CFD Modeling of Utility Boiler Components at ALSTOM Power ...acerc.byu.edu/News/Conference/2004/Presentations/Galen...SCR - Ammonia Injection Grid Normalized mole fraction ratio: NH

Post on 20-Jul-2021

5 Views

Category:

Documents

1 Downloads

Preview:

Click to see full reader

Transcript

Feb. 13, 2004Feb. 13, 2004

CFD Modeling of Utility Boiler Components at

ALSTOM Power Inc.Galen Richards

2-2-2004 Power Plant Laboratories

CFD at ALSTOM Power Inc.

Power Plant Laboratories (Windsor, CT)– 6 Engineers - full time CFD– 4 Engineers - part time CFD– Mainly use FLUENT– Also use CFX, Aiolos– Product development / problem solving for the Utility

Boiler business– Chemical process industry

2-2-2004 Power Plant Laboratories

PPL CFD Examples - Burners

Wall-Fired Coal Burner

LNCFS - P2™ Coal Nozzle

2-2-2004 Power Plant Laboratories

PPL CFD Examples - Boilers

HRSGStokerPC Boiler

2-2-2004 Power Plant Laboratories

PPL CFD Examples -Gas Turbine Combustors

2-2-2004 Power Plant Laboratories

Steam Drum Internals

2-2-2004 Power Plant Laboratories

PPL CFD Examples -Steam Drum Internals

Velocity Water m/s

4 Vanes 12 Vanes

2-2-2004 Power Plant Laboratories

Pulverizers

2-2-2004 Power Plant Laboratories

Pulverizer - Classifier Design

Static Classifiers Dynamic Classifiers

2-2-2004 Power Plant Laboratories

Pulverizer - Exhauster Design

Geometry Particle Concentration

2-2-2004 Power Plant Laboratories

Pulverizer - Exhauster Design

Predicted Errosion Patterns

2-2-2004 Power Plant Laboratories

Oil-Fired Utility Boiler

2-2-2004 Power Plant Laboratories

Oil Burner - Impact of Tilt

Windbox

Aux Air Nozzles20o Up Tilt

Fuel Air Nozzle 20o Up Tilt

2-2-2004 Power Plant Laboratories

Oil-Fired Boiler

Particle Trajectories Gas Temperature

2-2-2004 Power Plant Laboratories

Natural Gas-Fired Utility Boiler

2-2-2004 Power Plant Laboratories

Gas-Fired Boiler: Description

MCR 700 MWNatural gas fuelTangential firing system5 burner elevations30% flue gas recirculation (FGR)FGR with combustion air 12% separated overfire air (SOFA)50 ppm NOx

2-2-2004 Power Plant Laboratories

Gas Fired Boiler

Objective: Low cost solution for NOx of 15 ppm

NOx reduction strategies– Increased FGR– Steam or water injection– SOFA quantity and location– Burners out of service– Decreased load

2-2-2004 Power Plant Laboratories

Gas-Fired Boiler: Geometry

Windbox

SOFA

DivisionPanels

Economizer

Reheater

SH PendantSH Platen

Outlet

2-2-2004 Power Plant Laboratories

Gas-Fired Boiler: Geometry

Gas Inlet

Oil Air Inlet

Gas InletCombustionAir Inlet

Gas Inlet

Oil Air Inlet

Gas Inlet

2-2-2004 Power Plant Laboratories

Gas-Fired Boiler: Baseline

Temperature Oxygen NOx

2-2-2004 Power Plant Laboratories

Gas-Fired Boiler: NOx vs FGR

0

10

20

30

40

50

60

25 30 35 40 45 50% FGR

NO

x [p

pm-d

ry, c

or.]

NOx-Predicted

NOx-Measured

2-2-2004 Power Plant Laboratories

Gas-Fired Boiler: Conclusions

NOx emissions of 15 ppmachievable – Increase FGR to 45%– Inject 60,000 lb/hr of steam or

water through oil guns– or reduction to 950 ºF SH – Add independent yaw control

on SOFA tips to tune for CO

100 micron water droplets

2-2-2004 Power Plant Laboratories

SCR Design Issues– Flow Distribution– Temperature Distribution– System Pressure Drop– Particle Collection

2-2-2004 Power Plant Laboratories

SCR Design

TurningVanes

Mixer

AIG EconomizerOutlet

Catalyst

2-2-2004 Power Plant Laboratories

SCR - Velocity Distribution

Velocity ft/s

2-2-2004 Power Plant Laboratories

SCR - Measured NOx Profile

NOx, ppm

A - Side

B - Side

2-2-2004 Power Plant Laboratories

SCR - Ammonia Injection Grid

2-2-2004 Power Plant Laboratories

SCR - Ammonia Injection GridNormalizedmole fractionratio: NH3/NO

2-2-2004 Power Plant Laboratories

SCR - Vane Design

Suggested Vane Installation

Max velocityat corner ~ 130 fps

Velocity at cornerreduced to ~ 80 fps

No Vanes in SCR Outlet

2-2-2004 Power Plant Laboratories

SCR - Particle Collection

50 microns 250 microns

2-2-2004 Power Plant Laboratories

SCR - Particle Collection

0%

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

0 50 100 150 200 250 300 350 400 450 500

Low Load - Flyash

High Load- Flyash

Col

lect

ed in

Hop

pers

(%)

Flyash Diameter - microns

2-2-2004 Power Plant Laboratories

SCR - Duct Metal Temperature

Diverging Section(includes spreader vanes)

Skin

Tem

pera

ture

(oR

)

SCR Inlet Duct

AIG Lances

Economizer Bypasses

2-2-2004 Power Plant Laboratories

Conclusions

CFD is a valuable design tool for a wide range of power generation applications

www.alstom.com

Information disclosed herein is furnished to the recipient solely for the use thereof as has been agreed upon with ALSTOM and all rights to such information are reserved by ALSTOM.

The recipient of the information disclosed herein agrees, as a condition of its receipt of such information, that ALSTOM shall have no liability for any direct or indirect damages including special, punitive, incidental, or consequential damages caused by, or arising from, the recipient’s use or non-use of the information.