BUrners TRAining CEntre

RES G RESIDENTIAL PROJECT

1st step: Comparison between us & the competitors

2nd step: Definition of the required features target: ‘how to be the best’

3rd step: R&D development target: ‘to be the best’3rd step: R&D development target: ‘to be the best’

2nd step: Definition of the required features target: ‘how to be the best’

BUrners TRAining CEntre

2nd step: Definition of the required features target: ‘how to be the best’

COMBUSTION HEAD

Meku and MAN’s seem to be the only ones technologiesable to achieve RAL UZ 9 performances;

MAN’s head has high resistence Meku has high resistance too; moreover there is a patent (high cost) and some problems on ‘cold’ startings. No flexibility.

Weishaupt is not a LOW NOx burner

BG does not match the new RAL UZ9; BGK has someproblems on commercial boilers

BUrners TRAining CEntre

2nd step: Definition of the required features target: ‘how to be the best’

COMBUSTION HEAD: better than Meku

Increasing the flexibility of application (few models)

Reducing the resistance

Doing something different to be out of the patent

Reliable operation mode

Same or lower emissions

BUrners TRAining CEntre

COMBUSTION HEAD: result

3rd step: R&D development target: ‘to be the best’

Riello design: air staging

An adjustable external re-circulation

keeps low the NOx emissionsFrom the middle

‘swirl’

Around the ‘airnozzle’ (adjustable)

Four small pipesto decrease the resistance

end to complete the combustion

BUrners TRAining CEntre

COMBUSTION HEAD: result

3rd step: R&D development target: ‘to be the best’

RES G XXR BLU 15.4 - 30.8 kWRES G XXR BLU 28 - 43 kWRES G XXR BLU 40.6 - 51.7 kW

…THREE HEAD SIZES: T1; T2; T3===> THREE MODELS:

BUrners TRAining CEntre

COMBUSTION HEAD PERFORMANCES

3rd step: R&D development target: ‘to be the best’

05

101520253035

[m/kWh]

min (15.4) max (30.8)

Capacity [kW]

CO

DIRECTC.CHAMBER

REVERSINGCHAMBER

0

20

40

60

80

100

[m/kWh]

min (15.4) max (30.8)

Capacity [kW]

NOx

DIRECTC.CHAMBER

REVERSINGCHAMBER

T1 HEAD

BUrners TRAining CEntre

COMBUSTION HEAD PERFORMANCES

3rd step: R&D development target: ‘to be the best’

0

5

10

15

20

[m/kWh]

min (28) max (43)

Capacity [kW]

CO

DIRECTC.CHAMBER

REVERSINGCHAMBER

7880828486889092

[m/kWh]

min (28) max (43)

Capacity [kW]

NOx

DIRECTC.CHAMBER

REVERSINGCHAMBER

T2 HEAD

BUrners TRAining CEntre

COMBUSTION HEAD PERFORMANCES

3rd step: R&D development target: ‘to be the best’

0

5

10

15

20

[m/kWh]

min (40.6) max (51.7)

Capacity [kW]

CO

DIRECTC.CHAMBER

REVERSINGCHAMBER

75

80

85

90

95

100

[m/kWh]

min (40.6) max (51.7)

Capacity [kW]

NOx

DIRECTC.CHAMBER

REVERSINGCHAMBER

T3 HEAD

BUrners TRAining CEntre

COMBUSTION HEAD PERFORMANCES

3rd step: R&D development target: ‘to be the best’

T... HEADs

RESISTANCES

0

5

10

15

20

25

30

5 15 25 35 45 55

air flow [m3/h]

[mb

ar]

T1

T2

T3

BG 1

MAN

BUrners TRAining CEntre

VENTILATION

3rd step: R&D development target: ‘to be the best’

NEW PROJECT

BUrners TRAining CEntre

3rd step: R&D development target: ‘to be the best’

0

5

10

15

20

25

30

35

0 10 20 30 40 50 60

[m3/h]

[mb

ar] RES (no

head)

MAN (nohead)

VENTILATION

NEW PROJECT

BUrners TRAining CEntre

3rd step: R&D development target: ‘to be the best’

0

5

10

15

20

25

30

35

0 10 20 30 40 50 60

[m3/h]

[mb

ar] T 1

T 2

T 3

NO HEAD

VENTILATION

NEW PROJECT

BUrners TRAining CEntre

INSIDE NOISE (50 kW: 61,7 dB(A))

0

10

20

30

40

50

60

70

80

20

31,5 50 80 125

200

315

500

800

1250

2000

3150

5000

8000

1250

0

2000

0

frequency [Hz]

dB

3rd step: R&D development target: ‘to be the best’

VENTILATION

BUrners TRAining CEntre

RES G RESIDENTIAL PROJECT3rd step: R&D development target: ‘to be the best’

MAIN COMPONENTS:combustion heads designed by Riello (Patent)new ventilation projectcontrol box 556R SE designed by Riellomotor 150W designed by Riellooil pump designed by Rielloflame sensor QRC by Siemens

1 STRUCTURE; 3 HEADS==> THREE MODELS

RES G XXR BLU 15.4 - 30.8 kW

RES G XXR BLU 28 - 43 kW

RES G XXR BLU 40.6 - 51.7 kW

BUrners TRAining CEntre