Software Description
Document No. Designation Revision Issue
F-07868-00016-SB log-files download SD-card 1.5 10. 02.2015
Name: ba.marquardt 1/12
Date: 01.04.2014
Hoppe Marine GmbH Kieler Straße 318 22525 Hamburg Germany Tel. +49-40-561949-0 Fax +49-40-561949-99 info@hoppe-marine.com www.hoppe-marine.com
Download of SD-card log-files and software updates
Project: FLUME® Stabilization System Document: F-07868-00016-SB.doc Strictly Confidential This document contains confidential and proprietary information of Hoppe Marine GmbH. Any reproduction, disclosure, or use in whole or in par t is expressly prohibited, except as may be specifically authorized by prior written agreement or permission.
eçééÉ=eçééÉ=eçééÉ=eçééÉ=j~êáåÉj~êáåÉj~êáåÉj~êáåÉ=
Software Description
Document No. Designation Revision Issue
F-07868-00016-SB log-files download SD-card 1.5 10. 02.2015
Name: ba.marquardt 2/12
Date: 01.04.2014
Rev. Status Date Description of Change Issued by A pproved by
1.1 Created 04/04/2014 Created S.Winkler S.Winkler
1.2 - 02/12/2014 Update system parameter added Ba.Marquardt Ba.Marquardt
eçééÉ=eçééÉ=eçééÉ=eçééÉ=j~êáåÉj~êáåÉj~êáåÉj~êáåÉ=
Software Description
Document No. Designation Revision Issue
F-07868-00016-SB log-files download SD-card 1.5 10. 02.2015
Name: ba.marquardt 3/12
Date: 01.04.2014
1 General Description
The FLUME® Stabilization System is equipped with a monitoring and control display unit located in the wheel house. The display unit - called HOMIP - has one SD-card access connection which is located on the side of the unit as shown in the figure below. Else, it has 2 Ethernet ports and 2 USB ports
Display Unit HOMIP
Access Connections
2 SD Card Access
2.1 Direct SD Card Access
The log-files are located on the SD-card and can be accessed through the following steps: [A] CAUTION: Power of HOMIP PLC needs to be turned off before SD-card can be removed. If
not SD-card might be damaged and data files might be lost. To make the system powerless switch off all fuses in the main cabinet. Alternatively you can unplug the green power plug directly at the HOMIP. Both possibilities are indicated in the following pictures
eçééÉ=eçééÉ=eçééÉ=eçééÉ=j~êáåÉj~êáåÉj~êáåÉj~êáåÉ=
Software Description
Document No. Designation Revision Issue
F-07868-00016-SB log-files download SD-card 1.5 10. 02.2015
Name: ba.marquardt 4/12
Date: 01.04.2014
[B] The SD-card access connection is located on the top-side at the back of the HOMIP. [C] The SD-card can be simply removed by pushing gently in the direction of the access
connection. [D] The log-files are located in a folder in the root directory of the SD-card. They are stored in
different types of subfolders for each tank of the system installed and for the inertial measurement system. Every day a new set of log-files is saved in a monthly folder and every month new subfolders are created. Depending on the number of tanks, the files are stored in the following notation:
a. TF_log_HOS1-yyyy-mm\ TF_log_HOS1-yyyy-mm-dd.log (inertial measurement of roll) b. TF_log_TK1-yyyy-mm\ TF_log_TK1-yyyy-mm-dd.log (parameters tank 1) c. TF_log_TK2-yyyy-mm\ TF_log_TK2-yyyy-mm-dd.log (parameters tank 2) d. TF_log_TK3-yyyy-mm\ TF_log_TK3-yyyy-mm-dd.log (parameters tank 3) e. …
[E] Copy all folders including text files to an alternative storage medium and provide the files to Hoppe Marine.
[F] After successful copying of the files please insert empty SD-card into the HOMIP. [G] The power off the HOMIP can be switched back on and the log-function will proceed
automatically.
eçééÉ=eçééÉ=eçééÉ=eçééÉ=j~êáåÉj~êáåÉj~êáåÉj~êáåÉ=
Software Description
Document No. Designation Revision Issue
F-07868-00016-SB log-files download SD-card 1.5 10. 02.2015
Name: ba.marquardt 5/12
Date: 01.04.2014
2.2 Remote Access to SD Card
Another possibility to access the files on the SD card is possible from the Main Cabinet. In case when the Bridge PLC is difficult to reach for example, it might be the easier way to download the data via a patch cable.
1. Change IP address of your Computer, in order to be integrated in the “Flume network”. (See section Error! Reference source not found. in F-07868-00027-SB, if you do not know exactly how to change the IP adress)
2. Connect patch cable to Ethernet switch in the main cabinet
3. Open a normal internet Browser and type in the IP address of the PLC (HOMIP):
192.168.2.101
4. The following page will be displayed:
eçééÉ=eçééÉ=eçééÉ=eçééÉ=j~êáåÉj~êáåÉj~êáåÉj~êáåÉ=
Software Description
Document No. Designation Revision Issue
F-07868-00016-SB log-files download SD-card 1.5 10. 02.2015
Name: ba.marquardt 6/12
Date: 01.04.2014
5. From this page you can access the files stored on the SD-card by choosing the link “Log Files on SD-Card”.
3 Software update and parameters safe and restore
This section describes how to save and restore parameters and how to update the Hoppe Marine PLC, HOMIP. For information of the software installed at the moment, press on the “FLUME” logo on the start screen. Software update files and parameter files for the updates have to be installed on a USB stick. The files have to be installed directly on the stick (root directory) and not in any folders. Otherwise, the files are not accessible by the PLC. Before any update of software or parameters is possible, this USB stick must be connected to the HOMIP PLC. Use the USB ports (port 2) below the display unit, to connect the USB device.
Insert the USB-stick into the middle slot (2) at HOMIP
3.1 Software Update (Select File)
Before making a software update, it is recommended to save a parameter file on an USB stick -
Section 3.3. If any settings are getting lost during the software update, you can restore them easily
be reloading this parameter file.
eçééÉ=eçééÉ=eçééÉ=eçééÉ=j~êáåÉj~êáåÉj~êáåÉj~êáåÉ=
Software Description
Document No. Designation Revision Issue
F-07868-00016-SB log-files download SD-card 1.5 10. 02.2015
Name: ba.marquardt 7/12
Date: 01.04.2014
1. Start Screen
This image will appear on the touch screen display once
the system has booted. Pressing the Menu button on the
start screen will bring up the Main Menu.
2. Main Menu
Pressing the System button will bring up the System
Service menu. However, before reaching the system
service menu you will have to enter a PIN
3. PIN Access
For the System menu the PIN has been set to 3333 for the
security level 3. Press Enter button. (For security level 4
press 4444, and so on.)
4. System Service
Pressing the update button will bring up a list of available
software updates stored in the root path of the USB-
device.
eçééÉ=eçééÉ=eçééÉ=eçééÉ=j~êáåÉj~êáåÉj~êáåÉj~êáåÉ=
Software Description
Document No. Designation Revision Issue
F-07868-00016-SB log-files download SD-card 1.5 10. 02.2015
Name: ba.marquardt 8/12
Date: 01.04.2014
5. Available Software Updates
All software updates, stored on the USB stick should be
visible in a list now. Highlight the desired file and press the
enter key to upload the software update from the
USB-device.
6. System Reboot
After pressing the enter key the system will automatically reboot and install the new
software. The system parameters (e.g. operational liquid level graph, liquid density settings, zero
settings pressure sensor, etc.) remain unchanged. Anyway, please check the parameters after
the update.
Note: Before physically disconnecting the USB-device form the HOMIP be sure to Release USB .
The command Release USB can be found under the System Service menu. (Please see last
section of this document)
3.2 Read Parameter Files
1. Start Screen
This image will appear on the touch screen display once
the system has booted. Pressing the Menu button on the
start screen will bring up the Main Menu.
FSxxxxxxAx.tgz
eçééÉ=eçééÉ=eçééÉ=eçééÉ=j~êáåÉj~êáåÉj~êáåÉj~êáåÉ=
Software Description
Document No. Designation Revision Issue
F-07868-00016-SB log-files download SD-card 1.5 10. 02.2015
Name: ba.marquardt 9/12
Date: 01.04.2014
2. Main Menu
Pressing the System button will bring up the System
Service menu.
3. System Service
Pressing the Parameter button will bring up the
Parameter menu.
4. Parameter Menu
Press Load from USB to read an existing parameter file
from USB-device. The name of a parameter file has the
notation:
xxxxx_xxxxx_TF_TKX_dd.mm-xxxxxx-hhmm.par
Chose the desired file from a list to load the parameters
into the system.
Note: Before physically disconnecting the USB-device form the HOMIP be sure to Release USB .
The command Release USB can be found under the System Service menu. (Please see last
section of this document)
eçééÉ=eçééÉ=eçééÉ=eçééÉ=j~êáåÉj~êáåÉj~êáåÉj~êáåÉ=
Software Description
Document No. Designation Revision Issue
F-07868-00016-SB log-files download SD-card 1.5 10. 02.2015
Name: ba.marquardt
10/12
Date: 01.04.2014
3.3 Save Parameter Files
5. Start Screen
This image will appear on the touch screen display once
the system has booted. Pressing the Menu button on the
start screen will bring up the Main Menu
6. Main Menu
Pressing the System button will bring up the System
Service Menu.
7. System Service
Pressing the Parameter button will bring up the
Parameter menu.
8. Parameter Menu
Press Save on USB to store a current parameter file to
an USB-device.
eçééÉ=eçééÉ=eçééÉ=eçééÉ=j~êáåÉj~êáåÉj~êáåÉj~êáåÉ=
Software Description
Document No. Designation Revision Issue
F-07868-00016-SB log-files download SD-card 1.5 10. 02.2015
Name: ba.marquardt
11/12
Date: 01.04.2014
Note: Before physically disconnecting the USB-device form the HOMIP be sure to Release USB .
The command Release USB can be found under the System Service menu. (Please see last
section of this document)
3.4 Release USB-Device
If a USB-device has been used to update or store information parameter it has to be “released” by
the software before it can be physically removed. Pressing the Release USB button in the System
Service or the Parameter menu starts the script to finalize writing all information onto the USB-
device and disconnects.
1. Start Screen
This image will appear on the touch screen display once
the system has booted. Pressing the Menu button on the
start screen will bring up the Main Menu with the
following options.
2. Main Menu
Pressing the System button will bring up the System
Service menu with the following options.
eçééÉ=eçééÉ=eçééÉ=eçééÉ=j~êáåÉj~êáåÉj~êáåÉj~êáåÉ=
Software Description
Document No. Designation Revision Issue
F-07868-00016-SB log-files download SD-card 1.5 10. 02.2015
Name: ba.marquardt
12/12
Date: 01.04.2014
3. System Service
Press the Release USB button. The device can be
physically removed.
top related