Performance Analysis per Transceiver Basis PERFORMANCE ANALYSIS PER TRANSCEIVER BASIS..................................................................1 ABSTRACT ...................................................................................................................................................2 INTRODUCTION..........................................................................................................................................2 BTS STATISTICS..........................................................................................................................................2 2.1 DESCRIPTION OF MEASUREMENTS..................................................................................................................3 2.1.1 Intermittent Fault Measurement......................................................................................................3 2.1.2 TRA Synchronization Fault Measurement......................................................................................3 2.1.3 Connection Statistics Measurement................................................................................................3 BTS COUNTERS AND OBJECT TYPE.......................................................................................................................3 2.2.1 Transceiver Group..........................................................................................................................4 PC TRASYNCCNT TRA SYNCHRONIZATION FAULTS. INCREMENTED WHEN A ....................................................4 TRA SYNCHRONIZATION FAULT IS REPORTED, BY THE BTS, .............................................................................4 ON ONE OF THE TIMESLOTS WITHIN THE TG .........................................................................................................4 2.2.2 Timeslots..........................................................................................................................................4 PC CONCNT Connection setup attempts. Incremented each time a ....................................................4 2.3 BTS STATISTIC AND FORMULA.....................................................................................................................5 2.4 CAPABILITIES..............................................................................................................................................5 2.4.1 Object Type: MOTG........................................................................................................................5 NUMBER OF COUNTERS = 2............................................................................................................................5 2.4.2 Object Type: MOTS.........................................................................................................................5 TOTAL LOAD CONTRIBUTION = NUMBER OF TSS * (NUMBER OF COUNTERS + TS STATE INDICATOR)..................................................................................................................................................5 3. MOTS STATISTICS COLLECTION......................................................................................................6 Even though the object type MOTS is not enabled, it is still possible to fetch the counter statistics for both CONCNT and CONERRCNT. This is done by using the command RXMFP in the OSS:...............6 3.1 COMMAND DESCRIPTION: RXMFP..............................................................................................................6 3.2 EXECUTING THE RXMFP COMMAND.............................................................................................................6 WHERE XX IS THE TG NUMBER........................................................................................................................6 3.3 COUNTER SIZE............................................................................................................................................7 3.4 COLLECTING THE COUNTER STATISTICS............................................................................................................7 If ..............................................................................................................................................................7 Then..........................................................................................................................................................7 CONCNTt = 65535 - CONCNTbefore + CONCNTafter (2)..............................................................7 3.5 RECOLLECTION OF STATISTICS.......................................................................................................................8 4. DROPPED CALL RATE...........................................................................................................................8 4.1 DROPPED CALL RATE PER TIMESLOT................................................................................................................8 4.2 DROPPED CALL RATE PER TRX ....................................................................................................................9 5. TABULATING STATISTICS ..................................................................................................................9 5.1 COMMAND DESCRIPTION.............................................................................................................................10 5.1.1 Command description RXCDP......................................................................................................10 5.1.2 Command description RXHDP.....................................................................................................10 5.2 TABULATING COUNTER VALUES FOR NON FREQUENCY HOPPING CELLS................................................................11 5.3 TABULATING COUNTER VALUES FOR SYNTHESIZER HOPPING CELLS.....................................................................13 5.4 TABULATING COUNTER VALUES FOR BASEBAND HOPPING CELLS ........................................................................14 6. ANALYSIS OF TIMESLOT PERFORMANCE...................................................................................20 15 October, 2001 1
30
Embed
52479642 Performance Analysis Per Transceiver Basis
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Performance Analysis per Transceiver Basis
PERFORMANCE ANALYSIS PER TRANSCEIVER BASIS..................................................................1
2.1 DESCRIPTION OF MEASUREMENTS..................................................................................................................32.1.1 Intermittent Fault Measurement......................................................................................................32.1.2 TRA Synchronization Fault Measurement......................................................................................32.1.3 Connection Statistics Measurement................................................................................................3
BTS COUNTERS AND OBJECT TYPE.......................................................................................................................32.2.1 Transceiver Group..........................................................................................................................4
PC TRASYNCCNT TRA SYNCHRONIZATION FAULTS. INCREMENTED WHEN A ....................................................4 TRA SYNCHRONIZATION FAULT IS REPORTED, BY THE BTS, .............................................................................4ON ONE OF THE TIMESLOTS WITHIN THE TG .........................................................................................................4
2.2.2 Timeslots..........................................................................................................................................4PC CONCNT Connection setup attempts. Incremented each time a ....................................................4
2.3 BTS STATISTIC AND FORMULA.....................................................................................................................52.4 CAPABILITIES..............................................................................................................................................5
2.4.1 Object Type: MOTG........................................................................................................................5 NUMBER OF COUNTERS = 2............................................................................................................................5
TOTAL LOAD CONTRIBUTION = NUMBER OF TSS * (NUMBER OF COUNTERS + TS STATE INDICATOR)..................................................................................................................................................5
3. MOTS STATISTICS COLLECTION......................................................................................................6
Even though the object type MOTS is not enabled, it is still possible to fetch the counter statistics for both CONCNT and CONERRCNT. This is done by using the command RXMFP in the OSS:...............6
3.1 COMMAND DESCRIPTION: RXMFP..............................................................................................................63.2 EXECUTING THE RXMFP COMMAND.............................................................................................................6WHERE XX IS THE TG NUMBER........................................................................................................................63.3 COUNTER SIZE............................................................................................................................................73.4 COLLECTING THE COUNTER STATISTICS............................................................................................................7
If ..............................................................................................................................................................7Then..........................................................................................................................................................7CONCNTt = 65535 - CONCNTbefore + CONCNTafter (2)..............................................................7
3.5 RECOLLECTION OF STATISTICS.......................................................................................................................8
5.2 TABULATING COUNTER VALUES FOR NON FREQUENCY HOPPING CELLS................................................................115.3 TABULATING COUNTER VALUES FOR SYNTHESIZER HOPPING CELLS.....................................................................135.4 TABULATING COUNTER VALUES FOR BASEBAND HOPPING CELLS ........................................................................14
6. ANALYSIS OF TIMESLOT PERFORMANCE...................................................................................20
15 October, 2001 1
6.1 FREQUENCY INTERFERENCE – NON HOPPING.................................................................................................206.2 FREQUENCY INTERFERENCE – SYNTHESIZER HOPPING.....................................................................................216.3 FREQUENCY INTERFERENCE – BASEBAND HOPPING........................................................................................216.4 HARDWARE FAULTY ..................................................................................................................................22
The process of radio network optimization involves investigation of cells having bad
performance. This is regardless of any poor KPI figures, for example, high drop call rate,
low handover success rate, poor call setup success rate and etc. The are many reasons that
contribute to the poor cell performance. This document describes one of many techniques
to identify if a particular transceiver unit or specific timeslots causes the problem and
highlight some of the method to troubleshoot the problem. The KPI being focussed in
discussion is the dropped call rate.
Introduction
There are many types of cell configuration. There are cells with one, two, or more
transceiver unit (TRU). This is due to the design and capacity requirement. The
performance of all transceiver unit and timeslots within a cell should be fairly similar.
This statement is true to a certain extend, where the frequency plan as well as both
hardware and software version and reliability needs to be taken into account. Hence,
should there be a large variation in terms of each transceiver’s performance, the problem
should be further analyzed.
BTS Statistics
The following describes the BTS level statistics that can be used to monitor the
performance of the cells.
15 October, 2001 2
2.1 Description of Measurements
2.1.1 Intermittent Fault Measurement
One intermittent fault counter exists per transceiver group (TG). The counter is
stepped when an intermittent fault is reported on one of the managed objects within the
TG.
2.1.2 TRA Synchronization Fault Measurement
One TRA synchronization fault counter exists per transceiver group (TG). The
counter is stepped when a TRA synchronization fault is reported, by the BTS, on one of
the Timeslots within the TG.
2.1.3 Connection Statistics Measurement
There are two counters per Timeslot Handler (TS), one stores connection setup
attempts on logical channels served by the TS and the other stores abnormally terminated
connections on logical channels served by the TS. The first counter is stepped each time a
Traffic Channel (TCH) or Stand Alone Dedicated Control Channel (SDCCH) is seized.
The second counter is stepped for TCH and SDCCH whenever a connection is dropped
due to any of the following reasons:
• Error indication
• Connection failure indication
• Abnormal disconnect request (due to Timing Advance larger than the value specified
for the cell or number of Measurement Results received less than specified for the
cell)
• Trace failure at Small Restart
• Forlopp release
BTS counters and object type
There are two types of counters, namely Peg Counter (PC) and Status Counter (ST).
PC is Peg Counter, where it shows the accumulated number of events or the accumulated
value of a counter. A peg counter can only be incremented. While ST shows the counter
15 October, 2001 3
value at a specific moment (i.e. snapshot). A status counter can be incremented or
decremented.
2.2.1 Transceiver Group
Object Type = MOTG (Managed Object Transceiver Group)
Measurements are done per transceiver group record.
In order to allow insertion of the INTERCNT and TRASYNCCNT counters, the TG must
be defined.
Type Counter Name Description
PC INTERCNT Intermittent faults. Incremented when an
intermittent fault is reported on one of the managed
objects within the TG
PC TRASYNCCNT TRA synchronization faults. Incremented when a
TRA synchronization fault is reported, by the BTS,
on one of the timeslots within the TG
2.2.2 Timeslots
Object Type = MOTS (Managed Object Time Slot Handler)
Measurements are done per Time Slot Handler (TS)
In order to allow insertion of the CONERRCNT and CONCNT counters, the TS must be
defined.
Type Counter Name Description
PC CONERRCNT Abnormally terminated connections. Incremented
for TCH and SDCCH when a connection is dropped
due to reasons specified in 2.1.3
PC CONCNT Connection setup attempts. Incremented each time a
TCH or SDCCH is seized
15 October, 2001 4
2.3 BTS Statistic and formula
One very useful statistic to be monitored is Drop Connections on Timeslot Basis
The formula is calculated per TS regardless of SDCCH or TCH connections.
TS_DR = Abnormally Terminated Connections of Total Number of
Connection Setup Attempts
= %100CONERRCNT
CONCNT ∗
2.4 Capabilities
The size of the counters is 16 bits. The number of counters to be handled by the STS
Database is limited. The capacity of STS is shared among the statistical measurement
functions in the BSC. Therefore when these BTS statistic counters are enabled, it will
occupied an amount of capacity and thereby, increasing the STS load.
2.4.1 Object Type: MOTG
Total load contribution = Number of TGs * (Number of counters + TG state
indicator)
Where Number of TGs is size alterable and max size is 512.
Number of counters = 2
TG state indicator = 1
2.4.2 Object Type: MOTS
Total load contribution = Number of TSs * (Number of counters + TS state indicator)
Where Number of TSs is size alterable and max size is 8160.
Number of counters = 2
TS state indicator = 1
The amount of statistics expected to be pegged for the MOTS counters can be done by
estimating at the amount of timeslots that exist in a BSC. Looking at the amount of
timeslots in a BSC, this will certainly increase the load for STS measurements. That is
why, this object type is normally not enabled in a network.
15 October, 2001 5
To be able to fetch the statistics from object type MOTS, while not increasing the STS
load, an alternative method can be used. This method is described in the next section.
3. MOTS statistics collection
Even though the object type MOTS is not enabled, it is still possible to fetch the counter
statistics for both CONCNT and CONERRCNT. This is done by using the command
RXMFP in the OSS:
3.1 Command Description: RXMFP
This command initiates the printing of fault information for one or more managed
object instances or all defined managed object instances of a specified managed object
type. The operator can specify, using the parameter FAULTY, that the information is
only printed for faulty managed object instances.
A managed object instance is considered to be faulty if it is blocked from its own
supervision in state NOOP, or is in state FAIL.
The operator can specify, using the parameter SUBORD, that information is also
printed on all managed object instances subordinate to one or more specified managed
object instances.
No more than 32 managed object instances can be specified in the command. The order
does not remain after system restart [2].
3.2 Executing the RXMFP command
Below describes how to execute the command to fetch statistics for both CONCNT and
CONERRCNT.
RXMFP:MO=RXOTS-XX-YY-0&&-7;
Where XX is the TG number
YY is the TRX number
0&&-7 specifies timeslot 0 to timeslot 7
15 October, 2001 6
3.3 Counter size
Since the size of the counter for both CONCNT and CONERRCNT is only 16 bits,
when the counters reached a maximum value of 65535 (which is calculated by 216-1), the
counter will reset to zero and start counting again.
3.4 Collecting the counter statistics
As highlighted earlier, the counter statistics are able to be collected using the
RXMFP command. But the duration between collection of statistic counters before and
after needs to be carefully defined. A period of two to three hours is recommended.
The counter CONCNT and CONERRCNT will give an accumulation value of connection
establishment and abnormal connection termination for a particular timeslot respectively
at a particular time. But looking at this is a peg counter, these counters are accumulated
each time the event occur.
Let say CONCNTbefore and CONERRCNTbefore are values collected initially and
CONCNTafter and CONERRCNTafter are values collected after a certain period of time, t.
Since the counter will reset to 0 when it reaches 65535, there is a possibility that the
counter values collected after time duration is less than what it was before. Therefore, to
determine what was the number of connection establishments during that specified period
of time, the equation below are used.
Let’s say number of connection establishment during time t is denoted as CONCNTt
If
CONCNTafter > CONCNTbefore ,
Then,
CONCNTt = CONCNTafter - CONCNTbefore (1)
If
CONCNTafter < CONCNTbefore ,
Then
CONCNTt = 65535 - CONCNTbefore + CONCNTafter (2)
Similarly, the number of abnormal connection terminations for that specified period of
time CONERRCNTt can be determined by replacing CONCNT with CONERRCNT in
15 October, 2001 7
equation (1) and (2). Note that the period, t should not be set too long to prevent the
counters to reset more than one time and that will make equation (1) and (2) to be invalid.
This is because the counter accumulation depends on the amount of traffic and subscriber
behavior for this cell.
3.5 Recollection of statistics
If the value of connection establishment and abnormal connection terminations as
calculated from Section 3.4 are very small, then, it is recommended to recollect the
statistics for a longer time duration or/and at different hours, i.e. during peak hour.
Having more data samples will be able to draw better conclusion when analyzing the
timeslots performance.
If any of the timeslot configurations was changed, say a timeslot was block/deblock
or a TRU was being replaced during the statistic collection time, the values collected will
not be valid. Then, it is essential to recollect the statistics again.
4. Dropped call rate
Useful hints can be obtained by looking at the number of abnormal connection
terminations on each timeslot. Since the allocation of timeslot to the mobile station is
being done according to the ICM band, timeslots with small number of connection
establishments may yields higher ICM band as compared to those timeslots with higher
number of connection establishments. Hence, poor performance may be suspected at
these high ICM band timeslots. However this may not be 100% true. For example,
timeslots that have hardware problem but good ICM band may have more connection
establishments. Nonetheless the drop connections may as well results a high number.
Consequently, by just looking at the timeslots with a high number of abnormal
connections termination may not yield bad performance. It is more valid to look at the
dropped call rate instead.
4.1 Dropped call rate per timeslot
The dropped call rate per timeslot, during time, t (TS_DRt) can be determined based on
the following equation:
15 October, 2001 8
%1 0 0C O N C N T
C O N E R R C N TD R_T S
t
tt ∗=
4.2 Dropped call rate per TRX
Similarly, the dropped call rate per TRX during time, t (TRX_DRt) can be calculated as
below.
%1 0 0t,t i m e_d u r i n g_T R X_p e r_e s t a b_C o n n e c t i o n
t,t i m e_d u r i n g_T R X_p e r_c o n n e c t i o n_D r o pD R_T R X t ∗=
∑= i it )C O N E R R C N T(t,t i m e_d u r i n g_T R X_p e r_c o n n e c t i o n_D r o p
∑= i it )C O N C N T(t,t i m e_d u r i n g_T R X_p e r_n te s t a b l i s m e_C o n n e c t i o n
where i ranged from 0 to 7, denoting the TCH timeslots in particular TRX.
For the BCCH TRX, timeslot 0 is used to carry BCCH and therefore, no call
establishment is allowed in this timeslot. Therefore, i ranged from 1 to 7 for BCCH TRX.
Timeslot 0 is not included in the calculation.
Correspondingly, when evaluating the TCH dropped call performance, the timeslots
carrying SDCCH should also be excluded in the calculation.
5. Tabulating Statistics
The printout from command RXMFP will be able to display the statistic CONCNT and
CONERRCNT for every timeslot. These timeslots are represented in this format as below.
Timeslot = RXOTS-XX-YY-Z
Where XX is the Transceiver Group (TG) number
YY is the TRX number
Z is the timeslot number (0-7)
15 October, 2001 9
These timeslots representation is just software based interpretation and does not map
directly to the hardware position. For example, RXOTS-20-0-1 represents slot number 1
at TRX0 and TG20 in the software point of view, but it is not necessary that these
timeslot points to slot number 1 at TRX0 in the physical TRU.
By default the timeslots representation in software should be inline with the hardware.
But the inconsistency may due to various reasons. For example, a block/deblock
command was carried out for some MO or one of the TRX is faulty and etc.
Hence, when tabulating the counter values, it is necessary to find out exactly which
timeslot in the software corresponds to which timeslot in the hardware TRU. A way to do
this by using command RXCDP and RXHDP.
5.1 Command description
Both the commands RXCDP and RXHDP will be describe in brief in the following
section. More information can be obtained at [2].
5.1.1 Command description RXCDP
The command is used to initiate printing of managed object (MO) configuration data for
one or more managed object instances. The answer printout, “RADIO X-CEIVER
ADMINISTRATION MANAGED OBJECT CONFIGURATION DATA”, indicates how
each MO specified in the MO parameter is configured. When the MO class TG is
specified, MO configuration data for all related RX, TS, TX and DP are printed. The
order does not remain after system restart [2].
5.1.2 Command description RXHDP
This command is used to initiate printing of MO hopping data for one or more MO
instances. The answer printout, “RADIO X-CEIVER ADMINISTRATION MANAGED
OBJECT HOPPING DATA”, indicates how each managed object specified in the MO
parameter is configured for frequency hopping. The order does not remain after system
restart [2].
15 October, 2001 10
5.2 Tabulating counter values for non frequency hopping cells
15 October, 2001 11
When frequency hopping is disabled, the process to find the mapping of the timeslot in
hardware and software is fairly straightforward. The command to be used is RXCDP.
Every TRX will have its own dedicated absolute radio frequency channel number
(ARFCN) and this will be the information used to differentiate the TRXs. Example of the
RXCDP command printout is shown as follows.
Figure 5.2.1 Answer printout for command RXCDP
15 October, 2001 12
<RXCDP:MO=RXOTG-170;
RADIO X-CEIVER ADMINISTRATIONMANAGED OBJECT CONFIGURATION DATA
MO RESULT ARFCN MISMATCHRXORX-170-0 CONFIG HOP NONERXORX-170-1 CONFIG HOP NONERXORX-170-2 CONFIG HOP NONERXORX-170-3 CONFIG HOP NONE
MO RESULT ARFCN TXAD TN BPC CHCOMB OFFS XRA ICMRXOTS-170-0-0 CONFIG 811 9 7 3270 TCH 0 NO ONRXOTS-170-0-1 CONFIG 811 9 6 3252 TCH 0 NO ONRXOTS-170-0-2 CONFIG 811 9 5 3218 TCH 0 NO ONRXOTS-170-0-3 CONFIG 811 9 4 3201 TCH 0 NO ONRXOTS-170-0-4 CONFIG 811 9 3 3174 TCH 0 NO ONRXOTS-170-0-5 CONFIG 811 9 2 3161 TCH 0 NO ONRXOTS-170-0-6 CONFIG 811 9 1 3122 TCH 0 NO ONRXOTS-170-0-7 CONFIG 811 9 0 3107 TCH 0 NO ONRXOTS-170-1-0 CONFIG 798 10 7 3164 TCH 0 NO ONRXOTS-170-1-1 CONFIG 798 10 6 3110 TCH 0 NO ONRXOTS-170-1-2 CONFIG 798 10 5 3100 TCH 0 NO ONRXOTS-170-1-3 CONFIG 798 10 4 3093 TCH 0 NO ONRXOTS-170-1-4 CONFIG 798 10 3 3084 TCH 0 NO ONRXOTS-170-1-5 CONFIG 798 10 2 3082 TCH 0 NO ONRXOTS-170-1-6 CONFIG 798 10 1 3078 TCH 0 NO ONRXOTS-170-1-7 CONFIG 798 10 0 3077 TCH 0 NO ONRXOTS-170-2-0 CONFIG 774 2 1 3308 SDCCH8 0 NO ONRXOTS-170-2-1 CONFIG 762 11 7 3254 TCH 0 NO ONRXOTS-170-2-2 CONFIG 762 11 6 3238 TCH 0 NO ONRXOTS-170-2-3 CONFIG 762 11 5 3217 TCH 0 NO ONRXOTS-170-2-4 CONFIG 762 11 4 3187 TCH 0 NO ONRXOTS-170-2-5 CONFIG 762 11 3 3171 TCH 0 NO ONRXOTS-170-2-6 CONFIG 762 11 2 3149 TCH 0 NO ONRXOTS-170-2-7 CONFIG 762 11 0 3118 TCH 0 NO ONRXOTS-170-3-0 CONFIG 774 2 0 3300 BCCH 0 NO ONRXOTS-170-3-1 CONFIG 774 2 2 3281 SDCCH8 0 NO ONRXOTS-170-3-2 CONFIG 762 11 1 3243 TCH 0 NO ONRXOTS-170-3-3 CONFIG 774 2 7 3213 TCH 0 NO ONRXOTS-170-3-4 CONFIG 774 2 6 3176 TCH 0 NO ONRXOTS-170-3-5 CONFIG 774 2 5 3162 TCH 0 NO ONRXOTS-170-3-6 CONFIG 774 2 4 3137 TCH 0 NO ONRXOTS-170-3-7 CONFIG 774 2 3 3108 TCH 0 NO ON
MO RESULT ARFCN TXAD BSPWR C0F MISMATCHRXOTX-170-0 CONFIG 774 2 45 YES NONERXOTX-170-1 CONFIG HOP 9 45 NO NONERXOTX-170-2 CONFIG HOP 10 45 NO NONERXOTS-170-3 CONFIG HOP 11 45 NO NONE
According to the command printout in Figure 5.2.1, this cell is using TG170, with 4
TRX. Frequency hopping is disabled and the ARFCN used is 774 (BCCH), 762, 798 and
811.
RXOTS-170-0-0 is corresponding to TXAD9 and TN7. This proves that RXOTS-170-0-0
is the software does not correspond to hardware timeslot 0 of first TRU. But, it is actually
mapped to timeslot 7 in TRU9 physically.
While all RXOTS-170-2-X (where X is 1,2,3,..7) are mapped to TRU11, RXOTS-170-2-0
is mapped to TRU2. Similarly, all RXOTS-170-3-X (where X is 0,1,7 except 2) are
mapped to TRU2 while RXOTS-170-3-2 is mapped to TRU11.
Therefore when determining the dropped call per TRX for this cell, the table below
should be used.
TRU TXAD TN ARFCN MO CONCNTbefore CONERRCNTbefore CONCNTafter CONERRCNTafter
Table 5.2.1 Mapping of timeslots position between software and hardware
5.3 Tabulating counter values for synthesizer hopping cells
Tabulating counter values for synthesizer hopping cells (not hopping through BCCH) is
the same as described in section 5.3. The only difference is that under the column
ARFCN in RXCDP printout, the printout will be “HOP” for hopping TRXs and the
15 October, 2001 13
ARFCN for non-hopping (BCCH) TRX. The technique to distinguish the mapping of the
timeslots is identical.
5.4 Tabulating counter values for baseband hopping cells
When baseband frequency hopping is used, the process to find the mapping of the
timeslot in hardware and software is quite complicated. A straightforward method is to
disable the hopping and then repeat the process as discussed in section 5.4.
An alternative method is to use the command RXCDP as well as RXHDP. The parameter
to differentiate different TRU will be TXAD and MAIO. Example of the RXCDP and
RXHDP command printout is shown as follows. This method has yet to be verified to be
reliable for all the baseband hopping cells.
15 October, 2001 14
15 October, 2001 15
15 October, 2001 16
Figure 5.4.1 Answer printout for command RXCDP
According to Figure 5.4.1, the cell is having 4 TRX, using baseband hopping. The
BCCH frequency is 805 while the hopping TCHs are 805, 769, 781 and 793. Since
the TXAD at the MO RXOTS is displayed as “HOP” except for BCCH timeslot, that
is TXAD 0, it is therefore difficult to distinguish which RXOTS maps to which TRU.
Hence, the printout of RXHDP is used. Figure 5.4.2 shows an example of the
printout.
15 October, 2001 17
<RXCDP:MO=RXOTG-79;
RADIO X-CEIVER ADMINISTRATIONMANAGED OBJECT CONFIGURATION DATA
MO RESULT ARFCN MISMATCHRXORX-79-0 CONFIG HOP NONERXORX-79-1 CONFIG HOP NONERXORX-79-2 CONFIG HOP NONERXORX-79-3 CONFIG HOP NONE
MO RESULT ARFCN TXAD TN BPC CHCOMB OFFS XRA ICMRXOTS-79-0-0 CONFIG HOP HOP 1 6895 TCH 3 NO ONRXOTS-79-0-1 CONFIG HOP HOP 7 6889 TCH 3 NO ONRXOTS-79-0-2 CONFIG HOP HOP 6 6887 TCH 3 NO ONRXOTS-79-0-3 CONFIG HOP HOP 5 6871 TCH 3 NO ONRXOTS-79-0-4 CONFIG HOP HOP 4 6869 TCH 3 NO ONRXOTS-79-0-5 CONFIG HOP HOP 3 6867 TCH 3 NO ONRXOTS-79-0-6 CONFIG HOP HOP 2 6850 TCH 3 NO ONRXOTS-79-0-7 CONFIG HOP HOP 0 6838 TCH 3 NO ONRXOTS-79-1-0 CONFIG HOP HOP 1 6890 TCH 3 NO ONRXOTS-79-1-1 CONFIG HOP HOP 7 6888 TCH 3 NO ONRXOTS-79-1-2 CONFIG HOP HOP 6 6886 TCH 3 NO ONRXOTS-79-1-3 CONFIG HOP HOP 5 6870 TCH 3 NO ONRXOTS-79-1-4 CONFIG HOP HOP 4 6868 TCH 3 NO ONRXOTS-79-1-5 CONFIG HOP HOP 3 6865 TCH 3 NO ONRXOTS-79-1-6 CONFIG HOP HOP 2 6849 TCH 3 NO ONRXOTS-79-1-7 CONFIG HOP HOP 0 6837 TCH 3 NO ONRXOTS-79-2-0 CONFIG HOP HOP 1 5331 SDCCH8 3 NO ONRXOTS-79-2-1 CONFIG HOP HOP 7 6864 TCH 3 NO ONRXOTS-79-2-2 CONFIG HOP HOP 6 6862 TCH 3 NO ONRXOTS-79-2-3 CONFIG HOP HOP 5 6860 TCH 3 NO ONRXOTS-79-2-4 CONFIG HOP HOP 4 6854 TCH 3 NO ONRXOTS-79-2-5 CONFIG HOP HOP 3 6852 TCH 3 NO ONRXOTS-79-2-6 CONFIG HOP HOP 2 6848 TCH 3 NO ONRXOTS-79-2-7 CONFIG HOP HOP 0 6836 TCH 3 NO ONRXOTS-79-3-0 CONFIG 805 0 0 5345 BCCH 3 NO ONRXOTS-79-3-1 CONFIG HOP HOP 1 5864 SDCCH8 3 NO ONRXOTS-79-3-2 CONFIG HOP HOP 7 6863 TCH 3 NO ONRXOTS-79-3-3 CONFIG HOP HOP 6 6861 TCH 3 NO ONRXOTS-79-3-4 CONFIG HOP HOP 5 6859 TCH 3 NO ONRXOTS-79-3-5 CONFIG HOP HOP 4 6853 TCH 3 NO ONRXOTS-79-3-6 CONFIG HOP HOP 3 6851 TCH 3 NO ONRXOTS-79-3-7 CONFIG HOP HOP 2 6839 TCH 3 NO ON
MO RESULT ARFCN TXAD BSPWR C0F MISMATCHRXOTX-79-0 CONFIG 805 0 45 YES NONERXOTX-79-1 CONFIG 769 1 45 NO NONERXOTX-79-2 CONFIG 781 2 45 NO NONERXOTX-79-3 CONFIG 793 3 45 NO NONE
END
15 October, 2001 18
Figure 5.4.2.3 RXHDP printout for TRX2
Figure 5.4.2.2 RXHDP printout for TRX1
Figure 5.4.2.4 RXHDP printout for TRX3
Figure 5.4.2.1 RXHDP printout for TRX0
<RXHDP:MO=RXOTS-79-0-0&&-7;
RADIO X-CEIVER ADMINISTRATIONMANAGED OBJECT HOPPING DATA