Transcript
USN 10cv46
Fourth Semester B.E. Degree Examination, June/July 2014
Building Planning and Drawing
Time: 4 hrs. Max. Marks:100Note: l. SECTION-I is compulsory and answer" "-7.i ..Jn' r:.;; :.::::,::i-^:'7;;;,7",uny TWO faII q uestio ns from SE CTI ON-II.
2. Assume saitable data wherever necessary.
SECTION - I (Compulsory)t The line diagram of a t.rGT[t UrritAltrg is given in f ig.Qt. Draw to a scale of 1:100.
(25 Marks)(15 Marks)(15 Marks)(05 Marks)
aio
<d
c..J
CJ
c6Q)
9?O
=r)oo ll
<oo.=Ncn\t
HoeO
EE
a:i
r(J
(€d
>!H=
'od
?oao-or!oi./' .=6:aLE
!o6.:>'!bo"co0cJ=p. hiF>XoO
iJ<
-a{()o
I
o.
a. Plan at sill levelb. Front elevationc. Section along A-Ad. Schedule of openings
Note: All load bearing walls are 230 mm thick and partition walls are 115 mm thick. Allwalls are in BBM of CM 1:6. The foundation is made of SSM in CM 1:6. The depth of thefoundation is 1.2 m below ground level. The thickness of plinth bed is 150 rnm, thickness ofRCC 150 mm. the clear height of the roof from floor level is 3.1 m, and lintel are provided at2.1 m.
wl
Wr :1.2mx1.5mWs:1.2mx1.5mDz:1.0mx2.1m
I
*lFig.Q1
Wz:1.2mxI.2mVr:1.0mx0.6mDr :0.9 mx 2.1m
W::1.5mx l.2mYz:OAmx0.6m
I of2
W+ : 1 .2mx 0.75 mDr:L2mx2.tm
BED ROOM4X4
10cv46
SECTION. II2 a. Draw cross section of a S.S. Masonry foundation to be provided for a load bearing wall of
230 mm thick brick wall. Use following data:
vii) Height of plinth above ground level0.6 m excluding the thickness of plinth beam.(10 Marks)
Draw the front elevation and sectional plan view of fully glazed double shuttered window ofsize 1.2 m x 1.2 m. (10 Marks)
Prepare a bubble diagram and develop a line diagram for a primary health centre to asuitable scale. The primary health centre should consists ofi) Reception ii) Doctor's consultation roomiii) Lady docfor's room iv) Minor operation theatre
(20 Marks)
i) Width of foundation: 1.2 miii) Width of P.C.C. : l.2mv) Width of plinth beam: 0.45 m
i) Receptioniii) Office staff roomv) Small meeting hall
ii) Depth of foundation: 1.5 miv) Thickness of P.C.C.: CM 1:3:6: 100 mmvi) Thickness of plinth beam: 100 mm
,ii) Execution office chambers - 2 Nosiv) Record roomvi) Toilets for ladies and gents separately. (20 Marks)
v) Nurse room vi) Dispensaryvii) Store room viii) Laboratoryix) Toilets for ladies and gents separately.
4 Prepare a bubble diagram for a office building and draw a single line diagram to a suitablescale for the following requirements.
a.
b.
The line diagram of a residential building is shown in Fig.Q5. Prepare:Water supply layoutElectrical layout.
Fig.QsAssume suitable dimensions for doors and windows.
{<*x<t<*
(20 Marks)
2 of2