Top Banner
3200 MGS DIFFERENTIAL MONITORING SYSTEM DATA SHEET FEATURES Battery powered Field repairable system Low battery indicator 30 psi, 100 psi, 300 psi; kPa or bar available upon request 1 psi resolution -50 to 150 celsius; -50 to 300 fahrenheit 1” Male NPT, 2” Male NPT, 2” 1502, 2” 2202, or flanged connections 4-20mA or 0-1 volt output available Solid state platform; no fluids or moving parts Analog bar graph w/ divided scale Simple interface for calibration Verify temperatures with a solid state RTD Customizable bracket sizes and gauge configurations OPTIONS 4-20mA output (additional barrier required) 0-1 volt output Slave, secondary displays available WELL CONTROL MONITORING AT ITS FINEST SAFETY PRECISION INNOVATION APPLICATION The HDI 3200 Mud Gas Separator Monitoring System is composed of intrinsically safe, solid-state electronic pressure gauges used to monitor the liquid seal pressure, mud gas pressure, differential pressure between the liquid seal and mud gas pressures, and temperature parameters found within the Mud Gas Separator. The 3200 System is comprised of HDI 2000B or 2400 Gauge Systems as well as the 3300 Temperature Gauge. This System can monitor pressure ranges up to 300 psi and temperatures up to 150 Celsius with 0.5% accuracy of full scale. Each 2000B and 3300 is comprised of a Gauge Display, Inline Cable, and Sensor Assembly allowing the display to be close or far from the point of measurement. This System is customizable to client specifications and/or space constraints, and it is based on HDI’s 25 year field proven platform. All HDI Gauges provide safety, accuracy, reliability, and low maintenance for the user. CERTIFICATIONS • CSA: Intrinsically Safe Class 1, Division 1, Groups A, B, C and D • ATEX: optional, II 1 G, Ex ia IIC T4
2

3200 MGS DIFFERENTIAL MONITORING SYSTEM DATA SHEET · the Mud Gas Separator. The 3200 System is comprised of HDI 2000B or 2400 Gauge Systems as well as the 3300 Temperature Gauge.

Mar 18, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 3200 MGS DIFFERENTIAL MONITORING SYSTEM DATA SHEET · the Mud Gas Separator. The 3200 System is comprised of HDI 2000B or 2400 Gauge Systems as well as the 3300 Temperature Gauge.

3200 MGS DIFFERENTIAL MONITORING SYSTEM DATA SHEET

FEATURES

• Battery powered• Field repairable system• Low battery indicator• 30 psi, 100 psi, 300 psi; kPa or bar available upon request• 1 psi resolution• -50 to 150 celsius; -50 to 300 fahrenheit• 1” Male NPT, 2” Male NPT, 2” 1502, 2” 2202, or flanged connections• 4-20mA or 0-1 volt output available• Solid state platform; no fluids or moving parts• Analog bar graph w/ divided scale• Simple interface for calibration• Verify temperatures with a solid state RTD• Customizable bracket sizes and gauge configurations

OPTIONS

• 4-20mA output (additional barrier required)• 0-1 volt output• Slave, secondary displays available

WELL CONTROL MONITORING AT ITS FINEST

SAFETYPRECISION

INNOVATION

APPLICATION

The HDI 3200 Mud Gas Separator Monitoring System is composed of intrinsically safe, solid-state electronic pressure gauges used to monitor the liquid seal pressure, mud gas pressure, differential pressure between the liquid seal and mud gas pressures, and temperature parameters found within the Mud Gas Separator. The 3200 System is comprised of HDI 2000B or 2400 Gauge Systems as well as the 3300 Temperature Gauge. This System can monitor pressure ranges up to 300 psi and temperatures up to 150 Celsius with 0.5% accuracy of full scale. Each 2000B and 3300 is comprised of a Gauge Display, Inline Cable, and Sensor Assembly allowing the display to be close or far from the point of measurement. This System is customizable to client specifications and/or space constraints, and it is based on HDI’s 25 year field proven platform. All HDI Gauges provide safety, accuracy, reliability, and low maintenance for the user.

CERTIFICATIONS

• CSA: Intrinsically Safe Class 1, Division 1, Groups A, B, C and D• ATEX: optional, II 1 G, Ex ia IIC T4

Page 2: 3200 MGS DIFFERENTIAL MONITORING SYSTEM DATA SHEET · the Mud Gas Separator. The 3200 System is comprised of HDI 2000B or 2400 Gauge Systems as well as the 3300 Temperature Gauge.