RENEWAL PARTS YPAL CONTROL PANELS Supersedes: Nothing Form 100.50-RP1 (404) UNIT COMPONENTS YPAL CONTROL PANELS
RENEWAL PARTS
YPAL CONTROL PANELS
Supersedes: Nothing Form 100.50-RP1 (404)
UNIT COMPONENTSYPAL CONTROL PANELS
2 YORK INTERNATIONAL
FORM 100.50-RP1 (404)
TABLE OF CONTENTSSECTION 1 - FAN SUB PANELS 50-95 TON VARIABLE AIR VOLUME (VAV) SUPPLY FAN
208V - 230V UNITS 10 TO 60 HP (SEE FIGURE 1) ....................................................................................... 6
380V-60 HZ - 400V-50 HZ UNITS 10 TO 60 HP (SEE FIGURE 1) ................................................................. 6
460V UNITS 10 TO 60 HP (SEE FIGURE 2) .................................................................................................. 6
575V UNITS 10 TO 60 HP (SEE FIGURE 2) .................................................................................................. 6
CONSTANT VOLUME (CV) SUPPLY FAN208V UNIT 10 TO 25 HP (SEE FIGURE 3) ..................................................................................................... 9
208V UNIT 30 TO 60 HP (SEE FIGURE 4) ..................................................................................................... 9
230V UNIT 10 TO 30 HP (SEE FIGURE 3) ..................................................................................................... 9
230V UNIT 40 TO 60 HP (SEE FIGURE 4) ..................................................................................................... 9
380V-60 HZ UNIT 10 TO 50 HP (SEE FIGURE 3) ........................................................................................ 10
400V-50 HZ UNIT 10 TO 50 HP (SEE FIGURE 3) ........................................................................................ 10
400V-50 HZ UNIT 60 HP (SEE FIGURE 4) ................................................................................................... 10
380V-60 HZ UNIT 60 HP (SEE FIGURE 4) ................................................................................................... 10
460V UNIT 10 TO 60 HP (SEE FIGURE 3) ................................................................................................... 11
575V UNIT 10 TO 60 HP (SEE FIGURE 3) ................................................................................................... 11
CONSTANT VOLUME (CV) EXHAUST FAN208V UNIT (SEE FIGURE 5) ........................................................................................................................ 14
208V UNIT (SEE FIGURE 6) ........................................................................................................................ 14
230V UNITS (SEE FIGURE 5) ...................................................................................................................... 14
380V-60 HZ UNITS (SEE FIGURE 5) ........................................................................................................... 14
400V-50 HZ UNITS (SEE FIGURE 5) ........................................................................................................... 15
460V UNITS (SEE FIGURE 5) ...................................................................................................................... 15
575V UNITS (SEE FIGURE 5) ...................................................................................................................... 15
VARIABLE AIR VOLUME (VAV) EXHAUST FAN208V AND 230V UNITS (SEE FIGURE 7) ................................................................................................... 18
380V-60 HZ OR 400V-50 HZ UNITS (SEE FIGURE 8) ................................................................................ 18
460V OR 575V UNITS (SEE FIGURE 7) ..................................................................................................... 18
SECTION 2 - POWER PANELS 50-95 TON50 - 55 TON UNIT CONTROL PANEL AND POWER PANEL ....................................................................... 22
60 - 65 TON UNIT CONTROL PANEL AND POWER PANEL ....................................................................... 23
70 - 75 TON UNIT CONTROL PANEL AND POWER PANEL ....................................................................... 24
80 - 85 TON UNIT CONTROL PANEL AND POWER PANEL ....................................................................... 25
90 - 95 TON UNIT CONTROL PANEL AND POWER PANEL ....................................................................... 26
CIRCUIT BREAKER OR DISCONNECT SWITCH ASSEMBLIES208V UNITS 50-75 TON ............................................................................................................................. 30
208V UNITS 80-95 TON .............................................................................................................................. 30
230V UNITS 50-75 TON ................................................................................................................................ 30
380V-60 HZ UNITS 50-85 TON ..................................................................................................................... 31
230V UNITS 80-95 TON ................................................................................................................................ 31
380V-60 HZ UNITS 90 TON .......................................................................................................................... 31
400V-50 HZ UNITS 50-75 TON ..................................................................................................................... 32
460V UNITS 50-75 TON ................................................................................................................................ 32
400V-50 HZ UNITS 80-95 TON ..................................................................................................................... 32
460V UNITS 80-95 TON ................................................................................................................................ 33
575V UNITS 50-95 TON ................................................................................................................................ 33
YORK INTERNATIONAL 3
FORM 100.50-RP1 (404)
MICRO-PANEL MICRO-PANEL PARTS ................................................................................................................................. 34
SECTION 3 - UNIQUE PANEL KITS
GAS HEAT KIT208V UNITS .................................................................................................................................................. 36
230V UNITS .................................................................................................................................................. 36
380V - 400V UNITS ....................................................................................................................................... 36
460V UNITS .................................................................................................................................................. 36
575V UNITS .................................................................................................................................................. 36
CONVENIENCE OUTLET KITCONVENIENCE OUTLET KIT UNIQUE PARTS ........................................................................................... 38
CONVENIENCE OUTLET KIT COMMON PARTS ........................................................................................ 38
LANGUAGE KITLANGUAGE KIT ............................................................................................................................................ 40
VFD FAN KEYPAD PANELVFD FAN KEYPAD PANEL PARTS ............................................................................................................... 41
208V UNITS ................................................................................................................................................. 42
ELECTRIC HEAT POWER SUPPLY BOX KIT TERMINAL BLOCK BOXES
230V UNITS .................................................................................................................................................. 42
380V-60 HZ UNITS ........................................................................................................................................ 43
400V-50 HZ UNITS ........................................................................................................................................ 43
460V UNITS .................................................................................................................................................. 44
575V UNITS .................................................................................................................................................. 44
ELECTRIC HEAT POWER SUPPLY BOX KIT DISCONNECT SWITCH BOXES
208V UNITS .................................................................................................................................................. 47
230V UNITS .................................................................................................................................................. 47
380V-60V UNITS ........................................................................................................................................... 48
400V-50V UNITS ........................................................................................................................................... 48
460V UNITS .................................................................................................................................................. 49
575V UNITS .................................................................................................................................................. 49
MICRO HARNESS CONNECTORS .................................................................................................... 52
SUPPLY FAN MOTOR FUSES .............................................................................................................. 53
EXHAUST FAN MOTOR VFD FUSES ............................................................................................... 54
ELECTRIC HEATER COIL FUSES ..................................................................................................... 55
TABLE OF CONTENTS (CONT'D)
4 YORK INTERNATIONAL
FORM 100.50-RP1 (404)
FIG. 1 – VAV SUPPLY FAN ............................................................................................................................ 7
FIG. 2 – VAV SUPPLY FAN ............................................................................................................................ 8
FIG. 3 – CV SUPPLY FAN ............................................................................................................................ 12
FIG. 4 – CV SUPPLY FAN ............................................................................................................................ 13
FIG. 5 – CV EXHAUST FAN .......................................................................................................................... 16
FIG. 6 – CV EXHAUST FAN .......................................................................................................................... 17
FIG. 7 – VAV EXHAUST FAN ........................................................................................................................ 19
FIG. 8 – VAV EXHAUST FAN ........................................................................................................................ 20
FIG. 9 – POWER PANEL ............................................................................................................................... 28
FIG. 9A – STAND-OFF SUB PANEL ............................................................................................................. 29
FIG. 10 – MICRO-PANEL ASSEMBLY .......................................................................................................... 35
FIG. 11 – GAS HEAT KIT ............................................................................................................................... 37
FIG. 12 – CONVENIENCE OUTLET KIT ....................................................................................................... 38
FIG. 13 – GAS HEAT PANEL ........................................................................................................................ 39
FIG. 14 – LANGUAGE KIT ............................................................................................................................ 40
FIG. 15 – VFD FAN KEYPAD PANEL ............................................................................................................ 41
FIG. 16 – ELECTRIC HEAT KIT .................................................................................................................... 45
FIG. 17 – ELECTRIC HEAT KIT .................................................................................................................... 46
FIG. 18 – ELECTRIC HEAT KIT .................................................................................................................... 50
FIG. 19 – ELECTRIC HEAT KIT .................................................................................................................... 51
TABLE 1 - SUPPLY FAN FUSES .................................................................................................................. 53
TABLE 2 - EXHAUST FAN MOTOR VFD FUSES ......................................................................................... 54
TABLE 3 - ELECTRIC HEATER COIL FUSES .............................................................................................. 55
LIST OF FIGURES AND TABLES
YORK INTERNATIONAL 5
FORM 100.50-RP1 (404)
BASIC MODEL NUMBER
PRODUCTYPE
Y = YorkP = Packaged RooftopA = Air-CooledL = Scroll Compressor
NOMINAL CAPACITY
050 = 50-ton055 = 55-ton060 = 60-ton065 = 65-ton070 = 70-ton075 = 75-ton080 = 80-ton085 = 85-ton090 = 90-ton095 = 95-ton
UNIT TYPE
C = Cooling OnlyN = Natural Gas HeatG = Natural Gas Heat, SS HXE = Electric HeatH = Hot Water HeatS = Steam Heat
UNIT FUNCTION
C = Constant VolumeV = VAV, VFDF = Flexsys
REFRIGERANT
B = R-407CC = R-22
VOLTAGE
17 = 200/3/60 28 = 230/3/60 46 = 460/3/60 58 = 575/3/60 40 = 380/3/60
DESIGN SPECIALS
X = SpecialS = Standard Product
REVISION LEVEL
B = Current Revision
SUPPLY DUCT LOCATIONS
B = BottomL = LeftR = Right
RETURN DUCT LOCATIONS
B = BottomR = RightS = Side
Y P A L 0 6 0 N V B 4 6 B B A S 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
6 YORK INTERNATIONAL
FORM 100.50-RP1 (404)
SECTION 1 - FAN SUB PANELS 50-95 TON
VARIABLE AIR VOLUME (VAV) SUPPLY FAN
Fan Sub-Panels 50-95 Ton
208V - 230V UNITS 10 TO 60 HP (SEE FIGURE 1)
ITEM DESCRIPTIONSupply Fan HP
10-15 20-30 40-60 40-60*
2B 7FU, Fuse Block 025-37608-000 025-37609-000 025-37610-000 025-37607-000
2I Ground Lug 025-34455-000 025-34455-000 025-34088-000 025-34089-000
4 10R, Control Relay 024-31885-000 024-31885-000 024-31885-000 024-31885-000
* Only used when the unit is equipped with a 30 HP Exhaust Fan.
380V-60 HZ - 400V-50 HZ UNITS 10 TO 60 HP (SEE FIGURE 1)
ITEM DESCRIPTIONSupply Fan HP
10-15 20-30 40-50 60
2B 7FU, Fuse Block 025-37635-000 025-37608-000 025-37609-000 025-37610-000
2I Ground Lug 025-34455-000 025-34455-000 025-34455-000 025-34088-000
4 10R, Control Relay 024-31885-000 024-31885-000 024-31885-000 024-31885-000
460V UNITS 10 TO 60 HP (SEE FIGURE 2)
ITEM DESCRIPTIONSupply Fan HP
10-20 25-40 50-60
2B 7FU, Fuse Block 025-37635-000 025-37608-000 025-37609-000
2I Ground Lug 025-34455-000 025-34455-000 025-34455-000
4 10R, Control Relay 024-31885-000 024-31885-000 024-31885-000
575V UNITS 10 TO 60 HP (SEE FIGURE 2)
ITEM DESCRIPTIONSupply Fan HP
10-20 25-50 60
2B 7FU, Fuse Block 025-37635-000 025-37608-000 025-37609-000
2I Ground Lug 025-34455-000 025-34455-000 025-34455-000
4 10R, Control Relay 024-31885-000 024-31885-000 024-31885-000
Fuse information can be located in Table 1 on page 53.
YORK INTERNATIONAL 7
FORM 100.50-RP1 (404)
LD09187
FIG. 1 – VAV SUPPLY FAN
11
NOTE: Exhaust fan components may not be included on this drawing.
8 YORK INTERNATIONAL
FORM 100.50-RP1 (404)
LD09188
FIG. 2 – VAV SUPPLY FAN
Fan Sub-Panels 50-95 Ton
NOTE: Exhaust fan components may not be included on this drawing.
YORK INTERNATIONAL 9
FORM 100.50-RP1 (404)
11CONSTANT VOLUME (CV) SUPPLY FAN
208V UNIT 10 TO 25 HP (SEE FIGURE 3)
ITEM DESCRIPTIONSupply Fan HP
10 15-20 25
2A 13M, Contactor 024-34308-000 024-34310-000 024-31109-000
2B 13CB/OL, Manual Starter 024-31816-000 025-34488-000 024-33131-000
2C Surge Suppressor 031-02101-000 031-02101-000 031-02203-000
2E Ground Lug 025-34455-000 025-34455-000 025-34455-000
2G 13OL, Relay N/A N/A N/A
4 10R, Control Relay 024-31885-000 024-31885-000 024-31885-000
230V UNIT 10 TO 30 HP (SEE FIGURE 3)
ITEM DESCRIPTIONSupply Fan HP
10-15 20-25 30
2A 13M, Contactor 024-34308-000 024-34310-000 024-31109-000
2B 13CB/OL, Manual Starter 024-31816-000 025-34488-000 024-33131-000
2C Surge Suppressor 031-02101-000 031-02101-000 031-02203-000
2E Ground Lug 025-34455-000 025-34455-000 025-34455-000
2G 13OL, Relay N/A N/A N/A
4 10R, Control Relay 024-31885-000 024-31885-000 024-31885-000
208V UNIT 30 TO 60 HP (SEE FIGURE 4)
ITEM DESCRIPTIONSupply Fan HP
30 40 50-60
2A 13M, Contactor 024-31110-000 024-31891-000 024-31892-000
2B 13FU, Fuse Block 025-37610-000 025-37610-000 025-37610-000
2C Surge Suppressor 031-02203-000 031-02203-000 031-02203-000
2E Ground Lug 025-34088-000 025-34088-000 025-34089-000
2G 13OL, Relay 024-33133-000 024-34295-000 024-34296-000
4 10R, Control Relay 024-31885-000 024-31885-000 024-31885-000
230V UNIT 40 TO 60 HP (SEE FIGURE 4)
ITEM DESCRIPTIONSupply Fan HP
40 50 60
2A 13M, Contactor 024-31110-000 024-31891-000 024-31892-000
2B 13FU, Fuse Block 025-37610-000 025-37610-000 025-37610-000
2C Surge Suppressor 031-02203-000 031-02203-000 031-02203-000
2E Ground Lug 025-34088-000 025-34088-000 025-34089-000
2G 13OL, Relay 024-33133-000 024-34295-000 024-34296-000
4 10R, Control Relay 024-31885-000 024-31885-000 024-31885-000
Fuse information can be located in Table 1 on page 53.
10 YORK INTERNATIONAL
FORM 100.50-RP1 (404)
380V-60 HZ UNIT 10 TO 50 HP (SEE FIGURE 3)
ITEM DESCRIPTIONSupply Fan HP
10 15 20-25 30-40 50
2A 13M, Contactor 024-34305-000 024-34306-000 024-34308-000 024-34310-000 024-31109-000
2B 13CB/OL, Manual Starter 024-33181-000 024-33182-000 024-31816-000 025-34488-000 024-33131-000
2C Surge Suppressor 031-02104-000 031-02104-000 031-02101-000 031-02101-000 031-02203-000
2E Ground Lug 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
2G 13OL, Relay N/A N/A N/A N/A N/A
4 10R, Control Relay 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
400V-50 HZ UNIT 10 TO 50 HP (SEE FIGURE 3)
ITEM DESCRIPTIONSupply Fan HP
10 15 20 25-40 50
2A 13M, Contactor 024-34304-000 024-34306-000 024-34308-000 024-34310-000 024-31109-000
2B 13CB/OL, Manual Starter 024-33180-000 024-33182-000 024-31816-000 025-34488-000 024-33131-000
2C Surge Suppressor 031-02104-000 031-02104-000 031-02101-000 031-02101-000 031-02203-000
2E Ground Lug 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
2G 13OL, Relay N/A N/A N/A N/A N/A
4 10R, Control Relay 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
CONSTANT VOLUME (CV) SUPPLY FAN (CONT'D)
380V-60 HZ UNIT 60 HP (SEE FIGURE 4)
ITEM DESCRIPTIONSupply Fan HP
60
2A 13M, Contactor 024-31110-000
2B 13FU, Fuse Block 025-37610-000
2C Surge Suppressor 031-02203-000
2E Ground Lug 025-34088-000
2G 13OL, Relay 024-33133-000
4 10R, Control Relay 024-31885-000
400V-50 HZ UNIT 60 HP (SEE FIGURE 4)
ITEM DESCRIPTIONSupply Fan HP
60
2A 13M, Contactor 024-31110-000
2B 13FU, Fuse Block 025-37610-000
2C Surge Suppressor 031-02203-000
2E Ground Lug 025-34088-000
2G 13OL, Relay 024-33133-000
4 10R, Control Relay 024-31885-000
Fuse information can be located in Table 1 on page 53.
YORK INTERNATIONAL 11
FORM 100.50-RP1 (404)
11460V UNIT 10 TO 60 HP (SEE FIGURE 3)
ITEM DESCRIPTIONSupply Fan HP
10 15 20 25-30 40-50 60
2A 13M, Contactor 024-34304-000 024-34305-000 024-34306-000 024-34308-000 024-34310-000 024-31109-000
2B 13CB/OL, Manual Starter 024-33180-000 024-33181-000 024-33182-000 024-31816-000 025-34488-000 024-33131-000
2C Surge Suppressor 031-02104-000 031-02104-000 031-02104-000 031-02101-000 031-02101-000 031-02203-000
2E Ground Lug 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
4 10R, Control Relay 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
575V UNIT 10 TO 60 HP (SEE FIGURE 3)
ITEM DESCRIPTIONSupply Fan HP
10 15 20 25 30-40 50-60
2A 13M, Contactor 024-34304-000 024-34304-000 024-34305-000 024-34306-000 024-34308-000 024-34310-000
2B 13CB/OL, Manual Starter 024-33179-000 025-33180-000 024-33181-000 025-33182-000 025-31816-000 025-34488-000
2C Surge Suppressor 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02101-000 031-02101-000
2E Ground Lug 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
4 10R, Control Relay 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
CONSTANT VOLUME (CV) SUPPLY FAN (CONT'D)
Fuse information can be located in Table 1 on page 53.
12 YORK INTERNATIONAL
FORM 100.50-RP1 (404)Fan Sub-Panels 50-95 Ton
LD09216
FIG. 3 – CV SUPPLY FAN
NOTE: Exhaust fan components may also be included on this drawing.
YORK INTERNATIONAL 13
FORM 100.50-RP1 (404)
11
LD09223
FIG. 4 – CV SUPPLY FAN
NOTE: Exhaust fan components may also be included on this drawing.
14 YORK INTERNATIONAL
FORM 100.50-RP1 (404)
CONSTANT VOLUME (CV) EXHAUST FAN
208V UNIT (SEE FIGURE 5)
ITEM DESCRIPTIONEXHAUST FAN HP
5 7.5 10 15-20 253A 14M, Contactor 024-34304-000 024-34306-000 024-34308-000 024-34310-000 024-31109-000
3B 14CB/OL, Manual Starter 024-33180-000 024-33182-000 024-31816-000 025-34488-000 024-33131-000
3C Surge Suppressor 031-02104-000 031-02104-000 031-02101-000 031-02101-000 031-02203-000
3E Ground Lug 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
4 11R, Relay 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
380V-60 HZ UNITS (SEE FIGURE 5)
ITEM DESCRIPTIONEXHAUST FAN HP
5 7.5 10 15 20-25 30
3A 14M, Contactor 024-34300-000 024-34304-000 024-34305-000 024-34306-000 024-34308-000 024-34310-000
3B 14CB/OL, Manual Starter 024-33178-000 024-33180-000 024-33181-000 024-33182-000 024-31816-000 025-34488-000
3C Surge Suppressor 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02101-000 031-02101-000
3E Ground Lug 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
4 11R, Relay 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
208V UNIT (SEE FIGURE 6)
ITEM DESCRIPTIONEXHAUST FAN HP
30 30*3A 14M, Contactor 024-31110-000 024-31110-000
3B 14FU, Fuse Holder 025-37610-000 025-37610-000
3C Surge Suppressor 031-02203-000 031-02203-000
3E Ground Lug 025-34088-000 025-34088-000
3G 14O/L, Relay 024-33133-000 024-33133-000
4 11R, Relay 024-31885-000 024-31885-000
* Only used when the unit is equipped with a 40-60 HP Supply Fan.
230V UNITS (SEE FIGURE 5)
ITEM DESCRIPTIONEXHAUST FAN HP
5 7.5 10-15 20-25 303A 14M, Contactor 024-34304-000 024-34306-000 024-34308-000 024-34310-000 024-31109-000
3B 14CB/OL, Manual Starter 024-33180-000 024-33182-000 024-31816-000 024-34488-000 024-33131-000
3C Surge Suppressor 031-02104-000 031-02104-000 031-02101-000 031-02101-000 031-02203-000
3E Ground Lug 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
4 11R, Relay 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
Fan Sub-Panels 50-95 Ton
Fuse information can be located in Table 2 on page 54.
YORK INTERNATIONAL 15
FORM 100.50-RP1 (404)
400V-50 HZ UNITS (SEE FIGURE 5)
ITEM DESCRIPTIONEXHAUST FAN HP
5 7.5 10 15 20 25-303A 14M, Contactor 024-34300-000 024-34304-000 024-34304-000 024-34306-000 024-34308-000 024-34310-000
3B 14CB/OL, Manual Starter 024-33178-000 024-33179-000 024-33180-000 024-33182-000 024-31816-000 025-34488-000
3C Surge Suppressor 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02101-000 031-02101-000
3E Ground Lug 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
4 11R 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
460V UNITS (SEE FIGURE 5)
ITEM DESCRIPTIONEXHAUST FAN HP
5 7.5 10 15 20 25-303A 14M, Contactor 024-34300-000 024-34304-000 024-34304-000 024-34305-000 024-34306-000 024-34308-000
3B 14CB/OL, Manual Starter 024-33178-000 024-33179-000 024-33180-000 024-33181-000 024-33182-000 024-31816-000
3C Surge Suppressor 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02101-000
3E Ground Lug 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
4 11R 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
575V UNITS (SEE FIGURE 5)
ITEM DESCRIPTIONEXHAUST FAN HP
5 7.5-10 15 20 25 30
3A 14M, Contactor 024-34302-000 024-34304-000 024-34304-000 024-34305-000 024-34306-000 024-34308-000
3B 14CB/OL, Manual Starter 024-33169-000 024-33179-000 024-33180-000 024-33181-000 024-33182-000 024-31816-000
3C Surge Suppressor 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02101-000
3E Ground Lug 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
4 11R 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
CONSTANT VOLUME (CV) EXHAUST FAN (CONT'D)
11
Fuse information can be located in Table 2 on page 54.
16 YORK INTERNATIONAL
FORM 100.50-RP1 (404)
LD09191
FIG. 5 – CV EXHAUST FAN
Fan Sub-Panels 50-95 Ton
NOTE: Supply fan components may also be included on this drawing.
YORK INTERNATIONAL 17
FORM 100.50-RP1 (404)
11
LD09192
FIG. 6 – CV EXHAUST FANNOTE: Supply fan components may also be included on this drawing.
18 YORK INTERNATIONAL
FORM 100.50-RP1 (404)Fan Sub-Panels 50-95 Ton
VARIABLE AIR VOLUME (VAV) EXHAUST FAN
208V AND 230V UNITS (SEE FIGURE 7)
ITEM DESCRIPTIONEXHAUST FAN HP
5-7.5 10-15 20-303B 8FU, Fuse Holder 025-37635-000 025-37608-000 025-37609-000
3I Ground Lug 025-34455-000 025-34455-000 025-34455-000
4 11R, Relay 024-31885-000 024-31885-000 024-31885-000
380V-60 HZ OR 400V-50 HZ UNITS (SEE FIGURE 8)
ITEM DESCRIPTIONEXHAUST FAN HP
5-15 20-303B 8FU, Fuse Holder 025-37635-000 025-37608-000
3I Ground Lug 025-34455-000 025-34455-000
4 11R, Relay 024-31885-000 024-31885-000
460V OR 575V UNITS (SEE FIGURE 7)
ITEM DESCRIPTIONEXHAUST FAN HP
5-20 25-303B 8FU, Fuse Holder 025-37635-000 025-37608-000
3I Ground Lug 025-34455-000 025-34455-000
4 11R, Relay 024-31885-000 024-31885-000
Fuse information can be located in Table 2 on page 54.
YORK INTERNATIONAL 19
FORM 100.50-RP1 (404)
11
LD09194
FIG. 7 – VAV EXHAUST FAN
NOTE: Supply fan components may also be included on this drawing.
20 YORK INTERNATIONAL
FORM 100.50-RP1 (404)Fan Sub-Panels 50-95 Ton
LD09197
FIG. 8 – VAV EXHAUST FAN
NOTE: Exhaust fan components may also be included on this drawing.
22 YORK INTERNATIONAL
FORM 100.50-RP1 (404)
SECTION 2 - POWER PANELS 50-95 TON
50 - 55 TON UNIT CONTROL PANEL AND POWER PANEL
Control and Power Panels
Item Qty Description SeeFigure 208V 230V 380V 400V-50 Hz 460V 575V
5A 2 Contactor 9 024-34309-000 024-34309-000 024-34307-000 024-34306-000 024-34306-000 024-34305-000
5B 2 Over Load (OL) 9 025-34488-000 025-34488-000 024-31816-000 024-33182-000 024-33182-000 024-33181-000
5C 2 Surge Supressor 9 031-02101-000 031-02101-000 031-02101-000 031-02104-000 031-02104-000 031-02104-0005E 2 Ground Lug 9 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-0006A 2 Contactor 9 024-34309-000 024-34309-000 024-34307-000 024-34306-000 024-34306-000 024-34305-000
6B 2 Over Load (OL) 9 025-34488-000 025-34488-000 024-31816-000 024-33182-000 024-33182-000 024-33181-000
6C 2 Surge Supressor 9 031-02101-000 031-02101-000 031-02101-000 031-02104-000 031-02104-000 031-02104-000
6E 2 Ground Lug 9 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
8A 4 Surge Supressor 9 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02104-000
8B 4 Contactor 9 024-34302-000 024-34302-000 024-34302-000 024-34302-000 024-34302-000 024-34302-000
8C 2 Fuseblock 9A 025-34185-000 025-34185-000 025-34185-000 025-34185-000 025-34185-000 025-34185-000
8D 6 Fuse, 600V 9A 025-34142-000 025-34142-000 025-38396-000 025-37618-000 025-38396-000 025-37613-000
11A 2 Relay, Control 9 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
11B 2 Aux Contact Block 9 025-35694-000 025-35694-000 025-35694-000 025-35694-000 025-35694-000 025-35694-000
11C See Below
13A 2 Fuse, 600V 9A 025-34430-000 025-37629-000 025-35902-000 025-37659-000 025-37611-000 025-35911-000
13B 1 Fuseblock 9A 025-34427-000 025-34427-000 025-34427-000 025-35667-000 025-34427-000 025-34427-000
13D 1 Transformer 9 025-38388-000 025-38387-000 025-38390-000 025-38390-000 025-38387-000 025-38389-000
13E 1 Fuseblock 9A 025-35667-000 025-35667-000 025-35667-000 025-35667-000 025-35667-000 025-35667-000
13F 1 Fuse, 10 Amp 9A 025-28966-006 025-28966-006 025-28966-006 025-28966-006 025-28966-006 025-28966-006
13G 1 Fuse, 4 Amp 9A 025-37626-000 025-37626-000 025-37626-000 025-37626-000 025-37626-000 025-37626-000
14 1 Smart Relay 9 025-36414-001 025-36414-001 025-36414-001 025-36414-001 025-36414-001 025-36414-001
15 1 Relay Expansion 9 025-36043-000 025-36043-000 025-36043-000 025-36043-000 025-36043-000 025-36043-000
- 4 Aux. Contact Block - 024-34320-000 024-34320-000 024-34320-000 024-34320-000 024-34320-000 024-34320-000
- 1 Terminal Board - 025-36388-003 025-36388-003 025-36388-003 025-36388-003 025-36388-003 025-36388-003
25 1 Thermostat 9, 9A 025-36346-001 025-36346-001 025-36346-001 025-36346-001 025-36346-001 025-36346-001
MOD A MANEUROP COMPRESSORS
11C 2 Relay, Control 9 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
MOD B COPELAND COMPRESSORS
11C2 Relay, Control 9 024-31635-000 024-31635-000 024-31635-000 024-31635-000 024-31635-000 024-31635-000
2 Relay, Control 9 024-33177-000 024-33177-000 024-33177-000 024-33177-000 024-33177-000 024-33177-000
2 Surge Supressor 9 031-02107-000 031-02107-000 031-02107-000 031-02107-000 031-02107-000 031-02107-000
LITERATURE SUPPLEMENT File with: 100.50-RP1 (404)
Form Number: 100.50-RP1 (LS01) 205
Supersedes: None
Subject: The following tables contain revised YPAL power panel part numbers (change rows are highlighted)
SECTION 2 - POWER PANELS 50-95 TON
50 - 55 TON UNIT CONTROL PANEL AND POWER PANEL (100.50-RP1 PAGE 22)
Item Qty Description SeeFigure 208V 230V 380V 400V-50 Hz 460V 575V
5A 2 Contactor 9 024-34309-000 024-34309-000 024-34307-000 024-34306-000 024-34306-000 024-34305-000
5B 2 Over Load (OL) 9 025-34488-000 025-34488-000 024-31816-000 024-33182-000 024-33182-000 024-33181-000
5C 2 Surge Supressor 9 031-02101-000 031-02101-000 031-02101-000 031-02104-000 031-02104-000 031-02104-0005E 2 Ground Lug 9 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-0006A 2 Contactor 9 024-34309-000 024-34309-000 024-34307-000 024-34306-000 024-34306-000 024-34305-000
6B 2 Over Load (OL) 9 025-34488-000 025-34488-000 024-31816-000 024-33182-000 024-33182-000 024-33181-000
6C 2 Surge Supressor 9 031-02101-000 031-02101-000 031-02101-000 031-02104-000 031-02104-000 031-02104-000
6E 2 Ground Lug 9 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
8A 4 Surge Supressor 9 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02104-000
8B 4 Contactor 9 024-34302-000 024-34302-000 024-34302-000 024-34302-000 024-34302-000 024-34302-000
8C 2 Fuseblock 9A 025-34185-000 025-34185-000 025-34185-000 025-34185-000 025-34185-000 025-34185-000
8D 6 Fuse, 600V 9A 025-34142-000 025-34142-000 025-38396-000 025-37618-000 025-38396-000 025-37613-000
11A 2 Relay, Control 9 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
11B 2 Aux Contact Block 9 025-35694-000 025-35694-000 025-35694-000 025-35694-000 025-35694-000 025-35694-000
11C See Below
13A 2 Fuse, 600V 9A 025-34430-000 025-37629-000 025-35902-000 025-37659-000 025-37611-000 025-35911-000
13B 1 Fuseblock 9A 025-34427-000 025-34427-000 025-34427-000 025-35667-000 025-34427-000 025-34427-000
13D 1 Transformer 9 025-38388-000 025-38387-000 025-38390-000 025-38390-000 025-38387-000 025-38389-000
13E 1 Fuseblock 9A 025-35667-000 025-35667-000 025-35667-000 025-35667-000 025-35667-000 025-35667-000
13F 1 Fuse, 10 Amp 9A 025-28966-006 025-28966-006 025-28966-006 025-28966-006 025-28966-006 025-28966-006
13G 1 Fuse, 4 Amp 9A 025-37626-000 025-37626-000 025-37626-000 025-37626-000 025-37626-000 025-37626-000
14 1 Smart Relay 9 025-36414-001 025-36414-001 025-36414-001 025-36414-001 025-36414-001 025-36414-001
15 1 Relay Expansion 9 025-36403-000 025-36403-000 025-36403-000 025-36403-000 025-36403-000 025-36403-000
- 4 Aux. Contact Block - 024-34320-000 024-34320-000 024-34320-000 024-34320-000 024-34320-000 024-34320-000
- 1 Terminal Board - 025-36388-003 025-36388-003 025-36388-003 025-36388-003 025-36388-003 025-36388-003
25 1 Thermostat 9, 9A 025-36346-001 025-36346-001 025-36346-001 025-36346-001 025-36346-001 025-36346-001
MOD A MANEUROP COMPRESSORS
11C 2 Relay, Control 9 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
MOD B COPELAND COMPRESSORS
11C2 Relay, Control 9 024-31635-000 024-31635-000 024-31635-000 024-31635-000 024-31635-000 024-31635-000
2 Relay, Control 9 024-33177-000 024-33177-000 024-33177-000 024-33177-000 024-33177-000 024-33177-000
2 Surge Supressor 9 031-02107-000 031-02107-000 031-02107-000 031-02107-000 031-02107-000 031-02107-000
YORK INTERNATIONAL2
FORM 160.69-M1 (LS01)
YORK INTERNATIONAL 3
FORM 160.69-M1 (LS01)
Item Qty Description SeeFigure 208V 230V 380V 400V-50 Hz 460V 575V
5A 2 Contactor 9 024-34310-000 024-34310-000 024-34308-000 024-34307-000 024-34307-000 024-34306-000
5B 2 Over Load (OL) 9 025-34488-000 025-34488-000 024-31816-000 024-31816-000 024-31816-000 024-33182-000
5C 2 Surge Supressor 9 031-02101-000 031-02101-000 031-02101-000 031-02101-000 031-02101-000 031-02104-0005E 2 Ground Lug 9 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-0006A 2 Contactor 9 024-34310-000 024-34310-000 024-34308-000 024-34307-000 024-34307-000 024-34306-000
6B 2 Over Load (OL) 9 025-34488-000 025-34488-000 024-31816-000 024-31816-000 024-31816-000 024-33182-000
6C 2 Surge Supressor 9 031-02101-000 031-02101-000 031-02101-000 031-02101-000 031-02101-000 031-02104-000
6E 2 Ground Lug 9 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
8A 4 Surge Supressor 9 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02104-000
8B 4 Contactor 9 024-34302-000 024-34302-000 024-34302-000 024-34302-000 024-34302-000 024-34302-000
8C 2 Fuseblock 9A 025-34185-000 025-34185-000 025-34185-000 025-34185-000 025-34185-000 025-34185-000
8D 6 Fuse, 600V 9A 025-34142-000 025-34142-000 025-38396-000 025-37618-000 025-38396-000 025-37613-000
11A 2 Relay, Control 9 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
11B 2 Aux Contact Block 9 025-35694-000 025-35694-000 025-35694-000 025-35694-000 025-35694-000 025-35694-000
11C See Below
13A 2 Fuse, 600V 9A 025-34430-000 025-37629-000 025-35902-000 025-37659-000 025-37611-000 025-35911-000
13B 1 Fuseblock 9A 025-34427-000 025-34427-000 025-34427-000 025-35667-000 025-34427-000 025-34427-000
13D 1 Transformer 9 025-38388-000 025-38387-000 025-38390-000 025-38390-000 025-38387-000 025-38389-000
13E 1 Fuseblock 9A 025-35667-000 025-35667-000 025-35667-000 025-35667-000 025-35667-000 025-35667-000
13F 1 Fuse, 10 Amp 9A 025-28966-006 025-28966-006 025-28966-006 025-28966-006 025-28966-006 025-28966-006
13G 1 Fuse, 4 Amp 9A 025-37626-000 025-37626-000 025-37626-000 025-37626-000 025-37626-000 025-37626-000
14 1 Smart Relay 9 025-36414-001 025-36414-001 025-36414-001 025-36414-001 025-36414-001 025-36414-001
15 1 Relay Expansion 9 025-36403-000 025-36403-000 025-36403-000 025-36403-000 025-36403-000 025-36403-000
- 4 Aux. Contact Block - 024-34320-000 024-34320-000 024-34320-000 024-34320-000 024-34320-000 024-34320-000
- 1 Terminal Board - 025-36388-003 025-36388-003 025-36388-003 025-36388-003 025-36388-003 025-36388-003
25 1 Thermostat 9, 9A 025-36346-001 025-36346-001 025-36346-001 025-36346-001 025-36346-001 025-36346-001
MOD A MANEUROP COMPRESSORS
11C 2 Relay, Control 9 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
MOD B COPELAND COMPRESSORS
11C2 Relay, Control 9 024-31635-000 024-31635-000 024-31635-000 024-31635-000 024-31635-000 024-31635-000
2 Relay, Control 9 024-33177-000 024-33177-000 024-33177-000 024-33177-000 024-33177-000 024-33177-000
2 Surge Supressor 9 031-02107-000 031-02107-000 031-02107-000 031-02107-000 031-02107-000 031-02107-000
POWER PANELS 50-95 TON (CONT'D)
60 - 65 TON UNIT CONTROL PANEL AND POWER PANEL (100.50-RP1 PAGE 23)
YORK INTERNATIONAL2
FORM 160.69-M1 (LS01)
YORK INTERNATIONAL 3
FORM 160.69-M1 (LS01)
70 - 75 TON UNIT CONTROL PANEL AND POWER PANEL(100.50-RP1 PAGE 24)
Item Qty Description SeeFigure 208V 230V 380V 400V-50 Hz 460V 575V
5A 2 Contactor 9 024-34309-000 024-34308-000 024-34306-000 024-34305-000 024-34305-000 024-34304-000
5B 2 Over Load (OL) 9 025-34488-000 024-31816-000 024-33182-000 024-33181-000 024-33181-000 024-33180-000
5C 2 Surge Supressor 9 031-02101-000 031-02101-000 031-02104-000 031-02104-000 031-02104-000 031-02104-0005E 2 Ground Lug 9 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-0006A 2 Contactor 9 024-34309-000 024-34308-000 024-34306-000 024-34305-000 024-34305-000 024-34304-000
6B 2 Over Load (OL) 9 025-34488-000 024-31816-000 024-33182-000 024-33181-000 024-33181-000 024-33180-000
6C 2 Surge Supressor 9 031-02101-000 031-02101-000 031-02104-000 031-02104-000 031-02104-000 031-02100-000
6E 2 Ground Lug 9 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
7A 2 Contactor 9 024-34309-000 024-34309-000 024-34307-000 024-34306-000 024-34306-000 024-34305-000
7B 2 Over Load (OL) 9 025-34488-000 025-34488-000 024-31816-000 024-33182-000 024-33182-000 024-33181-000
7C 2 Surge Supressor 9 031-02101-000 031-02101-000 031-02101-000 031-02104-000 031-02104-000 031-02104-000
7E 2 Ground Lug 9 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
8A 6 Surge Supressor 9 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02104-000
8B 6 Contactor 9 024-34302-000 024-34302-000 024-34302-000 024-34302-000 024-34302-000 024-34302-000
8C 3 Fuseblock 9A 025-34185-000 025-34185-000 025-34185-000 025-34185-000 025-34185-000 025-34185-000
8D 9 Fuse, 600V 9A 025-34142-000 025-34142-000 025-38396-000 025-37618-000 025-38396-000 025-37613-000
11A 2 Relay, Control 9 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
11B 2 Aux Contact Block 9 025-35694-000 025-35694-000 025-35694-000 025-35694-000 025-35694-000 025-35694-000
11C See Below
13A 2 Fuse, 600V 9A 025-34435-000 025-34435-000 025-34431-000 025-37653-000 025-35902-000 025-37611-000
13B 1 Fuseblock 9A 025-34427-000 025-34427-000 025-34427-000 025-35667-000 025-34427-000 025-34427-000
13D 1 Transformer 9 025-38393-000 025-38391-000 025-38391-000 025-38392-000 025-38391-000 025-35652-000
13E 1 Fuseblock 9A 025-35667-000 025-35667-000 025-35667-000 025-35667-000 025-35667-000 025-35667-000
13F 1 Fuse, 12 Amp 9A 025-38360-000 025-38360-000 025-38360-000 025-38360-000 025-38360-000 025-38360-000
13G 1 Fuse, 5 Amp 9A 025-35689-000 025-35689-000 025-35689-000 025-35689-000 025-35689-000 025-35689-000
14 1 Smart Relay 9 025-36414-002 025-36414-002 025-36414-002 025-36414-002 025-36414-002 025-36414-002
15 2 Relay Expansion 9 025-36403-000 025-36403-000 025-36403-000 025-36043-000 025-36403-000 025-36403-000
- 4 Aux. Contact Block - 024-34320-000 024-34320-000 024-34320-000 024-34320-000 024-34320-000 024-34320-000
- 1 Terminal Board - 025-36416-000 025-36416-000 025-36416-000 025-36416-000 025-36416-000 025-36416-000
25 1 Thermostat 9, 9A 025-36346-001 025-36346-001 025-36346-001 025-36346-001 025-36346-001 025-36346-001
MOD A MANEUROP COMPRESSORS
11C 3 Relay, Control 9 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
MOD B COPELAND COMPRESSORS
11C3 Relay, Control 9 024-31635-000 024-31635-000 024-31635-000 024-31635-000 024-31635-000 024-31635-000
3 Relay, Control 9 024-33177-000 024-33177-000 024-33177-000 024-33177-000 024-33177-000 024-33177-000
3 Surge Supressor 9 031-02107-000 031-02107-000 031-02107-000 031-02107-000 031-02107-000 031-02107-000
POWER PANELS 50-95 TON (CONT'D)
YORK INTERNATIONAL4
FORM 160.69-M1 (LS01)
YORK INTERNATIONAL 5
FORM 160.69-M1 (LS01)
80 - 85 TON UNIT CONTROL PANEL AND POWER PANEL (100.50-RP1 PAGE 25)
Item Qty Description SeeFigure 208V 230V 380V 400V-50 Hz 460V 575V
5A 2 Contactor 9 024-34309-000 024-34309-000 024-34307-000 024-34306-000 024-34306-000 024-34305-000
5B 2 Over Load (OL) 9 025-34488-000 025-34488-000 024-31816-000 024-33182-000 024-33182-000 024-33181-000
5C 2 Surge Supressor 9 031-02101-000 031-02101-000 031-02101-000 031-02104-000 031-02104-000 031-02104-0005E 2 Ground Lug 9 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-0006A 2 Contactor 9 024-34309-000 024-34309-000 024-34307-000 024-34306-000 024-34306-000 024-34305-000
6B 2 Over Load (OL) 9 025-34488-000 025-34488-000 024-31816-000 024-33182-000 024-33182-000 024-33181-000
6C 2 Surge Supressor 9 031-02101-000 031-02101-000 031-02101-000 031-02104-000 031-02102-000 031-02104-000
6E 2 Ground Lug 9 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
7A 2 Contactor 9 024-34309-000 024-34309-000 024-34307-000 024-34306-000 024-34306-000 024-34305-000
7B 2 Over Load (OL) 9 025-34488-000 025-34488-000 024-31816-000 024-33182-000 024-33182-000 024-33181-000
7C 2 Surge Supressor 9 031-02101-000 031-02101-000 031-02101-000 031-02104-000 031-02104-000 031-02104-000
7E 2 Ground Lug 9 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
8A 6 Surge Supressor 9 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02104-000
8B 6 Contactor 9 024-34302-000 024-34302-000 024-34302-000 024-34302-000 024-34302-000 024-34302-000
8C 3 Fuseblock 9A 025-34185-000 025-34185-000 025-34185-000 025-34185-000 025-34185-000 025-34185-000
8D 9 Fuse, 600V 9A 025-34142-000 025-34142-000 025-38396-000 025-37618-000 025-38396-000 025-37613-000
11A 2 Relay, Control 9 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
11B 2 Aux Contact Block 9 025-35694-000 025-35694-000 025-35694-000 025-35694-000 025-35694-000 025-35694-000
11C See Below
13A 2 Fuse, 600V 9A 025-34435-000 025-34435-000 025-34431-000 025-37653-000 025-35902-000 025-37611-000
13B 1 Fuseblock 9A 025-34427-000 025-34427-000 025-34427-000 025-35667-000 025-34427-000 025-34427-000
13D 1 Transformer 9 025-38393-000 025-38391-000 025-38392-000 025-38392-000 025-38391-000 025-35652-000
13E 1 Fuseblock 9A 025-35667-000 025-35667-000 025-35667-000 025-35667-000 025-35667-000 025-35667-000
13F 1 Fuse, 12 Amp 9A 025-38360-000 025-38360-000 025-38360-000 025-38360-000 025-38360-000 025-38360-000
13G 1 Fuse, 5 Amp 9A 025-35689-000 025-35689-000 025-35689-000 025-35689-000 025-35689-000 025-35689-000
14 1 Smart Relay 9 025-36414-002 025-36414-002 025-36414-002 025-36414-002 025-36414-002 025-36414-002
15 2 Relay Expansion 9 025-36403-000 025-36403-000 025-36403-000 025-36403-000 025-36403-000 025-36403-000
- 4 Aux. Contact Block - 024-34320-000 024-34320-000 024-34320-000 024-34320-000 024-34320-000 024-34320-000
- 1 Terminal Board - 025-36416-000 025-36416-000 025-36416-000 025-36416-000 025-36416-000 025-36416-000
25 1 Thermostat 9, 9A 025-36346-001 025-36346-001 025-36346-001 025-36346-001 025-36346-001 025-36346-001
MOD A MANEUROP COMPRESSORS
11C 3 Relay, Control 9 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
MOD B COPELAND COMPRESSORS
11C3 Relay, Control 9 024-31635-000 024-31635-000 024-31635-000 024-31635-000 024-31635-000 024-31635-000
3 Relay, Control 9 024-33177-000 024-33177-000 024-33177-000 024-33177-000 024-33177-000 024-33177-000
3 Surge Supressor 9 031-02107-000 031-02107-000 031-02107-000 031-02107-000 031-02107-000 031-02107-000
POWER PANELS 50-95 TON (CONT'D)
YORK INTERNATIONAL4
FORM 160.69-M1 (LS01)
YORK INTERNATIONAL 5
FORM 160.69-M1 (LS01)
90 - 95 TON UNIT CONTROL PANEL AND POWER PANEL (100.50-RP1 PAGE 26)
Item Qty Description SeeFigure 208V 230V 380V 400V-50 460V 575V
5A 2 Contactor 9 024-34310-000 024-34310-000 024-34308-000 024-34307-000 024-34307-000 024-34306-000
5B 2 Over Load (OL) 9 025-34488-000 025-34488-000 024-31816-000 024-31816-000 024-31816-000 024-33182-000
5C 2 Surge Supressor 9 031-02101-000 031-02101-000 031-02101-000 031-02101-000 031-02101-000 031-02104-000
5E 2 Ground Lug 9 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
6A 2 Contactor 9 024-34310-000 024-34310-000 024-34308-000 024-34307-000 024-34307-000 024-34306-000
6B 2 Over Load (OL) 9 025-34488-000 025-34488-000 024-31816-000 024-31816-000 024-31816-000 024-33182-000
6C 2 Surge Supressor 9 031-02101-000 031-02101-000 031-02101-000 031-02101-000 031-02101-000 031-02104-000
6E 2 Ground Lug 9 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
7A 2 Contactor 9 024-34309-000 024-34309-000 024-34307-000 024-34306-000 024-34306-000 024-34305-000
7B 2 Over Load (OL) 9 025-34488-000 025-34488-000 024-31816-000 024-33182-000 024-33182-000 024-33181-000
7C 2 Surge Supressor 9 031-02101-000 031-02101-000 031-02101-000 031-02104-000 031-02104-000 031-02104-000
7E 2 Ground Lug 9 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000 025-34455-000
8A 6 Surge Supressor 9 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02104-000 031-02104-000
8B 6 Contactor 9 024-34302-000 024-34302-000 024-34302-000 024-34302-000 024-34302-000 024-34302-000
8C 3 Fuseblock 9A 025-34185-000 025-34185-000 025-34185-000 025-34185-000 025-34185-000 025-34185-000
8D 9 Fuse, 600V 9A 025-34142-000 025-34142-000 025-38396-000 025-37618-000 025-38396-000 025-37613-000
11A 2 Relay, Control 9 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
11B 2 Aux Contact Block 9 025-35694-000 025-35694-000 025-35694-000 025-35694-000 025-35694-000 025-35694-000
11C See Below
13A 2 Fuse, 600V 9A 025-34435-000 025-34435-000 025-34431-000 025-37653-000 025-35902-000 025-37611-000
13B 1 Fuseblock 9A 025-34427-000 025-34427-000 025-34427-000 025-35667-000 025-34427-000 025-34427-000
13D 1 Transformer 9 025-38393-000 025-38391-000 025-38392-000 025-38392-000 025-38391-000 025-35652-000
13E 1 Fuseblock 9A 025-35667-000 025-35667-000 025-35667-000 025-35667-000 025-35667-000 025-35667-000
13F 1 Fuse, 12 Amp 9A 025-38360-000 025-38360-000 025-38360-000 025-38360-000 025-38360-000 025-38360-000
13G 1 Fuse, 5 Amp 9A 025-35689-000 025-35689-000 025-35689-000 025-35689-000 025-35689-000 025-35689-000
14 1 Smart Relay 9 025-36414-002 025-36414-002 025-36414-002 025-36414-002 025-36414-002 025-36414-002
15 2 Relay Expansion 9 025-36403-000 025-36403-000 025-36403-000 025-36403-000 025-36403-000 025-36403-000
- 4 Aux. Contact Block - 024-34320-000 024-34320-000 024-34320-000 024-34320-000 024-34320-000 024-34320-000
- 1 Terminal Board - 025-36416-000 025-36416-000 025-36416-000 025-36416-000 025-36416-000 025-36416-000
25 1 Thermostat 9, 9A 025-36346-001 025-36346-001 025-36346-001 025-36346-001 025-36346-001 025-36346-001
MOD A MANEUROP COMPRESSORS
11C 3 Relay, Control 9 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000 024-31885-000
MOD B COPELAND COMPRESSORS
11C3 Relay, Control 9 024-31635-000 024-31635-000 024-31635-000 024-31635-000 024-31635-000 024-31635-000
3 Relay, Control 9 024-33177-000 024-33177-000 024-33177-000 024-33177-000 024-33177-000 024-33177-000
3 Surge Supressor 9 031-02107-000 031-02107-000 031-02107-000 031-02107-000 031-02107-000 031-02107-000
POWER PANELS 50-95 TON (CONT'D)
28 YORK INTERNATIONAL
FORM 100.50-RP1 (404)Control and Power Panels
LD09227
FIG. 9 – POWER PANEL
(Location of Stand-Off Sub Panel)
NOTE: All components on this drawing may not be included on all units.
(TB1)
(SW1)
(Optional Convenience
Outlet Kit)
SMART RELAY
RELAY EXPANSION #1
YORK INTERNATIONAL 29
FORM 100.50-RP1 (404)
12
FIG. 9A – STAND-OFF SUB PANEL
LD09228
(TB2)(380V - 575V
Optional Gas Heat Kit)
(380V - 575VOptional
Gas Heat Kit)
(Optional Convenience
Outlet Kit)
(208V & 230V Optional
Gas Heat Kit)
NOTE: All components on this drawing may not be included on all units.
30 YORK INTERNATIONAL
FORM 100.50-RP1 (404)Control and Power Panels
CIRCUIT BREAKER OR DISCONNECT SWITCH ASSEMBLIES
208V UNITS 50-75 TON
ITEM DESCRIPTION QTY SeeFigure
50-65 TON 70-75 TONSingle Point
Terminal Block
Single PointDisc
Multi-PointTerminal
Block
Single PointTerminal
Block
Single PointDisc
Multi-PointTerminal
Block
2A Terminal Block 1 9, 9A 025-37621-000 N/A N/A 025-37621-000 N/A N/A
2A Molded Case Switch(SW1) 1 9, 9A N/A 024-25563-000 N/A N/A 024-25563-000 N/A
3 CB Operator Mech 1 9 N/A 025-35695-000 N/A N/A 025-35695-000 N/A
3 Shaft, 19.69" 9 N/A 025-35696-000 N/A N/A 025-35696-000 N/A
3 Handle, Pistol 1 9 N/A 025-35697-000 N/A N/A 025-35697-000 N/A
2A TB1 1 9, 9A N/A N/A 025-37619-000 N/A N/A 025-37624-000
2A TB2 1 9, 9A N/A N/A 025-37628-000 N/A N/A 025-37628-000
208V UNITS 80-95 TON
ITEM DESCRIPTION QTY SeeFigure
80-85 TON 90-95 TONSingle Point
Terminal Block
Single PointDisc
Multi-PointTerminal
Block
Single PointTerminal
Block
Single PointDisc
Multi-PointTerminal
Block
2A Terminal Block 1 9, 9A 025-37621-000 N/A N/A 025-37621-000 N/A N/A
2A Molded Case Switch (SW1) 1 9, 9A N/A 024-31889-000 N/A N/A 024-31889-000 N/A
3 CB Operator Mech 1 9 N/A 025-35695-000 N/A N/A 025-35695-000 N/A
3 Shaft, 19.69" 9 N/A 025-35696-000 N/A N/A 025-35696-000 N/A
3 Handle, Pistol 1 9 N/A 025-35697-000 N/A N/A 025-35697-000 N/A
2A TB1 1 9, 9A N/A N/A 025-37621-000 N/A N/A 025-37621-000
2A TB2 1 9, 9A N/A N/A 025-37628-000 N/A N/A 025-37623-000
230V UNITS 50-75 TON
ITEM DESCRIPTION QTY SeeFigure
50-65 TON 70-75 TONSingle Point
Terminal Block
Single PointDisc
Multi-PointTerminal
Block
Single PointTerminal
Block
Single PointDisc
Multi-PointTerminal
Block
2A Terminal Block 1 9, 9A 025-37621-000 N/A N/A 025-37621-000 N/A N/A
2A Molded Case Switch (SW1) 1 9, 9A N/A 024-25563-000 N/A N/A 024-25563-000 N/A
3 CB Operator Mech 1 9 N/A 025-35695-000 N/A N/A 025-35695-000 N/A
3 Shaft, 19.69" 9 N/A 025-35696-000 N/A N/A 025-35696-000 N/A
3 Handle, Pistol 1 9 N/A 025-35697-000 N/A N/A 025-35697-000 N/A
2A TB1 1 9, 9A N/A N/A 025-37619-000 N/A N/A 025-37619-000
2A TB2 1 9, 9A N/A N/A 025-37628-000 N/A N/A 025-37628-000
YORK INTERNATIONAL 31
FORM 100.50-RP1 (404)
12
230V UNITS 80-95 TON
ITEM DESCRIPTION QTY SeeFigure
80-95 TONSingle Point
Terminal Block
Single PointDisc
Multi-PointTerminal
Block
2A Terminal Block 1 9, 9A 025-37621-000 N/A N/A
2A Molded Case Switch (SW1) 1 9, 9A N/A 024-25563-000 N/A
3 CB Operator Mech 1 9 N/A 025-35695-000 N/A
3 Shaft, 19.69" 9 N/A 025-35696-000 N/A
3 Handle, Pistol 1 9 N/A 025-35697-000 N/A
2A TB1 1 9, 9A N/A N/A 025-37619-000
2A TB2 1 9, 9A N/A N/A 025-37628-000
380V-60 HZ UNITS 50-85 TON
ITEM DESCRIPTION QTY SeeFigure
50-75 TON 80-85 TONSingle Point
Terminal Block
Single PointDisc
Multi-PointTerminal
Block
Single PointTerminal
Block
Single PointDisc
Multi-PointTerminal
Block
2A Terminal Block 1 9, 9A 025-38394-000 N/A N/A 025-37624-000 N/A N/A
2A Molded Case Switch (SW1) 1 9, 9A N/A 024-25564-000 N/A N/A 024-25564-000 N/A
3 CB Operator Mech 1 9 N/A 025-31878-000 N/A N/A 025-31878-000 N/A
3 Shaft, 19.69" 9 N/A 025-35696-000 N/A N/A 025-35696-000 N/A
3 Handle, Pistol 1 9 N/A 025-35697-000 N/A N/A 025-35697-000 N/A
2A TB1 1 9, 9A N/A N/A 025-37614-000 N/A N/A 025-38394-000
2A TB2 1 9, 9A N/A N/A 025-37615-000 N/A N/A 025-37615-000
380V-60 HZ UNITS 90 TON
ITEM DESCRIPTION QTY SeeFigure
90-95 TONSingle Point
Terminal Block
Single PointDisc
Multi-PointTerminal
Block
2A Terminal Block 1 9, 9A 025-37621-000 N/A N/A
2A Molded Case Switch (SW1) 1 9, 9A N/A 024-25563-000 N/A
3 CB Operator Mech 1 9 N/A 025-35695-000 N/A
3 Shaft, 19.69" 9 N/A 025-35696-000 N/A
3 Handle, Pistol 1 9 N/A 025-35697-000 N/A
2A TB1 1 9, 9A N/A N/A 025-38394-000
2A TB2 1 9, 9A N/A N/A 025-37628-000
CIRCUIT BREAKER OR DISCONNECT SWITCH ASSEMBLIES (CONT'D)
32 YORK INTERNATIONAL
FORM 100.50-RP1 (404)Control and Power Panels
CIRCUIT BREAKER OR DISCONNECT SWITCH ASSEMBLIES (CONT'D)
400V-50 HZ UNITS 50-75 TON
ITEM DESCRIPTION QTY SeeFigure
50-65 TON 70-75 TONSingle Point
Terminal Block
Single PointDisc
Multi-PointTerminal
Block
Single PointTerminal
Block
Single PointDisc
Multi-PointTerminal
Block
2A Terminal Block 1 9, 9A 025-38394-000 N/A N/A 025-37624-000 N/A N/A
2A Molded Case Switch (SW1) 1 9, 9A N/A 024-30963-000 N/A N/A 024-25564-000 N/A
3 CB Operator Mech 1 9 N/A 025-31878-000 N/A N/A 025-31878-000 N/A
3 Shaft, 19.69" 9 N/A 025-35696-000 N/A N/A 025-35696-000 N/A
3 Handle, Pistol 1 9 N/A 025-35697-000 N/A N/A 025-35697-000 N/A
2A TB1 1 9, 9A N/A N/A 025-37614-000 N/A N/A 025-37614-000
2A TB2 1 9, 9A N/A N/A 025-37615-000 N/A N/A 025-37615-000
400V-50 HZ UNITS 80-95 TON
ITEM DESCRIPTION QTY SeeFigure
80-85 TON 90-95 TONSingle Point
Terminal Block
Single PointDisc
Multi-PointTerminal
Block
Single PointTerminal
Block
Single PointDisc
Multi-PointTerminal
Block
2A Terminal Block 1 9, 9A 025-37624-000 N/A N/A 025-38394-000 N/A N/A
2A Molded Case Switch (SW1) 1 9, 9A N/A 024-30963-000 N/A N/A 024-25564-000 N/A
3 CB Operator Mech 1 9 N/A 025-31878-000 N/A N/A 025-31878-000 N/A
3 Shaft, 19.69" 9 N/A 025-35696-000 N/A N/A 025-35696-000 N/A
3 Handle, Pistol 1 9 N/A 025-35697-000 N/A N/A 025-35697-000 N/A
2A TB1 1 9, 9A N/A N/A 025-37614-000 N/A N/A 025-38394-000
2A TB2 1 9, 9A N/A N/A 025-37615-000 N/A N/A 025-37628-000
460V UNITS 50-75 TON
ITEM DESCRIPTION QTY SeeFigure
50-65 TON 70-75 TONSingle Point
Terminal Block
Single PointDisc
Multi-PointTerminal
Block
Single PointTerminal
Block
Single PointDisc
Multi-PointTerminal
Block
2A Terminal Block 1 9, 9A 025-38394-000 N/A N/A 025-37621-000 N/A N/A
2A Molded Case Switch (SW1) 1 9, 9A N/A 024-30963-000 N/A N/A 024-25564-000 N/A
3 CB Operator Mech 1 9 N/A 025-31878-000 N/A N/A 025-31878-000 N/A
3 Shaft, 19.69" 9 N/A 025-35696-000 N/A N/A 025-35696-000 N/A
3 Handle, Pistol 1 9 N/A 025-35697-000 N/A N/A 025-35697-000 N/A
2A TB1 1 9, 9A N/A N/A 025-37614-000 N/A N/A 025-37614-000
2A TB2 1 9, 9A N/A N/A 025-37615-000 N/A N/A 025-37615-000
YORK INTERNATIONAL 33
FORM 100.50-RP1 (404)
12
460V UNITS 80-95 TON
ITEM DESCRIPTION QTY SeeFigure
80-85 TON 90-95 TONSingle Point
Terminal Block
Single PointDisc
Multi-PointTerminal
Block
Single PointTerminal
Block
Single PointDisc
Multi-PointTerminal
Block
2A Terminal Block 1 9, 9A 025-37624-000 N/A N/A 025-37624-000 N/A N/A
2A Molded Case Switch (SW1) 1 9, 9A N/A 024-25564-000 N/A N/A 024-25564-000 N/A
3 CB Operator Mech 1 9 N/A 025-31878-000 N/A N/A 025-31878-000 N/A
3 Shaft, 19.69" 9 N/A 025-35696-000 N/A N/A 025-35696-000 N/A
3 Handle, Pistol 1 9 N/A 025-35697-000 N/A N/A 025-35697-000 N/A
2A TB1 1 9, 9A N/A N/A 025-37614-000 N/A N/A 025-38394-000
2A TB2 1 9, 9A N/A N/A 025-37615-000 N/A N/A 025-37615-000
575V UNITS 50-95 TON
ITEM DESCRIPTION QTY SeeFigure
50-65 TON 70-95TONSingle Point
Terminal Block
Single PointDisc
Multi-PointTerminal
Block
Single PointTerminal
Block
Single PointDisc
Multi-PointTerminal
Block
2A Terminal Block 1 9, 9A 025-38394-000 N/A N/A 025-37624-000 N/A N/A
2A Molded Case Switch (SW1) 1 9, 9A N/A 024-30963-000 N/A N/A 024-25564-000 N/A
3 CB Operator Mech 1 9 N/A 025-31878-000 N/A N/A 025-31878-000 N/A
3 Shaft, 19.69" 9 N/A 025-35696-000 N/A N/A 025-35696-000 N/A
3 Handle, Pistol 1 9 N/A 025-35697-000 N/A N/A 025-35697-000 N/A
2A TB1 1 9, 9A N/A N/A 025-37614-000 N/A N/A 025-37619-000
2A TB2 1 9, 9A N/A N/A 025-37615-000 N/A N/A 025-37628-000
CIRCUIT BREAKER OR DISCONNECT SWITCH ASSEMBLIES (CONT'D)
34 YORK INTERNATIONAL
FORM 100.50-RP1 (404)Control and Power Panels
MICRO-PANEL
MICRO-PANEL PARTS
ITEM DESCRIPTION FIG. NO. QTY PART NO.
A CONTROL, SECONDARY 10 1 025-36105-000
2A TRANSFORMER, CL-2, 1T 10 1 025-35684-000
2B FASTON CONNECTOR 10 1 025-34461-000
3 TRANSFORMER, 2T 10 1 025-27911-000
9 AUGAT/RDI SNAP T 10 0.3 029-23421-000
18 GROUND BAR 10 2 025-35685-000
21 MOD-DCU (No Communication or LON Communication) 10 1 025-36103-012
21 MOD-DCU BACNET IP (Refer to Service Bulletin SB037 for Ordering Information) 10 1 025-36103-010
21 MOD-DCU BACNET MS/TP (Refer to Service Bulletin SB037 for Ordering Information) 10 1 025-36103-011
22 TST-INTERFACE BOARD 10 1 025-36102-000
23 CONN. DOUBLE 10 1 025-10253-000
24 BACNET MSTP CARD (RS485) 10 1 025-37506-000
24 LON CARD 10 1 025-36114-000
25 BACNET IP CARD (ETHERNET) 10 1 025-36239-000
26 CABLE, MOD DCU board to keypad 10 1 071-03655-000
36 YORK INTERNATIONAL
FORM 100.50-RP1 (404)Unique Panel Kits
SECTION 3 - UNIQUE PANEL KITSGAS HEAT KIT
208V UNITS
ITEM DESCRIPTION FIG. NO. QTY PART NO.1A FUSEBLOCK, 2P, 30A 9, 9A 1 025-34427-000
1B FUSE 600V CL-CC 9, 9A 2 025-34435-000
230V UNITS
ITEM DESCRIPTION FIG. NO. QTY PART NO.1A FUSEBLOCK, 2P, 30A 9, 9A 1 025-34427-000
1B FUSE 600V CL-CC 9, 9A 2 025-34430-000
380V - 400V UNITS
ITEM DESCRIPTION FIG. NO. QTY PART NO.1A FUSEBLOCK, 2P, 30A 9, 9A 1 025-34427-000
1B FUSE 600V CL-CC 9, 9A 2 025-34435-000
2A FUSEBLOCK, 2P, 30A 9, 9A 1 025-35667-000
2B FUSE, 250V, 10A 9, 9A 2 025-28966-006
3A 2KVA 1POLE 50/60HZ 11 1 025-34493-000
3B ADPT FLX STR 1/2" 11 1 025-31310-000
3C COND ADPTFLX 1/2" 11 1 025-30473-000
3D ADAPTFLX 1/2" 11 1 025-31316-000
460V UNITS
ITEM DESCRIPTION FIG. NO. QTY PART NO.1A FUSEBLOCK, 2P, 30A 9, 9A 1 025-34427-000
1B FUSE 600V CL-CC 9, 9A 2 025-34430-000
2A FUSEBLOCK, 2P, 30A 9, 9A 1 025-35667-000
2B FUSE, 250V, 10A 9, 9A 2 025-28966-006
3A TRANSFORMER 11 1 025-37605-000
3B ADPT FLX STR 1/2" 11 1 025-31310-000
3C COND ADPTFLX 1/2" 11 1 025-30473-000
3D ADAPTFLX 1/2" 11 1 025-31316-000
575V UNITS
ITEM DESCRIPTION FIG. NO. QTY PART NO.1A FUSEBLOCK, 2P, 30A 9, 9A 1 025-34427-000
1B FUSE 600V CL-CC 9, 9A 2 025-34431-000
2A FUSEBLOCK, 2P, 30A 9, 9A 1 025-35667-000
2B FUSE, 250V, 10A 9, 9A 2 025-28966-006
3A TRANSFORMER 11 1 025-37633-000
3B ADPT FLX STR 1/2" 11 1 025-31310-000
3C COND ADPTFLX 1/2" 11 1 025-30473-000
3D ADAPTFLX 1/2" 11 1 025-31316-000
YORK INTERNATIONAL 37
FORM 100.50-RP1 (404)
LD09244
FIG. 11 – GAS HEAT KIT
Optional Gas Heat Kit
Optional Convenience Outlet Kit
NOTE: All components on this drawing may not be included on every unit.
38 YORK INTERNATIONAL
FORM 100.50-RP1 (404)Unique Panel Kits
CONVENIENCE OUTLET KIT
CONVENIENCE OUTLET KIT UNIQUE PARTS
ITEM DESCRIPTION QTY FIG. NO. 208VUNITS
230VUNiTS
460VUNITS
575VUNITS
1B FUSE 600V CL-CC 2 9, 9A 025-34433-000 025-34428-000 025-34430-000 025-34431-000
3A TRANSFORMER 1 11 025-34493-000 025-37605-000 025-37605-000 025-37633-000
LD09245
FIG. 12 – CONVENIENCE OUTLET KIT
CONVENIENCE OUTLET KIT COMMON PARTS
ITEM DESCRIPTION FIG. NO. QTY PART NO.
1A FUSEBLOCK, 2P, 30A 9, 9A 1 025-34427-000
2A FUSEBLOCK, 1P, 30A 9, 9A 1 025-37601-000
2B FUSE 9, 9A 1 025-37603-000
3B ADPT FLX STR 1/2" 11 1 025-31310-000
3C COND ADPTFLX 1/2" 11 1 025-30473-000
3D ADAPTFLX 1/2" 11 1 025-31316-000
5A GFI 20AMP DUPLX 12 1 025-32500-000
5B COVER, OUTLET 12 1 025-32501-000
Panel Front View
Panel Bottom View
NOTE: All components on this drawing may not be included on every unit.
40 YORK INTERNATIONAL
FORM 100.50-RP1 (404)Unique Panel Kits
LANGUAGE KIT
LANGUAGE KIT
ITEM DESCRIPTION FIG. NO. QTY PART NO.
2 SWITCH, RUN / STOP 14 1 024-25517-000
4 KEYPAD / DISPLAY 14 1 025-36104-000
RDU KIT/LANGUAGE DISPLAY-ENGLISH 325-36222-001
LD09248
FIG. 14 – LANGUAGE KIT
YORK INTERNATIONAL 41
FORM 100.50-RP1 (404)
13
VFD FAN KEYPAD PANEL
VFD FAN KEYPAD PANEL PARTS
ITEM DESCRIPTION FIG. NO. QTY PART NO.
9A VFD FAN KEYPAD PANEL 15 1 071-04285-000
9B LABEL, EXHAUST FAN 15 1 035-17027-000
9C LABEL, SUPPLY FAN 15 1 035-17025-000
10 VFD FAN KEYPAD 15 2 025-36267-000
LD09249
FIG. 15 – VFD FAN KEYPAD PANEL
10 10
42 YORK INTERNATIONAL
FORM 100.50-RP1 (404)Unique Panel Kits
ELECTRIC HEAT POWER SUPPLY BOX KITTERMINAL BLOCK BOXES
(SEE FIGURE 17)Ite
mQ
tyD
escr
iptio
n
50 T
on
60 T
on
50-8
0 To
n 50
-60
Ton
90 T
on50
-70
Ton
80-9
0 To
n
Mul
ti-Po
int
Term
inal
Blo
ck40
KW
Mul
ti-Po
int
Term
inal
Blo
ck40
KW
Mul
ti-Po
int
Term
inal
Blo
ck80
-108
KW
Sing
le-P
oint
Term
inal
Blo
ck40
KW
Mul
ti-Po
int
Term
inal
Blo
ck10
8 K
W
Sing
le-P
oint
Term
inal
Blo
ck80
-108
KW
Sing
le-P
oint
Term
inal
Blo
ck80
-108
KW
2A3
TER
MIN
AL
BLK
, 250
A02
5-34
408-
000
N/A
N/A
N/A
N/A
N/A
N/A
2A3
TER
MIN
AL
BLK
, 400
AN
/A02
5-34
405-
000
025-
3440
5-00
0N
/AN
/AN
/AN
/A
2A6
TER
MIN
AL
BLK
, 600
AN
/AN
/AN
/A02
5-34
408-
000
025-
3440
8-00
002
5-34
408-
000
N/A
2A6
TER
MIN
AL
BLK
, 800
AN
/AN
/AN
/AN
/AN
/AN
/A02
5-34
405-
000
3A1
GR
OU
ND
LU
G02
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
N/A
N/A
N/A
N/A
3A2
GR
OU
ND
LU
GN
/AN
/AN
/A02
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
025-
3408
5-00
0
5A3
FUS
EB
LK, 1
P, 2
00A
RA
MR
AM
025-
3252
1-00
0R
AM
025-
3252
1-00
002
5-32
521-
000
025-
3252
1-00
0
5D1
GR
OU
ND
LU
G02
5-34
088-
000
025-
3408
8-00
002
5-34
089-
000
025-
3408
8-00
002
5-34
089-
000
025-
3408
9-00
002
5-34
089-
000
81
GR
OU
ND
LU
G02
5-34
089-
000
025-
3408
6-00
002
5-34
086-
000
N/A
N/A
N/A
N/A
82
GR
OU
ND
LU
GN
/AN
/AN
/A02
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
025-
3408
6-00
0
208V
UN
ITS
Item
Qty
Des
crip
tion
50 T
on
50 T
on
60 T
on
50 T
on
50-9
0 To
n60
Ton
60-9
0 To
n
Mul
ti-Po
int
Term
inal
Blo
ck40
KW
Sing
le-P
oint
Term
inal
Blo
ck40
KW
Mul
ti-Po
int
Term
inal
Blo
ck40
KW
Sing
le-P
oint
Term
inal
Blo
ck80
-108
KW
Mul
ti-Po
int
Term
inal
Blo
ck80
-108
KW
Sing
le-P
oint
Term
inal
Blo
ck40
KW
Sing
le-P
oint
Term
inal
Blo
ck80
-108
KW
2A3
TER
MIN
AL
BLK
, 250
A02
5-34
408-
000
N/A
N/A
N/A
N/A
N/A
N/A
2A3
TER
MIN
AL
BLK
, 400
AN
/A02
5-34
405-
000
025-
3440
5-00
002
5-34
405-
000
025-
3440
5-00
0N
/AN
/A
2A6
TER
MIN
AL
BLK
, 600
AN
/AN
/AN
/AN
/AN
/A02
5-34
408-
000
025-
3440
8-00
0
2A6
TER
MIN
AL
BLK
, 800
AN
/AN
/AN
/AN
/AN
/AN
/AN
/A
3A1
GR
OU
ND
LU
G02
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
N/A
N/A
3A2
GR
OU
ND
LU
GN
/AN
/AN
/AN
/AN
/A02
5-34
085-
000
025-
3408
5-00
0
5A3
FUS
EB
LK, 1
P, 2
00A
RA
MR
AM
RA
M02
5-32
521-
000
025-
3252
1-00
0R
AM
025-
3252
1-00
0
5D1
GR
OU
ND
LU
G02
5-34
088-
000
025-
3408
8-00
002
5-34
088-
000
025-
3408
9-00
002
5-34
089-
000
025-
3408
8-00
002
5-34
089-
000
81
GR
OU
ND
LU
G02
5-34
089-
000
025-
3408
6-00
002
5-34
086-
000
025-
3408
6-00
002
5-34
086-
000
N/A
N/A
82
GR
OU
ND
LU
GN
/AN
/AN
/AN
/AN
/A02
5-34
085-
000
025-
3408
5-00
0
230V
UN
ITS F
use
info
rmat
ion
can
be l
ocat
ed i
n Ta
ble
3 on
pag
e 55
.
YORK INTERNATIONAL 43
FORM 100.50-RP1 (404)
13
ELECTRIC HEAT POWER SUPPLY BOX KITTERMINAL BLOCK BOXES (CONT'D)
Item
Qty
Des
crip
tion
50 T
on50
-60
Ton
50 T
on
50-9
0 To
n 60
Ton
60
Ton
50-9
0 To
n50
-90
Ton
70-9
0 To
n
Sing
le-P
oint
Term
inal
B
lock
40 K
W
See
Fig
16
Mul
ti-Po
int
Term
inal
B
lock
40 K
W
See
Fig
16
Sing
le-P
oint
Term
inal
B
lock
80-1
08 K
W
See
Fig
17
Mul
ti-Po
int
Term
inal
B
lock
80-1
08 K
W
See
Fig
17
Sing
le-P
oint
Term
inal
B
lock
40 K
W
See
Fig
17
Sing
le-P
oint
Term
inal
B
lock
80-1
08 K
W
See
Fig
17
Sing
le-P
oint
Term
inal
B
lock
150-
200
KW
Se
e Fi
g 17
Mul
ti-Po
int
Term
inal
B
lock
150-
200
KW
Se
e Fi
g 17
Sing
le-P
oint
Term
inal
B
lock
80-1
08 K
W
See
Fig
17
2A3
TER
MIN
AL
BLK
, 250
A02
5-34
408-
000
025-
3440
8-00
002
5-34
408-
000
025-
3440
8-00
0N
/AN
/AN
/AN
/AN
/A
2A3
TER
MIN
AL
BLK
, 400
AN
/AN
/AN
/AN
/A02
5-34
405-
000
025-
3440
5-00
002
5-34
405-
000
025-
3440
5-00
0N
/A
2A6
TER
MIN
AL
BLK
, 800
AN
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/A02
5-34
405-
000
3A1
GR
OU
ND
LU
G02
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
025-
3408
5-00
0N
/A
3A2
GR
OU
ND
LU
GN
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/A02
5-34
085-
000
5A3
FUS
EB
LOC
K, 1
P, 2
00A
N/A
N/A
RA
MR
AM
N/A
RA
M02
5-32
521-
000
025-
3252
1-00
0R
AM
5A1
FUS
EB
LOC
K, 3
P, 1
00A
RA
MR
AM
N/A
N/A
RA
MN
/AN
/AN
/AN
/A
5D1
GR
OU
ND
LU
G02
5-34
455-
000
025-
3445
5-00
002
5-34
088-
000
025-
3408
8-00
002
5-34
455-
000
025-
3408
8-00
002
5-34
089-
000
025-
3408
9-00
002
5-34
088-
000
81
GR
OU
ND
LU
G02
5-34
089-
000
025-
3408
9-00
002
5-34
089-
000
025-
3408
9-00
002
5-34
085-
000
025-
3408
6-00
002
5-34
086-
000
025-
3408
6-00
0N
/A
82
GR
OU
ND
LU
GN
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/A02
5-34
086-
000
380V
-60
HZ
UN
ITS
Item
Qty
Des
crip
tion
50-6
0 To
n50
-60
Ton
50-6
0 To
n 50
-90
Ton
50-9
0 To
n50
-90
Ton
70-9
0 To
n
Sing
le-P
oint
Term
inal
B
lock
40 K
W
See
Fig
16
Mul
ti-Po
int
Term
inal
B
lock
40 K
W
See
Fig
16
Sing
le-P
oint
Term
inal
B
lock
80-1
08 K
W
See
Fig
17
Mul
ti-Po
int
Term
inal
B
lock
80-1
08 K
W
See
Fig
17
Sing
le-P
oint
Term
inal
B
lock
150-
200
KW
Se
e Fi
g 17
Mul
ti-Po
int
Term
inal
B
lock
150-
200
KW
Se
e Fi
g 17
Sing
le-P
oint
Term
inal
B
lock
80-1
08 K
W
See
Fig
17
2A3
TER
MIN
AL
BLK
, 250
A02
5-34
408-
000
025-
3440
8-00
002
5-34
408-
000
025-
3440
8-00
0N
/AN
/AN
/A
2A3
TER
MIN
AL
BLK
, 400
AN
/AN
/AN
/AN
/A02
5-34
405-
000
025-
3440
5-00
0N
/A
2A6
TER
MIN
AL
BLK
, 800
AN
/AN
/AN
/AN
/AN
/AN
/A02
5-34
405-
000
3A1
GR
OU
ND
LU
G02
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
025-
3408
5-00
0N
/A
3A2
GR
OU
ND
LU
GN
/AN
/AN
/AN
/AN
/AN
/A02
5-34
085-
000
5A3
FUS
EB
LOC
K, 1
P, 2
00A
N/A
N/A
RA
MR
AM
025-
3252
1-00
002
5-32
521-
000
RA
M
5A1
FUS
EB
LOC
K, 3
P, 1
00A
RA
MR
AM
N/A
N/A
N/A
N/A
N/A
5D1
GR
OU
ND
LU
G02
5-34
455-
000
025-
3445
5-00
002
5-34
088-
000
025-
3408
8-00
002
5-34
089-
000
025-
3408
9-00
002
5-34
088-
000
81
GR
OU
ND
LU
G02
5-34
089-
000
025-
3408
9-00
002
5-34
089-
000
025-
3408
9-00
002
5-34
086-
000
025-
3408
6-00
0N
/A
82
GR
OU
ND
LU
GN
/AN
/AN
/AN
/AN
/AN
/A02
5-34
086-
000
400V
-50
HZ
UN
ITS
Fuse information can be located in Table 3 on page 55.
44 YORK INTERNATIONAL
FORM 100.50-RP1 (404)Unique Panel Kits
Item
Qty
Des
crip
tion
50-6
0 To
n50
-60
Ton
50-6
0 To
n 50
-90
Ton
50-6
0 To
n 70
-90
Ton
70-9
0 To
n70
-90
Ton
Sing
le-P
oint
Term
inal
B
lock
40 K
W
See
Fig
16
Mul
ti-Po
int
Term
inal
B
lock
40 K
W
See
Fig
16
Sing
le-P
oint
Term
inal
B
lock
80-1
08 K
W
See
Fig
17
Mul
ti-Po
int
Term
inal
B
lock
80-1
50 K
W
See
Fig
17
Sing
le-P
oint
Term
inal
B
lock
150
KW
See
Fig
17
Mul
ti-Po
int
Term
inal
B
lock
200-
250
KW
See
Fig
17
Sing
le-P
oint
Term
inal
B
lock
200-
250
KW
See
Fig
17
Sing
le-P
oint
Term
inal
B
lock
80-1
50 K
W
See
Fig
17
2A3
TER
MIN
AL
BLK
, 250
A02
5-34
408-
000
025-
3440
8-00
002
5-34
408-
000
025-
3440
8-00
0N
/AN
/AN
/AN
/A
2A3
TER
MIN
AL
BLK
, 400
AN
/AN
/AN
/AN
/A02
5-34
405-
000
025-
3440
5-00
0N
/AN
/A
2A6
TER
MIN
AL
BLK
, 600
AN
/AN
/AN
/AN
/AN
/AN
/A02
5-34
408-
000
N/A
2A6
TER
MIN
AL
BLK
, 800
AN
/AN
/AN
/AN
/AN
/AN
/AN
/A02
5-34
405-
000
3A1
GR
OU
ND
LU
G02
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
025-
3408
5-00
0N
/AN
/A
3A2
GR
OU
ND
LU
GN
/AN
/AN
/AN
/AN
/AN
/A02
5-34
085-
000
025-
3408
5-00
0
5A1
FUS
EB
LOC
K, 3
P, 6
0AR
AM
N/A
N/A
N/A
N/A
N/A
N/A
N/A
5A3
FUS
EB
LOC
K, 1
P, 2
00A
N/A
N/A
RA
MR
AM
N/A
025-
3252
1-00
002
5-32
521-
000
RA
M
5A1
FUS
EB
LOC
K, 3
P, 1
00A
N/A
RA
MN
/AN
/AR
AM
N/A
N/A
N/A
5D1
GR
OU
ND
LU
G02
5-34
455-
000
025-
3445
5-00
002
5-34
088-
000
025-
3408
8-00
002
5-34
088-
000
025-
3408
9-00
002
5-34
089-
000
025-
3408
8-00
0
81
GR
OU
ND
LU
G02
5-34
089-
000
025-
3408
9-00
002
5-34
089-
000
025-
3408
9-00
002
5-34
086-
000
025-
3408
6-00
0N
/AN
/A
82
GR
OU
ND
LU
GN
/AN
/AN
/AN
/AN
/AN
/A02
5-34
085-
000
025-
3408
6-00
0
460V
UN
ITS
Item
Qty
Des
crip
tion
50-6
0 To
n50
-60
Ton
50-8
0 To
n 50
-80
Ton
50-6
0 To
n 50
-90
Ton
50-9
0 To
n 70
-90
Ton
70-9
0 To
n90
Ton
Sing
le-P
oint
Term
inal
B
lock
40 K
W
See
Fig
16
Mul
ti-Po
int
Term
inal
B
lock
40 K
W
See
Fig
16
Sing
le-P
oint
Term
inal
B
lock
80 K
W
See
Fig
16
Mul
ti-Po
int
Term
inal
B
lock
80 K
W
See
Fig
16
Sing
le-P
oint
Term
inal
B
lock
80-1
08 K
W
See
Fig
17
Mul
ti-Po
int
Term
inal
B
lock
80-1
50 K
W
See
Fig
17
Sing
le-P
oint
Term
inal
B
lock
108-
150
KW
See
Fig
17
Sing
le-P
oint
Term
inal
B
lock
200
KW
See
Fig
17
Mul
ti-Po
int
Term
inal
B
lock
200-
250
KW
See
Fig
17
Sing
le-P
oint
Term
inal
B
lock
250
KW
See
Fig
17
2A3
TER
MIN
AL
BLK
, 250
A02
5-34
408-
000
025-
3440
8-00
002
5-34
408-
000
025-
3440
8-00
002
5-34
408-
000
025-
3440
8-00
0N
/AN
/AN
/AN
/A
2A3
TER
MIN
AL
BLK
, 400
AN
/AN
/AN
/AN
/AN
/AN
/A02
5-34
405-
000
025-
3440
5-00
002
5-34
405-
000
N/A
2A6
TER
MIN
AL
BLK
, 600
AN
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/A02
5-34
408-
000
3A1
GR
OU
ND
LU
G02
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
N/A
3A2
GR
OU
ND
LU
GN
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/A02
5-34
085-
000
5A1
FUS
EB
LOC
K, 3
P, 6
0AR
AM
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
5A3
FUS
EB
LOC
K, 1
P, 2
00A
N/A
N/A
N/A
N/A
RA
MR
AM
N/A
025-
3252
1-00
002
5-32
521-
000
025-
3252
1-00
0
5A1
FUS
EB
LOC
K, 3
P, 1
00A
N/A
RA
MR
AM
RA
MN
/AN
/AR
AM
N/A
N/A
N/A
5D1
GR
OU
ND
LU
G02
5-34
455-
000
025-
3445
5-00
002
5-34
455-
000
025-
3445
5-00
002
5-34
088-
000
025-
3408
8-00
002
5-34
088-
000
025-
3408
9-00
002
5-34
089-
000
025-
3408
9-00
0
81
GR
OU
ND
LU
G02
5-34
089-
000
025-
3408
9-00
002
5-34
089-
000
025-
3408
9-00
002
5-34
089-
000
025-
3408
9-00
002
5-34
086-
000
025-
3408
6-00
002
5-34
086-
000
N/A
82
GR
OU
ND
LU
GN
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/AN
/A02
5-34
085-
000
575V
UN
ITS
Fuse information can be located in Table 3 on page 55.
ELECTRIC HEAT POWER SUPPLY BOX KITTERMINAL BLOCK BOXES (CONT'D)
YORK INTERNATIONAL 47
FORM 100.50-RP1 (404)
13
ELECTRIC HEAT POWER SUPPLY BOX KITDISCONNECT SWITCH BOXES
(SEE FIGURE 18)
Item Qty Description
50-65 Ton 50-75 Ton 80-95 Ton
Single-PointDisc Sw40 KW
Single-PointDisc Sw
80-108 KW
Single-PointDisc Sw
80-108 KW
2A 1 MOLDED CASE SWITCH, 600A 024-25563-000 024-25563-000 N/A
2A 1 MOLDED CASE SWITCH, 800A N/A N/A 024-31889-000
1 OPERATOR MECH 025-35695-000 025-35695-000 025-35695-000
1 SHAFT, 19.69" 025-35696-000 025-35696-000 025-35696-000
1 HANDLE, PISTOL 025-35697-000 025-35697-000 025-35697-000
3A 1 GROUND LUG 025-34089-000 N/A N/A
3A 2 GROUND LUG N/A 025-34089-000 025-34085-000
5A 3 FUSEBLK, 1P, 200A RAM 025-32521-000 025-32521-000
5D 1 GROUND LUG 025-34088-000 025-34089-000 025-34089-000
8 2 GROUND LUG 025-34085-000 025-34085-000 025-34086-000
208V UNITS
230V UNITS
Item Qty Description
50-65 Ton 50-85 Ton 90-95 Ton
Single-PointDisc Sw40 KW
Single-PointDisc Sw
80-108 KW
Single-PointDisc Sw
80-108 KW
2A 1 MOLDED CASE SWITCH, 600A 024-25563-000 024-25563-000 N/A
2A 1 MOLDED CASE SWITCH, 800A N/A N/A 024-31889-000
1 OPERATOR MECH 025-35695-000 025-35695-000 025-35695-000
1 SHAFT, 19.69" 025-35696-000 025-35696-000 025-35696-000
1 HANDLE, PISTOL 025-35697-000 025-35697-000 025-35697-000
3A 1 GROUND LUG 025-34089-000 N/A N/A
3A 2 GROUND LUG N/A 025-34089-000 025-34085-000
5A 3 FUSEBLK, 1P, 200A RAM 025-32521-000 025-32521-000
5D 1 GROUND LUG 025-34088-000 025-34089-000 025-34089-000
8 2 GROUND LUG 025-34085-000 025-34085-000 025-34086-000
Fuse information can be located in Table 3 on page 55.
YORK INTERNATIONAL6
FORM 160.69-M1 (LS01)
YORK INTERNATIONAL 7
FORM 160.69-M1 (LS01)
ELECTRIC HEAT POWER SUPPLY BOX KITDISCONNECT SWITCH BOXES (100.50-RP1 PAGE 48)
Item
Qty
Des
crip
tion
50 T
on
50 T
on
60 T
on
60 T
on
50-9
0 To
n70
-90T
on
Sing
le-P
oint
Dis
c Sw
40 K
W
See
Fig
19
Sing
le-P
oint
Dis
c Sw
80-1
08 K
W
See
Fig
19
Sing
le-P
oint
Dis
c Sw
40 K
W
See
Fig
18
Sing
le-P
oint
Dis
c Sw
80-1
08 K
W
See
Fig
19
Sing
le-P
oint
Dis
c Sw
150-
200
KW
See
Fig
18
Sing
le-P
oint
Dis
c Sw
80-1
08 K
WS
ee F
ig 1
8
2A1
MO
LDE
D C
AS
E S
WIT
CH
, 250
A02
4-30
963-
000
N/A
N/A
N/A
N/A
N/A
2A1
MO
LDE
D C
AS
E S
WIT
CH
, 400
AN
/A02
4-25
564-
000
024-
2556
4-00
002
4-25
564-
000
024-
2556
4-00
0N
/A
2A1
MO
LDE
D C
AS
E S
WIT
CH
, 600
AN
/AN
/AN
/AN
/AN
/A02
4-25
563-
000
1O
PE
RAT
OR
ME
CH
024-
3187
8-00
002
4-31
878-
000
024-
3187
8-00
002
4-31
878-
000
024-
3187
8-00
002
5-35
695-
000
1S
HA
FT, 1
9.69
"02
5-35
696-
000
025-
3569
6-00
002
5-35
696-
000
025-
3569
6-00
002
5-35
696-
000
025-
3569
6-00
0
1H
AN
DLE
, PIS
TOL
025-
3569
7-00
002
5-35
697-
000
025-
3569
7-00
002
5-35
697-
000
025-
3569
7-00
002
5-35
697-
000
3A1
GR
OU
ND
LU
G02
5-34
085-
000
025-
3408
5-00
002
5-34
086-
000
025-
3408
6-00
002
5-34
086-
000
N/A
3A2
GR
OU
ND
LU
GN
/AN
/AN
/AN
/AN
/A02
5-34
089-
000
5A3
FUS
EB
LK, 1
P, 2
00A
N/A
RA
MN
/AR
AM
025-
3252
1-00
0R
AM
5A1
FUS
EB
LK, 3
P, 1
00A
RA
MN
/AR
AM
N/A
N/A
N/A
5D1
GR
OU
ND
LU
G02
5-34
455-
000
025-
3408
8-00
002
5-34
455-
000
025-
3408
8-00
002
5-34
089-
000
025-
3408
8-00
0
81
GR
OU
ND
LU
GN
/A02
5-34
089-
000
025-
3408
5-00
0N
/A02
5-34
085-
000
N/A
82
GR
OU
ND
LU
G02
5-34
089-
000
N/A
N/A
025-
3408
9-00
0N
/A02
5-34
085-
000
Item
Qty
Des
crip
tion
50-6
0 To
n 50
-60
Ton
50-9
0 To
n70
-90T
on
Sing
le-P
oint
Dis
c Sw
40 K
W
See
Fig
19
Sing
le-P
oint
Dis
c Sw
80-1
08 K
W
See
Fig
18
Sing
le-P
oint
Dis
c Sw
150-
200
KW
See
Fig
18
Sing
le-P
oint
Dis
c Sw
80-1
08 K
WS
ee F
ig 1
8
2A1
MO
LDE
D C
AS
E S
WIT
CH
, 250
A02
4-30
963-
000
N/A
N/A
N/A
2A1
MO
LDE
D C
AS
E S
WIT
CH
, 400
AN
/A02
4-25
564-
000
024-
2556
4-00
0N
/A
2A1
MO
LDE
D C
AS
E S
WIT
CH
, 600
AN
/AN
/AN
/A02
4-25
563-
000
1O
PE
RAT
OR
ME
CH
024-
3187
8-00
002
4-31
878-
000
024-
3187
8-00
002
5-35
695-
000
1S
HA
FT, 1
9.69
"02
5-35
696-
000
025-
3569
6-00
002
5-35
696-
000
025-
3569
6-00
0
1H
AN
DLE
, PIS
TOL
025-
3569
7-00
002
5-35
697-
000
025-
3569
7-00
002
5-35
697-
000
3A1
GR
OU
ND
LU
G02
5-34
085-
000
025-
3408
5-00
002
5-34
086-
000
N/A
3A2
GR
OU
ND
LU
GN
/AN
/AN
/A02
5-34
089-
000
5A3
FUS
EB
LK, 1
P, 2
00A
N/A
RA
M02
5-32
521-
000
RA
M
5A1
FUS
EB
LK, 3
P, 1
00A
RA
MN
/AN
/AN
/A
5D1
GR
OU
ND
LU
G02
5-34
455-
000
025-
3408
8-00
002
5-34
089-
000
025-
3408
8-00
0
81
GR
OU
ND
LU
GN
/A02
5-34
089-
000
025-
3408
5-00
0N
/A8
2G
RO
UN
D L
UG
025-
3408
9-00
0N
/AN
/A02
5-34
085-
000
400V
-50V
UN
ITS
Fuse information can be located in Table 3 on page 55.
380V
-60V
UN
ITS
YORK INTERNATIONAL6
FORM 160.69-M1 (LS01)
YORK INTERNATIONAL 7
FORM 160.69-M1 (LS01)
ELECTRIC HEAT POWER SUPPLY BOX KITDISCONNECT SWITCH BOXES (100.50-RP1 PAGE 49)
Item
Qty
Des
crip
tion
50-6
0 To
n 50
-60
Ton
50-6
0 To
n 70
-90
Ton
70-9
0 To
n
Sing
le-P
oint
Dis
c Sw
40 K
W
Sing
le-P
oint
Dis
c Sw
80-1
08 K
W
See
Fig
18
Sing
le-P
oint
Dis
c Sw
150
KW
S
ee F
ig 1
8
Sing
le-P
oint
Dis
c Sw
80-1
50 K
W
See
Fig
18
Sing
le-P
oint
Dis
c Sw
200-
250
KW
See
Fig
18
See
Fig
19
2A1
MO
LDE
D C
AS
E S
WIT
CH
, 250
A02
4-30
963-
000
N/A
N/A
N/A
N/A
2A1
MO
LDE
D C
AS
E S
WIT
CH
, 400
AN
/A02
4-30
963-
000
024-
2556
4-00
0N
/AN
/A
2A1
MO
LDE
D C
AS
E S
WIT
CH
, 600
AN
/AN
/AN
/A02
4-25
563-
000
024-
2556
3-00
0
1O
PE
RAT
OR
ME
CH
024-
3187
8-00
002
4-31
878-
000
024-
3187
8-00
002
5-35
695-
000
025-
3569
5-00
0
1S
HA
FT, 1
9.69
"02
5-35
696-
000
025-
3569
6-00
002
5-35
696-
000
025-
3569
6-00
002
5-35
696-
000
1H
AN
DLE
, PIS
TOL
025-
3569
7-00
002
5-35
697-
000
025-
3569
7-00
002
5-35
697-
000
025-
3569
7-00
0
3A1
GR
OU
ND
LU
G02
5-34
085-
000
025-
3408
5-00
002
5-34
086-
000
025-
3408
9-00
002
5-34
089-
000
5A1
FUS
EB
LK, 3
P, 6
0AR
AM
N/A
N/A
N/A
N/A
5A3
FUS
EB
LK, 1
P, 2
00A
N/A
RA
MR
AM
RA
M02
5-32
521-
000
5D1
GR
OU
ND
LU
G02
5-34
455-
000
025-
3408
8-00
002
5-34
088-
000
025-
3408
8-00
002
5-34
089-
000
82
GR
OU
ND
LU
G02
5-34
089-
000
025-
3408
9-00
002
5-34
089-
000
025-
3408
5-00
002
5-34
085-
000
460V
UN
ITS
Item
Qty
Des
crip
tion
50-6
0 To
n 50
-80
Ton
50-6
0 To
n 50
-80
Ton
70-9
0 To
n90
Ton
90 T
on
Sing
le-P
oint
Dis
c Sw
40 K
W
See
Fig
19
Sing
le-P
oint
Dis
c Sw
80 K
W
See
Fig
19
Sing
le-P
oint
Dis
c Sw
108
KW
S
ee F
ig 1
8
Sing
le-P
oint
Dis
c Sw
108-
150
KW
S
ee F
ig 1
8
Sing
le-P
oint
Dis
c Sw
200
KW
See
Fig
18
Sing
le-P
oint
Dis
c Sw
108-
150
KW
See
Fig
18
Sing
le-P
oint
Dis
c Sw
250
KW
See
Fig
18
2A1
MO
LDE
D C
AS
E S
WIT
CH
, 250
A02
4-30
963-
000
N/A
N/A
N/A
N/A
N/A
N/A
2A1
MO
LDE
D C
AS
E S
WIT
CH
, 400
AN
/A02
4-30
963-
000
024-
3096
3-00
002
4-25
564-
000
024-
3556
3-00
0N
/AN
/A
2A1
MO
LDE
D C
AS
E S
WIT
CH
, 600
AN
/AN
/AN
/AN
/AN
/A02
4-25
563-
000
024-
2556
3-00
0
1O
PE
RAT
OR
ME
CH
024-
3187
8-00
002
4-31
878-
000
024-
3187
8-00
002
4-31
878-
000
025-
3569
5-00
002
5-35
695-
000
025-
3569
5-00
0
1S
HA
FT, 1
9.69
"02
5-35
696-
000
025-
3569
6-00
002
5-35
696-
000
025-
3569
6-00
002
5-35
696-
000
025-
3569
6-00
002
5-35
696-
000
1H
AN
DLE
, PIS
TOL
025-
3569
7-00
002
5-35
697-
000
025-
3569
7-00
002
5-35
697-
000
025-
3569
7-00
002
5-35
697-
000
025-
3569
7-00
0
3A1
GR
OU
ND
LU
G02
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
025-
3408
6-00
002
5-34
089-
000
025-
3408
9-00
002
5-34
089-
000
5A1
FUS
EB
LK, 3
P, 6
0AR
AM
N/A
N/A
N/A
N/A
N/A
N/A
5A3
FUS
EB
LK, 1
P, 2
00A
N/A
N/A
RA
MR
AM
RA
MR
AM
025-
3252
1-00
0
5A1
FUS
EB
LK, 3
P, 1
00A
N/A
RA
MN
/AN
/AN
/AN
/A
5D1
GR
OU
ND
LU
G02
5-34
455-
000
025-
3445
5-00
002
5-34
088-
000
025-
3408
8-00
002
5-34
088-
000
025-
3408
8-00
002
5-34
089-
000
81
GR
OU
ND
LU
GN
/A02
5-34
089-
000
025-
3408
9-00
0N
/AN
/AN
/A
82
GR
OU
ND
LU
G02
5-34
089-
000
N/A
N/A
025-
3408
9-00
002
5-34
085-
000
025-
3408
5-00
002
5-34
085-
000
575V
UN
ITS
Fuse information can be located in Table 3 on page 55.
52 YORK INTERNATIONAL
FORM 100.50-RP1 (404)C
IRC
UIT
CO
NN
ECTO
RPO
SITI
ON
S &
WIR
E N
UM
BER
SH
OU
SIN
GC
ON
TAC
TN
OTE
S1
23
45
67
89
1011
12A
MP
TYP
EY
OR
K P
AR
T #
AM
P TY
PE
YO
RK
PA
RT
#
1LLS
V, 2
LLS
V,
3LLS
VJ3
9 (P
AN
EL)
152
GN
D25
2G
ND
352
GN
DC
AP
1-4
8070
7-0
025-
2119
1-00
0P
IN 3
5068
7-1
025-
2221
4-00
02
P39
(RTU
)P
LUG
1-4
8070
6-0
025-
2119
2-00
0S
KT
3505
36-1
025-
2221
5-00
0
HG
SV
J40
(PA
NE
L)16
2C
AP
1-4
8069
9-0
025-
2115
9-00
0P
IN 3
5068
7-1
025-
2221
4-00
0
P40
(RTU
)P
LUG
1-4
8069
8-0
025-
1967
2-00
0S
KT
3505
36-1
025-
2221
5-00
0
SF
DP
-SW
J25
(PA
NE
L)B
I11
BIR
SH
CA
P 1
-480
701-
0R
AM
# C
N-0
641
PIN
350
687-
102
5-22
214-
000
(AIR
FLO
W P
RO
VE
)P
25 (R
TU)
PLU
G 1
-480
700-
002
5-19
671-
000
SK
T 35
0536
-102
5-22
215-
000
FIL
TER
DP
-SW
(C
LOG
GE
D A
LAR
M)
J26
(PA
NE
L)B
I12
BIR
SH
CA
P 1
-480
701-
0R
AM
# C
N-0
641
PIN
350
687-
102
5-22
214-
000
P26
(RTU
)P
LUG
1-4
8070
0-0
025-
1967
1-00
0S
KT
3505
36-1
025-
2221
5-00
0
EVA
P. C
OIL
FR
EE
SE
STA
TJ2
7 (P
AN
EL)
BI1
3B
IRS
HC
AP
1-4
8070
1-0
RA
M #
CN
-064
1P
IN 3
5068
7-1
025-
2221
4-00
0
P27
(RTU
)P
LUG
1-4
8070
0-0
025-
1967
1-00
0S
KT
3505
36-1
025-
2221
5-00
0
HW
CO
IL
FRE
ES
ES
TAT
J28
(PA
NE
L)B
I14
BIR
SH
CA
P 1
-480
701-
0R
AM
# C
N-0
641
PIN
350
687-
102
5-22
214-
000
P28
(RTU
)P
LUG
1-4
8070
0-0
025-
1967
1-00
0S
KT
3505
36-1
025-
2221
5-00
0
TEM
P &
RH
S
EN
SO
RS
J29
(PA
NE
L)S
EE
SH
EE
T “T
EM
P &
PR
ES
S S
EN
SO
RS
”C
AP
1-4
8070
9-0
025-
2078
7-00
0P
IN 3
5068
7-1
025-
2221
4-00
0
P29
(RTU
)P
LUG
1-4
8070
8-0
025-
2119
6-00
0S
KT
3505
36-1
025-
2221
5-00
0
AM
S P
RE
SS
UR
E
#1J3
0, J
31 (P
AN
EL)
SE
E S
HE
ET
“TE
MP
& P
RE
SS
SE
NS
OR
S”
CA
P 1
-480
705-
002
5-20
963-
000
PIN
350
687-
102
5-22
214-
000
P30
, P31
(RTU
)P
LUG
1-4
8070
4-0
025-
1967
0-00
0S
KT
3505
36-1
025-
2221
5-00
0
AM
S P
RE
SS
UR
E
#2J3
2 (P
AN
EL)
SE
E S
HE
ET
“TE
MP
& P
RE
SS
SE
NS
OR
S”
CA
P 1
-480
701-
0R
AM
# C
N-0
641
PIN
350
687-
102
5-22
214-
000
P32
(RTU
)P
LUG
1-4
8070
0-0
025-
1967
1-00
0S
KT
3505
36-1
025-
2221
5-00
0
GA
S F
UR
NA
CE
C
ON
TRO
L PA
NE
LJ3
3 (P
AN
EL)
121
122
CO
M14
312
312
4C
OM
142
125
126
CO
M14
1C
AP
1-4
8070
7-0
025-
2078
7-00
0P
IN 3
5068
7-1
025-
2221
4-00
0
P33
(RTU
)P
LUG
1-4
8070
6-0
025-
2119
6-00
0S
KT
3505
36-1
025-
2221
5-00
0
SA
FETY
CH
AIN
(S
YS
TEM
1)
J22
(PA
NE
L)12
712
7A14
4C
AP
1-4
8070
1-0
RA
M #
CN
-064
1P
IN 3
5068
7-1
025-
2221
4-00
0
P22
(RTU
)P
LUG
1-4
8070
0-0
025-
1967
1-00
0S
KT
3505
36-1
025-
2221
5-00
0
SA
FETY
CH
AIN
(S
YS
TEM
2)
J23
(PA
NE
L)12
812
8A14
5C
AP
1-4
8070
1-0
RA
M #
CN
-064
1P
IN 3
5068
7-1
025-
2221
4-00
0
P23
(RTU
)P
LUG
1-4
8070
0-0
025-
1967
1-00
0S
KT
3505
36-1
025-
2221
5-00
0
SA
FETY
CH
AIN
(S
YS
TEM
3)
J24
(PA
NE
L)12
912
9A14
6C
AP
1-4
8070
1-0
RA
M #
CN
-064
1P
IN 3
5068
7-1
025-
2221
4-00
0
P24
(RTU
)P
LUG
1-4
8070
0-0
025-
1967
1-00
0S
KT
3505
36-1
025-
2221
5-00
0
HW
/STE
AM
-CV
J34
(PA
NE
L)20
02C
OM
AO
6A
O6C
GN
DC
AP
1-4
8070
5-0
025-
2096
3-00
0P
IN 3
5068
7-1
025-
2221
4-00
0
P34
(RTU
)P
LUG
1-4
8070
4-0
025-
1967
0-00
0S
KT
3505
36-1
025-
2221
5-00
0
AIR
MIX
ING
D
AM
PE
RS
J35
(PA
NE
L)20
02C
OM
AO
5A
O5C
AO
4A
O4C
GN
DC
AP
1-4
8070
7-0
025-
2119
1-00
0P
IN 3
5068
7-1
025-
2221
4-00
0
P35
(RTU
)P
LUG
1-4
8070
6-0
025-
2119
2-00
0S
KT
3505
36-1
025-
2221
5-00
0
EA
& O
A/R
A D
AM
PE
RS
J36
(PA
NE
L)20
02C
OM
AO
2A
O2C
AO
3A
O3C
GN
DC
AP
1-4
8070
7-0
025-
2119
1-00
0P
IN 3
5068
7-1
025-
2221
4-00
02
P36
(RTU
)P
LUG
1-4
8070
6-0
025-
2119
2-00
0S
KT
3505
36-1
025-
2221
5-00
0
SF-
VFD
J38
(PA
NE
L)A
O1
AO
1CS
FWS
CM
GN
DC
AP
1-4
8070
5-0
025-
2096
3-00
0P
IN 3
5068
7-1
025-
2221
4-00
0
P38
(RTU
)P
LUG
1-4
8070
4-0
025-
1967
0-00
0S
KT
3505
36-1
025-
2221
5-00
0
EF-
VFD
J37
(PA
NE
L)A
O2
AO
2CE
FWE
CM
GN
DC
AP
1-4
8070
5-0
025-
2096
3-00
0P
IN 3
5068
7-1
025-
2221
4-00
0
P37
(RTU
)P
LUG
1-4
8070
4-0
025-
1967
0-00
0S
KT
3505
36-1
025-
2221
5-00
0
SF-
VFD
BY
PAS
S
PAN
EL
J47
(PA
NE
L)10
8C
OM
VFD
BY
PC
AP
1-4
8070
3-0
025-
2175
6-00
0P
IN 3
5068
7-1
025-
2221
4-00
0
P47
(SF-
VFD
)R
RC
OM
VFD
BY
PP
LUG
1-4
8070
2-0
025-
2141
7-00
0S
KT
3505
36-1
025-
2221
5-00
02
NO
TES:
1. P
AN
EL
HA
RN
ES
S S
HA
LL H
AVE
CA
P/P
IN C
ON
NE
CTO
RS
SU
ITA
BLE
FO
R B
ULK
HE
AD
MO
UN
TIN
G.
RTU
HA
RN
ES
S W
ILL
HAV
E M
ATIN
G P
LUG
/SO
CK
ET
CO
NN
NE
CTO
RS
.
2. F
OR
DU
AL
WIR
E T
ER
MIN
ATIO
N, U
SE
AM
P P
IN #
350
700-
1 (Y
K-0
25-2
0919
-000
).
MICRO HARNESS CONNECTORS
YORK INTERNATIONAL 53
FORM 100.50-RP1 (404)
SUPPLY FAN MOTOR FUSES
Unit Size Motor HP Voltage Hertz Amps Part Number
50-65 10
200 60 40 025-36173-000230 60 40 025-36173-000460 60 20 025-36168-000575 60 15 025-36167-000400 50 25 025-36169-000380 60 25 025-36169-000
50-95
15
200 60 60 025-36176-000230 60 60 025-36176-000460 60 25 025-36169-000575 60 20 025-36168-000400 50 30 025-36170-000380 60 30 025-36170-000
20
200 60 80 025-36178-000230 60 80 025-36178-000460 60 30 025-36170-000575 60 30 025-36170-000400 50 40 025-36173-000380 60 40 025-36173-000
25
200 60 90 025-36179-000230 60 90 025-36179-000460 60 40 025-36173-000575 60 40 025-36173-000400 50 50 025-36175-000380 60 50 025-36175-000
30
200 60 125 025-36282-000230 60 100 025-36180-000460 60 50 025-36175-000575 60 40 025-36173-000400 50 60 025-36176-000380 60 60 025-36176-000
40
200 60 150 025-36182-000230 60 125 025-36282-000460 60 60 025-36176-000575 60 50 025-36175-000400 50 80 025-36178-000380 60 80 025-36178-000
70-95
50
200 60 175 025-36183-000230 60 150 025-36182-000460 60 80 025-36178-000575 60 60 025-36176-000400 50 90 025-36179-000380 60 90 025-36179-000
60
200 60 200 025-36184-000230 60 175 025-36183-000460 60 90 025-36179-000575 60 80 025-36178-000400 50 125 025-36282-000380 60 125 025-36282-000
TABLE 1 - SUPPLY FAN FUSES
54 YORK INTERNATIONAL
FORM 100.50-RP1 (404)
EXHAUST FAN MOTOR VFD FUSES
TABLE 2 - EXHAUST FAN MOTOR VFD FUSES
Unit Size Motor HP Voltage Hertz Amps Part Number
50-95
5
200 60 20 025-36168-000
230 60 20 025-36168-000
460 60 10 025-36281-000
575 60 10 025-36281-000
400 50 10 025-36281-000
380 60 10 025-36281-000
7.5
200 60 30 025-36170-000
230 60 30 025-36170-000
460 60 15 025-36167-000
575 60 15 025-36167-000
400 50 20 025-36168-000
380 60 20 025-36168-000
10
200 60 40 025-36173-000
230 60 40 025-36173-000
460 60 20 025-36168-000
575 60 15 025-36167-000
400 50 25 025-36169-000
380 60 25 025-36169-000
15
200 60 60 025-36176-000
230 60 60 025-36176-000
460 60 25 025-36169-000
575 60 20 025-36168-000
400 50 30 025-36170-000
380 60 30 025-36170-000
20
200 60 80 025-36178-000
230 60 80 025-36178-000
460 60 30 025-36170-000
575 60 30 025-36170-000
400 50 40 025-36173-000
380 60 40 025-36173-000
70-95
25
200 60 90 025-36179-000
230 60 90 025-36179-000
460 60 40 025-36173-000
575 60 40 025-36173-000
400 50 50 025-36175-000
380 60 50 025-36175-000
30
200 60 100 025-36180-000
230 60 100 025-36180-000
460 60 50 025-36175-000
575 60 40 025-36173-000
400 50 60 025-36176-000
380 60 60 025-36176-000
YORK INTERNATIONAL 55
FORM 100.50-RP1 (404)
ELECTRIC HEATER COIL FUSES
TABLE 3 - ELECTRIC HEATER COIL FUSES
Amps Part Number50 025-36307-001
60 025-36307-002
70 025-36307-003
90 025-36307-004
125 025-36307-005
150 025-36307-006
175 025-32821-000
200 025-32822-000
225 025-32523-000
250 025-32524-000
300 025-32525-000
350 025-32526-000