A 2 Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote I/O Paperless Recording System PC Recorder Electronic Actuators & Position Sensors Lightning Surge Protectors Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1 Mini-M Series Mini-MW Series M6 Series M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT Series K-UNIT Series F-UNIT Series H-UNIT Series 10-RACK Series 18-RACK Series 38-RACK Series Rack-mounted A Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote I/O Paperless Recording System PC Recorder Electronic Actuators & Position Sensors Lightning Surge Protectors 3 Mini-M Series Mini-MW Series M6 Series M5-UNIT Series W5-UNIT Series M3-UNIT Series M3S-UNIT Series Pico-M Series MX-UNIT Series M-UNIT Series W-UNIT Series K-UNIT Series F-UNIT Series H-UNIT Series 10-RACK Series 18-RACK Series 38-RACK Series Rack-mounted Specifications are subject to change without notice. ISP1-1 Four-wire Signal Conditioners Four-wire Signal Conditioners Four-wire Signal Conditioners Product Selection Guide Four-wire Product Selection Guide Four-wire Product Selection Guide mm (inch) Compact Plug-in Mini-M Series Compact Plug-in Signal Splitters Mini-MW Series Ultra-Slim M6 Series Low Profile M5-UNIT Series Low Profile Signal Splitters W5-UNIT Series Thin Profile M3-UNIT Series Thin Profile M3S-UNIT Series P.8 P.30 P.38 P.56 P.60 P.64 P.68 Construction Plug-in Plug-in Ultra-slim Terminal block Terminal block Front terminal access Front terminal access Connection M3 screw terminal M3 screw terminal Tension-clamp, M3 screw terminal Euro terminal M3.5 screw terminal Input: M3.5 screw terminal Output & power: M3 screw terminal Removable terminal block Removable terminal block Isolation Three ways Four ways Three / four ways Three ways Four ways Three ways Three / Four ways Dielectric Strength 2000V AC 2000V AC 2000V AC DC powered: 2000V AC AC powered: 1500V AC 2000V AC DC powered: 1000V AC AC powered: 1500V AC (M3LU) 2000V AC Range Selectability Specified when ordering or PC / One-Step Cal programming Specified when ordering or PC programming Specified when ordering or PC programming Specified when ordering Specified when ordering or DIP switch programming PC / One-Step Cal programming Specified when ordering or PC programming Dual Output – Yes Selected models – Yes – Selected models Power Input AC / DC AC / DC DC AC / DC AC / DC AC / DC AC / DC (universal) Operating Temperature -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -20 to +55°C (-4 to +131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -25 to +65°C (-13 to +149°F) -10 to +55°C (14 to 131°F) Mounting Surface or DIN rail Surface or DIN rail DIN rail DIN rail DIN rail DIN rail DIN rail Dimensions W23 [29.5] × H76 × D124 mm (0.91” [1.16”] × 2.99” × 4.88”) W29.5 × H89 × D124 mm (1.16” × 3.51” × 4.88”) M6D/S: W5.9 × H94 × D102 mm (0.23” × 3.70” × 4.02”) M6N: W7.5 × H102 × D102 mm (0.30” × 4.02” × 4.02”) W25 × H97 × D41 mm (0.98” × 3.82” × 1.61”) W45 × H97 × D41 mm (1.77” × 3.82” × 1.61”) W18 × H106 × D110.5 mm (0.71” × 4.17” × 4.35”) W12 × H106 × D110.5 mm (0.47” × 4.17” × 4.35”) Standards & Approvals CE / UL / C-UL CE / UL / C-UL CE (UL / C-UL pending) CE CE CE / UL / C-UL (DC powered only) CE Mini-M Series Mini-MW Series M6 Series M5-UNIT W5-UNIT M3-UNIT M3S-UNIT Input Loop Powered Isolator M2SN – M6xSN M5SN – – – Universal Input M2XU, M2XUM – – – – M3LU – DC Input M2XV2, M2LV, M2VS, M2VF, M2VF2, M2VV W2VS, W2VF M6xYV, M6xXV, M6xVS, M6xWVS M5VS, M5MV, M5VF W5VS, W5FV M3LV M3SYV, M3SXV, M3SVS, M3SWVS High Current Output – – – – – – – Thermocouple Input M2XT2, M2TS W2TS M6xXT M5TS W5TS M3LT M3SXT RTD Input M2XR2, M2LR, M2RS, M2RR W2XR, W2RS M6xXR M5RS W5RS M3LR M3SXR, M3SRS Potentiometer Input M2XM2, M2LPM, M2MS W2XM, W2MS M6xXM M5MS W5MS M3LM M3SXM, M3SMS Current Loop Supply M2D, M2D2, M2DYS, M2DY, M2DL, M2DNY, M2DYH, M2DU W2DYS, W2DY, W2DNY, W2DYH M6xDY M5DY W5DY M3LDY, M3DY M3SDY Self-Synch Input – – – – – – – Strain Gauge Input M2LCS – – – W5LCS M3LLC – AC Input M2TG, M2AC W2TG, W2AC – – – – – PT Input M2PA, M2PE W2PA, W2PE – M5PT – – – CT Input M2CA, M2CE, M2CEC W2CA, W2CE M6xCTC M5CT, M5CTC – – – Power Transducer – – – – – – – Frequency Input M2XPA3, M2XPA2, M2SP W2SP M6xPA M5PA W5PA M3LPA – Encoder Input M2XRP2 – – – – – – Frequency Output M2AP W2AP – – – – – Pulse Isolator M2PP W2PP – – – – – Pulse Scaler M2PRU – – – – – – P/I Transducer M2PV W2PV – – – – – I/P Transducer – – – – – – – Limit Alarm M2AVS, M2SED, M2AS, M2AS1 – M6xXAS – – – – BCD Transducer – – – – – – – Math Function M2ADS, M2SBS, M2MLS, M2DIS – M6xXF2 – – – – Ratio/Bias M2REB, M2RTS – – – – – – Process Function M2XF2, M2FL, M2FLS, M2LMS, M2UDS2, M2UDS – M6xXF1 – – – – Filter/Lag M2CDS, M2CRS – M6xXF1 – – – – Hold M2AMS2, M2AMS, M2PHS2, M2PHS – M6xXF3 – – – – Signal Selector M2SES2, M2SES, M2MNV – M6xXF2 – – – – Signal Generator M2MST – – – – – – Valve Positioner – – – – – – – Control Backup – – – – – – – Others – – – – – – – Four-wire Signal Conditioners Product Selection Guide
10
Embed
A Four-wire Signal Conditioners Product Selection Guide ... · Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Limit Alarms Gateway, Remote
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
A
2
Four-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors Lightning Surge Protectors
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1
Mini-M Series
Mini-MW Series
M6 Series
M5-UNIT Series
W5-UNIT Series
M3-UNIT Series
M3S-UNIT Series
Pico-M Series
MX-UNIT Series
M-UNIT Series
W-UNIT Series
K-UNIT Series
F-UNIT Series
H-UNIT Series
10-RACK Series
18-RACK Series
38-RACK Series Rack
-mou
nted
AFour-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors
Lightning Surge Protectors
3
Mini-M Series
Mini-MW Series
M6 Series
M5-UNIT Series
W5-UNIT Series
M3-UNIT Series
M3S-UNIT Series
Pico-M Series
MX-UNIT Series
M-UNIT Series
W-UNIT Series
K-UNIT Series
F-UNIT Series
H-UNIT Series
10-RACK Series
18-RACK Series
38-RACK SeriesRack
-mou
nted
Specifications are subject to change without notice.ISP1-1
Four
-wire
Sig
nal C
ondi
tione
rs
Four
-wire
Sig
nal C
ondi
tione
rs
Four-wire Signal Conditioners Product Selection Guide
Four-wire Product Selection Guide
Four-wire Product Selection Guide
mm (inch)
Compact Plug-in Mini-M Series
Compact Plug-in Signal Splitters Mini-MW Series
Ultra-Slim M6 Series
Low Profile M5-UNIT Series
Low Profile Signal Splitters W5-UNIT Series
Thin Profile M3-UNIT Series
Thin Profile M3S-UNIT Series
P.8 P.30 P.38 P.56 P.60 P.64 P.68
Construction Plug-in Plug-in Ultra-slim Terminal block Terminal block Front terminal access Front terminal access
Power Input AC / DC AC / DC DC AC / DC AC / DC AC / DC AC / DC (universal)
Operating Temperature -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -20 to +55°C (-4 to +131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -25 to +65°C (-13 to +149°F) -10 to +55°C (14 to 131°F)
Mounting Surface or DIN rail Surface or DIN rail DIN rail DIN rail DIN rail DIN rail DIN rail
Isolation Four ways Three ways Three ways Four ways Three / four ways Three ways Three ways
Dielectric Strength 1500V AC 2000V AC 2000V AC 2000V AC 2000V AC 1000V AC 500V AC
Range Selectability Specified when ordering or PC programming Front key programming Specified when ordering or
PC / Programming unit programmingSpecified when ordering or
PC / Programming unit programming Specified when ordering Specified when ordering or PC / Programming unit programming
Specified when ordering or PC / Programming unit programming
Dual Output Yes – – Yes Selected models – –
Power Input AC / DC AC / DC AC / DC AC / DC AC / DC AC / DC DC
Operating Temperature 0 to 55°C (32 to 131°F) -5 to +55°C (23 to 131°F) -5 to +60°C (23 to 140°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F) -5 to +55°C (23 to 131°F)
Mounting Installation Base (Surface) Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail
Four-wire Signal Conditioners Product Selection Guide
n PC Configurator SoftwareM-System’s PC Configurator programs are packed with advanced features. Not only the I/O ranging, but also linearization, fine calibration, filters, diagnostics are available depending on the signal conditioner’s function. In addition, many configurators are provided with monitoring and simulating functions to help you confirm the module’s proper operation, calibrate it at the field site and commissioning the receiving instrument at the same time.
This type of programming is especially convenient when an identical configuration setting is required for multiple modules. It saves you a considerable time by simply calling a pre-defined setting and downloading it from the PC software.
The PC configuration is available with various signal conditioner series including M2X, M3L, M3SX and M6X Series.
n “One-Step Cal” ConfigurationEven when you do not have a PC at your disposal, a simulator and a multimeter can help you program I/O ranges.
The internal DIP switches are used to configure input and output type. Once the module is configured, precise ranges can be set with the front control buttons using a simulator connected to the input terminals and a multimeter connected to the output terminals as a reference.
For example, suppose that the DIP switches are configured for the J type thermocouple. Turn the power supply to the transmitter on and press MODE button to enter to the Input Calibration Mode. Apply the desired minimum (e.g. 0°C) and maximum (e.g. 400°C) input levels and push the DOWN (zero) and UP (span) respectively to set the input range to 0 to 400°C. Then the output range can be calibrated in a similar manner after moving to the Output Calibration Mode.
The front LED’s colors and flashing patterns help you easily identify the transmitter’s status and confirm the setup actions in each step of Calibration Modes.
“One-Step Cal” configuration is available with the M3L and M2L Series signal conditioners.
n Front Control Buttons with Local DisplayThe MX Series signal conditioners and the AS4 Series limit alarms are provided with two displays on the front face: 4-digit DATA display and 2-digit ITEM display. Using Up/Down buttons, configuration is simple by calling parameters’ ID numbers (ITEM) and choosing values (DATA).
The M7E Series limit alarms are provided with a multi-line LCD display, which shows the parameters and selections in text to guide you through the programming procedure: intuitive, easy programming just like operating your mobile phone. You won’t need to consult the instruction manual.
These displays indicate process values once commissioned at the field site, and the soft-ware’s “programmable” mode can be locked out in order to prevent unwanted changes in the setting.
Configurable Signal Conditioners — Choose your way of configuration.
Basic Setting View Trend Graph View
MODE Button
DOWN Button
UP Button
LCD Display
Mode Button
Set Button
PC ConfiguratorJack
Up Button
Down ButtonITEM No. Display
DATA UP-DOWN Keys
ITEM No. UP-DOWN Keys
DATA Display
ProgrammingError LED
Polarity LED
MX Series Front Panel M7E Series Front Panel
Connect the M3LU to a simulator and a multimeter and to a power source.
SimulatorMultimeter
Power Source
Input Output
M3SX Series
M3L Series Front Panel
B
76
Four-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors Lightning Surge Protectors
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1
Two-wire Product Selection Guide
27-UNIT Series
26-UNIT Series
B6-UNIT Series
B3-UNIT Series
B5-UNIT Series
6-UNIT Series
T-UNIT Series
B-UNIT Series
Two-
wire
Sig
nal C
ondi
tione
rs
Two-wire Signal Conditioners Product Selection Guide BFour-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors
Lightning Surge Protectors
77
Two-wire Product Selection Guide
Two-wire Signal Conditioners Product Selection Guide
27-UNIT Series
26-UNIT Series
B6-UNIT Series
B3-UNIT Series
B5-UNIT Series
6-UNIT Series
T-UNIT Series
B-UNIT Series
Two-
wire
Sig
nal C
ondi
tione
rs
Specifications are subject to change without notice.ISP1-1
Head-mount, Programmable 27-UNIT Series
Head-mount 26-UNIT Series
Field-mount B6-UNIT Series
DIN Rail Mount B3-UNIT Series
Low Profile B5-UNIT Series
Hockey-puck Style 6-UNIT Series
Compact Size T-UNIT Series
Space-saving, Plug-in B-UNIT Series
P.78 P.82 P.84 P.86 P.90
Construction Sensor head-mounting Sensor head-mounting Outdoor enclosure (IP65) Front terminal access Terminal block Hockey-puck style Stand-alone; terminal access at the front Plug-in
Isolation Input to output Input to output Input to output to outdoor enclosure Input to output Input to output Input to output Input to output Input to output
Dielectric Strength 1500V AC 1500V AC 1500V AC 2000V AC 2000V AC 500V AC 500V AC 500V AC
Range Selectability PC or HART programming Specified when ordering HART (PC) programmingSpecified when ordering or HART (PC) / PROFIBUS-PA
(PC) / DIP switch programmingSpecified when ordering Specified when ordering or
DIP switch programming Specified when ordering Specified when ordering
Operating Temperature -40 to +85°C (-40 to +185°F)
-40 to +85°C (-40 to +185°F)
-40 to +85°C (-40 to +185°F)
-40 to +85°C(-40 to +185°F)
-40 to +80°C (-40 to +176°F)
-5 to +70°C (23 to 158°F)
-5 to +60°C (23 to 140°F)
-5 to +55°C (23 to 131°F)
Mounting Head mount or Field mount Head mount Field mount DIN rail DIN rail DIN rail
with mounting plate A-31 Surface or DIN rail Surface or DIN rail
Dimensions 44 dia. × 20.7 mm (1.732 dia. × 0.81”)
43.5 dia. × 26.5 mm (1.71 dia. × 1.04”) 110 (4.33”) dia. W18 × H106 × D110.5 mm
Configuration Single-phase / 2-wire and 3-wire,3-phase / 3-wire and 4-wire
External Interface
Modbus, Do × 1, Di × 14 – 20mA DC × 41 – 5V DC × 44 – 20mA DC × 2, Do × 1, Di × 11 – 5V DC × 2, Do × 1, Di × 14 – 20mA DC × 2, Do × 21 – 5V DC × 2, Do × 2Modbus, Do × 3Do × 4
•••••••••
M4 Screw Connection LT-UNIT Series
M3.5 Screw Connection L-UNIT Series
Plug-in K-UNIT Series
P.96
Construction Terminal access at the front Terminal access at the front Plug-in
Isolation Input to output to power Input to output to power Input to DC output to relay output to power Input to output to power Input to output to power Input to output to power
Dielectric Strength 2000V AC 2000V AC 2000V AC 2000V AC 2000V AC 1000V AC
Input Range Selectability Front key programming Front control buttons or PC software Specified when ordering Specified when ordering Specified when ordering Specified when ordering
No. of Alarm Point 2, 4 2, 4 2 2 2 1 or 2Relay Form Dual SPDT or Quad NO or NC Dual SPDT or Quad NO or NC SPDT SPDT SPDT SPDT or DPDT
Alarm Setting Front key programming Front control buttons or PC software Thumbwheel switches 10-position rotary switches 270°-turn screwdrivers Three-turn screwdrivers
Power Input AC / DC AC / DC AC / DC AC / DC AC / DC AC / DC
Operating Temperature -5 to +55°C (23 to 131°F)
-5 to +55°C (23 to 131°F)
-5 to +55°C (23 to 131°F)
-5 to +60°C (23 to 140°F)
-5 to +60°C (23 to 140°F)
-5 to +60°C (23 to 140°F)
Mounting Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface or DIN rail Surface (DIN rail available for 11-pin base)
Electronic Actuators& Position Sensors Lightning Surge Protectors
Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1
Limit Alarms Product Selection Guide
Limit AlarmsProduct Selection Guide
EFour-wire Signal Conditioners
Two-wire Signal Conditioners
Power Transducers
Indicators
Limit Alarms
Gateway,Remote I/O
Paperless RecordingSystem
PC Recorder
Electronic Actuators& Position Sensors
Lightning Surge Protectors
139
Limit Alarms Product Selection Guide
Limit AlarmsProduct Selection Guide
Specifications are subject to change without notice.ISP1-1
n Digital Adjustments n Dial/Potentiometer Adjustments n Thumbwheel Switch Adjustments
MSEF M6SXAS, M6NXAS, M6DXAS KSE L4AS ASD1 KSED
Construction Plug-in Ultra-slim Plug-in Discrete box; terminal access at the front Plug-in Plug-in
Connection M3.5 screw terminal Tension-clamp, M3 screw terminal, Euro terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminal M3.5 screw terminalIsolation Input to output to power Input to output to power Input to output to power Input to output to power Input to output to power Input to output to power
Dielectric Strength 2000V AC 2000V AC 2000V AC 2000V AC 2000V AC 2000V ACInput Type DC input DC input DC input DC input DC input DC input
Input Range Selectability Front control buttons Specified when ordering or PC programming Specified when ordering Specified when ordering Specified when ordering Specified when ordering
No. of Alarm Point 2 1 1, 2 2, 4 2 2Relay Form SPDT SPDT SPDT SPDT SPDT SPDT
Alarm Setting Front control buttons PC software Dials Single-turn screwdrivers or dials Thumbwheel switches Thumbwheel switchesAlarm Setpoint -14 to +113.5% -2 to +102% -15 to +120% -15 to +115% 0 – 99% 0 – 99%
Isolation Input to output to power Input to output to power Input to output to power Input to output to powerDielectric Strength 2000V AC 2000V AC 2000V AC 2000V AC
Input Type DC input DC input DC input DC inputInput Range Selectability Specified when ordering Specified when ordering Specified when ordering Specified when ordering
No. of Alarm Point 2 1 1 2Relay Form SPDT DPDT SPDT SPDT