MEETING TC 4-15 “Road Lighting Calculations, Test Data and Measurement” 16 May 2005 / Leon.

Post on 14-Dec-2015

215 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

Transcript

MEETING

TC 4-15

“Road Lighting Calculations,

Test Data and Measurement”

16 May 2005 / Leon

STEPS

1. Selection of the right luminaire from I-Tables that is suitable

for your computer program.

2. Comparison between R3 table of your own and in the CD.

3. Determination of calculation field, calculation points and

observer position according to CIE 30.2.

4. Calculation of Illuminance (E) and Luminance (L) for 7

situations of lighting arragements. (Maintanance factor = 1)

TC 4-15

“Road Lighting Caculations, Test Data and Measurement”

16 May 2005 / Leon

TC 4-15

“Road Lighting Caculations, Test Data and Measurement”

16 May 2005 / Leon

STEPS

1. Selection of the right luminaire from I-Tables that is suitable

for your computer program.

2. Comparison between R3 table of your own and in the CD.

3. Determination of calculation field, calculation points and

observer position according to CIE 30.2.

4. Calculation of Illuminance (E) and Luminance (L) for 7

situations of lighting arragements. (Maintanance factor = 1)

I - Tables

TC 4-15

“Road Lighting Caculations, Test Data and Measurement”

16 May 2005 / Leon

STEPS

1. Selection of the right luminaire from I-Tables that is suitable

for your computer program.

2. Comparison between R3 table of your own and in the CD.

3. Determination of calculation field, calculation points and

observer position according to CIE 30.2.

4. Calculation of Illuminance (E) and Luminance (L) for 7

situations of lighting arragements. (Maintanance factor = 1)

Road Surface

Classification

Table

TC 4-15

“Road Lighting Caculations, Test Data and Measurement”

16 May 2005 / Leon

STEPS

1. Selection of the right luminaire from I-Tables that is suitable

for your computer program.

2. Comparison between R3 table of your own and in the CD.

3. Determination of calculation field, calculation points and

observer position according to CIE 30.2.

4. Calculation of Illuminance (E) and Luminance (L) for 7

situations of lighting arragements. (Maintanance factor = 1)

TC 4-15

“Road Lighting Caculations, Test Data and Measurement”

16 May 2005 / Leon

TC 4-15

“Road Lighting Caculations, Test Data and Measurement”

16 May 2005 / Leon

STEPS

1. Selection of the right luminaire from I-Tables that is suitable

for your computer program.

2. Comparison between R3 table of your own and in the CD.

3. Determination of calculation field, calculation points and

observer position according to CIE 30.2.

4. Calculation of Illuminance (E) and Luminance (L) for 7

situations of lighting arragements. (Maintanance factor = 1)

Lighting Arrangement : Single sided “left”

Spacing : 20 m

Road width : 10 m

Number of lane : 2

Montage height : 4 m

Overhang : 2 m

Tilt angle : 0°

Light source : 24 W / 1800 lm / CFL

Lighting Arragement : Straggered

Spacing : 20 m

Road width : 10 m

Number of lane : 2

Montage height : 4 m

Overhang : 2 m

Tilt angle : 0°

Light source : 24 W / 1800 lm / CFL

Lighting Arragement : Single sided “left”

Spacing : 45 m

Road width : 7.5 m

Number of lane : 2

Montage height : 10 m

Overhang : 0 m

Tilt angle : 5°

Light source : 100 W / 10500 lm High Pressure Sodium L.

Lighting Arragement : Staggered

Spacing : 35 m

Road width : 7 m

Number of lane : 2

Montage height : 8 m

Overhang : 0 m

Tilt angle : 5°

Light source : 100 W / 10500 lm High Pressure Sodium L.

Lighting Arragement : Opposite (with 1.5 m of central reservation)

Spacing : 54 m

Road width : 10.5 m

Number of lane : 2

Montage height : 12 m

Overhang : 0 m

Tilt angle : 5°

Light source : 100 W / 10500 lm / HPS

Lighting Arragement : Central, twin brackets

Spacing : 75 m

Road width : 7 m

Number of lane : 2

Montage height : 18 m

Overhang : 0 m

Tilt angle : 5°

Light source : 250 W / 32500 lm / HPS

Lighting Arragement : Single sided “left”

Spacing : 40 m

Road width : 8 m

Number of lane : 2

Montage height : 10 m

Overhang : 0 m

Tilt angle : 5°

Light source : 90 W / 13000 lm Low Pressure Sodium L.

Calibration Intervals for Luminance and Illuminance Values

TC 4-15

“Road Lighting Caculations, Test Data and Measurement”

16 May 2005 / Leon

TC 4-15

“Road Lighting Caculations, Test Data and Measurement”

16 May 2005 / Leon

The results of Calculations According to CIE 30.2

In the (c;) system of coordinates, luminous intensities will be required at the

angular intervals stated below.

For all luminaires the angular intervals in elevation () should at most be 2.5

from 0° to 90° plus the permissible maximum field angle of elevation minus

the measurement angle of elevation, for the luminaire. In azimuth the

intervals can be varied according to the symmetry of the light distribution

from the luminaires as follows:

- Luminaires with no symmetry about c = 0° – 180° plane; the

intervals should at most be 5°, starting at 0°, when the luminaire is in

its measurement angle of elevation and ending at 355°.

TC 4-15

“Road Lighting Caculations, Test Data and Measurement”

16 May 2005 / Leon

Following statements take part in CIE 140 (page: 5);

I-table of road lighting luminaire with no symmetry light distribution

should be given according to those definitions.

TC 4-15

“Road Lighting Caculations, Test Data and Measurement”

16 May 2005 / Leon

TC 4-15

“Road Lighting Caculations, Test Data and Measurement”

16 May 2005 / Leon

Road Surface Reflection Data

TC 4-15

“Road Lighting Caculations, Test Data and Measurement”

16 May 2005 / Leon

Position of Calculation Field According to CIE 140

TC 4-15

“Road Lighting Caculations, Test Data and Measurement”

16 May 2005 / Leon

The results of Calculations According to CIE 140

According to CIE 140, the observer’s eye height 1.5 m above road level, is

positioned transversely a quarter of road width from the carriageway edge,

and longitudinally at a distances in meters of 2.75 (mounting height: 1.5) in

front of the field of calculation.

In EN13201 Part: 3, it is stated that “the observer’s eye, is positioned in

the centre line of each lane in turn” by keeping all other parts same.

TC 4-15

“Road Lighting Caculations, Test Data and Measurement”

16 May 2005 / Leon

TC 4-15

“Road Lighting Caculations, Test Data and Measurement”

16 May 2005 / Leon

The results of Calculations According to EN 13201

top related