A Simulation Tool for Thermal Engineering

27th July 2011

COMPANY CONFIDENTIAL

Culture creates future

Why thermal model is needed?

Smaller chip reduces parasitic effect.

Less parasitic allows for high frequency with less switching loss.

Efficient high frequency allows further size reduction.

In order to make a smaller and higher power switch, the thermal limit must be pushed back.

COMPANY CONFIDENTIAL

Culture creates future

What is thermal impedance

powerTT

Z ambjth

Silicon chip

Solder/Wire

Copper frame

Epoxy

COMPANY CONFIDENTIAL

Culture creates future

Foster-equivalent model have a real physical meaning: each RC cell represents the contribution to the thermal impedance of a given part

What is Thermal impedance Foster circuit

4

1

exp1n nn

nth RCtRtZ

COMPANY CONFIDENTIAL

Culture creates future

Deliverable of the Our Tool

a universal and simple method of representing the thermal character of a device

Interpret values from datasheet or measurement

The tool would allow a power plot using a SPICE simulator to accurate represent package temperatures.

Employed as vehicle to cross compare techniques.

COMPANY CONFIDENTIAL

Culture creates future

Tool Demonstration

COMPANY CONFIDENTIAL

Culture creates future

ResultsTemperature response to oscilloscope waveform

0

10

20

30

40

50

60

70

80

0

10

20

30

40

50

60

70

80

0 10 20 30 40 50

Input power [W

]Ju

nctio

n Te

mpe

ratu

re [

C]

Time [us]

Junction temperature

Input Power

Temperature Limit

COMPANY CONFIDENTIAL

Culture creates future

0%

20%

40%

60%

80%

100%

0

50

100

150

200

250

300

1 10 100 1000 10000

Failu

re R

ate

Qua

ntity

in T

est

Test Time (Hours)

5 yr

Temperature Operating Life test underwent using JESD22-A108 standard

Applicationbeneficial of the tool

Controlled lifetime

Reliable performance

Reduced manufacture cost

Reduced maintenance costs

Jc/TeLife

IFR (Intrinsic Failure Rate)low, constant

Useful life period

Wearoutperiod

EFR

Time

Failu

re ra

te

0

COMPANY CONFIDENTIAL

Culture creates future

Advantage Related Art benchmark

Supplier BCauer RC networks included in

the datasheet

Supplier DUse two additional pins

for junction temperature from RC networks

Supplier COnline calculator and some

thermal RC networks

Supplier ECauer RC networks included in a apps

note for each part

Supplier AFoster networks RC networks

included in the datasheet

Thank you