For capacitance and current of capacitor please refer to manufacture’s datasheet. Capacitance withstand voltage derating should be 80% or above. C1 is ceramic capacitor, which is used to filter high-frequency noise. External input MOV1 is recommended to use S14K350. TVS is a recommended component to protect post-circuits if converter fails.
3ACA_024S33ACA_12S33ACA_05S3
3ACA_024S33ACA_12S33ACA_05S3
EMC solution-recommended circuit
EMC application circuit with higher requirements
GAPTEC-Electronic GmbH & Co. KG [email protected] – www.gaptec-electronic.com