Part of Thermo Fisher Scientific Thermo Scientific Revco ® Laboratory Refrigerators and Freezers Unrivalled cold storage protection for valuable samples and materials Chromatography General Purpose Blood Bank Plasma Pharmacy Enzyme Refrigerated Incubation
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Part of Thermo Fisher Scientific
Thermo Scientific Revco® LaboratoryRefrigerators and Freezers
Unrivalled cold storageprotection for valuablesamples and materials
Thermo Scientific Revco LaboratoryRefrigerators and Freezers
Unrivalled sampleprotection
Researchers worldwide protect more than twobillion samples inside Thermo Scientific cold storageequipment. With proven solutions including +4°Crefrigerators to -196°C cryogenic freezers and Nalgene®
and NuncTM consumables, you're free to concentrateon your work without worrying about your valuablesamples.
Chromatography page page page6 8 10General Purpose Blood Bank
501662_Thermo 8/3/07 12:06 AM Page 2
Reliable, dependable performance
• The IntrLogic™ microprocessorcontroller, available on all +4°C refrigerators and -20°Cor -30°C lab freezers, controls,measures, compares, andreports cabinet operation withdigital accuracy
• All our refrigerator and freezercabinets, including space-savingundercounter and upright models,share design and technologyimprovements developed throughdecades of experience
IntrLogic control panel is standard on Revco refrigerators and freezers (except BOD models).
ModularControl DesignSelf-contained controlhousing integrated intomain control panel forefficient maintenance,as required
Setpoint SecurityKey-operated triple position switchfor main power and alarm; locks intemperature and alarm setpoints tominimize setpoint error and preventtampering
IntrLogic GuideOffers information at-a-glance for all
control and display functionsMicroprocessor-Based ControlIntrLogic microprocessor managessetpoint and actual conditions to providethe highest level of security for thestored product
Instrument-Grade ComponentsElectronic components and sub-systems are selectedfor performance and reliability under demandinglaboratory conditions
Service ParametersTouchpad sequence allows override access to controlfunction defaults for troubleshooting functions
Power Down ModeDuring power failure digital display
dims to conserve backup battery
Thermo Scientific Revco lab refrigerators and freezers include enhanceddigital electronic technology designed to simplify operation and delivergreater accuracy.• Icon-based controls and displays include graphic references for universal operation
• Setpoint security with key-operated triple-position master switch controls power to allsystems for added safety
• A graphic thermometer confirms proper operation at-a-glance, shows normal, high or lowtemperature condition; steady green for normal, flashing top bar for overtemperature,flashing bulb for undertemperature
• Auto defrost models feature an advanced defrost sensor which manages the defrost cycle,minimizing trace amounts of frost build-up to maintain refrigeration coil efficiency
Overtemperature continuous* slow flash, icon only yes
Undertemperature continuous* slow flash, icon only yes
Power Loss continuous* slow flash, icon only yes
Door Ajar delay no
Low Battery no no
Service Required no no
Audible and visual warnings for door ajar, low alarm battery, system maintenance and power failure provide immediate status of critical functions. A push-button alarm testverifies sensor continuity, while the battery backup assures system readiness. The enlarged digital display improves visibility, taking the guesswork out of setpoint andperformance management.
*Mute will silence audible alarm with 6-minute ring back interval; display remains flashing. Moving triple position key switch to middle position disables alarm and audibleand visual warnings.
501662_Thermo 8/3/07 12:06 AM Page 4
5
GraphicThermometerEasy to view,shows normal, highor low temperaturecondition; steadygreen for normal,flashing top bar forovertemperature,flashing bulb forundertemperature
Digital DisplayIndicates cabinettemperature duringnormal operation,flashes during alarmcondition or setpointadjustment. Displaysother values withtouchpad sequence
Audible AlarmAudible and visual indicators areactivated in the event of warm,cold or power loss conditions.Mute will silence audible alarmwith 6 minute ring back interval;display remains flashing
Interior Light SwitchEnables interior lightingsystem (on applicablemodels)
Power Failure IconIlluminated when mainpower is interrupted
Service RequiredIlluminated when
controller is inprogramming mode,
or if simulated warmor cold conditions fail
to occur duringalarm test function
Door AjarIlluminated whendoor is left openand alarm is in“active” mode(not available on45.8 cu.ft. (1297 L)sliding glass doormodels)
Battery BackupContinuous chargeprovides full alarmfunction in case ofpower failure
Low Battery AlarmIlluminated when thealarm system batterybackup charge is low
Touchpad Scan Changes main display;also used to access various programming andservice functions (alarm mute, recall 6 minutes)
Alarm Test Pressing “up” and “scan” buttonscreates simulated overtemperature andundertemperature condition and activatesaudible and visual alarms; display flashesmomentarily when test is complete
Laboratory QualityCabinet ConstructionOur refrigerators and freezers areavailable in 10 sizes, from compact4.9 cu.ft. (133 L) undercountermodels to spacious, triple-door78.8 cu.ft. (2231 L) cabinets. Allmodels are built to meet UL, CUL,CE and TUV standards for safety.
• Hermetically sealed refrigerationcompressor, air-cooled condenserand automatic condensateremoval for auto defrost models
• An efficient, high-capacity aircirculation system optimizestop-to-bottom temperatureuniformity, acceleratestemperature recoveryfollowing door openings, andaccommodates insertion ofwarm product
• Depending on model selection,standard or optional shelves,drawers, temperature recorders,cabinet casters and otheraccessories are available to meetmost laboratory needs
Laboratory Refrigerator and FreezerSelection Guide
Our chromatographyrefrigerators feature the IntrLogicmicroprocessor control system,positive airflow systems, industrialquality cabinet construction andextra-strength refrigerationcompressors selected for industrial,clinical and scientific use.
IntrLogic Microprocessor Control
Our REC series refrigeratorsfeature enhanced digital electronictechnology designed to simplifyoperation and deliver greateraccuracy (see pages 4 and 5).
• Adjustable temperature control,range +1°C to +8°C, factorypre-set to +4°C
• Icon-based controls and displaysinclude graphic references foruniversal operation
• Setpoint security with key-operated triple-position masterswitch controls power toall systems for added safety
• Audible/visual warnings for over-temperature, undertemperatureand power failure, with visualstatus reports on critical functions
• Graphic thermometer confirms
proper operation at-a-glance,shows normal, high or lowtemperature condition; steadygreen for normal, flashing top barfor overtemperature, flashing bulbfor undertemperature
• Advanced defrost sensormanages the defrost cycle,minimizing trace amounts of frostbuild-up to maintain refrigerationcoil efficiency
• Enlarged digital display,resolution to within 0.1°C,improves visibility
• Push-button alarm test verifiessensor continuity
• Battery backup assures controlpanel function during powerfailure
• Remote alarm contacts areincluded on all models
Our chromatographyrefrigerators are designedfor a variety of applicationsrequiring close temperaturecontrol, full access tochromatographyinstrumentation and easyset-up of instrumentationand apparatus within thechamber.
6
REC-7504 chromatography refrigerator. Casters and glass doors arestandard. Shown with optional temperature recorder.
501662_Thermo 8/3/07 12:06 AM Page 6
Cabinet Constructionand Performance• All refrigeration and control
systems are top-mounted(except sliding glass door modelREC-4504, base mounted)
• Door lock provision on all models
• One duplex vapor-proof interioroutlet, continuous on; separatepower cord provided
• Door-activated light switchon all models except REC-4504
• Model REC-4504 hasindependent switch activatedlights only
• Epoxy-coated, open wire shelves,adjustable in 1" (25 mm)increments; no tools required
• Multi-pane glass door(s) withspring loaded door closures anda 90° stay-open feature (exceptsliding door model REC-4504)
• Positive, forced-air circulationmaintains temperature uniformityat all shelf levels
Optional Accessories• Voltage safeguard, free standing
• Temperature recorder, 6" (152mm) circular chart, 7-day drive
• Additional access port,2" (50 mm) diameter, with cover
• Stainless steel interior andexterior surfaces
• Additional shelves, full or half size
• Heated glass doors and doorswing variations available onmost models
7
ORDERING INFORMATION
Temperature Range: +1°C to +8°C, factory preset to +4°C (auto defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ Full Half H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Door Shelves Shelves inches (mm) inches (mm) lb (kg)
REC-2304A 23.3 115 (60) 9.4/15 (P1) single, glass 0 2 58.0 x 29.0 x 24.0 79.1 x 36.2 x 28.0 425 (193)REC-2304D (659) 208/230 (60) 6.0/15 (P4) (1470 x 730 x 610) (2010 x 920 x 720)REC-2304V 230 (50) 6.0/15 (P7)
REC-3004A 29.2 115 (60) 9.4/15 (P1) single, glass 0 2 58.0 x 29.0 x 30.0 79.1 x 36.2 x 34.0 435 (197)REC-3004D (82.6) 208/230 (60) 6.0/15 (P4) (1470 x 730 x 760) (2010 x 920 x 870)REC-3004V 230 (50) 6.0/15 (P7)
REC-4504A 45.8 115 (60) 15.0/20 (P2) double, sliding, glass 4 2 58.0 x 26.0 x 52.5 79.1 x 33.0 x 56.5 670 (304)REC-4504D (1297) 208/230 (60) 8.5/15 (P4) (1470 x 660 x 1330) (2010 x 840 x 1440)REC-4504V 230 (50) 8.5/15 (P7)
REC-5004A 51.1 115 (60) 15.0/20 (P2) double, glass 4 2 58.0 x 29.0 x 52.5 79.1 x 36.2 x 56.5 580 (263)REC-5004D (1447) 208/230 (60) 8.5/15 (P4) (1470 x 730 x 1330) (2010 x 920 x 1440)REC-5004V 230 (50) 8.5/15 (P7)
REC-7504A 78.8 115 (60) 16.0/20 (P2) triple, glass 8 2 58.0 x 29.0 x 81.0 79.1 x 36.2 x 85.0 965 (438)REC-7504D (2231) 208/230 (60) 10.5/15 (P4) (1470 x 730 x 2050) (2010 x 920 x 2160)REC-7504V 230 (50) 10.5/15 (P7)
Chromatography Refrigerators
* Published interior volumes are nominal; useable cu.ft. (L) capacities may be offset by shelves, drawers, blower coils, or cabinet protrusions. For specific cabinet dimensions and allowances, or for verification of clearancetolerances, contact our sales representative. Product performance may be affected by ambient temperature conditions, humidity conditions, sample loading preferences, and frequency of door openings. Contact our salesrepresentative for specific inquiries regarding your application.
REC-4504 chromatography refrigeratorwith sliding glass doors as standard.
Our REL series refrigerators featurethe IntrLogic microprocessor controlsystem, positive airflow systems,industrial quality cabinet constructionand extra-strength refrigerationcompressors selected for industrial,clinical and scientific use.
IntrLogic Microprocessor Control
Our REL series lab refrigeratorsfeature enhanced digital electronictechnology designed to simplifyoperation and deliver greateraccuracy (see pages 4 and 5).
• Adjustable temperature control,range +1°C to +8°C, factorypre-set to +4°C
• Icon-based controls and displaysinclude graphic references foruniversal operation
• Setpoint security with key-operated triple-position masterswitch controls power toall systems for added safety
• Audible/visual warnings for over-temperature, undertemperatureand power failure, with visualstatus reports on critical functions
• Graphic thermometer confirms
proper operation at-a-glance,shows normal, high or lowtemperature condition; steadygreen for normal, flashing top barfor overtemperature, flashing bulbfor undertemperature
• Advanced defrost sensormanages the defrost cycle,minimizing trace amounts of frostbuild-up to maintain refrigerationcoil efficiency
• Enlarged digital display,resolution to within 0.1°C,improves visibility
• Push-button alarm test verifiessensor continuity
• Battery backup assures controlpanel function during powerfailure
• Remote alarm contacts areincluded on all models
Our selection of generalpurpose laboratoryrefrigerators offers cabinetsizes to fit a variety of spaceneeds and storage volumerequirements.
8
Left to right: Models REL-2304, REL-404 and REL-5004. Shown with optional casters and temperaturerecorders. Optional glass doors are available. Model REL-404 shown with optional finished countertop.
• Full-view glass doors, doublepane construction (standardon REL-4504)
• Heated glass doors and doorswing variations are availableon most models
• Finished countertop for REL-404
9
ORDERING INFORMATION
* Published interior volumes are nominal; useable cu.ft. (L) capacities may be offset by shelves, drawers, blower coils, or cabinet protrusions. For specific cabinet dimensions and allowances, or for verification of clearancetolerances, contact our sales representatives. Product performance may be affected by ambient temperature conditions, humidity conditions, sample loading preferences, and frequency of door openings. Contact our salesrepresentatives for specific inquiries regarding your application.
REL-5004 refrigerator shownwith optional casters and
temperature recorder.
Temperature Range: +1°C to +8°C, factory preset to +4°C (auto defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Cabinet Door Shelves inches (mm) inches (mm) lb (kg)
REL-404A 4.9 115 (60) 8.0/15 (P1) undercounter single, 3 20.0 x 20.0 x 20.0 33.4 x 26.0 x 24.0 212 (96)REL-404V (133) 230 (50) 6.0/15 (P7) solid (500 x 500 x 500) (850 x 660 x 610)
REL-1204A 11.5 115 (60) 9.4/15 (P1) space single, 4 52.0 x 21.0 x 20.0 71.9 x 28.8 x 24.0 280 (127)REL-1204V (326) 230 (50) 6.0/15 (P7) saver solid (1320 x 530 x 500) (1830 x 740 x 610)
REL-2304A 23.3 115 (60) 9.4/15 (P1) upright single, 4 58.0 x 29.0 x 24.0 77.5 x 35.5 x 28.0 405 (184)REL-2304D (659) 208/230 (60) 6.0/15 (P4) solid (1470 x 730 x 610) (1970 x 910 x 720)REL-2304V 230 (50) 6.0/15 (P7)
REL-3004A 29.2 115 (60) 9.4/15 (P1) upright single, 4 58.0 x 29.0 x 30.0 77.5 x 35.5 x 34.0 435 (197)REL-3004D (826) 208/230 (60) 6.0/15 (P4) solid (1470 x 730 x 760) (1970 x 910 x 870)REL-3004V 230 (50) 6.0/15 (P7)
REL-4504A 45.8 115 (60) 15.0/20 (P2) upright double, 8 58.0 x 26.0 x 52.0 77.5 x 35.0 x 56.5 670 (304)REL-4504D (1297) 208/230 (60) 8.5/15 (P4) sliding glass (1470 x 660 x 1320) (1970 x 890 x 1440)REL-4504V 230 (50) 8.5/15 (P7)
REL-5004A 51.1 115 (60) 15.0/20 (P2) upright double, 8 58.0 x 29.0 x 52.0 77.5 x 35.5 x 56.5 585 (265)REL-5004D (1447) 208/230 (60) 8.5/15 (P4) solid (1470 x 730 x 1320) (1970 x 910 x 1440)REL-5004V 230 (50) 8.5/15 (P7)
REL-7504A 78.8 115 (60) 16.0/20 (P2) upright triple, 12 58.0 x 29.0 x 81.0 77.5 x 35.5 x 85.0 805 (365)REL-7504D (2231) 208/230 (60) 10.5/15 (P4) solid (1470 x 730 x 2050) (1970 x 910 x 2160)REL-7504V 230 (50) 10.5/15 (P7)
Our REB series refrigerators featurethe IntrLogic microprocessor controlsystem, positive airflow systems,industrial quality cabinet constructionand extra-strength refrigerationcompressors selected for industrial,clinical and scientific use.
IntrLogic Microprocessor Control
Our REB blood bank refrigeratorsfeature enhanced digital electronictechnology designed to simplifyoperation and deliver greateraccuracy (see pages 4 and 5).
• Adjustable temperature control,range +1°C to +8°C, factorypre-set to +4°C
• Icon-based controls and displaysinclude graphic references foruniversal operation
• Setpoint security with key-operated triple-position masterswitch controls power toall systems for added safety
• Audible/visual warnings for over-temperature, undertemperatureand power failure, with visualstatus reports on critical functions
• Alarm setpoints pre-set to warnof temperature deviation at+5.5°C overtemperature and+1.5°C undertemperature
• Graphic thermometer confirms
proper operation at-a-glance,shows normal, high or lowtemperature condition; steadygreen for normal, flashing top barfor overtemperature, flashing bulbfor undertemperature
• Advanced defrost sensormanages the defrost cycle,minimizing trace amounts of frostbuild-up to maintain refrigerationcoil efficiency
• Enlarged digital display,resolution to within 0.1°C,improves visibility
Our blood bank refrigeratorsare designed to meet strictrequirements established by theAABB, ANRC and FDA forstorage of whole blood andblood components.The complete selection of +4°Crefrigerators feature simplifiedpush-button alarm test functionsand reliable, field-provenrefrigeration systems.
10
Upright blood bank refrigerators featureroll-out drawers and temperature recorders asstandard. Model shown REB-5004.
REB-404 undercounter blood bankrefrigerator shown with optional
• Heated glass doors and doorswing variations available onmost models
• Finished countertop for REB-404
11
ORDERING INFORMATION
* Published interior volumes are nominal; useable cu.ft. (L) capacities may be offset by shelves, drawers, blower coils, or cabinet protrusions. For specific cabinet dimensions and allowances, or for verification of clearancetolerances, contact our sales representative. Product performance may be affected by ambient temperature conditions, humidity conditions, sample loading preferences, and frequency of door openings. Contact our salesrepresentative for specific inquiries regarding your application.
** Nominal capacity based on 450 mL whole blood bags.
Slimline REB-1204 bloodbank refrigerator.
Temperature Range: +1°C to +8°C, factory preset to +4°C (auto defrost)
Cu.Ft./L Int. Dimensions* Ext. Dimensions*(Blood Bag Voltage Amps/ H x D x W H x D x W Ship Weight
Model No. Capacity)** (Hz) Breaker (Plug) Cabinet Door Drawers inches (mm) inches (mm) lb (kg)
REB-404A 4.9/133 115 (60) 8.0/15 (P1) undercounter single, 2 20.0 x 20.0 x 20.0 33.4 x 26.0 x 24.0 212 (96)REB-404V (48) 230 (50) 6.0/15 (P7) solid (500 x 500 x 500) (850 x 660 x 610)
REB-1204A 11.5/326 115 (60) 9.4/15 (P1) space single, 5 52.0 x 21.0 x 20.0 71.9 x 28.8 x 24.0 320 (145)REB-1204V (120) 230 (50) 6.0/15 (P7) saver glass (1320 x 530 x 500) (1830 x 740 x 610)
REB-2304A 23.3/659 115 (60) 9.4/15 (P1) upright single, 6 58.0 x 29.0 x 24.0 77.5 x 35.5 x 28.0 470 (213)REB-2304D (288) 208/230 (60) 6.0/15 (P4) glass (1470 x 730 x 610) (1970 x 910 x 720)REB-2304V 230 (50) 6.0/15 (P7)
REB-3004A 29.2/826 115 (60) 9.4/15 (P1) upright single, 6 58.0 x 29.0 x 30.0 77.5 x 35.5 x 34.0 505 (227)REB-3004D (360) 208/230 (60) 6.0/15 (P4) glass (1470 x 730 x 760) (1970 x 910 x 870)REB-3004V 230 (50) 6.0/15 (P7)
REB-5004A 51.1/1447 115 (60) 15.0/20 (P2) upright double, 12 58.0 x 29.0 x 52.0 77.5 x 35.5 x 56.5 790 (359)REB-5004D (576) 208/230 (60) 8.5/15 (P4) glass (1470 x 730 x 1320) (1970 x 910 x 1440)REB-5004V 230 (50) 8.5/15 (P7)
Our RPR series pharmacyrefrigerators feature the IntrLogicmicroprocessor control system,positive airflow systems, industrialquality cabinet construction andextra-strength refrigerationcompressors selected for industrial,clinical and scientific use.
IntrLogic Microprocessor Control
Our RPR pharmacy refrigeratorsfeature enhanced digital electronictechnology designed to simplifyoperation and deliver greateraccuracy (see pages 4 and 5).
• Adjustable temperature control,range +1°C to +8°C, factorypre-set to +4°C
• Icon-based controls and displaysinclude graphic references foruniversal operation
• Setpoint security with key-operated triple-position masterswitch controls power toall systems for added safety
• Audible/visual warnings for over-temperature, undertemperatureand power failure, with visualstatus reports on critical functions
• Graphic thermometer confirms
proper operation at-a-glance,shows normal, high or lowtemperature condition; steadygreen for normal, flashing top barfor overtemperature, flashing bulbfor undertemperature
• Advanced defrost sensormanages the defrost cycle,minimizing trace amounts of frostbuild-up to maintain refrigerationcoil efficiency
• Enlarged digital display,resolution to within 0.1°C,improves visibility
• Push button alarm test verifiessensor continuity
• Battery backup assures controlpanel function during powerfailure
• Remote alarm contacts areincluded on all models
Configured for accuratestorage and easy retrievalof pharmacy products, our RPRpharmacy refrigerators featurefull extension stainless steelroll-out drawers. Developedfor stable temperaturecontrol over a range of +1°Cto +8°C, these refrigeratorsare available in four sizes.
12
Our pharmacy refrigerators aredesigned to provide stable
temperature control and allowefficient inventory management.
Model shown: RPR-3004 with fullextension roll-out drawers and
full view glass door.
501662_Thermo 8/3/07 12:06 AM Page 12
Cabinet Constructionand Inventory System• Full extension stainless steel
drawers, fully adjustable
• Full view glass door(s), doublepane construction eliminatescondensation; spring-loadedclosures include 90o stay openfeature
• Heated glass doors and doorswing variations available onmost models
13
ORDERING INFORMATION
* Published interior volumes are nominal; useable cu.ft. (L) capacities may be offset by shelves, drawers, blower coils, or cabinet protrusions. For specific cabinet dimensions and allowances, or for verification of clearancetolerances, contact our sales representative. Product performance may be affected by ambient temperature conditions, humidity conditions, sample loading preferences, and frequency of door openings. Contact our salesrepresentative for specific inquiries regarding your application.
RPR-1204 pharmacy refrigerator,shown with optional casters and
temperature recorder.
Temperature Range: +1°C to +8°C, factory preset to +4°C (auto defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Cabinet Door Drawers inches (mm) inches (mm) lb (kg)
RPR-1204A 11.5 115 (60) 9.4/15 (P1) upright single, 5 52.0 x 21.0 x 20.0 71.9 x 28.8 x 24.0 320 (145)RPR-1204V (326) 230 (50) 6.0/15 (P7) glass (1320 x 530 x 500) (1830 x 740 x 610)
RPR-2304A 23.3 115 (60) 9.4/15 (P1) upright single, 6 58.0 x 29.0 x 24.0 77.5 x 35.5 x 28.0 470 (213)RPR-2304D (659) 208/230 (60) 6.0/15 (P4) glass (1470 x 730 x 610) (1970 x 910 x 720)RPR-2304V 230 (50) 6.0/15 (P7)
RPR-3004A 29.2 115 (60) 9.4/15 (P1) upright single, 6 58.0 x 29.0 x 30.0 77.5 x 35.5 x 34.0 505 (227)RPR-3004D (826) 208/230 (60) 6.0/15 (P4) glass (1470 x 730 x 760) (1970 x 910 x 870)RPR-3004V 230 (50) 6.0/15 (P7)
RPR-5004A 51.1 115 (60) 15.0/20 (P2) upright double, 12 58.0 x 29.0 x 52.0 77.5 x 35.5 x 56.5 790 (359)RPR-5004D (1447) 208/230 (60) 8.5/15 (P4) glass (1470 x 730 x 1320) (1970 x 910 x 1440)RPR-5004V 230 (50) 8.5/15 (P7)
Our -30°C general laboratoryfreezers are designed for medicaland scientific applications suchas storage of reagents,pharmaceuticals, biologicals,or other commonly usedlaboratory materials. Modelsoffer cabinet sizes to fit a varietyof space needs and storagevolume requirements.
ULT-5030 (left) and ULT-2330 (right) -30°C freezers, shownwith optional casters and temperature recorder.
Our freezers feature the IntrLogicmicroprocessor control system,positive airflow systems, industrialquality cabinet construction andextra-strength refrigerationcompressors selected for industrial,clinical and scientific use.
IntrLogic Microprocessor Control
Our ULT series lab freezersfeature enhanced digital electronictechnology designed to simplifyoperation and deliver greateraccuracy (see pages 4 and 5).
• Pre-set -30°C operation
• Icon-based controls and displaysinclude graphic references foruniversal operation
• Setpoint security with key-operated triple-position masterswitch controls power toall systems for added safety
• Audible/visual warnings for over-temperature, undertemperatureand power failure, with visualstatus reports on critical functions
• Graphic thermometer confirmsproper operation at-a-glance,shows normal, high or lowtemperature condition; steadygreen for normal, flashing top barfor overtemperature, flashing bulbfor undertemperature
• Advanced defrost sensormanages the defrost cycle,minimizing trace amounts of frostbuild-up to maintain refrigerationcoil efficiency
• Enlarged digital display,resolution to within 0.1°C,improves visibility
• Push button alarm test verifiessensor continuity
• Battery backup assures controlpanel function during powerfailure
• Remote alarm contacts areincluded on all models
501662_Thermo 8/3/07 12:06 AM Page 14
15
ORDERING INFORMATION
* Published interior volumes are nominal; useable cu.ft. (L) capacities may be offset by shelves, drawers, blower coils, or cabinet protrusions. For specific cabinet dimensions and allowances, or for verification of clearancetolerances, contact our sales representative. Product performance may be affected by ambient temperature conditions, humidity conditions, sample loading preferences, and frequency of door openings. Contact our salesrepresentative for specific inquiries regarding your application.
Temperature Range: -30°C (auto defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Cabinet Door Shelves inches (mm) inches (mm) lb (kg)
ULT-430A 4.9 115 (60) 8.0/15 (P1) undercounter single, 3 20.0 x 20.0 x 20.0 33.4 x 26.0 x 24.0 212 (96)ULT-430V (133) 230 (50) 6.0/15 (P7) solid (500 x 500 x 500) (850 x 660 x 610)
ULT-1230A 11.5 115 (60) 8.0/15 (P1) space single, 4 52.0 x 21.0 x 20.0 71.9 x 28.8 x 24.0 280 (127)ULT-1230V (326) 230 (50) 8.0/15 (P7) saver solid (1320 x 530 x 500) (1830 x 740 x 610)
ULT-2330A 23.3 115 (60) 16.0/20 (P2) upright single, 58.0 x 29.0 x 24.0 77.5 x 35.5 x 28.0 370 (168)ULT-2330D (659) 208/230 (60) 12.0/15 (P4) solid 4 (1470 x 730 x 610) (1970 x 910 x 720)ULT-2330V 230 (50) 12.0/15 (P7)
ULT-3030A 29.2 115 (60) 16.0/20 (P2) upright single, 58.0 x 29.0 x 30.0 77.5 x 35.5 x 34.0 445 (202)ULT-3030D (826) 208/230 (60) 12.0/15 (P4) solid 4 (1470 x 730 x 760) (1970 x 910 x 870)ULT-3030V 230 (50) 12.0/15 (P7)
ULT-5030A 51.1 115 (60) 16.0/20 (P2) upright double, 58.0 x 29.0 x 52.0 77.5 x 35.5 x 56.5 600 (272)ULT-5030D (1447) 208/230 (60) 12.0/15 (P4) solid 8 (1470 x 730 x 1320) (1970 x 910 x 1440)ULT-5030V 230 (50) 12.0/15 (P7)
General Purpose Laboratory Freezers
Cabinet Constructionand Inventory System• Cabinet capacities from
Our plasma freezers featureenhanced digital electronictechnology designed to simplifyoperation and deliver greateraccuracy (see pages 4 and 5).
• Pre-set -30°C operation
• Icon-based controls and displaysinclude graphic references foruniversal operation
• Setpoint security with key-operated triple-position masterswitch controls power toall systems for added safety
• Audible/visual warnings for over-temperature, undertemperatureand power failure, with visualstatus reports on critical functions
• Graphic thermometer confirms
proper operation at-a-glance,shows normal, high or lowtemperature condition; steadygreen for normal, flashing top barfor overtemperature, flashing bulbfor undertemperature
• Advanced defrost sensormanages the defrost cycle,minimizing trace amounts of frostbuild-up to maintain refrigerationcoil efficiency
• Enlarged digital display,resolution to within 0.1°C,improves visibility
Our -30°C plasma freezers aredesigned to meet AABB, ANRCand FDA standards for safetyand performance in plasmastorage. Five models offercabinet sizes to meet a varietyof space needs and storagevolume requirements.
UFP-5030 (left) and UFP-1230 (right) plasma freezers areequipped with 7-day temperature recorders as standard toprovide an accurate record of storage temperature.
UFP-430 undercounter plasmafreezer shown with optional
finished countertop
501662_Thermo 8/3/07 12:06 AM Page 16
NALGENE and NUNC cryogenic storage give you everything you need to safelystore precious specimens, organize freezer space and simplify sample retrieval.NALGENE and NUNC combine to provide one-stop shopping for the widest variety andhighest quality of externally and internally threaded cryovials, storage boxes, lab topcoolers and “Mr. Frosty” controlled rate freezing containers.
For further information regarding these products – visit www.nalgene.com or www.nuncbrand.com17
ORDERING INFORMATION
* Published interior volumes are nominal; useable cu.ft. (L) capacities may be offset by shelves, drawers, blower coils, or cabinet protrusions. For specific cabinet dimensions and allowances, or for verification of clearancetolerances, contact our sales representative. Product performance may be affected by ambient temperature conditions, humidity conditions, sample loading preferences, and frequency of door openings. Contact our salesrepresentative for specific inquiries regarding your application.
** Nominal capacity based on 250 mL plasma boxes.
Temperature Range: -30°C (auto defrost)
Cu.Ft./L Int. Dimensions* Ext. Dimensions*(Plasma Box Voltage Amps/ H x D x W H x D x W Ship Weight
Model No. Capacity)** (Hz) Breaker (Plug) Cabinet Door Drawers inches (mm) inches (mm) lb (kg)
UFP-430A 4.9/133 115 (60) 8.0/15 (P1) undercounter single, 2 20.0 x 20.0 x 20.0 33.4 x 26.0 x 24.0 212 (96)UFP-430V (78) 230 (50) 6.0/15 (P7) solid (500 x 500 x 500) (850 x 660 x 610)
UFP-1230A 11.5/326 115 (60) 8.0/15 (P1) space single, 7 52.0 x 21.0 x 20.0 71.9 x 28.8 x 24.0 365 (166)UFP-1230V (273) 230 (50) 8.0/15 (P7) saver solid (1320 x 530 x 500) (1830 x 740 x 610)
UFP-2330A 23.3/659 115 (60) 16.0/20 (P2) upright single, 7 58.0 x 29.0 x 24.0 77.5 x 35.5 x 28.0UFP-2330D (532) 208/230 (60) 12.0/15 (P4) solid (1470 x 730 x 610) (1970 x 910 x 720) 425 (193)UFP-2330V 230 (50) 12.0/15 (P7)
UFP-3030A 29.2/826 115 (60) 16.0/20 (P2) upright single, 7 58.0 x 29.0 x 30.0 77.5 x 35.5 x 34.0UFP-3030D (665) 208/230 (60) 12.0/15 (P4) solid (1470 x 730 x 760) (1970 x 910 x 870) 580 (263)UFP-3030V 230 (50) 12.0/15 (P7)
UFP-5030A 51.1/1447 115 (60) 16.0/20 (P2) upright double, 14 58.0 x 29.0 x 52.0 77.5 x 35.5 x 56.5 650 (295)UFP-5030D (1064) 208/230 (60) 12.0/15 (P4) solid (1470 x 730 x 1320) (1970 x 910 x 1440)UFP-5030V 230 (50) 12.0/15 (P7)
Our -20°C freezers feature theIntrLogic microprocessor controlsystem, gravity air circulation,industrial quality cabinetconstruction, and extra-strengthrefrigeration compressors selectedfor industrial, clinical and scientificuse.
The UEN-2320 enzyme freezerfeatures an easily accessibleinventory system, while the UGL-2320 general lab freezer offersflexible utility value with four-wireshelves.
IntrLogic Microprocessor Control
Our -20°C enzyme and laboratoryfreezers feature enhanced digitalelectronic technology designed tosimplify operation and deliver greateraccuracy (see pages 4 and 5).
• Pre-set -20°C operation
• Icon-based controls and displaysinclude graphic references foruniversal operation
• Setpoint security with key-operated triple-position masterswitch controls power toall systems for added safety
• Audible/visual warnings for over-temperature, undertemperatureand power failure, with visualstatus reports on critical functions
• Graphic thermometer confirmsproper operation at-a-glance,shows normal, high or lowtemperature condition; steadygreen for normal, flashing top barfor overtemperature, flashing bulbfor undertemperature
• Enlarged digital display,resolution to within 0.1°C,improves visibility
• Push button alarm test verifiessensor continuity
• Battery backup assures controlpanel function during powerfailure
• Remote alarm contacts arestandard onall models
Our manual defrost -20°Cupright freezers are designed forstorage applications whereslight intermittent coil warmingduring an auto defrost cycle isnot desired. Two models featuregravity convection air systemsfor maximum stability withoutblowers or fans.
The -20°C UEN-2320 enzyme freezerstores 45 enzyme bins on 9 shelves.Shown with optional casters andtemperature recorder.
High impact plastic enzymestorage bins enable easily
accessible, highly concentratedinventory storage. Additionalbins are useful for managing
loose material in generalpurpose applications; see
Accessories section.
501662_Thermo 8/3/07 12:07 AM Page 18
19
ORDERING INFORMATION
Temperature Range: -20°C (manual defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Cabinet Door Shelves inches (mm) inches (mm) lb (kg)
UEN-2320A 23.3 115 (60) 13.5/20 (P2) upright single, 9 58.0 x 29.0 x 24.0 77.5 x 35.5 x 28.0 425 (193)UEN-2320D (659) 208/230 (60) 5.6/15 (P4) solid (1470 x 730 x 610) (1970 x 910 x 720)UEN-2320V 230 (50) 5.6/15 (P7)
Enzyme Freezers
* Published interior volumes are nominal; useable cu.ft. (L) capacities may be offset by shelves, drawers, blower coils, or cabinet protrusions. For specific cabinet dimensions and allowances, or for verification of clearancetolerances, contact our sales representative. Product performance may be affected by ambient temperature conditions, humidity conditions, sample loading preferences, and frequency of door openings. Contact our salesrepresentative for specific inquiries regarding your application.
Temperature Range: -20°C (manual defrost)
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ H x D x W H x D x W Ship Weight
Model No. (L) (Hz) Breaker (Plug) Cabinet Door Shelves inches (mm) inches (mm) lb (kg)
UGL-2320A 23.3 115 (60) 13.5/20 (P2) upright single 4 58.0 x 29.0 x 24.0 77.5 x 35.5 x 28.0 425 (193)UGL-2320D (659) 208/230 (60) 5.6/15 (P4) solid (1470 x 730 x 610) (1970 x 910 x 720)UGL-2320V 230 (50) 5.6/15 (P7)
All our refrigerated incubatorsinclude both heating andrefrigeration systems withmicroprocessor-based control,digital temperature display andhigh quality cabinet construction.Refrigeration systems may beturned off when not required.Choose from programmable andnon-programmable models.
BOD-50A refrigeratedincubator.
* Published interior volumes are nominal; useable cu.ft. (L) capacities may be offset by shelves, drawers, blower coils, or cabinet protrusions. For specific cabinet dimensions and allowances, or for verification of clearancetolerances, contact our sales representatives. Product performance may be affected by ambient temperature conditions, humidity conditions, sample loading preferences, and frequency of door openings. Contact our salesrepresentatives for specific inquiries regarding your application.
Programmable and Non-Programmable Incubator/Refrigerator/Freezer
Int. Dimensions* Ext. Dimensions*Cu.Ft. Voltage Amps/ Shelves H x D x W H x D x W Ship Weight
BOD Refrigerated Incubator, Programmable, Automatic Defrost, Temperature Range Adjustable -20°C to +60°C
BOD-50A 20.0 (566) 115 (60) 10.6/15 (P1) 4/0 1 basket 56.0 x 22.0 x 28.0 72.5 x 29.0 x 33.0 300(1420 x 550 x 710) (1850 x 740 x 840) (136)
BOD Refrigerated Incubator, Non-programmable, Manual Defrost, Temperature Range Adjustable 0°C to +50°C
BOD-10A 6.1 (173) 115 (60) 2.9/15 (P1) 1/1 28.0 x 21.0 x 21.0 35.8 x 25.5 x 23.9 115(710 x 530 x 530) (910 x 650 x 610) (52)
BOD Refrigerated Incubator, Non-programmable, Automatic Defrost, Temperature Range Adjustable -15°C to +60°C
BOD-30A 20.0 (566) 115 (60) 10.6/15 (P1) 4/0 1 basket 56.0 x 22.0 x 28.0 72.5 x 29.0 x 33.0 300(1420 x 550 x 710) (1850 x 740 x 840) (136)
Refrigerated Incubators
Programmable Model BOD-50• Applications include shelf life
and life cycle testing, generalincubation or refrigerated storage
• Temperature range adjustablefrom -20°C to +60°C
• Microprocessor controlwith full programmability
• Digital temperature displayand keyed on/off switch
• Forced air circulation formaximum temperature uniformity
• Temperature alarm system withadjustable high/low alarm limits,includes audible and visualwarning on high limit deviationand visual warning on low limit
• CFC-free urethane insulatedcabinet with corrosion-resistantseamless interior
• Scratch-resistant whiteacrylic exterior finish
• Keyed door lock for improvedsecurity with magnetic door gasket
• Open wire shelves on 10" (254mm) centers with more than 20sq. ft. of shelf space, plus oneutility basket
• Air-cooled, hermetically sealedindustrial type compressor
• Automatic defrost withcondensate evaporator; no drainrequired (defrost indicator onBOD-50)
• Remote alarm contacts standard
Non-programmable Models• Adjustable temperature
control, forced-air circulation
• Microprocessor-based controlwith digital temperature display,keyed on/off switch
• Air-cooled, hermetically sealedindustrial type compressor(see chart for defrost mode)
• CFC-free urethane insulatedcabinet with corrosion-resistantABS seamless interior
• Scratch-resistant whiteacrylic exterior finish
• Keyed door lock for improvedsecurity (except model BOD-10)
Stainless Steel, n/a 6202-1 6696-1 6695-1 6696-1 6696-1 6696-1Full-Size Only
21
Accessories Productive use of our refrigeratoror freezer can be enhancedwith accessories speciallydesigned to improve utility andconvenience. Many accessoriesare factory installed andmust be specified with youroriginal order.
Field installed accessories mayrequire the services of a factoryauthorized technician.
Some accessories or optionsmay affect refrigerator orfreezer performance; for moreinformation contact your SalesRepresentative.
Voltage safeguard
Voltages and Serial NumbersSerial number tags on all our Revcoproducts contain model numbersand voltage information needed foraccurate selection of accessoriesordered for field installation.
• It is recommended thataccessories be ordered whenyour refrigerator or freezer isordered
• Factory-installed accessoriesallow proper set-up withoutpower-down or emptyingthe cabinet
Validation Testing ProgramValidation testing services inadvance of shipment canaccelerate in-house FDA InstallationQualification (IQ) and OperationQualification (OQ) programs.Validation services includedocumentation and performancereports, compressor and sub-system component specifications,microprocessor flow diagrams,software specifications and more.For more details, contact your salesrepresentative.
Certification of CalibrationControl, alarm and temperaturerecording systems aresystematically calibrated at thefactory for accurate performance.An optional Certificate ofCalibration to an NIST (NationalInstitute of Standards andTechnology, formerly NationalBureau of Standards) traceableinstrument includes a modelnumber and serial numbercertificate and single point
ShelvesAdditional epoxy-coated, open-wireshelves are designed to fit individualcabinets; shelves are available infull- and half-sizes. Undercountermodels use full-size only.
calibration. Multiple pointcalibration is also available.Calibration certificates must berequested when ordering.
Catalog No. 6916-2
Voltage SafeguardHelps protect refrigerator orfreezer from damage by automati-cally boosting low voltage. Includesterminal board for direct wiring.Free-standing, field installed.
Glass DoorsSolid doors are offered standard onmost refrigerators unless otherwisespecified. Optional dual-pane glass doors must be specified when ordering.Contact your Sales Representative for information on heated glass doors.
Swing Type Catalog Numbersolid 7119 6995 6997 6999
LH = Left Hand, RH = Right Hand Note: Glass doors are standard on selected blood bank, chromatography and pharmacy refrigerators; consult specification chart for details.Sliding glass doors are standard on all 45.8 cu.ft. (1297 L) models. Heated glass doors will increase amperage and may require next size breaker.
506877 Thermo:501662_Thermo 5/8/08 1:33 AM Page 21
Roll-Out DrawersOptional stainless steel drawers,offered as an alternative tostandard open wire shelving, areadjustable with full extension.Drawers are factory installed andmust be specified when orderingcabinet.
Surge SuppressorSurge suppressors provideadditional protection againstvoltage transients which maydamage refrigeration or controlcomponents. Independent modulerequires field installation by aqualified electrician or factoryauthorized service technician.Model number and voltage mustbe specified when ordering.
Catalog No. 6402
Accessories
Temperature recorder
CastersCasters are optional on mostmodels. Casters are factoryinstalled when ordered at time ofcabinet order; customer installed ifordered separately. Choose from 2"(50 mm) or 3" (76 mm) casters.
Temperature RecordersOptional 6" (152 mm) chart,7-day temperature recorders usepressure-sensitive chart paper; onebox of 50 charts included. Built-inrecorders must be specified whenordering. Recorders are standardon 11.5 cu.ft. (326 L) and largerblood bank refrigerators andplasma freezers.
LabCooler™
ModulesLabCoolerBenchtopcooler helpsmaintainenzymes andother frozenmaterial atstabletemperatureswhen used atthe lab bench.When storedin a freezer,coolers insulateenzymes
and other biologicals from periodictemperature fluctuations due todoor openings, defrost cyclesor temporary power outages ofshort duration. Choose from twomodels.• The LabCooler II Benchtop Cooler
maintains enzymes at stable -20oC for up to two hours. Holds(24) 1.5 ml tubes and (8) 0.5 mltubes.
• The LabCooler Lite BenchtopCooler is smaller and morecompact, maintains enzymetemperatures at -10oC orbelow for up to one hour outsidethe freezer. Holds up to (7)1.5 ml tubes. Includes a clearinterlocking top.
Cooler II Catalog No. 6744LabCooler Lite Catalog No. 6745
Deluxe ElectronicRemote AlarmThe deluxeelectronic remotealarm can beprogrammed to
sound an alarm in the event ofa temperature increase or powerfailure.• The alarm can dial up to
four telephone numbers
• Advises of an alarm conditionacross any telephone systemwhich accepts pulse dialing
• One system can monitor up tofour individual freezers or up tothree groups of freezers (availablein 115V/60Hz only)
• Requires dedicated phone line
Catalog No. 6224
RemoteAlarm ModuleFor audibleand visualsignal in theevent oftemperaturerise or power
failure. Can be located up to 1760feet (536 meters) from cabinet.Must be used with electronic alarmsystem and connected to normallyopen or normally closed remotealarm contacts. Wire not included.Specify refrigerator or freezervoltage when ordering (available in115V/60Hz only).
Additional bins are useful forstorage and inventorymanagement. Formed of highimpact ABS plastic, off-white.Labels not included.
Catalog No. 6736
Alarm Delay ModuleThe alarm delayeliminates nuisancealarms due tointermittent ortransitory conditionssuch as lightning orbrief power outages.The adjustable delay requires analarm condition to exist continuouslyfor a pre-determined time(adjustable) before a signal isreleased to a central alarm/monitoring system or telephonedialer.
• Adjustable delay from 0.5 to32 minutes
• Red alarm indicator light remainsflashing after transient condition iscorrected; requires manual reset
• Signals chronic alarm conditionswhich may indicate impendingcomponent failure; allows timefor inspection or correctivemaintenance
• Inserts variable time intervalbetween detection of alarmcondition and transmission ofsignal
• Includes accurate digital timingcircuit adjustable from 0.5, 1, 2,4, 8, 18, or 32 minutes
• Operates independent of linepower; built-in battery and alarmtest function uses customersupplied 9V battery
Catalog No. 6903
Access PortAdditional port for probes, cables,leads or measuring instrumentsmay be added to any cabinet. Portis 1" (25 mm) diameter for freezersand 2" (50 mm) for refrigerators.Location must be specified whenordering. 2" for Refrigerators andFreezers.
Interior Dimensions (nominal)3.5"W (90 mm) x 3"H (76 mm) x 24"L (610 mm)
Exterior Dimensions (nominal)
4.4"W (112 mm) x 3.04"H (77 mm) x 25.25"L (641 mm)
Digital Temperature MonitorSimple,accurate andcost-effective,the digitaltemperature
and power monitor provides bothalarm/monitoring and digitaltemperature display in a single, self-contained unit. Standard featuresinclude high alarm, alarm mute andchirp, audio delay timer, remotealarm contacts (SPDT), NiCadbattery backup, and low voltage ACpower supply, 120V, AC.• The monitor can be installed on or
adjacent to any refrigerator orfreezer
• Activates an audible and visualwarning in case of power failureor overtemperature condition
• Choose from single probe digitalmodels or multiple probe,microprocessor-based models
• Temperature range is -100°C to+25°C
• Probe size 1.25"L x 0.25" diameter(32 mm x 6 mm)
CFC-Free Refrigerants, Insulation andPackagingAll our refrigerators and freezersuse CFC-free refrigerants, cabinetinsulation and packaging.
Product SelectionThis catalog is divided into sectionsaccording to general productapplication. Because most controllersallow adjustable setpoints, alltemperatures are listed as designoperating temperatures andtypically represent the lowest orcoldest temperature of atemperature range.
Electrical InformationThermo Scientific Revco refrigeratorsand freezers are designed to meetUL, CUL, CE and TUV criteria forsafety and performance. Allconnections must comply withlocal electrical codes.
• Selection charts for each standardmodel list voltage, rated amperage,recommended circuit breaker size,and NEMA (National ElectricalManufacturers’ Association, USA)electrical plug information
• Most refrigerators and freezersare supplied with line cord plugs(P) which require correspondingreceptacles illustrated on the linecord plug reference chart to theright
• Site preparation requiresavailability of the proper receptacle;a dedicated circuit is recommended
• Special voltage selections may beavailable at extra cost and mustbe specified when ordering
Certification of CalibrationControl, alarm and temperaturerecording systems are systematicallycalibrated at the factory for accurateperformance. An optional Certificateof Calibration to an NIST (NationalInstitute of Standards andTechnology, formerly NationalBureau of Standards) traceableinstrument includes a ModelNumber and Serial NumberCertificate (single point calibration).Multiple point calibration is alsoavailable. Calibration certificatesmust be requested when ordering;for details contact our salesrepresentatives.
Validation Testing ProgramValidation testing services inadvance of shipment can acceleratein-house FDA InstallationQualification (IQ) and OperationQualification (OQ) programs.Validation services includedocumentation and performancereports, compressor and sub-system component specifications,microprocessor flow diagrams,software specifications and more.For more details, contact our salesrepresentatives.
Performance DataFor detailed performanceinformation such as temperaturerecovery, power consumption andother model-specific operationalcharacteristics, contact our salesrepresentatives.
Ordering InformationOur sales representatives willassist in choosing the properrefrigerator or freezer for yourapplication.
• Each model number is voltagespecific. For clarity, please includethe voltage of your selectedrefrigerator or freezer whenordering
• When ordering your refrigeratoror freezer, please consider currentor future accessory requirementssuch as temperature recorders,extra shelves andalarm/monitoring systems
• Many accessories are factoryinstalled and must be specifiedwhen ordering
Specifications
Models with have this require this NEMA Reference
this code plug receptacle Plug Receptacle
P1 5-15P 5-15R
P2 5-20P 5-20R
P3 5-30P 5-30R
P4 6-15P 6-15R
P5 6-20P 6-20R
P6 6-30P 6-30R
P7 European
Line Cord Plug Reference
Refrigerators and freezers supplied with line cord plugs (P) requirecorresponding receptacles illustrated in the Line Cord Plug Reference. Catalogselection charts list each standard model with voltage, rated amperage,recommended circuit breaker size and NEMA electrical plug information.
North America: USA/Canada +1 866 984 3766 www.thermo.com/coldEurope: Austria +43 1 801 40 0, Belgium +32 2 482 30 30, France +33 2 2803 2000, Germany national toll free 08001-536 376,Germany international +49 6184 90 6940, Italy +39 02 02 95059 434-254, Netherlands +31 76 571 4440, Nordic countries +358 9 329 100,Russia/CIS +7 (812) 703 42 15, Spain/Portugal +34 93 223 09 18, Switzerland +41 44 454 12 12, UK/Ireland +44 870 609 9203Asia: China +86 21 6865 4588 or +86 10 8419 3588, India +91 22 6716 2200, Japan +81 45 453 9220, Other Asian countries +852 2885 4613Countries not listed: +49 6184 90 6940 or +33 2 2803 2000 BRO-LECS-HPRFR-0508
506877 Thermo:501662_Thermo 5/8/08 1:34 AM Page 24