Audiomatica ClioWin 7 – Measurement System

Topics

General System Overview System Philosophy System Hardware and Accessories Software Layout Measurement Modules Some Application Examples

Clio Measurement System

Clio uses a simple audio platform for computer In/Out – PCI Card

Calculations are based Computer CPU A signal conditioner is used as a Front-

End with the external world Additional accessories may expand

functions and possibilities

Clio Measurement System

PB-4281 PCI board and SC-01 Signal Conditioner

Clio Measurement System

Clio Accessories

CLIOQC Model 4 Amplifier & SwitchBox

The QCBOX

Clio Measurement System:General Application

Clio Measurement System: Clio + QCBOX Amplifier

Clio Measurement System: QCBOX used as a connection panel

Clio Accessories: The Microphones Mic-01 & Mic-02

Clio Accessories

0 or 20 dBof Gain

A,B,C Weighting Filters Selectable

ClioWin version 7: Calibration Procedure

Clio Measuremen

t System:

Measurement

Precision

Clio Measuremen

t System:

Measurement

Precision

ClioWin version 7 – Software Layout

ClioWin version 7 – Software Layout

ClioWin version 7 – Software Layout

ClioWin version 7 – Software Layout:User selectable options

ClioWin version 7 – Software Layout:External Hardware Interface

ClioWin version 7 – Software Layout:Generator dialog boxes

ClioWin version 7 – Generator

ClioWin version 7 – Software Layout:Measurement Notes

ClioWin version 7 – Software Layout:Graphics & Data Export

ClioWin 7: Multiple Document Layout

ClioWin 7: Multiple Document Layout

ClioWin 7: MLS & Log Chirp Module

ClioWin 7: MLS & Log Chirp Module

ClioWin 7: MLS & Log Chirp Module

ClioWin 7: Cumul. Spectral Decay

ClioWin 7: Cumul. Spectral Decay

ClioWin 7: Polar Directivity Map

ClioWin 7: Polar Analysis

ClioWin 7: Acoustical Parameters

ClioWin 7: Acoustical Parameters

ClioWin 7: FFT Spectrum + Time Data

ClioWin 7: RTA Spectrum Analyzer

ClioWin 7: "LIVE" Transfer Function

Sinusoidal Freq. Response + Harmonics

ClioWin 7: Sinusoidal Impedance

ClioWin 7: Multi-Meter Module

ClioWin 7: T&S Parameters Modules

ClioWin 7: Wow & Flutter Analysis

ClioWin 7: Leq Sound Level Analysis

ClioWin 7: Linearity Analysis

ClioWin 7: Distortion Analisys

ClioWin 7: QC Capability

ClioWin 7: A QC Script

QC: Tolerance masks (Limits)

relative limits

absolute limits

[RELATIVE][UPPER LIMIT DATA]200 5300 210000 215000 5[LOWER LIMIT DATA]200 -5300 -210000 -215000 -5

[ABSOLUTE][UPPER LIMIT DATA]200 100300 9710000 9715000 100[LOWER LIMIT DATA]200 82300 8510000 8515000 82

QC: Sensitivity & Level check

QC: Sensitivity & Level check

level shift

QC: Sensitivity & Level check[RELATIVE][LEVEL]UPPER=3LOWER=-3FREQHI=5000FREQLO=400[UPPER LIMIT DATA]200 5300 210000 215000 5[LOWER LIMIT DATA]200 -5300 -210000 -215000 -5

QC: Sensitivity & Level check[RELATIVE][SENSITIVITY]FREQ1=500FREQ2=1000FREQ3=2000UPPER=102LOWER=100[UPPER LIMIT DATA]200 10500 101000 51500 52000 104000 10[LOWER LIMIT DATA]200 -10500 -101000 -51500 -52000 -104000 -10

QC: T&S parameters check

LIMITS

[TSPARAMETERS]REDC=6.2DIAMETER=110KNOWNMMD=10.7952QTSUPPER=0.6QTSLOWER=0.3FSUPPER=90FSLOWER=50CMSUPPER=1.1CMSLOWER=0.8BLUPPER=6.5BLLOWER=6ZMINUPPER=7.5ZMINLOWER=7

SCRIPT

[SIN]OUT=-2.0IN=0.0REFERENCE=IMPEDANCE.SINILIMITS=IMPEDANCE.LIM

QC: RUB&BUZZ check

LIMITS

[UPPER LIMIT DATA]689.75 82.84793.78 67.80856.99 64.411362.95 65.681693.42 59.961737.23 58.261982.28 62.922223.72 51.692625.30 56.992883.04 48.313462.13 45.553659.12 38.564018.35 40.254283.29 35.384887.50 30.725696.91 35.177292.28 26.0621046.80 22.88

SCRIPT

[FFT]OUT=0.0IN=-10REFERENCE=R&B.FFTLIMITS=R&B.LIM

QC: THD & Harmonics checkLIMITS

[UPPER LIMIT DATA]1000 1062000 1165000 1167000 96[LOWER LIMIT DATA]1000 892000 994000 996000 80[3 UPPER LIMIT DATA]300 70500 902000 905000 70[4 UPPER LIMIT DATA]200 55400 681300 792500 775300 776300 67[THD UPPER LIMIT DATA]200 801000 955300 956300 78

QC: Operator interaction

ClioWin 7: SuggestedHardware & Software Requirements

PentiumII Processor or better1 Free PCI Slot

Microsoft Windows 98, ME, 2000 or XP 1024x768 256 Colors Video or better