Actuator with spring return
5 Nm
20 Nm
For the application with
Fire dampers
Smoke dampers
ACTUATOR FOR DAMPERS
F ire & Smoke Protection
GRUNER the f r iendly a
l te rna t i ve
General overview fire & smoke protection
Summary: Actuators for fire & smoke protection
Technical characteristics, Type 229, 5 Nm
Technical characteristics, Type 239, 20 NmYour way to Gruner
Content:
2
3
4 - 7
8 - 1112
Page:
8/3/2019 Gruner D Fire-And-Smoke En
2/12
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: info@gruner.de
20/06 FSOE Copyright by Gruner AG Technical changes are reserved
GENERAL OVERVIEW: FIRE & SMOKE PROTECTION
Applications
= Standard
= Optional
Type
Spring Return
Torque (Actuator)
Torque (Spring)
Angle of Rotation
Control
On/Off
Power Supply
24 VAC/DC
230 VAC
Options
Auxiliary switch(es)
Thermal Tripping Device
(72C)
Thermal Tripping Device
for Duct Mounting (72C)
229
5 Nm (ca. 1 m2)
4 Nm
100
239
20 Nm (ca. 4 m2)
15 Nm
100
Fire Protection
2
Motorised control of fire and smoke dampers in
HVAC systems.
All actuators correspond to the DIN-VDE standards
and CE guidelines.
8/3/2019 Gruner D Fire-And-Smoke En
3/12
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: info@gruner.de
16/07 FSOE Copyright by Gruner AG Technical changes are reserved
SUMMARY: ACTUATORS FOR FIRE & SMOKE PROTECTION
Type
Torque (Actuator)
Torque (Spring)
On/Off Control
Angle of Rotation
Power Supply
24 VAC/DC
230 VAC
Options
Thernal Tripping Device
(72C)
Thernal Tripping Device
for Duct Mounting (72C)
Auxiliary switch(es)
Page
5 Nm
4 Nm
100
4
5 Nm
4 Nm
100
4
5 Nm
4 Nm
100
6
229-0
24-05-S2
229TA
-024
-05-S2
229-2
30-05-S2
= Standard
= Optional
3
Actuators typ 239 dispose of the manual override option by crank. Actuators according to US standard available upon demand.
5 Nm
4 Nm
100
6
229TA
-230
-05-S2
239-02
4-20
-S2
20 Nm
15 Nm
100
8
239T-0
24-20-S2
20 Nm
15 Nm
100
8
239TA
-024
-20-S2
20 Nm
15 Nm
100
8
239-23
0-20
-S2
20 Nm
15 Nm
100
10
239T-2
30-20-S2
20 Nm
15 Nm
100
10
239TA
-230
-20-S2
20 Nm
15 Nm
100
10
Important Note
The modification and mounting of the actuator to the fire damper is made by the manufacturer of the damper. For this reason the spring-return actuatoris only supplied directly to manufacturers of fire dampers. The manufacturer then bears overall responsibility for proper functioning of the damper.
8/3/2019 Gruner D Fire-And-Smoke En
4/12
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: info@gruner.de
16/07 FSOE Copyright by Gruner AG Technical changes are reserved
229-024-05-S2, 229TA-024-05-S2
229-024-05-S2
1 2 3
S1
4 5 6
S2
BUBN
229TA-024-05-S2
Applications
1 2 3
S1
4 5 6
S2
BUBN
TF1 TF2
TA
Connection scheme Connection scheme
To regulate fire and smoke dampers in HVAC
systems:
Form-locking steel drive
Torque 5 Nm / 4 Nm
Angle of rotation 100
Hold safe position in case of high temperature
no manual operation and position fixing
reliable safe postion
Electromagnetic compatibility controlled
4
Technical Characteristics
Control
Connecting voltage
Power consumption
Transformer sizing
Angle of rotation
Direction of rotation
Running time (90)
Torque
Auxiliary switches
Switching power Auxiliary switches
Connection
Safety class
Protection
Dimensions
Ambient temperature
Maintenance
CE
Weight
On/Off
24 VAC (50/60 Hz) / DC 20%
Motion: 5.0 W / Power safe mode: 3.0 W
6.5 VA
100 (-5...+95)
can be selected by mounting back to front
Actuator: < 40...75 s / Spring: < 20 s
Actuator: 5 Nm / Spring: 4 Nm
2, position fixed to 5 and 80
250 VAC / 5.0 (2.5) A, change-over switch
Cable 900 mm / 0.75 mm2
III
IP54 (Cable downwards)
158 x 66 x 61 mm
-30C...+50C
maintenance-free
73/23/EWG, 89/336/EWG
1,100 g
8/3/2019 Gruner D Fire-And-Smoke En
5/12
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: info@gruner.de
16/07 FSOE Copyright by Gruner AG Technical changes are reserved
229-024-05-S2, 229TA-024-05-S2
Technical drawing
BU,BN
TA
1,2,3,4,5,6
66.001.00
93.000.50
157.001.00
R65.00
R11.00
48.5082.50
11.00
6.00
52.00
R2.00
12.20
12.20
,8
,2
0
,4
,6
1
61.001.00
12.00
66.00
2.00
2
.00
13.00
13.00
229-024-05-S2
5
Fixing of the shaft
Concentric form locking shaft: 8...12 mm
Thermal tripping devices (Fig. 1 + 2)
Auxiliary switches
The actuator has two position fixed auxiliary switches for indicating the damper postion. The position of
the damper can be read on the scale on front of the actuator.
Self test
Duct temperature
Ambient temperature
If 72C are reached the actuator turns the damper back to its safe position.
Version
TA
Yes
Yes
Yes
66.001.00
2.00
27.60
9.00
40.00
50.00
50.00
2.8...3
20.00
20.00
107.002.00
2.8...3
9.5...10
2 Thermal tripping device TA
1
8/3/2019 Gruner D Fire-And-Smoke En
6/12
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: info@gruner.de
16/07 FSOE Copyright by Gruner AG Technical changes are reserved
229-230-05-S2, 229TA-230-05-S2
229-230-05-S2
1 2 3
S1
4 5 6
S2
BUBN
N
L
229TA-230-05-S2
Applications
1 2 3
S1
4 5 6
S2
BUBN
TF1 TF2
TA
N
L
Connection scheme Connection scheme
To regulate fire and smoke dampers in HVAC
systems:
Form-locking steel drive
Torque 5 Nm / 4 Nm
Angle of rotation 100
Hold safe position in case of high temperature
no manual operation and position fixing
reliable safe postion
Electromagnetic compatibility controlled
6
Technical Characteristics
Control
Connecting voltage
Power consumption
Transformer sizing
Angle of rotation
Direction of rotation
Running time (90)
Torque
Auxiliary switches
Switching power Auxiliary switches
Connection
Safety class
Protection
Dimensions
Ambient temperature
Maintenance
CE
Weight
On/Off
230 VAC (50/60 Hz) 15%
Motion: 5.0 W / Power safe mode: 2.5 W
5.5 VA
100 (-5...+95)
can be selected by mounting back to front
Actuator: < 40...75 s / Spring: < 20 s
Actuator: 5 Nm / Spring: 4 Nm
2, position fixed to 5 and 80
250 VAC / 5.0 (2.5) A, change-over switch
Cable 900 mm / 0.75 mm2
II
IP54 (Cable downwards)
158 x 66 x 61 mm
-30C...+50C
maintenance-free
73/23/EWG, 89/336/EWG
1,100 g
8/3/2019 Gruner D Fire-And-Smoke En
7/12
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: info@gruner.de
16/07 FSOE Copyright by Gruner AG Technical changes are reserved
229-230-05-S2, 229TA-230-05-S2
Technical drawing
BU,BN
TA
1,2,3,4,5,6
66.001.00
93.000.50
157.001.00
R65.00
R11.00
48.5082.50
11.00
6.00
52.00
R2.00
12.20
12.20
,8
,2
0
,4
,6
1
61.001.00
12.00
66.00
2.00
2
.00
13.00
13.00
229-230-05-S2
7
Fixing of the shaft
Concentric form locking shaft: 8...12 mm
Thermal tripping devices (Fig. 1 + 2)
Auxiliary switches
The actuator has two position fixed auxiliary switches for indicating the damper postion. The position of
the damper can be read on the scale on front of the actuator.
Self test
Duct temperature
Ambient temperature
If 72C are reached the actuator turns the damper back to its safe position.
Version
TA
Yes
Yes
Yes
66.001.00
2.00
27.60
9.00
40.00
50.00
50.00
2.8...3
20.00
20.00
107.002.00
2.8...3
9.5...10
2 Thermal tripping device TA
1
8/3/2019 Gruner D Fire-And-Smoke En
8/12
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: info@gruner.de
16/07 FSOE Copyright by Gruner AG Technical changes are reserved
239-024-20-S2, 239T-024-20-S2, 239TA-024-20-S2
239-024-20-S2
1 2 3
S1
4 5 6
S2
BUBN
239T-024-20-S2
Applications
1 2 3
S1
4 5 6
S2
BUBN
TF1
T
239TA-024-20-S2
1 2 3
S1
4 5 6
S2
BUBN
TF1 TF2
TA
Connection scheme Connection scheme Connection scheme
To regulate fire and smoke dampers in HVAC
systems:
Form-locking steel drive
Torque 20 Nm / 15 Nm
Angle of rotation 100
Hold safe position in case of high temperature
manual operation and position fixing
reliable safe postion
Electromagnetic compatibility controlled
8
Technical Characteristics
Control
Connecting voltage
Power consumption
Transformer sizing
Angle of rotation
Direction of rotation
Running time (90)
Torque
Auxiliary switches
Switching power Auxiliary switches
Connection
Safety class
Protection
Dimensions
Ambient temperature
Maintenance
CE
Weight
On/Off
24 VAC (50/60 Hz) / DC 20%
Motion: 6.5 W / Power safe mode: 4,0 W
10 VA
100 (-5...+95)
can be selected by mounting back to front
Actuator: 150 s / Spring: < 20 s
Actuator: 20 Nm / Spring: 15 Nm
2, position fixed to 5 and 80
250 VAC / 5.0 (2.5) A, change-over switch
Cable 900 mm / 0.75 mm2
III
IP54 (Cable downwards)
250 x 98 x 58 mm
-30C...+50C
maintenance-free
73/23/EWG, 89/336/EWG
2,500 g
8/3/2019 Gruner D Fire-And-Smoke En
9/12
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: info@gruner.de
16/07 FSOE Copyright by Gruner AG Technical changes are reserved
239-024-20-S2, 239T-024-20-S2, 239TA-024-20-S2
Technical drawing
149
250
10
365
67
98
80
6(6x)
R12
58
2
2
43
15
24
5
80
Motor
S1, S2
1, 2, 3, 4, 5, 6
bl,br
27
239-024-20-S2
9
Fixing of the shaft
Concentric form locking shaft: 8...12 mm
Auxiliary switches
The actuator has two position fixed auxiliary switches for indicating the damper postion. The position of
the damper can be read on the scale on front of the actuator.
66.001.00
2.00
27.60
9.00
40.00
50.00
50.00
2.8...3
20.00
20.00
107.002.00
2.8...3
9.5...10
2 Thermal tripping device TA
Thermal tripping devices (Fig. 1 + 2)
Self test
Duct temperature
Ambient temperature
If 72C are reached the actuator turns the damper back to its safe position.
Version
TA
Yes
Yes
Yes
Version
T
No
No
Yes
1
8/3/2019 Gruner D Fire-And-Smoke En
10/12
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: info@gruner.de
16/07 FSOE Copyright by Gruner AG Technical changes are reserved
239-230-20-S2, 239T-230-20-S2, 239TA-230-20-S2
239-230-20-S2
1 2 3
S1
4 5 6
S2
BUBN
N
L
239T-230-20-S2
Applications
1 2 3
S1
4 5 6
S2
BUBN
TF1
T
N
L
239TA-230-20-S2
1 2 3
S1
4 5 6
S2
BUBN
TF1 TF2
TA
N
L
Connection scheme Connection scheme Connection scheme
To regulate fire and smoke dampers in HVAC
systems:
Form-locking steel drive
Torque 20 Nm / 15 Nm
Angle of rotation 100
Hold safe position in case of high temperature
manual operation and position fixing
reliable safe postion
Electromagnetic compatibility controlled
0
Technical Characteristics
Control
Connecting voltage
Power consumption
Transformer sizing
Angle of rotation
Direction of rotation
Running time (90)
Torque
Auxiliary switches
Switching power Auxiliary switches
Connection
Safety class
Protection
Dimensions
Ambient temperature
Maintenance
CE
Weight
On/Off
230 VAC (50/60 Hz) 15%
Motion: 9.0 W / Power safe mode: 7,0 W
10.0 VA
100 (-5...+95)
can be selected by mounting back to front
Actuator: 150 s / Spring: < 20 s
Actuator: 20 Nm / Spring: 15 Nm
2, position fixed to 5 and 80
250 VAC / 5.0 (2.5) A, change-over switch
Cable 900 mm / 0.75 mm2
II
IP54 (Cable downwards)
250 x 98 x 58 mm
-30C...+50C
maintenance-free
73/23/EWG, 89/336/EWG
2,500 g
8/3/2019 Gruner D Fire-And-Smoke En
11/12
GRUNER AGPF 1149, D-78560 Wehingen
Tel. (++49) 74 26 / 948 - 0Fax (++49) 74 26 / 948 - 200
http://www.gruner.deE-Mail: info@gruner.de
16/07 FSOE Copyright by Gruner AG Technical changes are reserved
239-230-20-S2, 239T-230-20-S2, 239TA-230-20-S2
Technical drawing
149
250
10
365
67
98
80
6(6x)
R12
58
2
2
43
15
24
5
80
Motor
S1, S2
1, 2, 3, 4, 5, 6
bl,br
27
239-230-20-S2
11
Fixing of the shaft
Concentric form locking shaft: 8...12 mm
Thermal tripping devices (Fig. 1 + 2)
Auxiliary switches
The actuator has two position fixed auxiliary switches for indicating the damper postion. The position of
the damper can be read on the scale on front of the actuator.
Self test
Duct temperature
Ambient temperature
If 72C are reached the actuator turns the damper back to its safe position.
Version
TA
Yes
Yes
Yes
66.001.00
2.00
27.60
9.00
40.00
50.00
50.00
2.8...3
20.00
20.00
107.002.00
2.8...3
9.5...10
2 Thermal tripping device TA
Version
T
No
No
Yes
1
8/3/2019 Gruner D Fire-And-Smoke En
12/12
GRUNER AGPF 1149 D 78560 W hi
Tel. (++49) 74 26 / 948 - 0F ( 49) 74 26 / 948 200
http://www.gruner.deE M il i f @ d
YOUR WAY TO GRUNER
Mnchen
Stut tgart
Zrich
Singen
Freudenstadt
Wehingen
Offenburg
Strasbourg
Schramberg
Karlsruhe
A81
N3N1
Basel
34
A8
B1 4
B2 7
Donaueschingen
B2 7
Bal ingen
Tuttl ingen
Spaichingen
B3 3A5
Rottweil
Aldingen
Gosheim
Schmberg
DenkingenFritt l ingen
Freiburg
B3 1
top related