PV G rid- co n etd I v - Gold Coast Solar Power Solutionsgold-coast-solar-power-solutions.com.au/wp-content/uploads/2016/07/... · PV G rid- co n etd I v 2012~2013 Add: No.558 Gangxing
Post on 30-Apr-2018
214 Views
Preview:
Transcript
Jiangsu Zeversolar New Energy Co., Ltd.
V-2
01
20
04
EN
Cat
alo
gu
e
PV Grid-connected Inverter2012~2013
Add: No.558 Gangxing Road,Economic Development Zone,Yangzhong,China Tel: +86 511 8820 5878Fax: +86 511 8820 5898Web: www.zeversolar.comE-mail: sales@zeversolar.com
Add: Building 9 No.198 Xiangyang Road,Suzhou,ChinaTel: +86 512 6937 0998Fax: +86 512 6937 0630Web: www.zeversolar.comE-mail: sales@zeversolar.com
With High Frequency Transformer
Optional Parts
Contents
Low & Medium Power Inverter
Company Profile
Eversol TLC10K / TLC12K / TLC15K / TLC17K
Eversol TL1500 / TL2000 / TL2500 / TL3000Eversol TL3200 / TL4000 / TL4600 / TL5400
Evershine TL3000 / TL4000 / TL5000 / TL6000 (New)
Eversol HF1000 / HF1500 / HF2000
PMU
Solar Eye
Everplan
Datacenter Portal
Certificate
1 2
Without Transformer
Technical Data
Evercentral TL630K / TL500KEvercentral TL250KEvercentral TL100K / TF100K
High power Grid-connected Inverter
3-4
5-26
27-40
41-46
47-48
49-50
Integrated Mw PV Power Plant System
Evercentral TL1000K
High Power Grid-connected Inverter
7-24
25-26
29-34
35-40
“Jiangsu Zeversolar New Energy Co., Ltd.” is merged by “Jiangsu Eversolar New Energy Co.,
Ltd.” and “Jiangsu ZOF New Energy Ltd.” Zeversolar combines Eversolar’s low and medium
power inverters and ZOF’s high power inverters, in other words, Zeversolar possesses all series
of on-grid photovoltaic inverters from 1.5kW to 1MW. All the inverters can meet the
requirement of different systems, including household roof system, commercial roof system,
large-scale ground PV power plant system, and etc. Meanwhile, Zeversolar has monitoring
products, such as PMU, Solareye, in order to satisfy special monitoring requirements. After
merged, Zeversolar has 400 employees, and by the end of 2011, the production capacity has
been enlarged to 2GW.
3
Company Profile
4
Grid managementDue to the growth of photovoltaic market, it is becoming increasingly important for inverters
to participate in grid management. Zeversolar always focus on medium-voltage research
before, but now more and more safety standard requires inverters to be with the function of
grid management. So Zeversolar develops a new research project of grid management. In
2012, customers would find more and more Zeversolar inverters’ design complies with the
requirement of low-voltage grid.
Advantages of ProductZeversolar inverter varies from 1.5kW to 1MW, and the design is diversified according to the
different customer’s requirements. For example, high conversion efficiency, wide MPPT
voltage, low turn-off voltage, multi-MPPT design, graphical display, one button update,
multiple monitoring mode and so on.
ReliabilityZeversolar never stops improving the quality of products. All Zeversolar inverters must pass
strict test including HALT, ISTA, STRIFE TEST, MTBF/DMTBF, and so on.
MarketThrough many years operation, Zeversolar inverters have been applied in many markets
including Germany, Australia, UK, Greece, France, Spain, Italy, Sweden, Czech, South Africa,
China, and so on.
ServiceFollowing more and more inverters installed at home and abroad, Zeversolar is increasing
service team, in order to provide perfect service and support to customers, which includes but
not limited to power system design support, remote and on-site instruction service, fastest
after-sales service. In addition, Zeversolar has built after-sales offices in Europe and Australia.
About us
Low & Medium Power InverterWithout transformer
85 pcs of TLC12K
"A / A"by Photon
8
1MW project in Erbendorf, Germany
7
Eversol TLC10K /12K /15K /17KPV Grid-connected Inverter
Features:Function of low voltage ride through
Maximum efficiency of 98.2%
Wide range of DC input and MPPT voltage
High protection class:IP65
Low turn-off DC voltage
With two MPP trackers, improve power generation
Comprehensive function of fault detection
Graphical LCD Display
Certificate: VDE-AR-N-4105, VDE0126-1-1,CE,G59/2, etc.
In line with the German BDEW Medium Voltage Directive
25
0~
90
0V
DC
*2
3/N
/PE
,23
0/4
00
V
EMC filter
DC/DC DC/AC EMC filter
Insulationmonitoring
Control and grid monitoring
Circuit Diagram:
Max. PV-generator power [W]Max. DC voltage [V]MPPT voltage range [V]Turn off DC oltage [V]Max. DC current (input A/input B) [A]Number of MPP Max.number of Parallel(A/B)
v
trackers
Power connectionRated AC power [W]Max. AC ower [W]Grid voltage range Grid frequency range Max. current [A]Power factor Harmonic distortion (THD) at rated outputPower consumption at night [W]Power consumption at standby [W]
p[V]
[Hz]
[cos Ø]
Max. efficiencyEuro efficiency MPPT adaptation efficiency
Safety equipmentInternal DC voltage Surge protectionDC Insulation monitoringEarth fault protection Mains monitoring Earth fault current monitoringDC current monitoringEMC BDEW
CE- compliant according to
General dataDimensions (WxHxD) [mm]Weight [kg]Installation environmentMounting informationOperating temperature rangeRelative humidityIP protection type Isolation typeCooling conceptNoise levelLED displayLCD display
Standard warrantyCommuniacation interface
Normative reference
Eff ic iency
DC input data
Output data
Technical Data TLC 10K
0% 20% 40% 60% 80% 100%
Efficiency Curve:100%
98%
96%
94%
92%
90%
88%
86%
O u t p u t P o w e r / R a t e d P o w e r
Co
nv
ers
ion
Effic
ien
cy
450V
500V
600V
640V
700V
Eversol TLC10K / 12K / 15K / 17KTLC TLC TLC
Max. PV-generator power [W]Max. DC oltage [V]MPPT voltage range [V]Turn off DC oltage [V]Max. DC current (input A/input B) [A]
Max.number of Parallel(A/B)
v
v
Number of MPP trackers
Power connection
Harmonic distortion (THD) at rated outputPower consumption at night [W]Power consumption at standby [W]
Rated AC power [W]Max. AC power [W]Grid voltage range [V]Grid frequency range [Hz]Max. current [A]Power factor [cos Ø]
Max. efficiencyEuro efficiency MPPT adaptation efficiency
Safety equipmentInternal DC voltage Surge protectionDC Insulation monitoringEarth fault protection Mains monitoring Earth fault current monitoringDC current monitoringEMC BDEW
CE- compliant according to
General dataDimensions (WxHxD) [mm]Weight [kg]Installation environmentMounting informationOperating temperature rangeRelative humidityIP protection type Isolation typeCooling conceptNoise levelLED displayLCD displayCommuniacation interfaceStandard warranty
Normative reference
Eff ic iency
DC input data
Output data
Technical Data TLC 15KTLC 12K TLC 17K
12500900
270 - 800220
22/112
4\1
15600900
270 - 800220
22/222
3\3
17600900
270 - 800220
22/222
3\3
10400900
270 - 800220
22/112
4\1
3/N/PE,230/400V
0.85 leading...0.85 lagging<3%<0.6 <12
According to AS4777, VDE 0126-1-1,VDE-AR-N 4105,G59/2,Enel Guida,RD1663,CQCAccording to AS4777, VDE 0126-1-1,VDE-AR-N 4105,G59/2,Enel Guida,RD1663,CQC
98.00%97.50%99.50%
Type 3 IntegratedIntegratedIntegratedIntegrated
EN 61000-6-2,Integrated
IntegratedIntegrated
EN 61000-6-1, EN 61000-6-3,EN 61000-6-4
EN 62109, EN 61000-6-2, EN 61000-6-3, EN61000-3-12, EN61000-3-11
500
( )
RS232 / USB /
*720*17550
Indoor and OutdoorWall bracket
-20°C ... +60°C up 45°C derating 0% ~ 98%, no condensationIP 65 according to EN 60529
TransformerlessFan cooling< 50 dB(A)
3800X480 Pixel TFT LCD
RS485 / Wireless(Optional)5years
1000010000
1200012000
16 19.2
3/N/PE,230/400V
<3%<0.6 <12
According to AS4777, VDE 0126-1-1,VDE-AR-N 4105,G59/2,Enel Guida,RD1663,CQCAccording to AS4777, VDE 0126-1-1,VDE-AR-N 4105,G59/2,Enel Guida,RD1663,CQC
0.85 leading...0.85 lagging
1500015000
1700017000
24 25.8
98.20%97.50%99.50%
EN 62109, EN 61000-6-2, EN 61000-6-3, EN61000-3-12, EN61000-3-11
500
( )
RS485 / RS232 / USB / Wireless(Optional)5years
*720*17550
Indoor and OutdoorWall bracket
-20°C ... +60°C up 45°C derating0% ~ 98%, no condensationIP 65 according to EN 60529
TransformerlessFan cooling< 50 dB(A)
3800X480 Pixel TFT LCD
109
Low & Medium Power InverterWithout transformer
Type 3 IntegratedIntegratedIntegratedIntegrated
IntegratedEN 61000-6-2,
Integrated
Integrated
EN 61000-6-1, EN 61000-6-3,EN 61000-6-4
250V
310V
360V
Dual MPP trackers allow more energy harvesting
High performance in the shadow perfect
Wide range of DC input and MPPT voltage
Maximum MPPT efficiency of 99.9%
Perfect protection for safety
Multiple monitor mode
Software updates via USB
Lightweight, easy installation and maintenance
Display optional: 1. Backlight, 16 x 2 Character LCD
2. Graphic LCD display, visible at night
Circuit Diagram:
0% 20% 40% 60% 80% 100%
Efficiency Curve:
100%
98%
96%
94%
92%
90%
88%
86%
O u t p u t P o w e r / R a t e d P o w e r
Co
nv
ers
ion
Effic
ien
cy
PV Grid-connected Inverter
Features:
Evershine TL3000 /4000 /5000 /6000
1211
Low & Medium Power InverterWithout transformer
NEWArrival
11
5~
60
0V
DC
23
0V
/50
Hz
L
N
PE
Grid
Control andgrid monitoring
Insulationmonitoring
EMC
EMC
DC/DCBOOST 1
DC/DCBOOST 2
DC/AC EMC
DC input data
Output data
Technical Data TL3000
Evershine TL TL TL TL3000 / 4000 / 5000 / 6000
TL4000
3200600
125 - 520115
15/151/12
Max. PV-generator power [W]Max. DC oltage [V]MPPT voltage range [V]Turn off DC oltage [V]Max. DC current [A]Number of DC connectionNumber of MPP trackersTurn on power [W]DC switch
v
v
10Optional
4200600
125 - 520115
15/151/12
Power connectionRated AC power [ ]Max. AC ower [ ]Grid voltage range Grid frequency range Rated current [A]Max. current [A]Power factor Harmonic distortion (THD) at rated outputPower consumption at night [W]Power consumption at standby [W]
Wp W
[V][Hz]
[cos Ø]
Single phase30003000
According to VDE-AR-N 4105, ,G83/1,G59/2,ENEL Guida,AS4777, and safty regulation of other Europe countries
UL1741, IEEE1547,IEEE1547.1
13 15
<2%<16
40004000
16 20
<2%<16
Max. efficiencyEuro efficiency MPPT adaptation efficiency
Safety equipment
Eff ic iency97.30%96.50%99.90%
General data
Internal overvoltage protectionDC Insulation monitoringEarth fault protection Mains monitoring Earth fault current monitoringDC current monitoringIslanding protectionSafety requirement
IntegratedIntegratedIntegratedIntegratedIntegratedIntegrated
AFDVDE-AR-N 4105, UL1741,IEEE1547,IEEE1547.1,G59/2, AS4777, ENEL Guida RD1663,CQC,CE,G83/1
Dimensions (WxHxD) [mm]Weight [kg]
Mounting informationOperating temperature rangeRelative humidityIP protection type Isolation typeCooling conceptNoise levelLED displayLCD displayCommunication interfaceStandard warranty
Installation environment
405*480*200
Wall Blacket-25°C ...+60°C up 45°C derating
0% ~ 98%, no condensationIP 65 according to IEC 60529
TransformerlessConvection
< 30 dBA3 and can see clearly 7 m away
Graphic LCD display , visible at nightRS485 / Ethernet(Optional)
5 years
Indoor and Outdoor
( )
Backlight, 16 x 2 Character LCD / USB /
1413
Low & Medium Power InverterWithout transformer
0.95 leading...0.95 lagging
16.5 17
5300600
125 - 520115
15/152/22
10Optional
4600(Germany)/50004600(Germany)/5000
According to VDE-AR-N 4105, ,G83/1,G59/2, ENEL Guida,AS4777, and safty regulation of other Europe countries
UL1741, IEEE1547,IEEE1547.1
22 25
<2%<16
2627
<2%<16
405*480*200
Wall Blacket-25°C ...+60°C up 45°C derating
0% ~ 98%, no condensationIP 65 according to IEC 60529
TransformerlessConvection
< 30 dBA3 and can see clearly 7 m away
Graphic LCD display , visible at night
Indoor and Outdoor
( )
Backlight, 16 x 2 Character LCD / RS485 / USB / Ethernet(Optional)
5 years
6300600
125 - 520115
15/152/22
60006000
Single phase
0.95 leading...0.95 lagging 1 leading...1 lagging
97.30%96.50%99.90%
19 21
DC input data
Output data
Technical Data
Max. PV-generator power [W]Max. DC oltage [V]MPPT voltage range [V]Turn off DC oltage [V]Max. DC current [A]Number of DC connectionNumber of MPP trackersTurn on power [W]DC switch
v
v
Power connectionRated AC power [ ]Max. AC ower [ ]Grid voltage range Grid frequency range Rated current [A]Max. current [A]Power factor Harmonic distortion (THD) at rated outputPower consumption at night [W]Power consumption at standby [W]
Wp W
[V][Hz]
[cos Ø]
Max. efficiencyEuro efficiency MPPT adaptation efficiency
Safety equipment
Eff ic iency
General dataDimensions (WxHxD) [mm]Weight [kg]
Mounting informationOperating temperature rangeRelative humidityIP protection type Isolation typeCooling conceptNoise levelLED displayLCD display
Installation environment
Communication interfaceStandard warranty
TL5000 TL6000
Internal overvoltage protectionDC Insulation monitoringEarth fault protection Mains monitoring Earth fault current monitoringDC current monitoringIslanding protectionSafety requirement
IntegratedIntegratedIntegratedIntegratedIntegratedIntegrated
AFDVDE-AR-N 4105, ,G59/2, AS4777, ENEL Guida RD1663,CQC,CE,G83/1UL174 , IEEE1547,IEEE1547.1
1615
Low & Medium Power InverterWithout transformer
50KW project, Australia25 pcs of TL2000
PV Grid-connected Inverter
Features:
Eversol TL1500 /2000 /2500 /3000
Maximum efficiency of 97.6%
Wide range of DC input and MPPT voltage
Low turn-off DC voltage
High protection class:IP65
Perfect protection function
DC switch improves product reliability
Certificate:G83/1,VDE,AS4777, ENEL Guida, RD1663,CQC
Light and handy, easy for installation and maintenance
DC input data
Output data
Technical Data TL1500
Eversol TL TL TL TL1500 / 2000 / 2500 / 3000
TL2000
Power connectionRated AC power [ ]Max. AC power [ ]Grid voltage range
Grid frequency range
Rated current [A]Max. current [A]Power factor Harmonic distortion (THD) at rated outputPower consumption at night [W]Power consumption at standby [W]
WW
[V]
[Hz]
[cos Ø]
Max. efficiencyEuro efficiency MPPT adaptation efficiency
Safety equipment
Eff ic iency
General data
Max. PV-generator power [W]Max. DC oltage [V]MPPT voltage range [V]Turn off DC oltage [V]Max. DC current [A]Number of DC connectionNumber of MPP trackersTurn on power [W]
v
v
Internal overvoltage protectionDC Insulation monitoringEarth fault protection Mains monitoring Earth fault current monitoringDC current monitoringIslanding protection
Dimensions (WxHxD) [mm]Weight [kg]Installation environmentMounting informationOperating temperature rangeRelative humidityIP protection type Isolation typeCooling conceptNoise levelLED displayLCD displayCommunication interfaceStandard warranty
1800450
125-4501251811
10
Single phase
47.5-50.2 (VDE 0126-1-1)/47-50.5 (G83/1)/49-51 (RD1663)/45-55 (AS4777)/ 49-50 (ENEL Guida)
184-264 (VDE 0126-1-1)/ 207-264 (G83/1)/196-253 (RD1663)/200-270 (AS4777)/184-276(ENEL Guida)
97.60%96.50%99.50%
*414*14815.3
Indoor and outdoorWall bracket
-20°C ... +60°C up 45°C derating0% ~ 98%, no condensationIP 65 according to IEC 60529
TransformerlessConvection
< 40 dBA3
Backlight, 16 x 2 Character LCDRS485 / RS232 / ( )
5 years
360
( )
Wireless Optional
2300500
125 - 4501251811
10
15001650
20002000 (AS4777) /2200(others)
6.5 others)/6.25(AS4777)8.3(others)/8.0(G83/1)
0.99<2%<16
( 8.7(others)/8.3(AS4777)11(others)/10.6(G83/1)
0.99<2%<16
IntegratedIntegratedIntegratedIntegratedIntegratedIntegrated
AFD
DC input data
Output data
Technical Data TL2500 TL3000
Power connection
Harmonic distortion (THD) at rated outputPower consumption at night [W]Power consumption at standby [W]
Rated AC power [W]Max. AC power [W]Grid voltage range [V]
Grid frequency range [Hz]
Rated current [A]Max. current [A]Power factor [cos Ø]
Max. efficiencyEuro efficiency MPPT adaptation efficiency
Safety equipment
Eff ic iency
General data
Max. PV-generator power [W]Max. DC oltage [V]MPPT voltage range [V]Turn off DC oltage [V]Max. DC current [A]Number of DC connectionNumber of MPP trackersTurn on power [W]
v
v
Internal overvoltage protectionDC Insulation monitoringEarth fault protection Mains monitoring Earth fault current monitoringDC current monitoringIslanding protection
Dimensions (WxHxD) [mm]Weight [kg]Installation environmentMounting informationOperating temperature rangeRelative humidityIP protection type Isolation typeCooling conceptNoise levelLED displayLCD display
Communication interfaceStandard warranty
Single phase
97.60%96.50%99.50%
15.6Indoor and outdoor
Wall bracket
0% ~ 98%, no condensationIP 65 according to IEC 60529
TransformerlessConvection
< 40 dBA3
Backlight, 16 x 2 Character LCD
360*414*148
RS485 / RS232 / Wireless(Optional)5 years
25002500
30003000
IntegratedIntegratedIntegratedIntegratedIntegratedIntegrated
AFD
2700500
200-4501251821
10
3300500
200-4501251521
10
207-264(G83/1)
47-50.5 (G83/1)
200-270 (AS4777) / 207-264(G83/1)
45-55(AS4777) / 47-50.5(G83/1)
10.912.1(G83/1)
0.99<2%<16
12.515
0.99<2%<16
12
5~
45
0V
DC
23
0V
/50
Hz
EMC filter
DC/DC DC/AC EMC filter
Insulationmonitoring
Control and grid monitoring
Circuit Diagram:
0% 20% 40% 60% 80% 100%
Efficiency Curve:100%
98%
96%
94%
92%
90%
88%
86%
O u t p u t P o w e r / R a t e d P o w e r
Co
nv
ers
ion
Effic
ien
cy
450V
500V
600V
640V
700V
1817
Low & Medium Power InverterWithout transformer
-20°C ... +60°C(up 40°C derating)-20°C ... +60°C(up 45°C derating)
2019
Low & Medium Power InverterWithout transformer
1Eversol TL4600
stin Asia
Photon test results ranked
65 pcs of TL4600
300KW Project in Munich, Germany
50KW Project, UK
Maximum efficiency of 97.6%, ranks top in Asia
Wide range of DC input and MPPT voltage
High protection class:IP65
Low turn-off DC voltage
With two MPP trackers, improve power generation
Comprehensive function of fault detection
Certificate:G83/1,VDE,AS4777, ENEL Guida, RD1663,CQC
PV Grid-connected Inverter
Features:
Eversol TL3200 /4000 /4600 /5400
2221
Low & Medium Power InverterWithout transformer
20 pcs of TL5400 100KW project100KW Project in Munich, Germany
DC input data
Output data
Technical Data TL3200
Eversol TL TL TL TL3200 / 4000 / 4600 / 5400
TL4000
Power connection
Harmonic distortion (THD) at rated outputPower consumption at night [W]Power consumption at standby [W]
Rated AC power [W]Max. AC power [W]Grid voltage range [V]
Grid frequency range [Hz]
Rated current [A]Max. current [A]Power factor [cos Ø]
Max. efficiencyEuro efficiency MPPT adaptation efficiency
Safety equipment
Eff ic iency
General data
Max. PV-generator power [W]Max. DC oltage [V]MPPT voltage range [V]Turn off DC oltage [V]Max. DC current [A]Number of DC connectionNumber of MPP trackersTurn on power [W]
v
v
Internal overvoltage protectionDC Insulation monitoringEarth fault protection Mains monitoring Earth fault current monitoringDC current monitoringIslanding protection
Single phase
97.60%97.00%99.50%
IntegratedIntegratedIntegratedIntegratedIntegratedIntegrated
AFD
12
5~
55
0V
DC
23
0V
/50
Hz
EMC filter
DC/DC DC/AC EMC filter
Insulationmonitoring
Control and grid monitoring
Circuit Diagram:
0% 20% 40% 60% 80% 100%
Efficiency Curve:100%
98%
96%
94%
92%
90%
88%
86%
O u t p u t P o w e r / R a t e d P o w e r
Co
nv
ers
ion
Effic
ien
cy
450V
500V
600V
640V
700V
3200580
125 - 53012520
1(others) / 2 (AS4777)1
10
(others)/550(AS4777)4200680
125 - 5501252021
10
28003080
36004000
184-264 (VDE 0126-1-1)/ 207-264 (G83/1)/196-253 (RD1663)/200-270 (AS4777)/ 184-276(ENEL Guida)47.5-50.2 (VDE 0126-1-1)/ 47-50.5 (G83/1)/49-51
(RD1663)/ 45-55 (AS4777)/49-51 (ENEL Guida)
207-264 (G83/1)
47-50.5 (G83/1)
12.2 15.4(other)/14.9(G83/1)
0.99<2%<0.2
6
15.6 20(other)/16(G83/1)
0.99<2%<0.2
6
Wall screw-20°C ... +60°C up 40°C derating
0% ~ 98%, no condensationIP 65 according to IEC 60529
Transformerless
< 40 dBA3
Backlight, 16 x 2 Character LCD
344*590*166
Indoor and outdoor
( )
RS485 / RS232 / Wireless(Optional)5 years
Dimensions (WxHxD) [mm]Weight [kg]
Mounting informationOperating temperature rangeRelative humidityIP protection type Isolation typeCooling conceptNoise levelLED displayLCD display
Installation environment
Communication interfaceStandard warranty
DC input data
Output data
Technical Data TL4600 TL5400
Power connection
Harmonic distortion (THD) at rated outputPower consumption at night [W]Power consumption at standby [W]
Rated AC power [W]Max. AC power [W]Grid voltage range [V]
Grid frequency range [Hz]
Rated current [A]Max. current [A]Power factor [cos Ø]
Max. efficiencyEuro efficiency MPPT adaptation efficiency
Safety equipment
Eff ic iency
General data
Max. PV-generator power [W]Max. DC oltage [V]MPPT voltage range [V]Turn off DC oltage [V]Max. DC current [A]Number of DC connectionNumber of MPP trackersTurn on power [W]
v
v
Internal overvoltage protectionDC Insulation monitoringEarth fault protection Mains monitoring Earth fault current monitoringDC current monitoringIslanding protection
Single phase
97.60%97.00%99.50%
IntegratedIntegratedIntegratedIntegratedIntegratedIntegrated
AFD
40004400
46005060
*590*166
Wall screw-20°C ... +60°C up 40°C derating
0% ~ 98%, no condensationIP 65 according to IEC 60529
Transformerless
< 40 dBA3
Backlight, 16 x 2 Character LCD
344
Indoor and outdoor
( )
Fan
RS485 / RS232 / Wireless(Optional)5 years
Dimensions (WxHxD) [mm]Weight [kg]
Mounting informationOperating temperature rangeRelative humidityIP protection type Isolation typeCooling conceptNoise levelLED displayLCD display
Installation environment
Communication interfaceStandard warranty
4600
1252021
10
5400
1252522
10
680(others)/550(AS4777)125-550(others)/125-530(AS4777)
184-264 (VDE 0126-1-1)/ 207-264 (G83/1)/196-253 (RD1663)/200-270 (AS4777)/ 184-276(ENEL Guida)
47.5-50.2 (VDE 0126-1-1)/ 47-50.5 (G83/1)/49-51 (RD1663)/ 45-55 (AS4777)/49-51 (ENEL Guida )
17.4 22(other)/21.3(G59/2)
0.99<2%<0.2
6
20.0 25(other)/24.2(G59/2)
0.99<2%<0.2
6
21.4 23.520.9 21.4
2423
Low & Medium Power InverterWithout transformer
Convection Fan
97.60%96.50%99.50%
Max. efficiencyEuro efficiency MPPT adaptation efficiency
Safety equipment
General data
Eff ic iency
DC input data
Output data
Technical Data
Eversol HF1000/HF1500/HF2000
HF1500
Max. PV-generator power [W]Max. DC oltage [V]MPPT voltage range [V]Turn off DC oltage [V]Max. DC current [A]Nominal DC current [A]Number of DC connectionNumber of MPP trackersTurn on power [W]
v
v
Power connection
Harmonic distortion (THD) at rated outputPower consumption at night [W]Power consumption at standby [W]
Rated AC power [W]Max. AC power [W]Grid voltage range [V] Grid frequency range [Hz]Rated current [A]Max. current [A]Power factor [cos Ø]
20
0~
45
0V
DC
23
0V
/50
Hz
EMC filter
DC/DC DC/AC EMC filter
Insulationmonitoring
Control and grid monitoring
Circuit Diagram:
0% 20% 40% 60% 80% 100%
Efficiency Curve:100%
98%
96%
94%
92%
90%
88%
86%
O u t p u t P o w e r / R a t e d P o w e r
Co
nv
ers
ion
Effic
ien
cy
220V
350V
380V
450V
1800500
200 - 450120
124.4
11
10
(others)/90(G83/1)
(others)/4.5(G83/1)
Internal overvoltage protectionDC Insulation monitoringEarth fault protection Mains monitoring Earth fault current monitoringDC current monitoringIslanding protection
Dimensions (WxHxD) [mm]Weight [kg]
Mounting informationOperating temperature rangeRelative humidityIP protection type Isolation typeCooling conceptNoise levelLED displayLCD display
Installation environment
Communication interfaceStandard warranty
Single phase15001650
6.25(others)/6.5(G83/1)8.250.99<3%<16
IntegratedIntegratedIntegratedIntegratedIntegratedIntegrated
350*370*138 12.5
Wall bracket-20°C ... +60°C(up 45°C derating)
0% ~ 98%, no condensationIP 65 according to IEC 60529
TransformerConvection
< 40 dBA3
Backlight, 16 x 2 Character LCD
Indoor and outdoor
RS485 / USB / Wireless(Optional)5 years
96.00%95.50%99.50%
Single phase20002000
8.4(others)/8.7(G83/1)10
0.99<3%<16
2300500
200 - 450120(others)/90(G83/1)
125.8(others)/6(G83/1)
21
10
HF2000
Low & Medium PowerWith High Frequency Transformer
Inverter
2625
HF1000
1200500
125 - 45070103.511
10
Single phase10001000
4.55
0.99<3%<16
According to AS4777 / G83/1 According to AS4777 / G83/1
NEWArrival
With high frequency isolation
Maximum MPPT efficiency of 99.5%
Wide range of DC input and MPPT voltage
Perfect protection function
High protection class:IP65
Certificate: G83/1, AS4777
PV Grid-connected Inverter
Features:
Eversol HF1000 /HF HF20001500 /
AFI(According to G83/1) AFI(According to G83/1,AS4777)
95.50%95.00%99.50%
96.00%95.50%99.50%
According to G83/1 According to G83/1
PV Grid-connected InverterEvercentral TL1000K
Funct ion of low vol tage r ide throughMaximum eff ic iency of 98.7%MPPT prec is ion of over 99.9%Wide range of DC input and MPPT vol tageCan rea l ize mega watt power d ispatchHigh st rength enc losure for long d istance t ransportat ion and insta l lat ionWith env i ronmenta l test equipment No derat ing below 3000mPerfect protect ion funct ionCert i f icate: CQC, BDEW
Features:
Max. efficiencyEuro efficiency
General data
Eff ic iency
DC input data
Output data
Technical Data TL1000K
Evercentral TL1000K
Max. PV power KWDC voltage range, MPPT VMax. permissible DC voltage VMax. permissible DC current ANumber of DC inputs
[ ][ ]
[ ][ ]
Nominal AC output power KWOperating grid voltage ± 15 % VOperating range, grid frequency HzNominal AC current APower factor cos Harmonic distortion (THD) at rated outputPower consumption at night W
[ ][ ]
[ ][ ]
[ Ø]
[ ]
FeaturesGround fault monitoringEmergency stopPower switch AC sidePower switch DC sideMonitored surge voltage protectors DCMonitored surge voltage protectors AC Monitored surge voltage protectors for auxiliary supply
StandardsCQCLVRT
Dimensions (WxHxD) mmWeight kgInstallation environmentOperating temperature rangeRelative humiditySite altitudeIP protection type Isolation typeCooling conceptlLCD display
[ ][ ]
Communication interface
1100450-850
8802400
24
1000300
50/601950
0.9 leading ... 0.9 lagging <3%<100
>98.70%>98.50%
YesYes
switchswitch with moto
YesYesYes
YesYes
8600*3000*260016000
Outdoor-25°C ...+55°C
0% to 95%, no condensation Up to 3000m without derating
IP54Transformerless
Fan coolingMT6070iH2
RS485 / RS232
45
0~
85
0V
DC
*2
4
3/N
/PE
,30
0V
EMC filter
DC/DC DC/AC EMC filter
Insulationmonitoring
Control and grid monitoring
Circuit Diagram:Efficiency Curve:
0% 20% 40% 60% 80% 100%
100%
98%
96%
94%
92%
90%
88%
86%
O u t p u t P o w e r / R a t e d P o w e r
Co
nv
ers
ion
Effic
ien
cy
450V
500V
600V
650V
700V
High power Grid-connected Inverter
3029
3231
20 of MW Project in Sheyang Jiangsu, China
High power Grid-connected Inverter
The first 20MW integrated project in jiangsu province, Jiangsu Zeversolar provided 500KW Inverters.has received good evaluation from the customer.
3433
10 of MW Project in Sangri Xizang , China
High power Grid-connected Inverter
This project is the first high-altitude 10MW PV Project, Zeversoalr supplied Inverters
PV Grid-connected InverterEvercentral TL630K /TL500K
Function of low voltage ride through
Maximum efficiency of 98.7%
Wide range of MPPT voltage
With 32 bit DSP chip,realize the space vector calculation,has the reactive power compensation ability
With DSP+CPLD framework,fast computational speed
No derating below 3000m
Perfect protection function
Certificate: CQC
In line with the German BDEW Medium Voltage Directive
Features:
Max. efficiencyEuro efficiency
General data
Eff ic iency
DC input data
Output data
Technical Data TL630K
Evercentral TL630K /TL500K
Max. PV power DC voltage range, MPPT Max. permissible DC voltage Max. permissible DC current Number of DC inputs
[KW][V]
[V][A]
Nominal AC output power [KW]Operating grid voltage ± 15 % [V]Operating range, grid frequency [Hz]Nominal AC current [A]Power factor [cos Ø]Harmonic distortion (THD) at rated outputPower consumption at night [W]
FeaturesGround fault monitoringEmergency stopPower switch AC sidePower switch DC sideMonitored surge voltage protectors DCMonitored surge voltage protectors AC Monitored surge voltage protectors for auxiliary supply
StandardsCQCLVRT
Dimensions (WxHxD) mmWeight kgInstallation environmentOperating temperature rangeRelative humiditySite altitudeIP protection type Isolation typeCooling conceptLCD displayCommuniacation interface
[ ][ ]
>98.70%>98.50%
YesYes
switch
YesYesYes
switch
YesYes
700500-850
10001400
14
630315
47-52/57-621155
<3%<100
0.9 leading ... 0.9 lagging
2000*2165*8502000
Indoor-25°C ...+55°C
0% to 95%, no condensation Up to 3000m without derating
IP21Transformerless
Fan coolingMT6070iH2
RS485/Wireless(optional)
45
0~
85
0V
DC
*1
2/1
4
EMC filter
DC/DC DC/AC EMC filter
Insulationmonitoring
Control and grid monitoring
Circuit Diagram:
3/N
/PE
,30
0V
Efficiency Curve:
0% 20% 40% 60% 80% 100%
100%
98%
96%
94%
92%
90%
88%
86%
O u t p u t P o w e r / R a t e d P o w e r
Co
nv
ers
ion
Effic
ien
cy
450V
500V
600V
650V
700V
High power Grid-connected Inverter
3635
TL500K
>98.70%>98.50%
550450-850
8801120
12
500300
50/60965
<3%<100
0.9 leading ... 0.9 lagging
2200*2265*10002100
Indoor-25°C ...+55°C
0% to 95%, no condensation Up to 3000m without derating
IP21Transformerless
Fan coolingMT6070iH2
RS485 / RS232
ArrivalNEWTL630K
YesYes
switch
YesYesYes
switch with moto
YesYes
PV Grid-connected InverterEvercentral TL250K
Function of low voltage ride through
Maximum efficiency of 98.5%
Wide range of MPPT voltage
With 32 bit DSP chip,realize the space vector calculation,has the reactive power compensation ability
With DSP+CPLD framework,fast computational speed
No derating below 3000m
Perfect protection function
Certificate: CQC
In line with the German BDEW Medium Voltage Directive
Features: Efficiency Curve:
0% 20% 40% 60% 80% 100%
100%
98%
96%
94%
92%
90%
88%
86%
O u t p u t P o w e r / R a t e d P o w e r
Co
nv
ers
ion
Effic
ien
cy
450V
500V
600V
650V
700V
45
0~
85
0V
DC
*8
EMC filter
DC/DC DC/AC EMC filter
Insulationmonitoring
Control and grid monitoring
Circuit Diagram:
3/N
/PE
,30
0V
Evercentral TL250K
Max. efficiencyEuro efficiency
General data
Eff ic iency
DC input data
Output data
Technical Data TL250K
Max. PV power DC voltage range, MPPT VMax. permissible DC voltage Max. permissible DC current Number of DC inputs
[KW][ ]
[V][A]
Nominal AC output power [KW]Operating grid voltage ± 15 % [V]Operating range, grid frequency [Hz]Nominal AC current [A]Power factor [cos Ø]Harmonic distortion (THD) at rated outputPower consumption at night [W]
FeaturesGround fault monitoringEmergency stopPower switch AC sidePower switch DC sideMonitored surge voltage protectors DCMonitored surge voltage protectors AC Monitored surge voltage protectors for auxiliary supply
StandardsCQCLVRT
Dimensions (WxHxD) mmWeight kgInstallation environmentOperating temperature rangeRelative humiditySite altitudeIP protection type Isolation typeCooling conceptLCD displayCommuniacation interface
[ ][ ]
>98.50%>97.60%
YesYes
switchswitch with moto
YesYesYes
YesYes
1410*2265*10001200
Indoor-25°C ...+55°C
0% to 95%, no condensation Up to 3000m without derating
IP21Transformerless
Fan coolingMT6070iH2
RS485 / RS232
275450-850
880560
8
250300
50/60485
<3%<100
0.9 leading ... 0.9 lagging
High power Grid-connected Inverter
3837
PV Grid-connected InverterEvercentral TL100K /TF100K
Function of low voltage ride through
Maximum efficiency of 98%
Wide range of MPPT voltage
Easy to maintain:light and handy
No derating below 3000m
Brand new touch screen display
Perfect protection function
Certificate: CGC
In line with the German BDEW Medium Voltage Directive
Features: Efficiency Curve:
0% 20% 40% 60% 80% 100%
100%
98%
96%
94%
92%
90%
88%
86%
O u t p u t P o w e r / R a t e d P o w e r
Co
nv
ers
ion
Effic
ien
cy
450V
500V
600V
650V
700V
Max. efficiencyEuro efficiency
General data
Eff ic iency
DC input data
Output data
Technical Data TL100K
Evercentral TL100K /TF100K
TF100K
Max. PV power DC voltage range, MPPT Max. permissible DC voltage Max. permissible DC current Number of DC inputs
[KW][V]
[V][A]
Nominal AC output power [KW]Operating grid voltage ± 15 % [V]Operating range, grid frequency [Hz]Nominal AC current [A]Power factor [cos Ø]Harmonic distortion (THD) at rated outputPower consumption at night [W]
FeaturesGround fault monitoringEmergency stopPower switch AC sidePower switch DC sideMonitored surge voltage protectors DCMonitored surge voltage protectors AC Monitored surge voltage protectors for auxiliary supply
StandardsCGC
Dimensions (WxHxD) mmWeight kgInstallation environmentOperating temperature rangeRelative humiditySite altitudeIP protection type Isolation typeCooling conceptLCD displayCommuniacation interface
[ ][ ]
YesYes
switchswitch with moto
YesYesYes
Yes
110450-850
880250
5
100300
50/60155
<3%<100
0.97 leading ... 0.97 lagging
>98.00%>97.50%
110450-850
880
5250
100300
50/60155
<3%<100
0.97 leading ... 0.97 lagging
>97.00%>96.40%
1000*2000*800500
Indoor-25°C ...+55°C
0% to 95%, no condensation Up to 3000m without derating
IP21Transformerless
Fan coolingMT6070iH2
RS485/RS232
1000*2000*800600
Indoor-25°C ...+55°C
0% to 95%, no condensation Up to 3000m without derating
IP21TransformerFan coolingMT6070iH2
RS485/RS232
45
0~
85
0V
DC
*8
EMC filter
DC/DC DC/AC EMC filter
Insulationmonitoring
Control and grid monitoring
Circuit Diagram:
3/N
/PE
,30
0V
High power Grid-connected Inverter
4039
CGC
Power Monitoring Unit
Features: A single PMU can monitor 50 inverters at the same time and
meet large-scale monitoring requirement
Can be connected by LAN and realize all monitoring to PMU
Can get comprehensive working-status of the inverter
The data stored in PMU can be easily converted to CSV and TXT format
Inverter can be connected and used directly without any setting
The distance of inverter communication monitoring is up to 1000m
Validity of data storage can be up to 3 years
Constant monitoring at power-failure
Storage capacity
All Ever-solar inverters can be monitored by Solar-Log™.
Electronic data
Solar Eye---Desktop Monitoring DeviceFor home and small commercial PV solar system
Features: Integrated large LCD display
Wireless transfer,
Support Micro SD card storage of generated power
and inverter data faults
Can query and export historical record
Display of generated power and total generated electricity
Display of generating income and CO2 emission
reduced amount
save installation cables and materials,reduce the installation complexity
Technical Specifications:
ItemPower supply
Wireless communication range
Maxim MicroSD capacity support
Wireless Operating frequency
Solar Eye waterproof level
Monitor the max. number of inverter
Max. number of connected Solar Bee
Currency
Error alarm
Operating temperature range
Operating humidity range
Solar Eye specifications tableSpecifications
DC 4.5V/100mA or AA*3 batteries
Max. 100m
4GByte/FAT32 Format
433MHz
IP20
5
5
£, €, $, ¥
LCD display & audible alarm-10~50℃≤80%
ItemPower supply
Wireless communication range
Maxim RS485 length support
Operating temperature range
Max. number of connected Inverter
Operating humidity range
Wireless Operating frequency
Solar Eye waterproof level
Specifications
Inverter power
Max. 100m
Max. 20m
-20~60
5
≤98%
433MHz
IP65
℃
Solar Bee specifications table
Technical Specifications:
Input voltage
Input current
Power consumption
7.5V DC
1A
1W
Storage data
Display LED display
Communication data
RJ45
100m(without any switching device)
RJ45
1000m(without any switching device)
RJ45
50
>3minutes
MiniUSB B(Max. 2 m)
Stucture data
Ethernet
Communication distance(Ethernet)
Connection interface with inverters
Communication distance (RS485)
Connection interface with environment monitoring device
Max. monitoring connected inverters
Record time interval
USB
Product dimensions:181*128.8*31.8
Package dimensions:306*164*68
IP22
Hang on the wall
0.8kg
Dimensions [mm
Protection type
Mounting information
Net weight
]
Environment data
Storage temperature rangeOperating temperature range
-20~+60°C
-10~+40°C
1G(3 years)
6
Optional Parts
4443
Everplan DesignPV Plant Designing & Planning Software
TM
Features New module data can be added
Sunlight of main countries and cities in the world can be found
Detailed information of Ever-solar inverters
Electrical-characteristic matching of modules and inverters
Predict power generation and print into report
Provide line loss computation of single thread
Rich module database
User-friendly Intuitive operation
Graphic display of key PV system data
information
Optional Parts
4645
Datacenter PortalFeaturesThe user can view the operation state and generation data of the PV plant not only on
the web, but only through iphone and Andriod intelligent terminals.
The power data is updated every 10 minutes.
It can show energy saving reduction and customer profitability.
C e r t i f i c a t e
47 48
EversolTL 1500
EversolTL 2000
EversolTL 2500
EversolTL 3000
EversolTL 3200
EversolTL 4000
EversolTL 4600
EversolTL 5400
EversolTLC 10K
EversolTLC 12K
EversolTLC 15K
EversolTLC 17K
EversolHF 1000
EversolHF 1500
EversolHF 2000
EvershineTL 3000
EvershineTL 4000
EvershineTL 5000
EvershineTL 6000
EvercentralTL 1000K
EvercentralTL 630K
EvercentralTL500K
EvercentralTL 250K
EvercentralTL 100K
EvercentralTF 100K
G83/1 & G59/2 SAA VDE4105 ENEL Guida RD1663 CQCCE CSACERTIFICATET Y P E VDE0126
Notes: Available N/A
344mm
59
0m
m
59
0m
m
166mm
16
6m
m
344mm
360mm
41
4m
m
41
4m
m
148mm
360mm
14
8m
m
500mm
72
0m
m
72
0m
m
175mm
500mm
17
5m
m
TL 3200
TL 4000
TL 4600
TL 5400
TL 1500
TL 2000
TL 2500
TL 3000
TLC 10K
TLC 12K
TLC 15K
TLC 17K
Te c h n i c a l D a t a
Single-phase grid-connected
210 pcs / 20’container
336 pcs / 20’container
90 pcs / 20’container
TL 250K
TL 500K
21
65
mm
2000mm
21
65
mm
1000mm
10
00
mm
2000mm
22
65
mm
1410mm2
26
5m
m1000mm
10
00
mm
1410mm
Single-phase grid-connected
Three-phase grid-connectedCentralized grid -
connected inverter
Centralized grid -connected inverter
Te c h n i c a l D a t a
5049
HF 1000
HF 1500
HF 2000
350mm
37
0m
m
138mm
37
0m
m
350mm
13
8m
m
336 pcs / 20’container
String solar inverter
48
0m
m
405mm
480mm
200mm
20
0m
m
405mmTL 3000
TL 4000
TL 5000
TL 6000
PMU
280 pcs / 20’container
Single-phase grid-connected
top related