The industry standard for near-field modeling of most light sources Source Imaging Goniometer® SIG-300 Measurement of near-field luminous intensity distributions and chromaticity for arbitrary light sources Creation of accurate rays sets for use in major optical design software packages Generates near-field models for customer optical designs and prototype testing Applications Benefits Collects both image and ray set data Generates industry standard Radiant Source Models Exports ray sets to all major optical design programs using ProSource ® Measures sources in vertical and horizontal orientation The Radiant Zemax SIG-300 (Source Imaging Goniometer, Gen.3) is a fully automated, computer-controlled goniometric system that uses the PM-1600F Series Imaging Colorimeter to capture a precise model of light source’s near-field output. With a complete and precise characterization of light source data, the SIG- 300 enables better design evaluations in a time efficient manner, more accurate optical designs for luminaries, smaller ray sets and the creation of more useful light sources. Add ProSource ® Software and the data can be imported into any major optical design package to allow accurate design of lighting systems. Excellent data quality is a product of an excellent design system. The SIG- 300 has been designed out of steel construction for minimized wobble, optical calibration, software tracking, and includes a Radiant Source Model (RSM) data set for all images. Light sources ranging in size from LED to medium can achieve precise levels of measurement, (as well as luminance and chromaticity as a function of angle). The SIG-300 produces optical designs that agree with real world measurements and allow for viewing of any source data from all view points to observe performance. Fewer ray sets are needed to achieve the same accuracy of optical design, translating into a major timesaver. Additionally, with the control and analysis software, test set-up and iteration of data is made easy. The construction of the Radiant Zemax SIG-300 , and it’s relatives the SIG-310 and SIG-400 , are stronger and more stable, making them the industry standard. Radiant Zemax LLC 22908 NE Alder Crest Drive, Suite 100 Redmond, WA 98053, USA T: +1 425 844-0152 F: +1 425 844-0153 Sales and marketing: [email protected] Technical support: [email protected] Web site: RadiantZemax.com Copyright © 2012 Radiant Zemax LLC, All Rights Reserved
2

SIG-300 - pro-lite.fr · The Radiant Zemax SIG-300™ (Source Imaging Goniometer, Gen.3) is a fully automated, computer-controlled goniometric system that uses the PM-1600F ™ Series

Jul 18, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: SIG-300 - pro-lite.fr · The Radiant Zemax SIG-300™ (Source Imaging Goniometer, Gen.3) is a fully automated, computer-controlled goniometric system that uses the PM-1600F ™ Series

The industry standard for near-field modeling of most light sources

Source Imaging Goniometer®

SIG-300™

• Measurement of near-field luminous intensity distributions and chromaticity for arbitrary light sources

• Creation of accurate rays sets for use in major optical design software packages

• Generates near-field models for customer optical designs and prototype testing

Applications

Benefits

• Collects both image and ray set data

• Generates industry standard Radiant Source Models™

• Exports ray sets to all major optical design programs using ProSource®

• Measures sources in vertical and horizontal orientation

The Radiant Zemax SIG-300™ (Source Imaging Goniometer, Gen.3) is a fully automated, computer-controlled goniometric system that uses the PM-1600F™ Series Imaging Colorimeter to capture a precise model of light source’s near-field output. With a complete and precise characterization of light source data, the SIG-300™ enables better design evaluations in a time efficient manner, more accurate optical designs for luminaries, smaller ray sets and the creation of more useful light sources. Add ProSource® Software and the data can be imported into any major optical design package to allow accurate design of lighting systems.

Excellent data quality is a product of an excellent design system. The SIG-300™ has been designed out of steel construction for minimized wobble, optical calibration, software tracking, and includes a Radiant Source Model™ (RSM) data set for all images. Light sources ranging in size from LED to medium can achieve precise levels of measurement, (as well as luminance and chromaticity as a function of angle).

The SIG-300™ produces optical designs that agree with real world measurements and allow for viewing of any source data from all view points to observe performance. Fewer ray sets are needed to achieve the same accuracy of optical design, translating into a major timesaver. Additionally, with the control and analysis software, test set-up and iteration of data is made easy.

The construction of the Radiant Zemax SIG-300™, and it’s relatives the SIG-310™ and SIG-400™, are stronger and more stable, making them the industry standard.

Radiant Zemax LLC 22908 NE Alder Crest Drive, Suite 100 Redmond, WA 98053, USA

T: +1 425 844-0152 F: +1 425 844-0153

Sales and marketing: [email protected] Technical support: [email protected] Web site: RadiantZemax.com

Copyright © 2012 Radiant Zemax LLC,All Rights Reserved

Page 2: SIG-300 - pro-lite.fr · The Radiant Zemax SIG-300™ (Source Imaging Goniometer, Gen.3) is a fully automated, computer-controlled goniometric system that uses the PM-1600F ™ Series

Key FeaturesSource Imaging Goniometer SIG-300™

Optical Specifications

CCD Type Full-frame, cooled and temperature stabilized CCDCCD Bit Depth 16-bit (65,536:1) dynamic range

Resolution Either 512 x 512 or 1024 x 1024 pixel CCD optionsField of view (FOV)

CIE 1931 matched XYZ filters Color Measurement

Neutral Density Filters ND 0, 1, 2, 3, 4, and 5 standard

512x512 pixel CCD 1024x2024 pixel CCD

40 mm

2 mm, 4 mm, 8 mm, 14 mm, 20 mm

80 mm

5 mm, 10 mm, 14 mm, 28 mm

Standard FOV

Extended FOV: Large

Extended FOV: Micro 0.5 mm 1.2 mm

Mechanical Specifications

120 cm x 77 cm x 177 cmOverall Size

Operating Footprint 120 cm x 120 cm

Polar Motion

Azimuth Motion Angular Step Size

-10° to 370°

Within 24° of lamp axis

0.10° minimum for both polar and azimuth motion

Less then 0.025 mm mechanical-optical-software run outRun OutWeight 360 kg

Welded steel frame for thermal stability and rigidityConstruction

Control and Analysis Software Specifications Measurement Capability Luminance, luminous intensity

Color: CCT; CIE x,y; u’,v’; ESIG 2.0 Software Automated motion and image capture control

Real-time, on-screen video displayGray-scale and false color displayRecord ambient alignment images for sampleOn-screen alignment cursors

Luminance cross-sectionCandela cross-section3-dimensional surface plot of luminanceIsometric plot of luminanceAngular distribution graphs for luminous intensityGraph and image comparison for multiple captures

Graphs and charts

• Support for both horizontal and vertical light source mounting

• Provides near-field models for luminance and color

• Multiple optical configurations for field of view and resolution

• Generates Radiant Source Models™ with integrated image data

• Extremely stable for accurate models of LEDs and Arc Sources

• NEW Easier, more intuitive spectrometer setup

* Specifications subject to change without notice

Specifications*

Radiant Zemax LLC 22908 NE Alder Crest Drive, Suite 100 Redmond, WA 98053, USA

T: +1 425 844-0152 F: +1 425 844-0153

Sales and marketing: [email protected] Technical support: [email protected] Web site: RadiantZemax.com

Copyright © 2012 Radiant Zemax LLC,All Rights Reserved

SIG 2.1 System Requirements• 2.0 GHz or faster processor

• 1GB or greater RAM

• Windows® 7 or 8

• USB 2.0 / 3.0 interface

• Ethernet port