OSS Mars Retrofit Technology PS - OneSubsea
Post on 12-Feb-2022
4 Views
Preview:
Transcript
APPLICATIONS ■ Leak repair and bypass ■ Flow isolation ■ Separation ■ Sensor replacement ■ High-integrity pressure protection
system (HIPPS) ■ Sand filtering ■ Subsea sampling ■ Multiphase metering ■ Water injection pumping ■ Multiphase boosting
ADVANTAGES ■ New technology adapted for existing fields ■ HSE risk minimized ■ OEM choke supplier qualification retained ■ Existing installation tooling used
where practical ■ Existing well barriers retained under
control of the operator, reducing risk ■ Life of field extended
The OneSubsea portfolio of MARS* multiple application reinjection system includes retrofit technology comprising a patented insert design that replaces a retrievable choke insert. The system creates an access pathway to the production flow, which establishes an intrinsically safe flow path and enables various production, processing, and injection technologies to be easily added at anytime during the life of the field—all without the need to modify the infrastructure or field architecture.
A universal interface that enables fitting any process to any well at any time during the field’s life can save considerable costs by reducing infrastructure retrieval, modification and repair operations, and deferred production. The modularity of the MARS system helps operators increase revenue through optimized production and reservoir management.
Retrofit TechnologyMARS multiple application reinjection system configurations
MARS system retrofit process module.
onesubsea.slb.com/mars
*Mark of SchlumbergerOther company, product, and service names are the properties of their respective owners.Copyright © 2017 Schlumberger. All rights reserved. 17-OSS-287228
MARS System Retrofit Technology Track Record
Application Multiphase flowmetering
Location Gulf of Mexico
Working presssure, psi [MPa] 15,000 [103.4]
Working temperature, degF [degC] –20 to 300 [−29 to 149]
Water depth, ft [m] 5,580 [1,700]
Application Well boosting
Location Gulf of Mexico
Working presssure, psi [MPa] 5,000 [34.5]
Working temperature, degF [degC] –20 to 180 [−29 to 82]
Water depth, ft [m] 5,580 [1,700]
Application Pressure and temperature sensor replacement
Location UK
Working presssure, psi [MPa] 5,000 [34.5]
Working temperature, degF [degC] –4 to 176 [−20 to 80]
Water depth, ft [m] 1,640 [500]
Application Gas lift inlet reorientation
Location UK
Working presssure, psi [MPa] 5,000 [34.5]
Working temperature, degF [degC] –20 to 250 [−29 to 121]
Water depth, ft [m] 330 [100]
Application Flushing spool adapter
Location Trinidad
Working presssure, psi [MPa] 10,000 [68.9]
Working temperature, degF [degC] 64 to 100 [18 to 38]
Water depth, ft [m] 360 [110]
Application Leak bypass
Location Tunisia
Working presssure, psi [MPa] 7,500 [51.7]
Working temperature, degF [degC] 36 to 311 [2 to 155]
Water depth, ft [m] 330 [100]
Retrofit Technology