Transcript
8/13/2019 Thermocouple Tips
http://slidepdf.com/reader/full/thermocouple-tips 1/3
LMMLustre Metals & Minerals Sdn Bhd (Co No. 765239-M)
D2-6-13A, Solaris Dutamas, No. 1, Jalan Dutamas 1,
50480 Kuala Lumpur, Malaysia.
Tel: +603-62079552 Fax: +603-62079553 Email: lmm_info@streamyx.com METALS & MINERALS
Page 1 of 3
Thermocouple Tips
Thermocouples are the most popular temperature sensors. They are
cheap, interchangeable, have standard connectors and can measure awide range of temperatures. The main limitation is accuracy, system
errors of less than 1°C can be difficult to achieve.Ajay Syscon has developed and designed thermocouple tips to detect
and measure temperature using thermocouples of various types like B,K, R and S type.
We manufacture expendable immersion type thermocouple tips with
spiral cardboard paper tube which are fitted on to lance pipe and used to take the temperature of
molten metal in foundry and steel plants.
When immersed in the molten metal for 4 to 6 seconds the process of millivolt transfer to the
microprocessor starts and the temperature is displayed on the display unit.
Overview of our range of thermocouple tips are as follows: MINI
ü THERMOCOUPLE TIP MINI 10% (TYPE S) / 13%
(TYPE R) / 6/30% (TYPE B) WITH PAPER TUBE
LENGTH OF 300 TO 1500MM AS REQUIRED
ACCORDING TO FURNACE CAPACITY.
ü Minitip is used especially for foundry plants
ü Connector type is male
ü Supporter type is Plastic
ü Accuracy: 1deg Celsius
ü Usage: Single time used
ü ID/OD: 18MM/32MM
MARK VII
ü THERMOCOUPLE TIP MARK VII 10% (TYPE S) /
13% (TYPE R) / 6/30% (TYPE B) WITH PAPER
TUBE LENGTH OF 300 TO 1500MM AS REQUIRED
ACCORDING TO FURNACE CAPACITY.ü Mark VII is used especially for Steel plants
ü Connector type is Male Female
ü Supporter type is plastic / ceramic as required
ü Accuracy: 1deg Celsius
ü Usage: Single time used
ü ID/OD: 18MM/32MM
ü Metal Cap: M.S / AL / CU
8/13/2019 Thermocouple Tips
http://slidepdf.com/reader/full/thermocouple-tips 2/3
LMMLustre Metals & Minerals Sdn Bhd (Co No. 765239-M)
D2-6-13A, Solaris Dutamas, No. 1, Jalan Dutamas 1,
50480 Kuala Lumpur, Malaysia.
Tel: +603-62079552 Fax: +603-62079553 Email: lmm_info@streamyx.com METALS & MINERALS
Page 2 of 3
ANTISPLASH
ü THERMOCOUPLE TIP ANTISPLASH / SAFETIP /
MULTI DIP 10% (TYPE S) / 13% (TYPE R) / 6/30%(TYPE B) WITH PAPER TUBE LENGTH OF 300 TO
900MM AS REQUIRED ACCORDING TO
FURNACE CAPACITY.
ü Brand Name: Safetip
ü Accuracy: 1deg Celsius
ü Usage: Can be used 10-12 times in slag free condition
and avoids spurting and splashing
ü ID/OD: 18MM/32MM
ü Safetip is used especially for foundry and Steel plants
ü Connector type is Mini (Male) / Mark VII (Male Female)
ü Supporter type is Plastic
ü Coating: Ceramic sleeve of 75 / 150MM as per requirement
BIG MULTI DIP
ü THERMOCOUPLE TIP BIG MULTI DIP (BMD) 10%
(TYPE S) / 13% (TYPE R) / 6/30% (TYPE B) WITH
CERAMIC SLEEVE OF 70MM.
ü Brand Name: BMD
ü Accuracy: 1deg Celsius
ü Usage: Can be used 8-10 times in slag free condition,
only used for 1 metric ton induction furnace and ladle
furnace
ü Outer shell is Ceramic
ü Connector type is Mini (Male)
ü BMD is used especially for foundry and Steel plants
8/13/2019 Thermocouple Tips
http://slidepdf.com/reader/full/thermocouple-tips 3/3
LMMLustre Metals & Minerals Sdn Bhd (Co No. 765239-M)
D2-6-13A, Solaris Dutamas, No. 1, Jalan Dutamas 1,
50480 Kuala Lumpur, Malaysia.
Tel: +603-62079552 Fax: +603-62079553 Email: lmm_info@streamyx.com METALS & MINERALS
Page 3 of 3
CARBON CUPS
These are sampling cups with accurate thermocoupleassembly and Tellurium blob to get more reliable Thermal
Analysis results of CE, C, Si. These are especially made for
High Carbon equivalent of Cast Iron / S. G. Iron, giving
consistent and accurate C & Si readings.
Salient features include:
- Economical
- High Reliability
- Accurate Results
- No Chance of Loose Contacts
Technical specifications:
· Type B (Platinum / Rhodium)Type B is suited for high temperature measurements up to 1800°C. Unusually type B thermocouples (due
to the shape of their temperature / voltage curve) give the same output at 0°C and 42°C. This makes them
useless below 50°C.
· Type K (Chromel / Alumel)
Type K is the 'general purpose' thermocouple. It is low cost and, owing to its popularity, it is available ina wide variety of probes. Thermocouples are available in the -200°C to +1300°C range. Sensitivity is
approx 41uV/°C. Use type K unless you have a good reason not to.
· Type R (Platinum / Rhodium)Type R is suited for high temperature measurements up to 1720°C. Low sensitivity (10uV/°C) and highcost makes them unsuitable for general purpose use.
· Type S (Platinum / Rhodium)Type S is suited for high temperature measurements up to 1720°C. Low sensitivity (10uV/vC) and high
cost makes them unsuitable for general purpose use. Due to its high stability type S is used as the
standard of calibration for the melting point of gold (1064.43°C).