A0.0 COVER SHEET HEPNER ARCHITECTS, INCORPORATED 601 S. BOULEVARD, SUITE 101 TAMPA, FLORIDA 33606 813-229-0614 AA 0002617 DATE DISTRIBUTION PROJECT NO. TO THE BEST OF THE ARCHITECT'S KNOWLEDGE THE PLANS AND SPECIFICATIONS ARE COMPLETE AND COMPLY WITH THE FLORIDA BUILDING CODE COPYRIGHT 2019, HEPNER ARCHITECTS, INCORPORATED. ALL RIGHTS RESERVED 3168 CONSTRUCTION DOCUMENTS 02/04/2019 UPGRADES INTERIOR LWR MTSC SCF 7131 PROFESSIONAL PKWY E. SARASOTA , FL 34240 SCF PROJECT # 7-19-3-12 ENGINEERING MATRIX, INC. 2860 SCHERER DR N. ST. PETERSBURG, FLORIDA 33716 727-473-4656 CERT AUTH NO. 4288 PETER M. HEPNER, AIA AR 0010922 PROJECT LOCATION LOCATION MAP (LOCAL) NOT TO SCALE INDEX DRAWING SYMBOL AND IDENTIFICATION LEGEND ARCHITECTURAL ABBREVIATIONS & AND L ANGLE @ AT x BY C CENTER LINE - NONE REQUIRED P PLATE A/C AIR CONDITION (-ER) (-ING) AB ANCHOR BOLT AC P ACOUSTICAL PANEL CEILING AC T ACOUSTICAL TILE AC W ACOUSTICAL WALL SYSTEM ADJ ADJUSTABLE AFF ABOVE FINISHED FLOOR ALM ALUMINUM ALT ALTERNATE APPROX APPROXIMATELY BLDG BUILDING BLKG BLOCKING BM BEAM BRK BRICK BUR BUILT-UP ROOFING CB CATCH BASIN CEM PLS CEMENT PLASTER (PORTLAND) CHKBD CHALKBOARD CLG CEILING CLO CLOSET CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONF CONFERENCE CONST CONSTRUCTION CONT CONTINUOUS CORR CORRIDOR CPT CARPET CR CLASSROOM CT CERAMIC MOSAIC TILE CTRJT CONTROL JOINT CUS CUSTODIAN'S UTILITY SHELF D DEEP, DEPTH DBL DOUBLE DF DRINKING FOUNTAIN DIA, Ø DIAMETER DIM DIMENSION DN DOWN DNSP DOWNSPOUT DP DAMPPROOFING DR DOOR DTL DETAIL DWG DRAWING EA EACH ELEC ELECTRICAL EL ELEVATION ELEV ELEVATOR ENCL ENCLOSURE EQ EQUAL EQUIP EQUIPMENT ETC ET CETERA EWC ELECTRICAL WATER COOLER EXIST EXISTING EXP JT EXPANSION JOINT EXT EXTERIOR FD FLOOR DRAIN FE FIRE EXTINGUISHER FEC FIRE EXTINGUISHER CABINET FH FIRE HYDRANT FHC FIRE HOSE CABINET FIN FINISH FL FLOOR FLDR FOLDING DOOR FRTW FIRE RETARDANT TREATED WOOD FSS FOLDING SHOWER SEAT FT FEET FTG FOOTING GA GAUGE GALV GALVANIZED GB GRAB BAR GC GENERAL CONTRACTOR GCT GLAZED CERAMIC MOSAIC GL GLASS, GLAZING GT GLAZED WALL TILE GWC GLAZED WALL COATING GYP BD GYPSUM BOARD GYPLS GYPSUM PLASTER H HEIGHT, HIGH HC HOLLOW CORE HD HAND DRYER HDW HARDWARE HM HOLLOW METAL HNRL HANDRAIL HORIZ HORIZONTAL(LY) HR HOUR ID INSIDE DIAMETER INSUL INSULATION INT INTERIOR INV INVERT JAN JANITOR JT JOINT LA LANGUAGE ARTS LAM LAMINATED LAV LAVATORY LLH LONG LEG HORIZONTAL LMC LINEAR METAL CEILING LW LIGHTWEIGHT M MIRROR M/S MIRROR/SHELF MAINT MAINTENANCE MAT'L MATERIAL MAX MAXIMUM MECH MECHANICAL MFR MANUFACTURER MH MANHOLE MIN MINIMUM MN MINUTE MO MASONRY OPENING MPU MULTI-PURPOSE UNIT MTD MOUNTED MTL METAL NIC NOT IN CONTRACT NO.,# NUMBER NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER OPNG OPENING OPP OPPOSITE PART'N PARTITION PF RF PREFORMED ROOFING PLBG PLUMBING PLS PLASTER PNT PAINT (PAINTED FINISH) PROJ PROJECT PT PRESSURE TREATED PTD PAPER TOWEL DISPENSER PTD/WR PAPER TOWEL DISPENSER /WASTE RECEPTACLE PWD PLYWOOD QT QUARRY TILE R RADIUS R/W RIGHT-OF-WAY RCP REINFORCED CONCRETE PIPE RD ROOF DRAIN REBAR REINFORCING BAR RECT RECTANGULAR REINF REINFORCEMENT REQ'D REQUIRED RES F RESINOUS FLOORING REV REVERSE RFG REFRIGERATOR RH ROBE HOOK RM ROOM RP RT RAISED PROFILE RUBBER TILE RT RUBBER TILE S/H SEALER/HARDENER SC SOLID CORE SCI SCIENCE SCR SHOWER CURTAIN/ROD SD SOAP DISPENSER SFT GL SAFETY GLASS SH SOAP HOLDER SHO SHOWER SHO C SHOWER CONTROLS SHO H SHOWER HEAD SIM SIMILAR SND SANITARY NAPKIN DISPOSAL SNV SANITARY NAPKIN VENDOR SNV/D SANITARY NAPKIN VENDOR/DISPOSAL SP C SPECIAL COATING SPECS SPECIFICATIONS SQ SQUARE SS STAINLESS STEEL STC SOUND TRANSMISSION CLASS (RATING) STD STANDARD STL STEEL STOR STORAGE STR STRUCTURAL SUPPL SUPPLEMENTARY SUS SUSPENDED SW SWITCH T TOILET T&G TONGUE AND GROOVE TB TOWEL BAR THR THRESHOLD TKBD TACKBOARD TMP TEMPERED TPO TEACHER PLANNING OFFICE TTD TOILET TISSUE DISPENSER TYP TYPICAL, (UNLESS OTHERWISE NOTED) U URINAL UON/ UNO UNLESS OTHERWISE NOTED V VINYL VCT VINYL COMPOSITION TILE VERT VERTICAL VEST VESTIBULE VSF VINYL SHEET FLOORING VT VINYL TILE W/ WITH WC WALL COVERING WD WOOD WR WASTE RECEPTACLE WWF WELDED WIRE FABRIC OH OPPOSITE HAND MRKBD MARKERBOARD DETAIL SYMBOL EXTERIOR ELEVATION SYMBOL SECTION SYMBOL NORTH ARROW VERTICAL ELEVATION MARK INTERIOR ELEVATION SYMBOL DETAIL NUMBER DRAWING NUMBER SIGNAGE TYPE SPECIFICATION SECTION 101423 DETAIL INDICATION DETAIL NUMBER DRAWING NUMBER DETAIL NUMBER DRAWING NUMBER DETAIL NUMBER DRAWING NUMBER DETAIL NUMBER DRAWING NUMBER SECTION "CUT LINE" DETAIL AREA INDICATES ELEVATION TO BE VIEWED INDICATES ELEVATION TO BE VIEWED CENTERLINE OF REFERENCE GRID COLUMN LINE SYMBOL DOOR SYMBOL DOOR NUMBER DOOR TYPE / FRAME TYPE WINDOW TYPE / STOREFRONT TYPE / LOUVER TYPE FLOOR FINISH TYPE INSTRUCTIONAL AIDS TYPE TOILET ACCESSORY TYPE GLAZING TYPE KITCHEN EQUIPMENT TYPE EQUIPMENT NUMBER ROOM NUMBER IDENTIFICATION NOTE NUMBER SPECIFIC NOTE INDICATION 1 A11.1 1 A9.1 1 A10.1 1 13.1 1 A11.1 100A.1 1 102 D FT# 1 A A 1 23 1 LIFE SAFETY OCCUPANT CAPACITY +100'-0" SPOT ELEVATION # WALL TYPE 1 800 40 20 GENERAL A0.0 INDEX/SYMBOL AND IDENTIFICATION LEGEND ARCHITECTURAL A2.1 LIFE SAFETY PLANS A4.1 DEMOLITION PLAN - FIRST FLOOR A5.1 NEW FLOOR PLAN - FIRST FLOOR A5.2 NEW FLOOR PLAN - SECOND FLOOR MECHANICAL M0.0 MECHANICAL GENERAL M2.1 FIRST FLOOR PLANS MECHANICAL ELECTRICAL E0.0 ELECTRICAL GENERAL SHEET E2.1 FIRST FLOOR PLANS - LIGHTING E2.2 SECOND FLOOR PLANS - LIGHTING E3.1 FIRST FLOOR PLANS - ELECTRICAL E3.2 SECOND FLOOR PLANS - ELECTRICAL NOTE: WHEN PLURAL OF A TERM IS INTENDED, THE SUFFIX "S" WILL BE ADDED TO ITS ABBREVIATION. F.O. FACE OF GWB GYPSUM BOARD PROJECT LOCATION LOCATION MAP (CAMPUS) NOT TO SCALE ARCHITECT: HEPNER ARCHITECTS, INCORPORATED 601 SOUTH BOULEVARD, SUITE 101 TAMPA, FLORIDA 33606 813-229-0614 AA 0002617 MECHANICAL/ELECTRICAL/PLUMBING ENGINEER: ENGINEERING MATRIX, INC . 2860 SCHERER DR N. ST. PETERSBURG, FLORIDA 33716 727-573-4656 CERT AUTH NO. 4288 STATE COLLEGE OF FLORIDA LAKEWOOD RANCH, CAMPUS LWR MTSC INTERIOR UPGRADES SCF PROJECT # 7-19-3-12
12
Embed
STATE COLLEGE OF FLORIDA LWR... · 78.00 78.00 a2.1 lifesafety plans a2.1 1 lifesafety plan - first floor scale: 3/32" = 1'-0" hepner architects, incorporated 601 s. boulevard, suite
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
A0.0
COVER SHEET
HEPNER ARCHITECTS, INCORPORATED601 S. BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617
DATEDISTRIBUTION
PROJECT NO.
TO THE BEST OF THE ARCHITECT'S KNOWLEDGETHE PLANS AND SPECIFICATIONS ARE COMPLETEAND COMPLY WITH THE FLORIDA BUILDING CODE
COPYRIGHT 2019, HEPNER ARCHITECTS, INCORPORATED. ALL RIGHTS RESERVED
& ANDL ANGLE@ ATx BYC CENTER LINE- NONE REQUIREDP PLATE
A/C AIR CONDITION (-ER) (-ING)AB ANCHOR BOLTAC P ACOUSTICAL PANEL CEILINGAC T ACOUSTICAL TILEAC W ACOUSTICAL WALL SYSTEMADJ ADJUSTABLEAFF ABOVE FINISHED FLOORALM ALUMINUMALT ALTERNATEAPPROX APPROXIMATELY
EA EACHELEC ELECTRICALEL ELEVATIONELEV ELEVATORENCL ENCLOSUREEQ EQUALEQUIP EQUIPMENTETC ET CETERAEWC ELECTRICAL WATER COOLEREXIST EXISTINGEXP JT EXPANSION JOINTEXT EXTERIOR
FD FLOOR DRAINFE FIRE EXTINGUISHERFEC FIRE EXTINGUISHER CABINETFH FIRE HYDRANTFHC FIRE HOSE CABINETFIN FINISHFL FLOORFLDR FOLDING DOOR
FRTW FIRE RETARDANT TREATED WOODFSS FOLDING SHOWER SEATFT FEETFTG FOOTING
GA GAUGEGALV GALVANIZEDGB GRAB BARGC GENERAL CONTRACTORGCT GLAZED CERAMIC MOSAICGL GLASS, GLAZINGGT GLAZED WALL TILE
GENERALA0.0 INDEX/SYMBOL AND IDENTIFICATION LEGEND
ARCHITECTURALA2.1 LIFE SAFETY PLANSA4.1 DEMOLITION PLAN - FIRST FLOORA5.1 NEW FLOOR PLAN - FIRST FLOORA5.2 NEW FLOOR PLAN - SECOND FLOOR
MECHANICALM0.0 MECHANICAL GENERALM2.1 FIRST FLOOR PLANS MECHANICAL
ELECTRICALE0.0 ELECTRICAL GENERAL SHEETE2.1 FIRST FLOOR PLANS - LIGHTINGE2.2 SECOND FLOOR PLANS - LIGHTINGE3.1 FIRST FLOOR PLANS - ELECTRICALE3.2 SECOND FLOOR PLANS - ELECTRICAL
NOTE: WHEN PLURAL OF A TERM IS INTENDED, THE SUFFIX "S" WILL BE ADDED TO ITS ABBREVIATION.
F.O. FACE OF
GWB GYPSUM BOARD
PROJECT LOCATIONLOCATION MAP (CAMPUS)NOT TO SCALE
ARCHITECT:
HEPNER ARCHITECTS, INCORPORATED
601 SOUTH BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617
MECHANICAL/ELECTRICAL/PLUMBING ENGINEER: ENGINEERING MATRIX, INC . 2860 SCHERER DR N. ST. PETERSBURG, FLORIDA 33716 727-573-4656 CERT AUTH NO. 4288
STATE COLLEGE OF FLORIDALAKEWOOD RANCH, CAMPUSLWR MTSC INTERIOR UPGRADES
SCF PROJECT # 7-19-3-12
78.0
0
78.0
0
A2.1
LIFESAFETY PLANS
A2.1
1 LIFESAFETY PLAN - FIRST FLOORSCALE: 3/32" = 1'-0"
HEPNER ARCHITECTS, INCORPORATED601 S. BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617
DATEDISTRIBUTION
PROJECT NO.
TO THE BEST OF THE ARCHITECT'S KNOWLEDGETHE PLANS AND SPECIFICATIONS ARE COMPLETEAND COMPLY WITH THE FLORIDA BUILDING CODE
COPYRIGHT 2019, HEPNER ARCHITECTS, INCORPORATED. ALL RIGHTS RESERVED
PRIMARY EGRESSEXIT WIDTH IN INCHES (MAXIMUM OCCUPANT LOAD FOR EXIT WIDTH)
--"(--)
200 FT TRAVEL DISTANCE TO EXIT,MAXIMUM 200 FT
197'
(E)
(E) (E)
(N)
EXIT LIGHT(E) DENOTES EXISTING. (N) DENOTES NEW
68"(340)F.E.C (E)
F.E.C (E)
F.E.C (E)
NEW STOREFRONTASSEMBLY
REFERENCED STANDARDS· 2017 (6TH EDITION) FLORIDA BUILDING CODE, BUILDING· 2017 (6TH EDITION) FLORIDA BUILDING CODE, PLUMBING· 6TH EDITION FLORIDA FIRE PREVENTION CODE (FFPC) INCLUDING FLORIDA VERSIONS
OF NFPA 1 AND NFPA 101· 2014 STATE REQUIREMENTS FOR EDUCATIONAL FACILITIES (SREF)
EXISTING BUILDING OCCUPANCY TYPE (6 TH EDITION FBC 2017, SECTION 304 AND 311)BUSINESS. UNCHANGED
EXISTING FIRST FLOOR BUILDING AREA = 20,520 SF.EXISTING SECOND FLOOR BUILDING AREA = 20,578 SF
EXISTING BUILDING CONSTRUCTION TYPE (6 TH EDITION FBC 2017, TABLE 601)TYPE II-B , SPRINKLERED, 2-STORY. UNCHANGED(TO BE VERIFIED BY AUTHORITY HAVING JURISDICTION))
2 DEMOLITION REFLECTED CEILING PLAN - FIRST FLOORSCALE: 3/16" = 1'-0"
0 4 1020 4 102
DEMOLITION WALL LEGENDEXISTING WALL TO REMAIN
REMOVE EXISTING DOOR AND FRAME
REMOVE EXISTING WINDOW AND FRAME
REMOVE EXISTING WALL
DEMOLITION PLAN GENERAL NOTES
DEMOLITION PLAN SPECIFIC NOTES 1
2
EXISTING INTERIOR PARTITION TO REMAIN, TYP.
3 EXISTING MARKER BOARD TO REMAIN
4 EXISTING PROJECTOR SCREEN TO REMAIN
5 EXISTING LIGHT SWITCH TO BE RE-WORKED, SEE ELECTRICAL
6 REMOVE EXISTING MECHANICAL DEVICE, SAVE FOR RE-USE, SEE MECHANICAL
(E) DENOTES EXISTING FURNITURE OR EQUIPMENT TO REMAIN (TO BEINSTALLED AT SAME LOCATION AFTER NEW FINISHES ARE INSTALLED)
(R)
(RE)
DENOTES EXISTING FURNITURE OR EQUIPMENT TO REMOVED TO BEREPLACED AT NEW LOCATION
DENOTES EXISTING FURNITURE OR EQUIPMENT TO BE REMOVED
LIMITS OF CONSTRUCTION
DENOTES AREA NOT IN CONTRACT
1
3
2 5
EXISTING INTERIOR WINDOW ASSEMBLY TO REMAIN, TYP.
4
(RE)
(RE)
(RE)
(RE)
(RE)
(RE)
(RE)
(RE)
(RE)
(RE)
(RE)
6
7
7 REMOVE EXISTING PROJECTOR AND RETURN TO OWNER. PROVIDE COVER PLATE.PROJECTOR CONNECTIONS TO REMAIN FOR FUTURE POSSIBLE USE. SEE ELECTRICAL
8
8 REMOVE EXISTING VCT FLOOR FINISH AND RUBBER BASE
EXISTING SPEAKER TO REMAIN, TYP. (R) DENOTES RELOCATE
EXISTING LIGHT FIXTURE TO REMAIN
S
EXISTING MECHANICAL DEVICES TO REMAIN
EXISTING LIGHT FIXTURE TO BE REMOVED.(R) DENOTES RELOCATE PER NEW PLANS
EXISTING MECHANICAL DEVICE TO BE REMOVED.(R) DENOTES RELOCATE PER NEW PLANS
1. CONTRACTOR TO COORDINATE WITH OWNER FOR ALL ASBESTOS SURVEY AND ABATEMENT WORKCONDUCTED UNDER SEPARATE CONTRACT. NOT A PART OF THIS CONTRACT.
2. GENERAL CONTRACTOR TO COORDINATE ALL DEMOLITION WITH CONTRACT DOCUMENTS FORNEW CONSTRUCTION
3. REMOVE ALL ABANDONED UTILITIES COMPLETELY.
4. WHERE EXISTING SERVICES SUCH AS PLUMBING, ELECTRICAL, ETC. ARE AFFECTED BYDEMOLITION WORK, SUCH AS REMOVAL OF AN EXISTING PARTITION, THE SERVICES SHALL BEREMOVED TO A POINT WHERE THEY CAN BE CAPPED AND TERMINATED UNLESS OTHERWISEINDICATED ON THE DRAWINGS
5. PATCH AND REPAIR ALL CONSTRUCTION TO REMAIN WHERE AFFECTED BY DEMOLITIONOPERATIONS. CUT AND PATCH EXISTING CONSTRUCTION AS REQUIRED TO INSTALL NEW WORK.
6. PROTECT CONSTRUCTION TO REMAIN FROM WEATHER INTRUSION, VANDALISM, AND ALL OTHERRISKS CREATED BY DEMOLITION OPERATIONS.
7. PROTECT ALL EXISTING FINISHES TO REMAIN FROM DAMAGE FOR DURATION OF NEWCONSTRUCTION.
8. PROTECTION - EXERCISE CARE DURING WORK TO PROTECT INTERIOR AND EXTERIOR EXISTINGCONSTRUCTION. REPAIRS TO EXISTING CONSTRUCTION DUE TO DAMAGE SHALL BE DONE AT NOCOST TO THE OWNER.
9. DISPOSE OF ALL DEMOLISHED MATERIAL OFF SITE, EXCEPT FOR MATERIAL THE OWNER WISHESTO REMAIN. PROVIDE THE OWNER WITH THE OPPORTUNITY TO TAG EXISTING ITEMS THEY WISH TOSAVE.
10. REFER TO PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION
11. ALL CONSTRUCTION IS TO BE SEPARATED FROM OCCUPIED SPACES AND EGRESS COMPONENTS.ALL LIFE SAFETY AND MEP SYSTEMS NEED TO REMAIN FUNCTIONAL IN OCCUPIED SPACES.
12. OWNER WILL REMOVE ALL ARTWORK ON THE WALLS PRIOR TO WORK.
13. CONTRACTOR TO REMOVE AND STORE WALL HUNG ITEMS LIKE DRY ERASE BOARDS, CLOCKS,ETC. PRIOR TO WORK AND RE-INSTALL AT SAME LOCATIONS UPON COMPLETION OF WORK.
TYP, UON
NOTE:· REMOVAL OF FURNITURE BY OWNER· NEW FURNITURE PROVIDED AND INSTALLED BY OWNER· EXISTING FURNITURE INSTALLED AT NEW LOCATIONS BY OWNERCONTRACTOR TO COORDINATE REMOVAL AND REPLACEMENT OF FURNITURE AND OTHER WORKWITH OWNER
10'-0"
11'-9
1/2"
9'-9 1
/2" +
/-
8'-4"+/-
2'-0"
2'-0"
S
S
S
S
7'-2"
V.I.F
.
3'-0" 2'-0" 4'-0"
11'-8 3/4" +/- V.I.F.
9'-6"
V.I.F
.
A5.1NEW PLANSFIRST FLOOR
A5.1
1 NEW FLOOR PLAN SCALE: 3/16" = 1'-0"
HEPNER ARCHITECTS, INCORPORATED601 S. BOULEVARD, SUITE 101TAMPA, FLORIDA 33606813-229-0614AA 0002617
DATEDISTRIBUTION
PROJECT NO.
TO THE BEST OF THE ARCHITECT'S KNOWLEDGETHE PLANS AND SPECIFICATIONS ARE COMPLETEAND COMPLY WITH THE FLORIDA BUILDING CODE
COPYRIGHT 2019, HEPNER ARCHITECTS, INCORPORATED. ALL RIGHTS RESERVED
· (1)2' WIDE FULL LIGHT PANEL NEXT TO DOOR.· REST OF THE WALL LENGTH: SOLID PANELS, 4' WIDE MODULE STARTING
FROM DOOR SIDE.· FILLER PANEL AT WALL ENDPROVIDE SHOP DRAWINGS FOR OWNER'S REVIEW
6
7
8
9
EXISTING MECHANICAL DEVICES TO REMAIN, TYP UNO
1
2
3
4
NEW DIFFUSER
5
EXISTING CEILING GRID AND TILE TO REMAIN, TYP.
EXISTING LIGHT FIXTURES TO REMAIN, TYP.
EXISTING WINDOW TO REMAIN, TYP.
EXISTING PROJECTOR SCREEN TO REMAIN
RELOCATE RETURN DEVICE
LIMITS OF CONSTRUCTION
EXISTING ACOUSTICAL CEILING TILE ANDGRID TO REMAIN, TYP.
EXISTING SPEAKER TO REMAIN, TYP.
EXISTING LIGHT FIXTURE TO REMAIN
NEW CARPET, SEE FINISH SCHEDULE
S
EXISTING SPRINKLER TO REMAIN, TYP.
EXISTING MECHANICAL DEVICESTO REMAIN
NEW OR RELOCATED MECHANICALDEVICES
DENOTES AREA NOT IN CONTRACT
6
7
4
5
3
9
8
7
10
B
A
BASE CEILINGWALLS
FINISH LEGEND
CEILING HEIGHT
ROOM NAME
ROOM NUMBER
CEILING FINISHWALL FINISHBASE FINISHFLOOR FINISH
RECEPTIONB,C/B/C/C9'-0"
101
ROOM LEGEND
C
FLOOR
CARPET: CP2
CARPET: CP1
EXISTING TOREMAIN
EXISTING TOREMAIN
NEW CEILING TILES(EXISTING CEILING GRID):
C1
PAINTEXISTING GYP BD FINISH.
P1 AND P2
SEE FINISH SCHEDULE, SEE A-61
--
-
-
RUBBERB1
8'-0"133 VESTIBULE
A/A/A/C
8'-0"133A OFFICE
A/A/A/C
8'-0"133B OFFICE
A/A/A/C
EXISTING TOREMAIN
10 LOCATION OF NEW LIGHT SWITCH
10
10
3
2
1
2 OFFICE CHAIR
3 VISITOR'S CHAIR
4 MEETING TABLE
FURNITURE LEGEND
1. FIELD VERIFY ALL DIMENSIONS ASSOCIATED WITH EXISTING CONSTRUCTION.
2. ALTERED SURFACES WITHIN CONSTRUCTION LIMITS SHALL BE PATCHED AND REPAIRED TOCONDITION THAT MATCHES THE EXISTING ADJACENT CONSTRUCTION.
3. PATCH ANY EXISTING CONSTRUCTION AS REQUIRED WHICH IS DAMAGED DUE TO THEINSTALLATION OF NEW FIXTURES, ELECTRICAL DEVICES, EQUIPMENT, OR ANY OTHER NEWCOMPONENT.
4. CONTRACTOR SHALL CHECK EXISTING FLOOR SLABS FOR LEVEL AFTER COMPLETION OFDEMOLITION WORK AND NOTIFY THE ARCHITECT OF ANY DEVIATION FROM SPECIFIEDTOLERANCES. CORRECTIVE WORK SHALL BE ACCOMPLISHED PRIOR TO INSTATING NEWCONSTRUCTION.
5. ITEMS LOCATED IN ACOUSTICAL CEILINGS ARE CENTERED IN CEILING PANELS OR AS NOTED.
1
1
1 OFFICE SYSTEM FURNITURE GROUP-A
2
3
3
4
TYP.
TYP.
5 LOUNGE CHAIR (EXISTING)
6 LARGE TABLE
7 STUDENT CHAIR
133
133A
133B
147
145
129
134
ROOM LEGEND SPACE SPACE NAME
100 LOBBY129 RECWPTION132 CONFERENCE
133 VESTIBULE133A OFFICE133B OFFICE
134 OFFICE135 OFFICE147 BREAK ROOM
(E)
(N)
NEW EXIT SIGN(E) DENOTES EXISTING, (N) DENOTES NEW
P2: PAINT (ACCENT)MFTR: BENJAMIN MOORE, ULTRA SPEC 500COLOR:SEE TABLE BELOWFINISH: INTERIOR SEMIGLOSSCOATS: (1) PRIMER, (2) FINISH COATS
P-A: COLOR MATCH SW 6524 COMMODOREP-B: COLOR MATCH SW 6487 CLOUDBURSTP-C: COLOR MATCH SW 6437 HAVENP-D: COLOR MATCH SW 6946 SURFERP-E: COLOR MATCH SW 7018 DOVETAILP-F: COLOR MATCH SW 6712 LUAU
P3: PAINT DOOR FRAMESMFTR: BENJAMIN MOORE,ADVANCE WATERBORNE INTERIOR EXTERIORALKYDCOLOR:COLOR MATCH SW7018 DOVETAILFINISH: INTERIOR SEMIGLOSSCOATS: (1) PRIMER, (2) FINISH COATSPAINT ALL WOOD FRAMES, HM FRAMES
P1: PAINT (TYPICAL THROUGHOUT U.N.O.)MFTR: BENJAMIN MOORE, ULTRA SPEC 500COLOR: COLOR MATCH SW 7065 ARGOSFINISH: INTERIOR SEMIGLOSSCOATS: (1) PRIMER, (2) FINISH COATS
NEW DE-MOUNTABLE PARTITION ASSEMBLY. SEE 3/A5.1"TRENDWALL" SYSTEM BY TRENDWAY. https://www.trendway.com/product/trendwall/CONTACT: EDURADO CHAVES, EMAIL: [email protected] , PHONE: 954-551-1029 FURNITURE PROVIDED AND INSTALLED BY OWNER
5A EXISTING MARKER BOARD TO REMAIN
A5.1
3 DE-MOUNTABLE WALLSCALE: 3/8" = 1'-0" NOTE:
1. ELEVATION OF WALL ON SOUTH OF 133A SIMILAR. PROVIDE(1) 2'-0" WIDE SIDE LIGHT PANEL, (3) 4'-0" SOLID PANELS, AND (1)INFILL PANEL
2. PROVIDE ALL DETAILS PER MANUFACTURER'S STANDARDS3. VINYL COLOR FOR DOOR: RUSSIAN MAPLE AS34. VINYL COLOR ON SOLID PANELS: TEXTURED LIGHT GRAY V515. PAINT COLOR ON TRIM PIECES: LIGHT GRAY-L