Top Banner
Installation example: Technical data : Supply: 230 V AC, 50/60 Hz Mains fuse: max. 13A Integrated fuse: T4AH 250 V AC Max load: 4 A (920VA) Enclosure IP 22 Dimension(HxBxD): 100 x 72 x 66 mm o Ambient temperature: 0-40 C non condensing Regulation output: 5-100% Description: Control of heating elements and other ohmic loads up to 4,0A. The switch is integrated into the potentiometer. When the potentiometer is switched off the power consumption is 0W. Heat Control 4 is a pulse/wave train regulator which functions by adjusting the time the output voltage is turned on. The pulse periode is approximately 12 seconds. The time of the periode is fixed and cannot be adjusted. At 50% the output power is turned on for 6 seconds and turned off for 6 seconds. The output power starts at 5% in minimum and can be adjusted to 100% in maximum. The light on the front turns on when there is voltage on the output. Mounting: The regulator is mounted in blind cover for LS shaver enclosure. Heat Control 4 4A Manual regulator with switch Adjustment: The heating level is adjusted on the button at the front of Heat Control 4. L N 2 1 N reg L 230V AC max 13A Installation with heating element: Tegning: 950-205302_HEAT_CONTROL4_ES1055_DK Rev.: 1.0 Dato: 18/3-2013 Tegnet af: KM/df Producent: LS Control A/S [email protected] tel. +45 5550 5550 fax +45 5550 2265 Fuse T4AH
1

950-205302 HEAT CONTROL 4 ES1055 UKlscontrol.dk/resources/product/306/04/user-guide-heat-control-4.pdf · Installation example: Technical data : Supply: 230 V AC, 50/60 Hz Mains fuse:

Jan 31, 2018

Download

Documents

lylien
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 950-205302 HEAT CONTROL 4 ES1055 UKlscontrol.dk/resources/product/306/04/user-guide-heat-control-4.pdf · Installation example: Technical data : Supply: 230 V AC, 50/60 Hz Mains fuse:

Installation example:

Technical data :Supply: 230 V AC, 50/60 HzMains fuse: max. 13AIntegrated fuse: T4AH 250 V ACMax load: 4 A (920VA)Enclosure IP 22Dimension(HxBxD): 100 x 72 x 66 mm

oAmbient temperature: 0-40 C non condensingRegulation output: 5-100%

Description:Control of heating elements and other ohmic loads up to 4,0A. The switch is integrated into the potentiometer. When the potentiometer is switched off the power consumption is 0W.

Heat Control 4 is a pulse/wave train regulator which functions by adjusting the time the output voltage is turned on. The pulse periode is approximately 12 seconds. The time of the periode is fixed and cannot be adjusted.

At 50% the output power is turned on for 6 seconds and turned off for 6 seconds.

The output power starts at 5% in minimum and can be adjusted to 100% in maximum. The light on the front turns on when there is voltage on the output.

Mounting:

The regulator is mounted in blind cover for LS shaver enclosure.

Heat Control 4 4A Manual regulator with switch

Adjustment:The heating level is adjusted on the button at the front of Heat Control 4.

L

N2

1N reg

L 230V AC max 13A

Installation with heating element:

Tegning: 950-205302_HEAT_CONTROL4_ES1055_DKRev.: 1.0Dato: 18/3-2013Tegnet af: KM/dfProducent: LS Control A/S

[email protected] tel. +45 5550 5550 fax +45 5550 2265

Fuse T4AH