This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Window 1: Metal Frame with Thermal Break:Fixed, Perf. Type: Energycode default, Single Pane, Clear , SHGC 0.80, [Bldg. Use 1 -School/university]
377 --- --- 1.100 0.290
Door 1: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Type:Energy code default, Single Pane, Clear , SHGC 0.80, [Bldg. Use 1 -School/university]
92 --- --- 1.200 0.770
Door 2: Insulated Metal, Non-Swinging, [Bldg. Use 1 - School/university] 100 --- --- 0.800 0.179Floor 1: Slab-On-Grade:Unheated, Horizontal with vertical >= 4 ft.,[Bldg. Use 1 - School/university] (b)
2794 --- 7.5 0.410 0.520
(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.(b) Slab-On-Grade proposed and budget U-factors shown in table are F-factors.
Envelope Compliance Statement
Envelope PASSES: Design 1% better than code
Interior Lighting Compliance Certificate
Project Title:2015 IECC
Project Type: Addition
Construction Site: Owner/Agent: Designer/Contractor:
AFixture ID : Description / Lamp / Wattage Per Lamp / Ballast
BLamps/Fixture
C# of
Fixtures
1-School/UniversityUndercounter Light Fixture: L1: Other: 1 3 30 91Surface Mounted LED Strip Fixtur: L2 and L2E: Other: 1 3 15 4425" Wide Vanity Fixture: L3: Other: 1 2 20 404" Diamater LED Downlight: L4 and L4E: Other: 1 4 28 1108'-0" Long Linear LED Fixtue: L5E: Other: 1 2 100 20016'-0" Long Linear LED Fixture: L6, L6E and L7E: Other: 1 7 200 140024'-0" Long Linear LED Fixture: L8E: Other: 1 1 300 300Pendant Mounted Fixuture for Ent: L9 and L9E: Other: 1 3 65 195
2380Total Proposed Watts =
Interior Lighting Compliance Statement
Interior Lighting PASSES: Design 2% better than code
Mechanical Compliance Certificate
Project Title:2015 IECC
Project Type: Addition
Location: Denver, ColoradoClimate Zone: 5b
Construction Site: Owner/Agent: Designer/Contractor:
Project InformationEnergy Code:
CMC Leadville
Mechanical Systems ListQuantity System Type & Description
Heating: 1 each - Hydronic or Steam Coil, Hot Water, Capacity = 110 kBtu/h No minimum efficiency requirement appliesFan System: Unspecified
1 HVAC System 1 (Single Zone):
Gas Instantaneous Water Heater, Capacity: 0 gallons, Input Rating: 199 kBtu/h w/ Circulation Pump Proposed Efficiency: 0.81 EF, Required Efficiency: 0.62 EF
1 Water Heater 1:
Mechanical Compliance Statement
SCALE:1 MAIN LEVEL LIGHTING PLAN1/8" = 1'-0"SCALE:2 MEZZANINE LIGHTING PLAN
1/8" = 1'-0"
NOTES:
THE LIGHTING AND ASSOCIATED LIGHTING CONTROLS INTHIS SPACE SHALL BE PRICED AS ADD ALTERNATE #A1. IFTHIS ALTERNATES IS NOT ACCEPTED, THIS SPACE WILL BEOPEN TO ABOVE. REFER TO ARCHITECTURAL DRAWINGSFOR ADDITIONAL ALTERNATE INFORMATION ANDREQUIREMENTS.
CIRCUIT RESTROOM EXHAUST FAN WITH RESTROOMLIGHTING FOR ON/OFF CONTROL OF EXHAUST FAN.
DAYLIGHT ZONE.
FLAG NOTES:#
1.
1. CEILING MOUNTED OCCUPANCY SENSOR SHALL BEWATT-STOPPER #DT-305 DUAL TECHNOLOGYOCCUPANCY SENSOR. PROVIDE POWER PACKS ASREQUIRED. THE LOWER CASE LETTER NEXT TOOCCUPANCY SENSORS INDICATE SWITCHINGFUNCTION CEILING MOUNTED OCCUPANCY SENSORSHALL CONTROL.
2. THE LOWER CASE LETTERS NEXT TO LIGHT FIXTURESINDICATES SWITCHING FUNCTION FOR LIGHTFIXTURE. THE LOWER CASE LETTERS NEXT TOSWITCHES INDICATE LIGHT FIXTURES LIGHTINGCONTROL DEVICE SHALL CONTROL.
3. THE NUMBERS NEXT TO ELECTRICAL DEVICESINDICATE THE CIRCUIT POSITION THAT THE BRANCHCIRCUIT SHALL OCCUPY IN PANEL "D" UNLESS NOTEDOTHERWISE.
4. ALL DIMMERS SHALL BE LUTRON #DVSTV UNLESSNOTED OTHERWISE.
5. ALL CONDUIT IN EXPOSED AREAS SHALL BE EMT ANDSHALL BE PAINTED TO MATCH SURROUNDINGSURFACES.