Transcript
8/3/2019 Enablement Technologies
1/23
Question 1 of 60
Which PowerCenter Client tool is used to install native SAP Netweaver MySAP programs onto
the SAP Netweaver MySAP application server?
Choose Answer
(A) The Repository Manager
(B) The Source Analyzer
(C) The Mapping Designer
(D) The Server Manager
Question 2 of 60
PowerCenter Connect for PeopleSoft can use the PeopleSoft table XLATTABLE as either a
data source or a lookup. As a designer, you may need to join the XLATTABLE with another
table. You may also be able to obtain similar results by using the XLATTABLE as a lookup.
Assuming that both methods are possible, what is the primary difference between using the
XLATTABLE as a source or as a lookup?
Choose Answer
(A) Using it as a source will result in an inner equijoin, and therefore no rowswill be extracted unless a matching row is found in the other source.
(B)Using it as a lookup will enable it to be cached, resulting in greater efficiency in
locating matched values.
(C) Using it as a source will result in a performance increase.
(D) Using it as a lookup will result in a performance increase.
Question 3 of 60
What is the function of the PowerCenter Integration Service when running a session with
PowerCenter Connect for Siebel?
Choose Answer
(A) To import the Siebel business components.
8/3/2019 Enablement Technologies
2/23
(B) To import the Siebel business components and associated Siebel tables.
(C) To extract data and metadata from the Siebel Business Objects Layer.
(D) To extract data from the physical database tables.
Question 4 of 60
In which file are PowerExchange Nodes defined?
Choose Answer
(A) DBMOVER.CFG.
(B) PWXMVR.CFG.
(C) The MS Windows Registry file.
(D) DBMOVER.INI.
Question 5 of 60
When PowerCenter Connect for IBM MQSeries extracts data, which MQSeries component
can supply the data that is extracted?
Choose Answer
(A) The message header.
(B) The message data.
(C) The message header and the message data.
(D) The message data and the message queue.
Question 6 of 60
What tools can be used to create Informatica PowerChannel accounts?
Choose Answer
8/3/2019 Enablement Technologies
3/23
(A) The PowerChannel Repository Manager or the PowerChannel web client.
(B) The PowerChannel Repository Manager or the PowerChannel Server Manager.
(C) The PowerChannel web client or the PowerChannel Administrator.
(D) The PowerChannel web client or the PcCmd command line utility.
Question 7 of 60
The Analytic Business Components contains a set of SAP Netweaver MySAP source
definitions that are used as sources for the mapplets in the repository. What is the
relationship between all tables and views in Netweaver MySAP MySAP and the source
definitions that are in the repository?
Choose Answer
(A) All SAP Netweaver MySAP tables and views are included as a source definition.
(B)All SAP Netweaver MySAP tables and views are included as a source definitionexcept those that may change their definitions over time.
(C)All SAP Netweaver MySAP tables and views are included as a sourcedefinition except index tables that are not relevant to data warehousing.
(D)All SAP Netweaver MySAP tables and views are included as a source definitionexcept master data tables that would supply redundant data to the Mapplet.
Question 8 of 60
Informatica recommends grouping source data before matching to increase the performance
of matching plans in Data Quality Workbench. Which of the following components are used
to generate groups?
Choose Answer
(A) Token Labeler and RuleBased Analyzer
(B) Mixed Field Matcher
(C) Word Manager with a Merge
(D) Soundex or NYSIIS
8/3/2019 Enablement Technologies
4/23
Question 9 of 60
What is the smallest time granularity Data Analyzer supports for data analysis?
Choose Answer
(A) daily
(B) hourly
(C) minutes
(D) seconds
Question 10 of 60
Data Explorer uses table structural profiling to look for which of the following?
Choose Answer
(A) Inferred redundancies
(B) Functional dependencies
(C) Synonyms
(D) Inferred metadata from a set of columns
Question 11 of 60
Which PowerCenter Client tool is used to import SAP functions?
Choose Answer
(A) The Source Analyzer.
(B) The Expression Editor.
(C) The Mapping Designer.
(D) SAP functions cannot be imported with PowerCenter.
8/3/2019 Enablement Technologies
5/23
Question 12 of 60
How does PowerCenter Connect for SAP Netweaver MySAP import Netweaver MySAP logical
tables?
Choose Answer
(A) By using the RFC (Remote Function Call) protocol.
(B) By using Application Server control files.
(C) Through an ODBC connection to the host database.
(D) Through a native connection to the host database.
Question 13 of 60
When setting up PowerCenter to extract data from Netweaver MySAP, the saprfc.ini file
needs to be configured on which machines?
Choose Answer
(A) The PowerCenter Integration Service machine
(B)The PowerCenter Integration Service machine and PowerCenter clientmachines
(C)The PowerCenter Integration Service machine and Netweaver MySAP server
machine
(D)The PowerCenter Integration Service machine, PowerCenter client machines andNetweaver MySAP server machine.
Question 14 of 60
Which statement below best describes when more than one partition can be set in a session
with a SAP Netweaver MySAP data source?
Choose Answer
(A)A session can contain multiple partitions if the mapping does not containhierarchies or IDOCs.
(B)A session cannot contain multiple partitions if it uses exec SQL to generate theABAP program.
8/3/2019 Enablement Technologies
6/23
(C)A session can contain multiple partitions only if it is possible to specify date key
ranges for columns with the data types DATS or ACCP.
(D)PowerCenter does not support partitioning of SAP Netweaver MySAP sources
without using multiple sessions.
Question 15 of 60
When using PowerCenter Connect for SAP Netweaver MySAP to extract data from SAP
Netweaver MySAP, what is the difference between Exec SQL and Open SQL?
Choose Answer
(A)Exec SQL is standard SQL that accesses the physical database directly,
while Open SQL is written in ABAP, the proprietary language of SAP.
(B)Exec SQL is standard SQL that accesses the physical database directly, and Open
SQL is written in BASIS, the proprietary language of SAP.
(C)Exec SQL is written in ABAP, the proprietary language of SAP, and Open SQL is
standard SQL that accesses the physical database directly.
(D)Exec SQL is written in BASIS, the proprietary language of SAP, and Open SQL is
standard SQL that accesses the physical database directly.
Question 16 of 60
Which of the selections below accurately describes using Stream mode to extract data from
Netweaver MySAP using PowerCenter Connect for Netweaver MySAP?
Choose Answer
(A)
The PowerCenter Integration Service reads the data directly from the Netweaver
MySAP tables and processes it through the transformations in the same manner asa session that is processing any other relational database sources.
(B)The PowerCenter Integration Service extracts the Netweaver MySAP data into flatfiles and then access the files through FTP or NFS mount.
(C) The PowerCenter Integration Service extracts the Netweaver MySAP data tobuffers. It then accesses the buffers using a communication protocol.
(D)The PowerCenter Integration Service extracts the Netweaver MySAP datausing CPI-C without staging it or buffering it.
Question 17 of 60
8/3/2019 Enablement Technologies
7/23
What types of SAP Netweaver MySAP metadata objects can be imported with the
PowerCenter Designer?
Choose Answer
(A) Tables, views, and hierarchies
(B) Tables, panels and hierarchies
(C) Tables, hierarchies and files
(D) Tables, hierarchies and IDOCS.
Question 18 of 60
Which statement below does not correctly describe the tables or views that PowerCenter
Connect for PeopleSoft uses?
Choose Answer
(A)A PeopleSoft SQL table always has a one-to-one relationship with an underlying
physical database table.
(B)A PeopleSoft SQL view may offer a view of information in one database
table.
(C) SQL tables and SQL views are types of PeopleSoft records.
(D) Key columns in PeopleSoft SQL views may not contain duplicate values.
Question 19 of 60
Which PowerCenter object would be used to create a user-defined filter on a PeopleSoft
record?
Choose Answer
(A) The relational source definition
(B) The PeopleSoft source definition
(C) The PeopleSoft Source Qualifier transformation
(D) The Application Source Qualifier transformation
8/3/2019 Enablement Technologies
8/23
Question 20 of 60
PowerCenter Connect for PeopleSoft can import metadata from what types of PeopleSoft
trees?
Choose Answer
(A) Detail and Panels
(B) Detail and Summary
(C) Detail, Summary, and Atomic
(D) Detail, Summary, and Winter
Question 21 of 60
From what types of PeopleSoft objects does PowerCenter Connect for PeopleSoft extract
source data?
Choose Answer
(A) Tables and views
(B) Tables and trees
(C) Records and trees
(D) Records and views
Question 22 of 60
Which answer below describes all the ways in which PowerCenter Connect for PeopleSoft
can filter PeopleSoft records and trees?
Choose Answer
(A) Record name or tree name.
(B) Record name, business name, or tree name.
(C) Record name or Panel name.
8/3/2019 Enablement Technologies
9/23
(D) Record name, Panel name, or tree name.
Question 23 of 60
In order to make use of PowerCenter Connect for PeopleSoft, database connectivity is
required to which classes of tables?
Choose Answer
(A) To the PeopleSoft metadata tables.
(B) To the PeopleSoft physical database tables.
(C) To both the PeopleSoft metadata tables and the physical database tables.
(D)To either the PeopleSoft metadata tables or the physical database tables,
depending on the session requirements.
Question 24 of 60
Which statement below is not correct in describing the joining of two PeopleSoft records in
PowerCenter Connect for PeopleSoft?
Choose Answer
(A)The records must have a primary key-foreign key relationship in the PeopleSoft
database tables.
(B)The records can have a primary key-foreign key relationship in the PowerCenter
source definitions.
(C)PowerCenter primary key-foreign key relationships for PeopleSoft source
definitions can be created in the Source Analyzer.
(D) The join columns in the physical database tables must be indexed.
Question 25 of 60
When using PowerCenter Connect for Siebel, which method can be used when sorted data is
required?
Choose Answer
8/3/2019 Enablement Technologies
10/23
(A)
Add an ORDER BY clause to the Application Source Qualifier
transformation SQL either by overriding the SQL statement or using theNumber of Sorted Ports property.
(B)Sort the data within the appropriate Siebel Business Component prior to importingit with PowerCenter Connect for Siebel.
(C) Sort the data with a Rank transformation after importing it with PowerCenterConnect for Siebel.
(D)
Importing sorted data with PowerCenter Connect for Siebel is not supported unlessthe data is already sorted in the Siebel database table, in which case no action is
necessary.
Question 26 of 60
Which statement below correctly describes the use of PowerCenter Connect for Siebel for
applying filtering criteria to restrict the number of Siebel objects that appear in the ImportSiebel Metadata dialog box?
Choose Answer
(A)Filter criteria can be applied to both Siebel table columns and Business
Components.
(B) Filter criteria can be applied Siebel table columns only.
(C) Filter criteria can be applied to Business Components and tables only.
(D)Filter criteria cannot be applied to Siebel objects in the Import Siebel Metadata
dialog box.
Question 27 of 60
PowerCenter Connect for Siebel generates a default query to pull data from Siebel tables.
Which statement below correctly describes the relationship between the SELECT statement
and the Application Source Qualifier transformation?
Choose Answer
(A)The number of columns in the SELECT statement must be equal to the number of
columns in the Application Source Qualifier transformation default query.
(B)The order of the columns in the SELECT statement must match the order of the
selected ports in the Application Source Qualifier transformation.
(C) You may modify table names in the extract override SQL.
8/3/2019 Enablement Technologies
11/23
(D)
If the column data types in the SELECT statement are different from the
data types of the corresponding Application Source Qualifiertransformation ports, the data types must be compatible.
Question 28 of 60
Which types of Siebel objects can be imported as PowerCenter source definitions using
PowerCenter Connect for Siebel?
Choose Answer
(A) Business components and tables.
(B) Business components, business objects and tables.
(C) Business components and business objects.
(D) Business components, tables and join specifications.
Question 29 of 60
What is a recommended method for using PowerCenter Connect for Siebel without
compromising existing Siebel security?
Choose Answer
(A)Do not release Siebel metadata database username or passwords to PowerCenterConnect for Siebel designers.
(B)Do not release Siebel metadata database or application database username orpasswords to PowerCenter Connect for Siebel designers.
(C)Create new database usernames for the Siebel metadata and applicationdata with read-only privilege.
(D)Export Siebel application data and metadata to flat files prior to importing them
with PowerCenter Connect for Siebel.
Question 30 of 60
In any attempt to join two or more Siebel sources using a single Application Source Qualifier
transformation, which statement below best describes the requirements?
8/3/2019 Enablement Technologies
12/23
Choose Answer
(A)User-defined joins are supported only when there is a corresponding JoinSpecification on the Siebel Business Objects Layer.
(B)
If the sources share one or more columns that have a primary key-foreign
key relationship in the PowerCenter repository, the Application SourceQualifier transformation will automatically join them.
(C) Inner joins only are supported.
(D)You may modify the join syntax manually by overriding the Application Source
Qualifier transformation SQL.
Question 31 of 60
When installing PowerCenter Connect for Siebel in an environment where PowerCenter andSiebel systems are already installed, on which machines does additional software need to be
installed?
Choose Answer
(A) The PowerCenter Integration Service machine.
(B)
The PowerCenter Integration Service machine and any PowerCenterClient machines that will be used to create PowerCenter Connect for
Siebel components.
(C)
The PowerCenter Integration Service machine, any PowerCenter Client machines
that will be used to create PowerCenter Connect for Siebel components, and theSiebel applications server machine.
(D)
The PowerCenter Integration Service machine, any PowerCenter Client machines
that will be used to create PowerCenter Connect for Siebel components, the Siebelapplications server machine(s), and the Siebel database server machine (if
different from the applications server).
Question 32 of 60
When sourcing data in a mainframe environment, what are the requirements for Informatica
PowerExchange to read from fixed sequential block data files in a single pass?
Choose Answer
(A) This function is always supported.
8/3/2019 Enablement Technologies
13/23
(B) There must be no REDEFINES clauses in the COBOL copybook.
(C) There must be no more than one REDEFINES clause in the COBOL copybook.
(D) This function is not supported. Reading from this type of file is always multi-pass.
Question 33 of 60
What is the main method used by Informatica PowerExchange for DB2 to increase
performance and efficiency?
Choose Answer
(A) Moving compressed data.
(B) The data that is moved is not compressed, releasing processor resources.
(C) Time is not taken to stage flat files.
(D) All available channel resources are automatically utilized.
Question 34 of 60
Must a PowerExchange Listener always be running for an Informatica PowerExchangeenvironment to function?
Choose Answer
(A)Yes. A Listener must always be running regardless of where the data source andPowerCenter Integration Service are running.
(B)No. A Listener is not needed when the data being accessed is on a separatemachine from the PowerCenter Integration Service.
(C)No. A Listener is not needed if the data being accessed is on the same machine asthe PowerCenter Integration Service.
(D)Yes. A Listener is needed when the data being accessed is on a separatemachine from the PowerCenter Integration Service
Question 35 of 60
8/3/2019 Enablement Technologies
14/23
In order to access Oracle data in real time, must a Listener run on each Oracle instance
being accessed?
Choose Answer
(A) No, because a DBMover.cfg file can define multiple nodes and Oraclesclient software supports the LogMiner API.
(B)Yes, because a DBMover.cfg file can only be used to define one Oracle node at a
time.
(C)Yes, because a DBMover.cfg file can define multiple nodes but Oracles client
software does not support the LogMiner API.
(D)No, because a DBMover.cfg file can only be used to define one Oracle node at a
time and Oracles client software does not support the LogMiner API.
Question 36 of 60
For which of the data sources below does Informatica PowerExchange provide only indirect
access?
Choose Answer
(A) Physical sequential fixed block files produced by COBOL extract programs.
(B) ADABAS nested tables.
(C) ISAM files.
(D) Fixed sequential files.
Question 37 of 60
Which statement below does not contain a list of mainframe data sources accessible via
Informatica PowerExchange?
Choose Answer
(A) DB2, ADABAS, IMS, and Unidata
(B) DB2, ADABASE, Datacom, and IMS
(C) DB2, ADABASE, IDMS, and Datacom
8/3/2019 Enablement Technologies
15/23
(D) DB2, Datacom, IMS, and IDMS
Question 38 of 60
Which statement below correctly describes valid CAPXRT and CAPX advanced parameters?
Choose Answer
(A) SL, RS, BA, AI, and FI
(B) SL, RS, BA, AI, and TU
(C) SL, RS, BA, FI, and TU
(D) SL, RS, FI, and TU
Question 39 of 60
Which data type below is not supported by Informatica PowerExchange?
Choose Answer
(A) UDB
(B) Oracle
(C) Sybase
(D) SQL Server
(E) Informix
Question 40 of 60
What is the main advantage of using Informatica PowerExchange to source from mainframe
systems?
Choose Answer
8/3/2019 Enablement Technologies
16/23
(A) The use of gateway machines and software can always be avoided.
(B) The use of COBOL batch programs can always be avoided.
(C) All mainframe data sources can be read by a single integration platform.
(D) Flexible data access from a platform that does not require custom code.
Question 41 of 60
Which statement below is correct in describing Informatica PowerExchange for DB2?
Choose Answer
(A) Even after PowerExchange for DB2 is installed and correctly configured, IBM DB2Connect is still required to access and move data.
(B) The product requires IBM DB2 for S/390 to be used as a PowerCenter data source.
(C) The product requires IBM DB2 for S/390 to be used as a PowerCenter data target.
(D)The product allows PowerCenter to receive captured changes from DB2
tables.
Question 42 of 60
In which modes can Informatica PowerExchange access changes to source data?
Choose Answer
(A) Download just changed data periodically
(B) Trickle changed data through PowerCenter in Real Time
(C) Both A & B
(D) None of the above
Question 43 of 60
What are some of the primary advantages of using Informatica PowerExchange to issue IBM
DB2 Static SQL to access mainframe DB2 data?
8/3/2019 Enablement Technologies
17/23
Choose Answer
(A)Increased performance over standard SQL and ability to conduct data conversionswhile transferring data, such as EBCDIC to ASCII and packed decimal to character.
(B)Allows the use of DB2 datamaps to define sub-fields in DB2 columns as
necessary.
(C)
Ability to use DB2 plan-based security options and ability to conduct data
conversions while transferring data, such as EBCDIC to ASCII and packed decimalto character.
(D)Ability to use DB2 plan-based security options and ability to automatically accessDB2 catalogs.
Question 44 of 60
PowerCenter supports the use of IBM DB2 Connect for native data access to DB2 database
systems on IBM AS/400 and mainframe operating systems. What is a primary disadvantage
of using DB2 Connect as compared to Informatica PowerExchange?
Choose Answer
(A)Bandwidth. Too many simultaneous channels are needed to access the large
number of multiple DB2 tables needed by business intelligence applications.
(B)IBM DB2 Connect does not support real time transfer of changed datafrom any DB2 system.
(C)
Data type conversions. Although DB2 Connect does support conversions, it doesnot support the wide range of necessary conversions required for business
intelligence applications.
(D)
Flexibility and adaptability. Because DB2 Connect was originally designed for use
with IBM Universal Database on Unix, it does not exhibit the flexibility required fortoday's diverse business intelligence requirements.
Question 45 of 60
Which statement below correctly describes the function of an Informatica PowerExchange
Data Map?
Choose Answer
(A)A Data Map maps the data from the way it is organized in a target to a relationalview in the source so PowerCenter can consume the data.
8/3/2019 Enablement Technologies
18/23
(B) A Data Map is the same thing as a PowerCenter data source object.
(C) There is no such thing as a Data Map in Informatica PowerExchange.
(D)A Data Map creates a relational view of heterogeneous source data for
consumption by PowerCenter.
Question 46 of 60
What additional software is required to move mainframe DB2 data in real time beyond
PowerCenter with Real Time Option, PowerExchange Client for PowerCenter, and
Informatica PowerExchange for Mainframe DB2?
Choose Answer
(A) BMC DataMove is required.
(B) IBM MQ Series is required.
(C) Informatica Metadata Manager is required.
(D) Nothing. These three products are sufficient.
Question 47 of 60
When can PowerCenter Connect for IBM MQSeries run a session that is set to limit the
message data size that is extracted from MQSeries?
Choose Answer
(A) When only a single queue manager is being used as an IBM MQSeries source.
(B) When an associated source qualifier is not used in the mapping.
(C) When a channel table file is not used to connect to the message queue.
(D) When the message data is in binary format.
Question 48 of 60
8/3/2019 Enablement Technologies
19/23
Which of the following selections is not a type of message data that can be read by a
PowerCenter Connect for IBM MQSeries associated source qualifier transformation?
Choose Answer
(A) Relational message data.
(B) Flat file message data.
(C) XML message data.
(D) COBOL / VSAM message data.
Question 49 of 60
While using PowerCenter Connect for IBM MQSeries, what is the primary difference between
using the MQSERVER system environment variable or a channel table file to connect to
message queues?
Choose Answer
(A) Using the channel table file will usually improve session performance.
(B)Using the MQSERVER environment variable will usually improve session
performance.
(C) The MQSERVER environment variable can be used to connect the PowerCenterIntegration Service to multiple queue managers.
(D)The channel table file can be used to connect the PowerCenter Integration
Service to multiple queue managers.
Question 50 of 60
What type of IBM MQSeries target is supported by PowerCenter Connect for IBM MQSeries?
Choose Answer
(A) Any type of IBM MQSeries component that stores data.
(B) Any single IBM MQSeries message queue.
(C) Any single or multiple IBM message queues.
8/3/2019 Enablement Technologies
20/23
(D)None. PowerCenter Connect for IBM MQSeries can read from IBM MQSeries
components but writing to them is not supported.
Question 51 of 60
Which components can be used by PowerCenter Connect for MQSeries to filter messages for
extraction?
Choose Answer
(A) The message header data.
(B) The message data.
(C) The message header data or the message data.
(D)No IBM MQSeries components can be used to filter messages, but a Filter
transformation can be used in the mapping to remove undesired rows.
Question 52 of 60
What type of data can be transferred using Informatica PowerChannel?
Choose Answer
(A) Flat file data.
(B) Relational data.
(C)Flat file data and relational data, after the relational data has been
converted to a flat file.
(D)Flat file data, IBM MQSeries message queues, and relational data, after the
relational data has been converted to a flat file.
Question 53 of 60
What is the recommended action if the Informatica PowerChannel repository key is
compromised (becomes available to an unauthorized person)?
Choose Answer
8/3/2019 Enablement Technologies
21/23
(A) Re-encrypt the repository.
(B) Delete and restore the repository from a backup, using a new uncompromised key.
(C)Copy the repository using a new uncompromised key, delete the repository, and
use the copy as the new repository.
(D)No action is necessary unless the repository key is static (which is notrecommended for production repositories).
Question 54 of 60
What is the purpose of an Informatica PowerChannel certificate account?
Choose Answer
(A)It is used by a PowerChannel server to authenticate itself when
communicating with a remote PowerChannel server.
(B) It is used by a PowerChannel user to access, encrypt and decrypt the repository.
(C) It is used to authenticate individual users.
(D) It is used to schedule, start and stop individual PowerChannel sessions.
Question 55 of 60
What is the primary benefit of using an XML command file rather than PcCmd to run
Informatica PowerChannel commands?
Choose Answer
(A) Multiple PowerChannels can be used simultaneously.
(B)Multiple commands can be run, allowing the creation of a custom
command structure.
(C)All PowerChannel commands are supported, where PcCmd only supports a subset
of all commands.
(D)It is the only means of initializing the PowerChannel Server after the repositoryhas been routinely re-encrypted.
Question 56 of 60
8/3/2019 Enablement Technologies
22/23
What types of accounts are needed to perform all functions with Informatica PowerChannel?
Choose Answer
(A) User and certificate.
(B) User, certificate, and at least one channel.
(C) User, certificate, repository, and at least one channel.
(D) User, certificate, and admin.
Question 58 of 60
Complete the following sentence: An Analytic Business Component that contains one ormore source definitions is called a
Choose Answer
(A) Compound Business Component.
(B) Source Business Component.
(C) ERP Business Component.
(D) Complex Business Component.
Question 59 of 60
What is an SAP NetWeaver mySAP Analytic Business Component that contains one source
definition and no transformation objects except the Application Source Qualifier
transformation called?
Choose Answer
(A) Simple Business Component.
(B) Complex Business Component.
(C) Single Source Business Component.
(D) ERP Business component.
8/3/2019 Enablement Technologies
23/23
Question 60 of 60
How does Informatica supply SAP NetWeaver mySAP Analytic Business Components to the
user?
Choose Answer
(A) As a set of folders holding mapplets, mappings and associated objects.
(B) As a single folder holding mapplets, mappings and associated objects.
(C) As a set of XML import-files holding the ABC object definitions.
(D) As a single XML import-file holding the ABC object definitions.
top related