SIG-300 - pro-lite.fr · The Radiant Zemax SIG-300™ (Source Imaging Goniometer, Gen.3) is a fully automated, computer-controlled goniometric system that uses the PM-1600F ™ Series
Post on 18-Jul-2020
0 Views
Preview:
Transcript
The industry standard for near-field modeling of most light sources
Source Imaging Goniometer®
SIG-300™
• Measurement of near-field luminous intensity distributions and chromaticity for arbitrary light sources
• Creation of accurate rays sets for use in major optical design software packages
• Generates near-field models for customer optical designs and prototype testing
Applications
Benefits
• Collects both image and ray set data
• Generates industry standard Radiant Source Models™
• Exports ray sets to all major optical design programs using ProSource®
• Measures sources in vertical and horizontal orientation
The Radiant Zemax SIG-300™ (Source Imaging Goniometer, Gen.3) is a fully automated, computer-controlled goniometric system that uses the PM-1600F™ Series Imaging Colorimeter to capture a precise model of light source’s near-field output. With a complete and precise characterization of light source data, the SIG-300™ enables better design evaluations in a time efficient manner, more accurate optical designs for luminaries, smaller ray sets and the creation of more useful light sources. Add ProSource® Software and the data can be imported into any major optical design package to allow accurate design of lighting systems.
Excellent data quality is a product of an excellent design system. The SIG-300™ has been designed out of steel construction for minimized wobble, optical calibration, software tracking, and includes a Radiant Source Model™ (RSM) data set for all images. Light sources ranging in size from LED to medium can achieve precise levels of measurement, (as well as luminance and chromaticity as a function of angle).
The SIG-300™ produces optical designs that agree with real world measurements and allow for viewing of any source data from all view points to observe performance. Fewer ray sets are needed to achieve the same accuracy of optical design, translating into a major timesaver. Additionally, with the control and analysis software, test set-up and iteration of data is made easy.
The construction of the Radiant Zemax SIG-300™, and it’s relatives the SIG-310™ and SIG-400™, are stronger and more stable, making them the industry standard.
Radiant Zemax LLC 22908 NE Alder Crest Drive, Suite 100 Redmond, WA 98053, USA
T: +1 425 844-0152 F: +1 425 844-0153
Sales and marketing: sales@radiantzemax.com Technical support: support@radiantzemax.com Web site: RadiantZemax.com
Copyright © 2012 Radiant Zemax LLC,All Rights Reserved
Key FeaturesSource Imaging Goniometer SIG-300™
Optical Specifications
CCD Type Full-frame, cooled and temperature stabilized CCDCCD Bit Depth 16-bit (65,536:1) dynamic range
Resolution Either 512 x 512 or 1024 x 1024 pixel CCD optionsField of view (FOV)
CIE 1931 matched XYZ filters Color Measurement
Neutral Density Filters ND 0, 1, 2, 3, 4, and 5 standard
512x512 pixel CCD 1024x2024 pixel CCD
40 mm
2 mm, 4 mm, 8 mm, 14 mm, 20 mm
80 mm
5 mm, 10 mm, 14 mm, 28 mm
Standard FOV
Extended FOV: Large
Extended FOV: Micro 0.5 mm 1.2 mm
Mechanical Specifications
120 cm x 77 cm x 177 cmOverall Size
Operating Footprint 120 cm x 120 cm
Polar Motion
Azimuth Motion Angular Step Size
-10° to 370°
Within 24° of lamp axis
0.10° minimum for both polar and azimuth motion
Less then 0.025 mm mechanical-optical-software run outRun OutWeight 360 kg
Welded steel frame for thermal stability and rigidityConstruction
Control and Analysis Software Specifications Measurement Capability Luminance, luminous intensity
Color: CCT; CIE x,y; u’,v’; ESIG 2.0 Software Automated motion and image capture control
Real-time, on-screen video displayGray-scale and false color displayRecord ambient alignment images for sampleOn-screen alignment cursors
Luminance cross-sectionCandela cross-section3-dimensional surface plot of luminanceIsometric plot of luminanceAngular distribution graphs for luminous intensityGraph and image comparison for multiple captures
Graphs and charts
• Support for both horizontal and vertical light source mounting
• Provides near-field models for luminance and color
• Multiple optical configurations for field of view and resolution
• Generates Radiant Source Models™ with integrated image data
• Extremely stable for accurate models of LEDs and Arc Sources
• NEW Easier, more intuitive spectrometer setup
* Specifications subject to change without notice
Specifications*
Radiant Zemax LLC 22908 NE Alder Crest Drive, Suite 100 Redmond, WA 98053, USA
T: +1 425 844-0152 F: +1 425 844-0153
Sales and marketing: sales@radiantzemax.com Technical support: support@radiantzemax.com Web site: RadiantZemax.com
Copyright © 2012 Radiant Zemax LLC,All Rights Reserved
SIG 2.1 System Requirements• 2.0 GHz or faster processor
• 1GB or greater RAM
• Windows® 7 or 8
• USB 2.0 / 3.0 interface
• Ethernet port