Top Banner
04-04-2012 COMPARATIVE ANALYSIS BETWEEN SUPERMARKET FREEZER WITH REMOTE COMPRESSOR AND PLUGIN FREEZERS WITH BUILT IN COMPRESSOR Nelson de Jesus – Technical Department
8

04-04-2012 COMPARATIVE ANALYSIS BETWEEN SUPERMARKET FREEZER WITH REMOTE COMPRESSOR AND PLUGIN FREEZERS WITH BUILT IN COMPRESSOR Nelson de Jesus – Technical.

Mar 30, 2015

Download

Documents

Maci Crowe
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 04-04-2012 COMPARATIVE ANALYSIS BETWEEN SUPERMARKET FREEZER WITH REMOTE COMPRESSOR AND PLUGIN FREEZERS WITH BUILT IN COMPRESSOR Nelson de Jesus – Technical.

04-04-2012

COMPARATIVE ANALYSIS BETWEEN SUPERMARKET FREEZER WITH REMOTE COMPRESSOR AND PLUGIN FREEZERS WITH BUILT

IN COMPRESSOR

Nelson de Jesus – Technical Department

Page 2: 04-04-2012 COMPARATIVE ANALYSIS BETWEEN SUPERMARKET FREEZER WITH REMOTE COMPRESSOR AND PLUGIN FREEZERS WITH BUILT IN COMPRESSOR Nelson de Jesus – Technical.

Layout With Plug-in Cabinets

Nelson de Jesus – Technical Department

Fricon Equipments to use:• 12x SMR 2200SL

• Net Volume: 584dm3• Ocupied Area: 1,914 m2• Consumption in 24h:

• AD model: 11,6KWh/24h• Variable Speed: 6,2KWh/24H

• 4x SMR 1700SL• Net Volume: 450dm3• Ocupied Area: 1,479 m2• Consumption in 24h:

• AD model: 9,2KWh/24h• Variable Speed: 5,1KWh/24H

• 4x SMR 1900SL• Net Volume: 480dm3• Ocupied Area: 1,653 m2• Consumption in 24h:

• AD model: 8,3KWh/24h• Variable Speed: 5,1KWh/24H

04-04-2012

Page 3: 04-04-2012 COMPARATIVE ANALYSIS BETWEEN SUPERMARKET FREEZER WITH REMOTE COMPRESSOR AND PLUGIN FREEZERS WITH BUILT IN COMPRESSOR Nelson de Jesus – Technical.

Nelson de Jesus – Technical Department

 

Totals for the 2 Plug- in Islands

   

 

04-04-2012

Page 4: 04-04-2012 COMPARATIVE ANALYSIS BETWEEN SUPERMARKET FREEZER WITH REMOTE COMPRESSOR AND PLUGIN FREEZERS WITH BUILT IN COMPRESSOR Nelson de Jesus – Technical.

Layout With Remote Compressor Islands

Nelson de Jesus – Technical Department

Equipments with Remote Compressor:• 4x Cosmo 3 LG300:2500

• Net Volume: 1610dm3• Ocupied Area: 5,04 m2• Consumption in 24h:15,51KWh/24h

• 2x Cosmo 3 LG300:1880• Net Volume: 1214dm3• Ocupied Area: 3,79 m2• Consumption in 24h:10,62KWh/24h

• 4x Cosmo 3 TG300• Net Volume: 640dm3• Ocupied Area: 2,16 m2• Consumption in 24h:10,62KWh/24h

The consumption indicated are only for the peripherals of the cabinets: fans, defrost resistances, glass resistances

04-04-2012

Page 5: 04-04-2012 COMPARATIVE ANALYSIS BETWEEN SUPERMARKET FREEZER WITH REMOTE COMPRESSOR AND PLUGIN FREEZERS WITH BUILT IN COMPRESSOR Nelson de Jesus – Technical.

Nelson de Jesus – Technical Department

 

Totals for the 2 Remote Compressor Islands

 

 

04-04-2012

Page 6: 04-04-2012 COMPARATIVE ANALYSIS BETWEEN SUPERMARKET FREEZER WITH REMOTE COMPRESSOR AND PLUGIN FREEZERS WITH BUILT IN COMPRESSOR Nelson de Jesus – Technical.

Nelson de Jesus – Technical Department

Totals for the 2 Remote Compressor Islands

 

 

 

Cabinet Peripherals:• Evaporator Ventilator - 80W;• Drain Resistance – 289W;• Evaporator Resistance – 1980W;• Recory Resistance – 1050W;• Tray Resistance – 78W;• Glass Resistance – 80W.

Compressor :• Brand– Bitzer;• Reference – 4NC 12.2Y;• Gás – R404a;• Cooling Capacity @-35ºC – 8920W• Power Consumption – 14.1KW;• Peak Current – 69A

04-04-2012

Page 7: 04-04-2012 COMPARATIVE ANALYSIS BETWEEN SUPERMARKET FREEZER WITH REMOTE COMPRESSOR AND PLUGIN FREEZERS WITH BUILT IN COMPRESSOR Nelson de Jesus – Technical.

Nelson de Jesus – Technical Department

Comparisson in Consumption per Liter

SMR AD SMR ADVS Remote Compressor

Total Volume (dm3)10728 10728 11428

Occupied Area (m2)35,50 35,50 36,40

Consumption (KWh/24h)209,20 115,20 294,91

Consumption per Liter (W/l)19,50 10,74 25,8

Consumption per Liter Comparison

04-04-2012

Page 8: 04-04-2012 COMPARATIVE ANALYSIS BETWEEN SUPERMARKET FREEZER WITH REMOTE COMPRESSOR AND PLUGIN FREEZERS WITH BUILT IN COMPRESSOR Nelson de Jesus – Technical.

Year Consumption Comparison

Consumption Comparison between Remote Compressor and Plug-in Island

Remote Compressor SMR AD SMR  AD VS

Consumption Kw 24/h 294,91 KWh/24H 209,2Kw/h 115,2Kw/h

JAN (31) 91.422,10 64.852,00 35.712,00 KW/h per monthFEB (28) 82.574,80 58.576,00 32.256,00 KW/h per monthMAR (31) 91.422,10 64.852,00 35.712,00 KW/h per monthAPR (30) 88.473,00 62.760,00 34.560,00 KW/h per monthMAY (31) 91.422,10 64.852,00 35.712,00 KW/h per monthJUN (30) 88.473,00 62.760,00 34.560,00 KW/h per monthJUL (31) 91.422,10 64.852,00 35.712,00 KW/h per monthAGO (31) 91.422,10 64.852,00 35.712,00 KW/h per monthSEP (30) 88.473,00 62.760,00 34.560,00 KW/h per monthOCT (31) 91.422,10 64.852,00 35.712,00 KW/h per monthNOV (30) 88.473,00 62.760,00 34.560,00 KW/h per monthDEC (31) 91.422,10 64.852,00 35.712,00 KW/h per month

Total 1.076.421,50 763.580,00 420.480,00 KW/h per Year

Savings Benchmark 29% 61%

Nelson de Jesus – Technical Department 04-04-2012