Spacial, Thalassa, ClimaSys Universal enclosures Briefing
Post on 21-Jan-2018
52 Views
Preview:
Transcript
Spacial, Thalassa, ClimaSys
Universal enclosures briefing
Property of Schneider Electric
Simply reliable. Simply available.
December 2017
• Introduction to the Enclosure offer
• How to select an enclosure
Technical needs
Components and Accessories
Thermal
• Range overview
• How to understand our references
• Where to find further details
• Quiz
Table of content
Property of Schneider Electric | Page 2
Enclosure's role
Page 3Property of Schneider Electric |
Enclosure system = electrical devices
conditioning solution
Devices: Installation and cabling,
thermal dissipation
People: Operator control and
maintenance, ergonomic and protection,
and access
Ambiance: Dust, water, temperature
changes, sunlight, chemical agents, radio
waves, vibrations, cleaning agents,
vandalism, etc.
&
>< ><>
>
&& & && & && & &
&&&
Enclosure’s role
Page 4Property of Schneider Electric |
• Class II: Total
insulation
product
• No sharp edges
• Surface
temperature
• No penetration
of object when
IP > 4X
&• Vandalism
• Shock
• Flame
• Forced entry
• Theft
• Humidity and
condensation
• Thermal stress
• Overheating
• Corrosion
• Chemicals
• High
temperature
• UV rays
• Air pollution
• Snow
• Dust
• Support for
HMI functions
• Time saving on
installation
• Perfect fit of
enclosure +
device + thermal
conditioning
People
protection
Device
protection
Thermal
management
Harsh
environment
Human-machine
interface (HMI)
Best-in-class
installation
system
How to select the right enclosure and its accessories
Page 6Property of Schneider Electric |
In just 4 steps ... Think on ...
• Indoor
- Spacial — Steel for
standard
- Spacial — Stainless
steel
for harsh environment
• Outdoor
- Thalassa — Polyester
for standard
- Spacial and Thalassa
— Heavy duty for
harsh environment
1• Tightness (IP)
• Impact resistance (IK)
• Size constraints
(HxWxD)
• Color
• Mounting architecture
(floor, wall, post) and its
accessories (Plinth, etc.)
2• Door system
- Transparent/blind
- Lock, earthing,
raceways
• Cable entry system and
position
• Mounting accessories
- Mounting plate (plane,
Telequick system,
modular, 19” )
- Cabling accessories
3Thermal calculation with
ProClima software and
Climasys offer selection
• Ventilation
• Cooling
• Heating
• Thermal measurement
and control
4Environment
Technical
needs
Components and
accessoriesThermal
Technical needs
Page 7Property of Schneider Electric |
• According
to IEC 60529
• Certification
according
to UL 50E
• NEMA type
according
to NEMA 250
standard
• Resistance
to external
mechanical
impact
IEC 62262
• Up to IK 10
• Dimensions
of the
enclosure:
Height (H) x
Width (W) x
Depth (D)
• Take into
account the
possibilities
for modular
enclosure
associations
Enclosures and
accessories to fit
centralized or
distributed
machine
architecture
• Boxes
• Wall mounting
• Floor standing
• Post
• HMI
• Post fixing
devices
• Specific specs
• Seismic
• Vibration
• Corrosion
resistance
• EMC
• Steel RAL 7035
• Polyester RAL
7032
Accessories
• Canopy
• Plant
• Eyebolts
• Fixing lugs
• Reinforcement
for heavy
devices
IP IK
2Tightness Impact resistance Size Architecture ColorAccessories and specific specs
Components and accessories
Page 8Property of Schneider Electric |
3
• To see inside: Glazed door, acrylic windows,
control protection frames
• Lock: Inserts, keys, padlocks
• For maintenance: Door stops, switches
• Raceways door mounted:
Cable-duct, door cross-rails,
cable ties
• HMI device installation accessories
• Cable entry number and type selection
• Cable glands or membranes: Tightness and
cable supports
• Earth connection: Electrical continuity by
earthing braids or leads
• Device mounting accessories
• Power distribution
• Equipment mounting plates
- Plain for DIN devices
- Telequick System for nonDIN device
(micro-perforated or perforated)
- Modular
- 19” device installation system
• Cable accessories
- Cable ducts
- Cross rails
- Cable supports
• HMI device accessories
+Door Body or frame Mounting accessories
Optimization
• Our experience: Customers either oversize
or undersize thermal solutions
• The same machine that is exported in
different geographical zones normally
needs and specs
are different solutions (even indoors)
(e.g., RU -15 … +30 ºC , UAE +20 … +55
ºC)
What
Reliability
• One of the most sensitive aspects for
getting the machine reliable; control panel
conditioning ensures device lifetime and
reliability
Thermal
Page 9Property of Schneider Electric |
4
The only way or action to validate the correct thermal installation is to use thermal calculation software
Installation for outdoors
• Private or public installation
• Geographical location of the installation to set
thermal working conditions using the global
ProClima built-in weather database
- Sun radiation value (W/m2)
- Temperature and humidity data
Installation for indoor and outdoor
• Mounting position of the enclosure (on wall, etc.)
• Enclosure material and RAL color
• Dimensions of the machine control panel
• Watts dissipated by the installed devices
(if customer doesn't know, ProClima will help)
Thermal
Page 10Property of Schneider Electric |
4
Knowing all these variables in advance, ProClima software suggests thermal solutions for your customer.
How
Thermal calculation with minimum customer data to start
General overview of enclosures
Page 11Property of Schneider Electric |
Outdoor
Spacial steel
Indoor
Spacial stainless steel Thalassapolyester
Thalassa PHD heavy duty polyester
Spacial SFHD/S3DHD
heavy duty steel
Standard environment Harsh environment Standard environment Harsh environment
Material
architecture
accessories +All offers are ready
for thermal conditioning
solutions
General overview of enclosures
Page 12Property of Schneider Electric |
Indoor standard environment Indoor harsh environment Outdoor harsh environment
Spacial steel Spacial stainless steel
Spacial in steel: Boxes, wall mounting,
monobloc, and suitable floor standing
Key benefits
• Protection of electric and electronic devices
against dust, splashing with oil, and impacts
• Safe access of people to devices
Performance
• Universal range for industry
• E.M.C. range against
electromagnetic disturbances
(treated with Aluzing)
• ATEX version available
Spacial in stainless steel: Wall mounting, monobloc,
and suitable floor standing
Key benefits (additional to steel)
• Suitable to demands from F&B, Life Sciences,
and infrastructure industries
• Hygiene and corrosion-resistant properties
Performance
• 304 L stainless steel resistant to corrosion
and suitable for cleaning and disinfection
• 316 L stainless steel (“marine stainless
steel”) high resistance to corrosion
• ATEX version available
General overview of enclosures
Page 13Property of Schneider Electric |
Outdoor Standard Environment
Thalassa polyesterhalassa polyester
Thalassa in polyester or plastic (ABS, polycarbonate):
Boxes, wall mounting, and floor standing
Key benefits
• Outdoor infrastructures and electrical installations protection to sunlight, rain,
saline mist, extreme temperatures, oil splashes, and chemical and corrosive agents
• Safe protection for those in contact with public
• Insulated (to be Class II according to IEC 61439-1:2011)
Performance
• Universal range for industry and infrastructure
• ATEX version available
• Lightweight
• Fire resistant
General overview of enclosures
Page 14Property of Schneider Electric |
Outdoor Standard Environment
Spacial SFHD/S3DHD heavy duty steel
Spacial heavy duty made from carbon steel
protected against corrosion (certified C4H ISO 12944)
• IP55 floor standing
Thalassa PHD heavy duty polyester
Thalassa heavy duty polyester reinforced
with a double layer of fiberglass that is ultra-resistant to
vandalism
• Enclosure includes heavy duty canopy and Plinth, locking
system with 1242E key and padlock, aluminum cable
gland plate
• Anti-posting door
Key benefits (additional to steel
and polyester)
• For severe outdoor environments
• Tested, certified for outdoor compliance
standards
• Active/passive thermal management
engineering right in
• Resistant to chemicals
Performance
• Dedicated accessories pre-installed for
outdoor conditions
• -45 °C up to +80 °C resistance
• Pressure and shock resistant IEC
61439-5:2010
• IP66 wall mounting
ClimaSys: Thermal management overview
Page 15Property of Schneider Electric |
Thermal management software
Enclosures
offer
Passive thermal solutions
Mechatronic
devices
Small thermal offer Big thermal offer
Airing Ventilation
from 38 to 850 m3/h
Control Heaters
from 10 W to 550 W
Cooling units
from 0.3 kW
to 15 kW
Exchangers
air water
from 1 kW to 15 kW
Exchangers air
from 22 W/K to 80 W/K
Thermal management should guarantee suitable control of the temperature and humidity conditions inside the
enclosure to guarantee optimal operation of the components installed in the inside.
What is thermal management?
Page 16Property of Schneider Electric |
Thermal
management
software
Airing
Property of Schneider Electric | Page 17
• Using natural convection
- Useful in technical rooms
- Clean and filtered ambients
- Only for low dissipate powers
- And good external
temperatures
Filterless grill
Filter can be removed
for filtered ambients
Internal convection
Property of Schneider Electric | Page 18
• Generating intense and continuous
turbulences inside the enclosure.
We homogenize and reduce
internal temperature.
- Useful in outdoors and technical rooms
- High water-tightness
- Only for low dissipate powers
- And good external temperatures
Ti1 > Ti2
Ti1 Ti2
Forced ventilation
Property of Schneider Electric | Page 19
• Renews the air inside the enclosure
with cold air from the outside using the
necessary flow to achieve a suitable
DT (Te -Ti ≤ 5 ºC)
• Maintains the IP required in each case
- Useful in technical rooms and outdoors
- Up to IP55
- Depends on dT (Te -Ti ≤ 5 ºC)
- Control equipment is required
Ti
ClimaSys forced ventilation
Ti1 > Ti2
Te
Cooling: Cooling units
Property of Schneider Electric | Page 20
• Cool and dehumidify
• Watertightness is mandatory
• ΔTneeded = inexistent
• IPmax = IP55
ClimaSys cooling units
TiTe Ti
Te
Humidity and low temperatures: Heating
Property of Schneider Electric | Page 21
• Avoid condensation, high
humidity, and low temperatures
• IPmax = IP66
Initial
conditions
Ti = 10 ºC
RH = 63 %
Ti = 20 ºC
RH = 33 %
Ti = 35 ºC
RH = 14 %
Heating units
+
Control
Ti = 5 ºC
RH = 90 %
Function control
Property of Schneider Electric | Page 22
• TH thermostats, HY hygrostats,
and HYT hygrotherm
• Regulates and optimizes the
working temperature conditions
inside the enclosure
• Prolongs the lifetime of thermal
components installed
ClimaSys thermal control
L
N
+L
N
+
L
N
+
Understand our references
Page 23Property of Schneider Electric |
Thalassa insulating enclosures Spacial metal enclosures ClimaSys
Universal enclosures code
Product family
See the new names above
Specifications
Dimensions, power,type of function
Composition
Type of door, material, additional accessories
N S Y S F T1 8 8 5 0Spacial SF/steel floor-standing suitable – 1800x800x50
N S Y T B T2 4 1 9 8Thalassa TBS/industrial boxes in ABS – 241x194x87S
• Thalassa TBP
Industrial boxes PC
(UL)
• Thalassa TBS
Industrial boxes in
ABS
• Thalassa PLS
Insulating modular
boxes
• Thalassa PLM
Wall-mounting
in polyester
• Thalassa PLA
Floor-standing
in polyester
• Thalassa PLD
Floor-standing DIN in
polyester
• Spacial S44 – S57 – SDB
Steel industrial boxes
• Spacial S3D
Steel wall-mounting
• Spacial SF
Steel floor-standing suitable
• Spacial SM
Steel floor-standing compact
• Spacial SD
Steel control desk
• Spacial S3X
Stainless-steel wall-mounting
• Spacial SMX
Stainless-steel floor-standing
monoblock
• Spacial SFX
Stainless-steel floor-standing
suitable
• Spacial SDX
Stainless-steel control desk
• ClimaSys CV
Ventilation system
• ClimaSys CA
Natural airing
• ClimaSys CU
Cooling units
• ClimaSys CE
Exchangers
• ClimaSys CR
Resistance heaters
• ClimaSys CC
Thermal controlc
Universal enclosures digital tools gateway
Page 24Property of Schneider Electric |
2D/3D filesOn traceparts.net
and by packages
Eplan macros2-D and 3-D format
Catalog General catalog
and technical guides
Digital rulesSelection software suite
for enclosures and
accessories
ProClimaThermal calculation
software for control panel
Spacial.proDimension sizer software
for control panel
Spacial.confQuotation software for
customized enclosures
Spacial, Thalassa,
ClimaSys
Check for latest version online
If links not active, please download
• IEC 62208: Standard for empty enclosures
‒ Standard used for enclosures prior to the installation
of equipment, including:
– IEC 60529: Degrees of protection provided by enclosure (IP)
– IEC 62262: Degrees of protection provided by enclosure (IK)
• IEC 61439: Low voltage switchgear and control
gear assemblies
• UL508A: Industrial control panels
• Dedicated: Seismic, marine, nuclear, EMC, outdoor, etc.
Main international standards
Property of Schneider Electric | Page 25
• Click here to find info on SE.com
• Click here to find Enclosures on
SE.com
• Click here to access our Digicat
• Click here to access to CAD files
• Click on the link below for FAQs
(frequently asked question)
Where to find details
Property of Schneider Electric | Page 26
Property of Schneider Electric |
Quiz
Based on what
you’ve learned so
far, try to answer to
this quiz
?
Page 27
Q1
Give three enclosure’s role
Q2
What are the two main ranges of enclosures?
Q3
What is Climasys range?
Q4
What is the software used for Climasys range?
Q5
Is there ATEX version available in Enclosure range?
Property of Schneider Electric |
Quiz answers
Q1
Give three enclosure’s role
People protection, Thermal management, Protect for Harsh environment
Q2
What are the two main ranges of enclosures?
Thalassa range (steel) and Spacial range (polyester)
Q3
What is Climasys range?
It’s Thermal management offer
Q4
What is the software used for Climasys range?
ProClima for thermal calculation and EffiClima for thermal tracking
Q5
Is there ATEX version available in Enclosure range?
Yes, ATEX version is available
Answers
Page 28
top related