STATE COLLEGE OF FLORIDA LWR... · 78.00 78.00 a2.1 lifesafety plans a2.1 1 lifesafety plan - first floor scale: 3/32" = 1'-0" hepner architects, incorporated 601 s. boulevard, suite

Post on 27-Jul-2020

5 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

Transcript

A0.0

COVER SHEET

HEPNER ARCHITECTS, INCORPORATED601 S. BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617

DATEDISTRIBUTION

PROJECT NO.

TO THE BEST OF THE ARCHITECT'S KNOWLEDGETHE PLANS AND SPECIFICATIONS ARE COMPLETEAND COMPLY WITH THE FLORIDA BUILDING CODE

COPYRIGHT 2019, HEPNER ARCHITECTS, INCORPORATED. ALL RIGHTS RESERVED

3168

CONSTRUCTION DOCUMENTS 02/04/2019

UPGRADESINTERIORLWR MTSCSCF

7131 PROFESSIONAL PKWY E.SARASOTA , FL 34240

SCF PROJECT # 7-19-3-12

ENGINEERING MATRIX, INC.2860 SCHERER DR N.ST. PETERSBURG, FLORIDA 33716727-473-4656CERT AUTH NO. 4288

PETER M. HEPNER, AIAAR 0010922

PROJECT LOCATIONLOCATION MAP (LOCAL)NOT TO SCALE

INDEX

DRAWING SYMBOL AND IDENTIFICATION LEGEND

ARCHITECTURAL ABBREVIATIONS

& ANDL ANGLE@ ATx BYC CENTER LINE- NONE REQUIREDP PLATE

A/C AIR CONDITION (-ER) (-ING)AB ANCHOR BOLTAC P ACOUSTICAL PANEL CEILINGAC T ACOUSTICAL TILEAC W ACOUSTICAL WALL SYSTEMADJ ADJUSTABLEAFF ABOVE FINISHED FLOORALM ALUMINUMALT ALTERNATEAPPROX APPROXIMATELY

BLDG BUILDINGBLKG BLOCKINGBM BEAMBRK BRICKBUR BUILT-UP ROOFING

CB CATCH BASINCEM PLS CEMENT PLASTER (PORTLAND)CHKBD CHALKBOARDCLG CEILINGCLO CLOSETCMU CONCRETE MASONRY UNITCOL COLUMNCONC CONCRETECONF CONFERENCECONST CONSTRUCTIONCONT CONTINUOUSCORR CORRIDORCPT CARPETCR CLASSROOMCT CERAMIC MOSAIC TILECTRJT CONTROL JOINTCUS CUSTODIAN'S UTILITY SHELF

D DEEP, DEPTHDBL DOUBLEDF DRINKING FOUNTAINDIA, Ø DIAMETERDIM DIMENSIONDN DOWNDNSP DOWNSPOUTDP DAMPPROOFINGDR DOORDTL DETAILDWG DRAWING

EA EACHELEC ELECTRICALEL ELEVATIONELEV ELEVATORENCL ENCLOSUREEQ EQUALEQUIP EQUIPMENTETC ET CETERAEWC ELECTRICAL WATER COOLEREXIST EXISTINGEXP JT EXPANSION JOINTEXT EXTERIOR

FD FLOOR DRAINFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETFH FIRE HYDRANTFHC FIRE HOSE CABINETFIN FINISHFL FLOORFLDR FOLDING DOOR

FRTW FIRE RETARDANT TREATED WOODFSS FOLDING SHOWER SEATFT FEETFTG FOOTING

GA GAUGEGALV GALVANIZEDGB GRAB BARGC GENERAL CONTRACTORGCT GLAZED CERAMIC MOSAICGL GLASS, GLAZINGGT GLAZED WALL TILE

GWC GLAZED WALL COATINGGYP BD GYPSUM BOARDGYPLS GYPSUM PLASTER

H HEIGHT, HIGHHC HOLLOW COREHD HAND DRYERHDW HARDWAREHM HOLLOW METALHNRL HANDRAILHORIZ HORIZONTAL(LY)HR HOUR

ID INSIDE DIAMETERINSUL INSULATIONINT INTERIORINV INVERT

JAN JANITORJT JOINT

LA LANGUAGE ARTSLAM LAMINATEDLAV LAVATORYLLH LONG LEG HORIZONTALLMC LINEAR METAL CEILINGLW LIGHTWEIGHT

M MIRRORM/S MIRROR/SHELFMAINT MAINTENANCEMAT'L MATERIALMAX MAXIMUMMECH MECHANICALMFR MANUFACTURERMH MANHOLEMIN MINIMUMMN MINUTEMO MASONRY OPENINGMPU MULTI-PURPOSE UNIT

MTD MOUNTEDMTL METAL

NIC NOT IN CONTRACTNO.,# NUMBERNOM NOMINAL NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETEROPNG OPENINGOPP OPPOSITE

PART'N PARTITIONPF RF PREFORMED ROOFINGPLBG PLUMBINGPLS PLASTERPNT PAINT (PAINTED FINISH)PROJ PROJECTPT PRESSURE TREATEDPTD PAPER TOWEL DISPENSERPTD/WR PAPER TOWEL DISPENSER /WASTE

RECEPTACLEPWD PLYWOOD

QT QUARRY TILE

R RADIUSR/W RIGHT-OF-WAYRCP REINFORCED CONCRETE PIPERD ROOF DRAINREBAR REINFORCING BARRECT RECTANGULARREINF REINFORCEMENTREQ'D REQUIREDRES F RESINOUS FLOORINGREV REVERSERFG REFRIGERATORRH ROBE HOOKRM ROOMRP RT RAISED PROFILE RUBBER TILERT RUBBER TILE

S/H SEALER/HARDENERSC SOLID CORESCI SCIENCESCR SHOWER CURTAIN/ROD SD SOAP DISPENSERSFT GL SAFETY GLASSSH SOAP HOLDERSHO SHOWERSHO C SHOWER CONTROLSSHO H SHOWER HEADSIM SIMILARSND SANITARY NAPKIN DISPOSAL SNV SANITARY NAPKIN VENDOR SNV/D SANITARY NAPKIN VENDOR/DISPOSAL SP C SPECIAL COATINGSPECS SPECIFICATIONSSQ SQUARESS STAINLESS STEELSTC SOUND TRANSMISSION CLASS (RATING)STD STANDARDSTL STEELSTOR STORAGESTR STRUCTURALSUPPL SUPPLEMENTARYSUS SUSPENDEDSW SWITCH

T TOILETT&G TONGUE AND GROOVETB TOWEL BARTHR THRESHOLDTKBD TACKBOARDTMP TEMPEREDTPO TEACHER PLANNING OFFICETTD TOILET TISSUE DISPENSERTYP TYPICAL, (UNLESS OTHERWISE NOTED)

U URINALUON/ UNO UNLESS OTHERWISE NOTED

V VINYLVCT VINYL COMPOSITION TILEVERT VERTICALVEST VESTIBULEVSF VINYL SHEET FLOORINGVT VINYL TILE

W/ WITHWC WALL COVERINGWD WOODWR WASTE RECEPTACLEWWF WELDED WIRE FABRIC

OH OPPOSITE HAND

MRKBD MARKERBOARD

DETAIL SYMBOL

EXTERIOR ELEVATION SYMBOL

SECTION SYMBOL

NORTH ARROW

VERTICAL ELEVATION MARK

INTERIOR ELEVATION SYMBOL

DETAIL NUMBER

DRAWING NUMBER

SIGNAGE TYPESPECIFICATION SECTION 101423

DETAIL INDICATION

DETAIL NUMBER

DRAWING NUMBER

DETAIL NUMBER

DRAWING NUMBER

DETAIL NUMBER

DRAWING NUMBER

DETAIL NUMBER

DRAWING NUMBER

SECTION "CUT LINE"

DETAIL AREA

INDICATES ELEVATION TO BE VIEWED

INDICATES ELEVATION TO BE VIEWED

CENTERLINE OF REFERENCE GRIDCOLUMN LINE SYMBOL

DOOR SYMBOL

DOOR NUMBER

DOOR TYPE / FRAME TYPE

WINDOW TYPE / STOREFRONT TYPE / LOUVER TYPE

FLOOR FINISH TYPE

INSTRUCTIONAL AIDS TYPE

TOILET ACCESSORY TYPE

GLAZING TYPE

KITCHEN EQUIPMENT TYPE

EQUIPMENT NUMBER

ROOM NUMBER IDENTIFICATION

NOTE NUMBERSPECIFIC NOTE INDICATION

1A11.1

1A9.1

1A10.1

113.1

1A11.1

100A.1

1

102

D

FT#

1

A

A

1

23

1

LIFE SAFETY OCCUPANT CAPACITY

+100'-0" SPOT ELEVATION

# WALL TYPE

1

8004020

GENERALA0.0 INDEX/SYMBOL AND IDENTIFICATION LEGEND

ARCHITECTURALA2.1 LIFE SAFETY PLANSA4.1 DEMOLITION PLAN - FIRST FLOORA5.1 NEW FLOOR PLAN - FIRST FLOORA5.2 NEW FLOOR PLAN - SECOND FLOOR

MECHANICALM0.0 MECHANICAL GENERALM2.1 FIRST FLOOR PLANS MECHANICAL

ELECTRICALE0.0 ELECTRICAL GENERAL SHEETE2.1 FIRST FLOOR PLANS - LIGHTINGE2.2 SECOND FLOOR PLANS - LIGHTINGE3.1 FIRST FLOOR PLANS - ELECTRICALE3.2 SECOND FLOOR PLANS - ELECTRICAL

NOTE: WHEN PLURAL OF A TERM IS INTENDED, THE SUFFIX "S" WILL BE ADDED TO ITS ABBREVIATION.

F.O. FACE OF

GWB GYPSUM BOARD

PROJECT LOCATIONLOCATION MAP (CAMPUS)NOT TO SCALE

ARCHITECT:

HEPNER ARCHITECTS, INCORPORATED

601 SOUTH BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617

MECHANICAL/ELECTRICAL/PLUMBING ENGINEER: ENGINEERING MATRIX, INC . 2860 SCHERER DR N. ST. PETERSBURG, FLORIDA 33716 727-573-4656 CERT AUTH NO. 4288

STATE COLLEGE OF FLORIDALAKEWOOD RANCH, CAMPUSLWR MTSC INTERIOR UPGRADES

SCF PROJECT # 7-19-3-12

78.0

0

78.0

0

A2.1

LIFESAFETY PLANS

A2.1

1 LIFESAFETY PLAN - FIRST FLOORSCALE: 3/32" = 1'-0"

HEPNER ARCHITECTS, INCORPORATED601 S. BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617

DATEDISTRIBUTION

PROJECT NO.

TO THE BEST OF THE ARCHITECT'S KNOWLEDGETHE PLANS AND SPECIFICATIONS ARE COMPLETEAND COMPLY WITH THE FLORIDA BUILDING CODE

COPYRIGHT 2019, HEPNER ARCHITECTS, INCORPORATED. ALL RIGHTS RESERVED

3168

CONSTRUCTION DOCUMENTS 02/04/2019

UPGRADESINTERIORLWR MTSCSCF

7131 PROFESSIONAL PKWY E.SARASOTA , FL 34240

SCF PROJECT # 7-19-3-12

ENGINEERING MATRIX, INC.2860 SCHERER DR N.ST. PETERSBURG, FLORIDA 33716727-473-4656CERT AUTH NO. 4288

PETER M. HEPNER, AIAAR 0010922

LIFE SAFETY LEGEND

PRIMARY EGRESSEXIT WIDTH IN INCHES (MAXIMUM OCCUPANT LOAD FOR EXIT WIDTH)

--"(--)

200 FT TRAVEL DISTANCE TO EXIT,MAXIMUM 200 FT

197'

(E)

(E) (E)

(N)

EXIT LIGHT(E) DENOTES EXISTING. (N) DENOTES NEW

68"(340)F.E.C (E)

F.E.C (E)

F.E.C (E)

NEW STOREFRONTASSEMBLY

REFERENCED STANDARDS· 2017 (6TH EDITION) FLORIDA BUILDING CODE, BUILDING· 2017 (6TH EDITION) FLORIDA BUILDING CODE, PLUMBING· 6TH EDITION FLORIDA FIRE PREVENTION CODE (FFPC) INCLUDING FLORIDA VERSIONS

OF NFPA 1 AND NFPA 101· 2014 STATE REQUIREMENTS FOR EDUCATIONAL FACILITIES (SREF)

EXISTING BUILDING OCCUPANCY TYPE (6 TH EDITION FBC 2017, SECTION 304 AND 311)BUSINESS. UNCHANGED

EXISTING FIRST FLOOR BUILDING AREA = 20,520 SF.EXISTING SECOND FLOOR BUILDING AREA = 20,578 SF

EXISTING BUILDING CONSTRUCTION TYPE (6 TH EDITION FBC 2017, TABLE 601)TYPE II-B , SPRINKLERED, 2-STORY. UNCHANGED(TO BE VERIFIED BY AUTHORITY HAVING JURISDICTION))

MAXIMUM EXIT ACCESS TRAVEL DISTANCE (6 TH EDITION FBC 2017, TABLE 1017.2)BUSINESS OCCUPANCY: 300' ( WITH SPRINKLER SYSTEM) EXISTING: 197' UNCHANGED

OCCUPANT LOAD (UNCHANGED)FIRST FLOOR: 444SECOND FLOOR : 327

CODE COMPLIANCE

200

213

227

215

216 202

229

LIMITS OF CONSTRUCTION

DENOTES AREA NOT IN CONTRACT

(E)

(E)

A2.1

2 LIFESAFETY PLAN - SECOND FLOORSCALE: 3/32" = 1'-0"

68"(340)

68"(340)

F.E.C (E)

F.E.C (E)

95'133A

133B

100

129

147 145

135

134

131

130

(N)

F.E.C (E) FIRE EXTINGUISHER IN CABINET(E) DENOTES EXISTING. (N) DENOTES NEW

NEW SMOKE PARTITION

F.E.(E)F.E.(E)

F.E.C(E)

F.E.C (E)F.E.C (E)

F.E.C (E)

F.E.(E)

F.E.C (E)

F.E.C(E)

F.E.(E)

F.E.C(E)

F.E.(E)

F.E.C (E) FIRE EXTINGUISHER(E) DENOTES EXISTING. (N) DENOTES NEW

S

S

S

S

A4.1DEMOLITION PLANSFIRST FLOOR

A4.1

1 DEMOLITION FLOOR PLAN - FIRST FLOORSCALE: 3/16" = 1'-0"

HEPNER ARCHITECTS, INCORPORATED601 S. BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617

DATEDISTRIBUTION

PROJECT NO.

TO THE BEST OF THE ARCHITECT'S KNOWLEDGETHE PLANS AND SPECIFICATIONS ARE COMPLETEAND COMPLY WITH THE FLORIDA BUILDING CODE

COPYRIGHT 2019, HEPNER ARCHITECTS, INCORPORATED. ALL RIGHTS RESERVED

3168

CONSTRUCTION DOCUMENTS 02/04/2019

UPGRADESINTERIORLWR MTSCSCF

7131 PROFESSIONAL PKWY E.SARASOTA , FL 34240

SCF PROJECT # 7-19-3-12

ENGINEERING MATRIX, INC.2860 SCHERER DR N.ST. PETERSBURG, FLORIDA 33716727-473-4656CERT AUTH NO. 4288

PETER M. HEPNER, AIAAR 0010922

KEY PLANNOT TO SCALE

ROOM 133

A4.1

2 DEMOLITION REFLECTED CEILING PLAN - FIRST FLOORSCALE: 3/16" = 1'-0"

0 4 1020 4 102

DEMOLITION WALL LEGENDEXISTING WALL TO REMAIN

REMOVE EXISTING DOOR AND FRAME

REMOVE EXISTING WINDOW AND FRAME

REMOVE EXISTING WALL

DEMOLITION PLAN GENERAL NOTES

DEMOLITION PLAN SPECIFIC NOTES 1

2

EXISTING INTERIOR PARTITION TO REMAIN, TYP.

3 EXISTING MARKER BOARD TO REMAIN

4 EXISTING PROJECTOR SCREEN TO REMAIN

5 EXISTING LIGHT SWITCH TO BE RE-WORKED, SEE ELECTRICAL

6 REMOVE EXISTING MECHANICAL DEVICE, SAVE FOR RE-USE, SEE MECHANICAL

(E) DENOTES EXISTING FURNITURE OR EQUIPMENT TO REMAIN (TO BEINSTALLED AT SAME LOCATION AFTER NEW FINISHES ARE INSTALLED)

(R)

(RE)

DENOTES EXISTING FURNITURE OR EQUIPMENT TO REMOVED TO BEREPLACED AT NEW LOCATION

DENOTES EXISTING FURNITURE OR EQUIPMENT TO BE REMOVED

LIMITS OF CONSTRUCTION

DENOTES AREA NOT IN CONTRACT

1

3

2 5

EXISTING INTERIOR WINDOW ASSEMBLY TO REMAIN, TYP.

4

(RE)

(RE)

(RE)

(RE)

(RE)

(RE)

(RE)

(RE)

(RE)

(RE)

(RE)

6

7

7 REMOVE EXISTING PROJECTOR AND RETURN TO OWNER. PROVIDE COVER PLATE.PROJECTOR CONNECTIONS TO REMAIN FOR FUTURE POSSIBLE USE. SEE ELECTRICAL

8

8 REMOVE EXISTING VCT FLOOR FINISH AND RUBBER BASE

EXISTING SPEAKER TO REMAIN, TYP. (R) DENOTES RELOCATE

EXISTING LIGHT FIXTURE TO REMAIN

S

EXISTING MECHANICAL DEVICES TO REMAIN

EXISTING LIGHT FIXTURE TO BE REMOVED.(R) DENOTES RELOCATE PER NEW PLANS

EXISTING MECHANICAL DEVICE TO BE REMOVED.(R) DENOTES RELOCATE PER NEW PLANS

1. CONTRACTOR TO COORDINATE WITH OWNER FOR ALL ASBESTOS SURVEY AND ABATEMENT WORKCONDUCTED UNDER SEPARATE CONTRACT. NOT A PART OF THIS CONTRACT.

2. GENERAL CONTRACTOR TO COORDINATE ALL DEMOLITION WITH CONTRACT DOCUMENTS FORNEW CONSTRUCTION

3. REMOVE ALL ABANDONED UTILITIES COMPLETELY.

4. WHERE EXISTING SERVICES SUCH AS PLUMBING, ELECTRICAL, ETC. ARE AFFECTED BYDEMOLITION WORK, SUCH AS REMOVAL OF AN EXISTING PARTITION, THE SERVICES SHALL BEREMOVED TO A POINT WHERE THEY CAN BE CAPPED AND TERMINATED UNLESS OTHERWISEINDICATED ON THE DRAWINGS

5. PATCH AND REPAIR ALL CONSTRUCTION TO REMAIN WHERE AFFECTED BY DEMOLITIONOPERATIONS. CUT AND PATCH EXISTING CONSTRUCTION AS REQUIRED TO INSTALL NEW WORK.

6. PROTECT CONSTRUCTION TO REMAIN FROM WEATHER INTRUSION, VANDALISM, AND ALL OTHERRISKS CREATED BY DEMOLITION OPERATIONS.

7. PROTECT ALL EXISTING FINISHES TO REMAIN FROM DAMAGE FOR DURATION OF NEWCONSTRUCTION.

8. PROTECTION - EXERCISE CARE DURING WORK TO PROTECT INTERIOR AND EXTERIOR EXISTINGCONSTRUCTION. REPAIRS TO EXISTING CONSTRUCTION DUE TO DAMAGE SHALL BE DONE AT NOCOST TO THE OWNER.

9. DISPOSE OF ALL DEMOLISHED MATERIAL OFF SITE, EXCEPT FOR MATERIAL THE OWNER WISHESTO REMAIN. PROVIDE THE OWNER WITH THE OPPORTUNITY TO TAG EXISTING ITEMS THEY WISH TOSAVE.

10. REFER TO PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION

11. ALL CONSTRUCTION IS TO BE SEPARATED FROM OCCUPIED SPACES AND EGRESS COMPONENTS.ALL LIFE SAFETY AND MEP SYSTEMS NEED TO REMAIN FUNCTIONAL IN OCCUPIED SPACES.

12. OWNER WILL REMOVE ALL ARTWORK ON THE WALLS PRIOR TO WORK.

13. CONTRACTOR TO REMOVE AND STORE WALL HUNG ITEMS LIKE DRY ERASE BOARDS, CLOCKS,ETC. PRIOR TO WORK AND RE-INSTALL AT SAME LOCATIONS UPON COMPLETION OF WORK.

TYP, UON

NOTE:· REMOVAL OF FURNITURE BY OWNER· NEW FURNITURE PROVIDED AND INSTALLED BY OWNER· EXISTING FURNITURE INSTALLED AT NEW LOCATIONS BY OWNERCONTRACTOR TO COORDINATE REMOVAL AND REPLACEMENT OF FURNITURE AND OTHER WORKWITH OWNER

10'-0"

11'-9

1/2"

9'-9 1

/2" +

/-

8'-4"+/-

2'-0"

2'-0"

S

S

S

S

7'-2"

V.I.F

.

3'-0" 2'-0" 4'-0"

11'-8 3/4" +/- V.I.F.

9'-6"

V.I.F

.

A5.1NEW PLANSFIRST FLOOR

A5.1

1 NEW FLOOR PLAN SCALE: 3/16" = 1'-0"

HEPNER ARCHITECTS, INCORPORATED601 S. BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617

DATEDISTRIBUTION

PROJECT NO.

TO THE BEST OF THE ARCHITECT'S KNOWLEDGETHE PLANS AND SPECIFICATIONS ARE COMPLETEAND COMPLY WITH THE FLORIDA BUILDING CODE

COPYRIGHT 2019, HEPNER ARCHITECTS, INCORPORATED. ALL RIGHTS RESERVED

3168

CONSTRUCTION DOCUMENTS 02/04/2019

UPGRADESINTERIORLWR MTSCSCF

7131 PROFESSIONAL PKWY E.SARASOTA , FL 34240

SCF PROJECT # 7-19-3-12

ENGINEERING MATRIX, INC.2860 SCHERER DR N.ST. PETERSBURG, FLORIDA 33716727-473-4656CERT AUTH NO. 4288

PETER M. HEPNER, AIAAR 0010922

KEY PLANNOT TO SCALE

ROOM 133

A5.1

2 NEW REFLECTED CEILING PLAN SCALE: 3/16" = 1'-0"

0 4 1020 4 102

NEW PLAN LEGENDEXISTING WALL TO REMAIN

NEW WALL AND DOOR ASSEMBLY

NEW PLAN GENERAL NOTES

NEW PLAN SPECIFIC NOTES

· (1)2' WIDE FULL LIGHT PANEL NEXT TO DOOR.· REST OF THE WALL LENGTH: SOLID PANELS, 4' WIDE MODULE STARTING

FROM DOOR SIDE.· FILLER PANEL AT WALL ENDPROVIDE SHOP DRAWINGS FOR OWNER'S REVIEW

6

7

8

9

EXISTING MECHANICAL DEVICES TO REMAIN, TYP UNO

1

2

3

4

NEW DIFFUSER

5

EXISTING CEILING GRID AND TILE TO REMAIN, TYP.

EXISTING LIGHT FIXTURES TO REMAIN, TYP.

EXISTING WINDOW TO REMAIN, TYP.

EXISTING PROJECTOR SCREEN TO REMAIN

RELOCATE RETURN DEVICE

LIMITS OF CONSTRUCTION

EXISTING ACOUSTICAL CEILING TILE ANDGRID TO REMAIN, TYP.

EXISTING SPEAKER TO REMAIN, TYP.

EXISTING LIGHT FIXTURE TO REMAIN

NEW CARPET, SEE FINISH SCHEDULE

S

EXISTING SPRINKLER TO REMAIN, TYP.

EXISTING MECHANICAL DEVICESTO REMAIN

NEW OR RELOCATED MECHANICALDEVICES

DENOTES AREA NOT IN CONTRACT

6

7

4

5

3

9

8

7

10

B

A

BASE CEILINGWALLS

FINISH LEGEND

CEILING HEIGHT

ROOM NAME

ROOM NUMBER

CEILING FINISHWALL FINISHBASE FINISHFLOOR FINISH

RECEPTIONB,C/B/C/C9'-0"

101

ROOM LEGEND

C

FLOOR

CARPET: CP2

CARPET: CP1

EXISTING TOREMAIN

EXISTING TOREMAIN

NEW CEILING TILES(EXISTING CEILING GRID):

C1

PAINTEXISTING GYP BD FINISH.

P1 AND P2

SEE FINISH SCHEDULE, SEE A-61

--

-

-

RUBBERB1

8'-0"133 VESTIBULE

A/A/A/C

8'-0"133A OFFICE

A/A/A/C

8'-0"133B OFFICE

A/A/A/C

EXISTING TOREMAIN

10 LOCATION OF NEW LIGHT SWITCH

10

10

3

2

1

2 OFFICE CHAIR

3 VISITOR'S CHAIR

4 MEETING TABLE

FURNITURE LEGEND

1. FIELD VERIFY ALL DIMENSIONS ASSOCIATED WITH EXISTING CONSTRUCTION.

2. ALTERED SURFACES WITHIN CONSTRUCTION LIMITS SHALL BE PATCHED AND REPAIRED TOCONDITION THAT MATCHES THE EXISTING ADJACENT CONSTRUCTION.

3. PATCH ANY EXISTING CONSTRUCTION AS REQUIRED WHICH IS DAMAGED DUE TO THEINSTALLATION OF NEW FIXTURES, ELECTRICAL DEVICES, EQUIPMENT, OR ANY OTHER NEWCOMPONENT.

4. CONTRACTOR SHALL CHECK EXISTING FLOOR SLABS FOR LEVEL AFTER COMPLETION OFDEMOLITION WORK AND NOTIFY THE ARCHITECT OF ANY DEVIATION FROM SPECIFIEDTOLERANCES. CORRECTIVE WORK SHALL BE ACCOMPLISHED PRIOR TO INSTATING NEWCONSTRUCTION.

5. ITEMS LOCATED IN ACOUSTICAL CEILINGS ARE CENTERED IN CEILING PANELS OR AS NOTED.

1

1

1 OFFICE SYSTEM FURNITURE GROUP-A

2

3

3

4

TYP.

TYP.

5 LOUNGE CHAIR (EXISTING)

6 LARGE TABLE

7 STUDENT CHAIR

133

133A

133B

147

145

129

134

ROOM LEGEND SPACE SPACE NAME

100 LOBBY129 RECWPTION132 CONFERENCE

133 VESTIBULE133A OFFICE133B OFFICE

134 OFFICE135 OFFICE147 BREAK ROOM

(E)

(N)

NEW EXIT SIGN(E) DENOTES EXISTING, (N) DENOTES NEW

P2: PAINT (ACCENT)MFTR: BENJAMIN MOORE, ULTRA SPEC 500COLOR:SEE TABLE BELOWFINISH: INTERIOR SEMIGLOSSCOATS: (1) PRIMER, (2) FINISH COATS

P-A: COLOR MATCH SW 6524 COMMODOREP-B: COLOR MATCH SW 6487 CLOUDBURSTP-C: COLOR MATCH SW 6437 HAVENP-D: COLOR MATCH SW 6946 SURFERP-E: COLOR MATCH SW 7018 DOVETAILP-F: COLOR MATCH SW 6712 LUAU

P3: PAINT DOOR FRAMESMFTR: BENJAMIN MOORE,ADVANCE WATERBORNE INTERIOR EXTERIORALKYDCOLOR:COLOR MATCH SW7018 DOVETAILFINISH: INTERIOR SEMIGLOSSCOATS: (1) PRIMER, (2) FINISH COATSPAINT ALL WOOD FRAMES, HM FRAMES

CP1: CARPET TILEMFTR: SHAW CONTRACT GROUPCOLLECTION: NO RULESSTYLE: SPECTRUM TILE 59584 SIZE: 24X24BACKING: GLASBAC BACKING, ADHESIVELYATTACHED WITH TACTILE.COLOR: CHAMELEON 83405.INSTALLATION PATTERN: ASHLAR

(ALL INTERIOR FINISHES TO BE CLASS A , TYPICAL)FINISH SCHEDULE

P-C

P-C

B1: VINYL WALL BASEMFTR: JOHNSONITECOLOR/FINISH: 32 PEBBLE WGPROVIDE COORDINATING TRANSITIONACCESSORIES.

P1: PAINT (TYPICAL THROUGHOUT U.N.O.)MFTR: BENJAMIN MOORE, ULTRA SPEC 500COLOR: COLOR MATCH SW 7065 ARGOSFINISH: INTERIOR SEMIGLOSSCOATS: (1) PRIMER, (2) FINISH COATS

NEW DE-MOUNTABLE PARTITION ASSEMBLY. SEE 3/A5.1"TRENDWALL" SYSTEM BY TRENDWAY. https://www.trendway.com/product/trendwall/CONTACT: EDURADO CHAVES, EMAIL: echaves@trendway.com , PHONE: 954-551-1029 FURNITURE PROVIDED AND INSTALLED BY OWNER

5A EXISTING MARKER BOARD TO REMAIN

A5.1

3 DE-MOUNTABLE WALLSCALE: 3/8" = 1'-0" NOTE:

1. ELEVATION OF WALL ON SOUTH OF 133A SIMILAR. PROVIDE(1) 2'-0" WIDE SIDE LIGHT PANEL, (3) 4'-0" SOLID PANELS, AND (1)INFILL PANEL

2. PROVIDE ALL DETAILS PER MANUFACTURER'S STANDARDS3. VINYL COLOR FOR DOOR: RUSSIAN MAPLE AS34. VINYL COLOR ON SOLID PANELS: TEXTURED LIGHT GRAY V515. PAINT COLOR ON TRIM PIECES: LIGHT GRAY-L

3A5.1

INFILL PANEL, TYP.

SOLID PANEL, TYP.

GLAZED PANEL(SIDE LIGHT) PANEL,TYP.

FLUSH DOORTO M

ATCH

EXI

ST D

OOR

8'-10

"1'-

8"

7'-0"

28'-6" +/-

11'-6

"

3'-5 1/2" 6'-0"

10'-6

"

1'-4 3/4"+/- 3'-8" 3'-8" 3'-8" 3'-8" 1'-5 3/4"+/- 2" TYP U.N.O.

4 1/4"

A5.2NEW PLANSSECOND FLOOR

A5.2

1 NEW FLOOR PLAN - SECOND DLOORSCALE: 3/16" = 1'-0"

HEPNER ARCHITECTS, INCORPORATED601 S. BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617

DATEDISTRIBUTION

PROJECT NO.

TO THE BEST OF THE ARCHITECT'S KNOWLEDGETHE PLANS AND SPECIFICATIONS ARE COMPLETEAND COMPLY WITH THE FLORIDA BUILDING CODE

COPYRIGHT 2019, HEPNER ARCHITECTS, INCORPORATED. ALL RIGHTS RESERVED

3168

CONSTRUCTION DOCUMENTS 02/04/2019

UPGRADESINTERIORLWR MTSCSCF

7131 PROFESSIONAL PKWY E.SARASOTA , FL 34240

SCF PROJECT # 7-19-3-12

ENGINEERING MATRIX, INC.2860 SCHERER DR N.ST. PETERSBURG, FLORIDA 33716727-473-4656CERT AUTH NO. 4288

PETER M. HEPNER, AIAAR 0010922

NEW PLAN LEGENDEXISTING WALL TO REMAIN

NEW WALL AND DOOR ASSEMBLY

GENERAL NOTES

2

NEW PLAN SPECIFIC NOTES

NEW STOREFRONT ASSEMBLY TO MATCH EXISTING AT EXISTING SIMULATION SUITE .SEE 3/A5.2

6

10

7

8

9

EXISTING MECHANICAL DEVICES TO REMAIN, TYP.

1

2

3

EXISTING SOFFIT TO REMAIN, TYP.

4

PROVIDE METAL STUD FRAMING AND GYP BD FINISH AT HEAD OF NEW WALLASSEMBLY, SEE DETAIL 4/A5.2

5

EXISTING CEILING GRID AND TILE TO REMAIN, TYP.

EXISTING LIGHT FIXTURES TO REMAIN, TYP.

KEY PLANNOT TO SCALE

AREA OF WORK

A5.2

2 NEW REFLECTED CEILING PLAN - SECOND FLOORSCALE: 3/16" = 1'-0"

0 4 1020 4 102

EXISTING WALL TO REMAIN, TYP.

LINE OF EXISTING SOFFIT RETURN

A5.2

3 ELEVATIONSCALE: 3/8" = 1'-0"

5

EXISTING SOFFIT

EXISTING WALL

NEW ALUM STOREFRONT ASSEMBLY (FRAME TYPE A)

3A5.2

1

3

4

5 810

10'-6" AFFEXIST.

NEW LOCATION FOR EXISTING SIGN-IN KIOSK

9

LIMITS OF CONSTRUCTION

DENOTES AREA NOT IN CONTRACT

EXISTING ACOUSTICAL CEILING TILE AND GRID TO REMAIN

NEW EXIT SIGN

EXISTING LIGHT FIXTURE TOREMAIN

LINE OF EXISTINGACOUSTICALCEILINGBEYOND

EXISTING FLOOR FINISH TO REMAIN, TYP.

7

EXIS

TING

EXIS

TING

EXISTING DOOR TOREMAIN

0 2 51

10

11

11 NEW LCD MONITOR PROVIDED AND INSTALLED BY OWNER

NEW 3 5/8" METAL STUDS @16" O.C.MAX. SECURE TO EXISTING STUDS.BRACE TO STRUCTURE AS REQUIRED

A5.2

4 DETAILSCALE: 3/8" = 1'-0"

EXISTING SOFFIT ANDRETURN TO REMAIN

EXISTING SOFFIT RETURNBEYOND TO REMAIN

0 8" 1'-4"4" 1'-0"

4A5.2

12

NEW EXIT SIGN12

DOOR TYPE 1 WITH EXIT HARDWAREALIGN WITH EXISTING DOOR BEYOND

7

11'-6" AFFACOUSTICALCEILING

NEW ALUMSTOREFRONT SYSTEM

EXISTINGWING WALL

NEW PAINTEDGYP BD.BULKHEADSEE DETAIL4/A5.2

EXISTING METAL FRAMING TODECK. VERIFY IN FIELD

NEW 5/8" GYP BD FINISH ON AT NEWBULKHEAD. NEW PAINT FINISH ONBOTH SIDES, TYP.

'J' BEAD AND SEALANT

TRIM EXISTING GRID AND TILEFOR NEW BULKHEAD. PROVIDENEW CEILING GRID ANGLE ANDSEALANT

LINE OF EXISTING WING WALLBEYOND TO REMAIN

NEW STOREFRONT ASSEMBLY

SHIM, BACKER ROD, AND SEALANT8'-10" AFFTO MATCH EXISTINGSTOREFRONT

PROVIDE EACH PR DOOR(S) WITH THE FOLLOWING:

QTY DESCRIPTION CATALOG NUMBER FINISH MFR6EA HINGE 4.5"X4.5" BUTT H2303 US23D YKK2EA PUSH-PULL SET 1113 628 CLR YKK1EA PANIC HARDWARE 1492 US28D FALCON1EA PANIC HARDWARE 1490 US28D FALCON2EA SURFACE CLOSER 8100 NORTON CLEAR NORTON

HARDWARE SET 1

WORKPOINTWORKPOINT

NEW ALUMSTOREFRONTENTRY SYSTEM,SEE DOORSCHEDULE

SEE A4.1 AND A5.1 FOR DEMOLITION AND NEW PLAN GENERAL NOTES

6

8

5

56

7TYP.

FURNITURE LEGENDSEE A5.1 FOR FURNITURE LEGEND

EXIST.215 SIMULATION LAB

NO WORK

200EXIST

216 SIMULATION # 1NO WORK

9'-0"213 SOUTH CORRIDOR

C/C/C/C

9'-0"200 STUDENTS ROOM

EXISTING TO REMAIN

EXIST227 SIMULATION # 8

NO WORK

EXIST229 MEN'S

NO WORK

213

227215

216

229

202

200

DOOR, FRAME AND HARDWARE SCHEDULENO.

FRAMESTYPE

LOCATION DOORSTYPE DOOR OPENINGS

WIDTH HEIGHTMATERIAL MATERIALFROM TO

HDW SETFIRE

200 ALUM PR 3'-0"ROOM 200 CORR 213 - 1A ALUM 7'-0"V.I.F.

1

·······

HEPNER ARCHITECTS, INCORPORATED601 S. BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617 | IB 26001337

DATEDISTRIBUTION

PROJECT NO.

TO THE BEST OF THE ARCHITECT'S KNOWLEDGETHE PLANS AND SPECIFICATIONS ARE COMPLETEAND COMPLY WITH THE FLORIDA BUILDING CODE

COPYRIGHT 2019, HEPNER ARCHITECTS, INCORPORATED. ALL RIGHTS RESERVED

3168

UPGRADESINTERIORLWR MTSCSCF

7131 PROFESSIONAL PKWY E.SARASOTA , FL 34240

SCF PROJECT # 7-19-3-12

ENGINEERING MATRIX, INC.2860 SCHERER DR N.ST. PETERSBURG, FLORIDA 33716727-473-4656CERT AUTH NO. 4288

© 2019 Engineering Matrix, Inc.

CONSTRUCTION DOCUMENTS 02/04/2019

M0.0GENERALMECHANICAL

ROOM 133

133133A

133B

147

145

129

134

HEPNER ARCHITECTS, INCORPORATED601 S. BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617 | IB 26001337

DATEDISTRIBUTION

PROJECT NO.

TO THE BEST OF THE ARCHITECT'S KNOWLEDGETHE PLANS AND SPECIFICATIONS ARE COMPLETEAND COMPLY WITH THE FLORIDA BUILDING CODE

COPYRIGHT 2019, HEPNER ARCHITECTS, INCORPORATED. ALL RIGHTS RESERVED

3168

UPGRADESINTERIORLWR MTSCSCF

7131 PROFESSIONAL PKWY E.SARASOTA , FL 34240

SCF PROJECT # 7-19-3-12

ENGINEERING MATRIX, INC.2860 SCHERER DR N.ST. PETERSBURG, FLORIDA 33716727-473-4656CERT AUTH NO. 4288

© 2019 Engineering Matrix, Inc.

CONSTRUCTION DOCUMENTS 02/04/2019

KEY PLANNOT TO SCALE

M2.1

1 DEMOLITION FIRST FLOOR PLAN SCALE: 3/16" = 1'-0"

0 4 102

M2.1

2 NEW FIRST FLOOR PLAN SCALE: 3/16" = 1'-0"

0 4 102

M2.1PLANSFIRST FLOOR

MECHANICAL

ROOM LEGEND SPACE SPACE NAME

100 LOBBY129 RECEPTION132 CONFERENCE

133 VESTIBULE133A OFFICE133B OFFICE

134 OFFICE135 OFFICE147 BREAK ROOM

HEPNER ARCHITECTS, INCORPORATED601 S. BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617 | IB 26001337

DATEDISTRIBUTION

PROJECT NO.

TO THE BEST OF THE ARCHITECT'S KNOWLEDGETHE PLANS AND SPECIFICATIONS ARE COMPLETEAND COMPLY WITH THE FLORIDA BUILDING CODE

COPYRIGHT 2019, HEPNER ARCHITECTS, INCORPORATED. ALL RIGHTS RESERVED

3168

UPGRADESINTERIORLWR MTSCSCF

7131 PROFESSIONAL PKWY E.SARASOTA , FL 34240

SCF PROJECT # 7-19-3-12

ENGINEERING MATRIX, INC.2860 SCHERER DR N.ST. PETERSBURG, FLORIDA 33716727-473-4656CERT AUTH NO. 4288

© 2019 Engineering Matrix, Inc.

CONSTRUCTION DOCUMENTS 02/04/2019

E0.0SHEETGENERALELECTRICAL

ROOM 133

133

133A

133B

147

145

129

134

HEPNER ARCHITECTS, INCORPORATED601 S. BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617 | IB 26001337

DATEDISTRIBUTION

PROJECT NO.

TO THE BEST OF THE ARCHITECT'S KNOWLEDGETHE PLANS AND SPECIFICATIONS ARE COMPLETEAND COMPLY WITH THE FLORIDA BUILDING CODE

COPYRIGHT 2019, HEPNER ARCHITECTS, INCORPORATED. ALL RIGHTS RESERVED

3168

UPGRADESINTERIORLWR MTSCSCF

7131 PROFESSIONAL PKWY E.SARASOTA , FL 34240

SCF PROJECT # 7-19-3-12

ENGINEERING MATRIX, INC.2860 SCHERER DR N.ST. PETERSBURG, FLORIDA 33716727-473-4656CERT AUTH NO. 4288

© 2019 Engineering Matrix, Inc.

CONSTRUCTION DOCUMENTS 02/04/2019

KEY PLANNOT TO SCALE

E2.1

1 DEMOLITION FIRST FLOOR PLAN - LIGHTINGSCALE: 3/16" = 1'-0"

0 4 102

E2.1

2 NEW FIRST FLOOR PLAN - LIGHTINGSCALE: 3/16" = 1'-0"

0 4 102

E2.1PLANS LIGHTINGFIRST FLOOR

ROOM LEGEND SPACE SPACE NAME

100 LOBBY129 RECEPTION132 CONFERENCE

133 VESTIBULE133A OFFICE133B OFFICE

134 OFFICE135 OFFICE147 BREAK ROOM

200

213

227215

216

229

202

200

213

227215

216

229

AREA OF WORK

HEPNER ARCHITECTS, INCORPORATED601 S. BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617 | IB 26001337

DATEDISTRIBUTION

PROJECT NO.

TO THE BEST OF THE ARCHITECT'S KNOWLEDGETHE PLANS AND SPECIFICATIONS ARE COMPLETEAND COMPLY WITH THE FLORIDA BUILDING CODE

COPYRIGHT 2019, HEPNER ARCHITECTS, INCORPORATED. ALL RIGHTS RESERVED

3168

UPGRADESINTERIORLWR MTSCSCF

7131 PROFESSIONAL PKWY E.SARASOTA , FL 34240

SCF PROJECT # 7-19-3-12

ENGINEERING MATRIX, INC.2860 SCHERER DR N.ST. PETERSBURG, FLORIDA 33716727-473-4656CERT AUTH NO. 4288

© 2019 Engineering Matrix, Inc.

CONSTRUCTION DOCUMENTS 02/04/2019

KEY PLANNOT TO SCALE E2.2

FLOOR PLANSSECOND

LIGHTING

E2.2

1 DEMOLITION SECOND FLOOR PLAN - LIGHTINGSCALE: 3/16" = 1'-0"

0 4 102

E2.2

2 NEW SECOND FLOOR PLAN - LIGHTINGSCALE: 3/16" = 1'-0"

0 4 102

ROOM LEGEND SPACE SPACE NAME

200 STUDENTS ROOM213 SOUTH CORRIDOR215 SIMULATION LAB

227 SIMULATION #8229 MEN'S

ROOM 133

IDF ROOM,FACPLOCATION,& MAINELECTRICAL

133133A

133B

147

145

129

134

HEPNER ARCHITECTS, INCORPORATED601 S. BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617 | IB 26001337

DATEDISTRIBUTION

PROJECT NO.

TO THE BEST OF THE ARCHITECT'S KNOWLEDGETHE PLANS AND SPECIFICATIONS ARE COMPLETEAND COMPLY WITH THE FLORIDA BUILDING CODE

COPYRIGHT 2019, HEPNER ARCHITECTS, INCORPORATED. ALL RIGHTS RESERVED

3168

UPGRADESINTERIORLWR MTSCSCF

7131 PROFESSIONAL PKWY E.SARASOTA , FL 34240

SCF PROJECT # 7-19-3-12

ENGINEERING MATRIX, INC.2860 SCHERER DR N.ST. PETERSBURG, FLORIDA 33716727-473-4656CERT AUTH NO. 4288

© 2019 Engineering Matrix, Inc.

CONSTRUCTION DOCUMENTS 02/04/2019

KEY PLANNOT TO SCALE

E3.1

1 DEMOLITION FIRST FLOOR PLAN - ELECTRICALSCALE: 3/16" = 1'-0"

0 4 102

E3.1

2 NEW FIRST FLOOR PLAN - ELECTRICALSCALE: 3/16" = 1'-0"

0 4 102

E3.1PLANS - FIRST FLOOR

ELECTRICAL

ROOM LEGEND SPACE SPACE NAME

100 LOBBY129 RECEPTION132 CONFERENCE

133 VESTIBULE133A OFFICE133B OFFICE

134 OFFICE135 OFFICE147 BREAK ROOM

200

213

227215

216

229

202

200

213

227215

216

229

AREA OF WORK

IDF ROOMAND FATCLOCATION

SECONDFLOORELECTRICALROOM

HEPNER ARCHITECTS, INCORPORATED601 S. BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617 | IB 26001337

DATEDISTRIBUTION

PROJECT NO.

TO THE BEST OF THE ARCHITECT'S KNOWLEDGETHE PLANS AND SPECIFICATIONS ARE COMPLETEAND COMPLY WITH THE FLORIDA BUILDING CODE

COPYRIGHT 2019, HEPNER ARCHITECTS, INCORPORATED. ALL RIGHTS RESERVED

3168

UPGRADESINTERIORLWR MTSCSCF

7131 PROFESSIONAL PKWY E.SARASOTA , FL 34240

SCF PROJECT # 7-19-3-12

ENGINEERING MATRIX, INC.2860 SCHERER DR N.ST. PETERSBURG, FLORIDA 33716727-473-4656CERT AUTH NO. 4288

© 2019 Engineering Matrix, Inc.

CONSTRUCTION DOCUMENTS 02/04/2019

KEY PLANNOT TO SCALE E3.2

FLOOR PLANSSECOND

ELECTRICAL

E3.2

1 DEMOLITION SECOND FLOOR PLAN - ELECTRICALSCALE: 3/16" = 1'-0"

0 4 102

E3.2

2 NEW SECOND FLOOR PLAN - ELECTRICALSCALE: 3/16" = 1'-0"

0 4 102

ROOM LEGEND SPACE SPACE NAME

200 STUDENTS ROOM213 SOUTH CORRIDOR215 SIMULATION LAB

227 SIMULATION #8229 MEN'S

top related