Audiomatica ClioWin 7 – Measurement System
Audiomatica ClioWin 7 – Measurement System
Topics
General System Overview System Philosophy System Hardware and Accessories Software Layout Measurement Modules Some Application Examples
Clio Measurement System
Clio uses a simple audio platform for computer In/Out – PCI Card
Calculations are based Computer CPU A signal conditioner is used as a Front-
End with the external world Additional accessories may expand
functions and possibilities
Clio Measurement System
PB-4281 PCI board and SC-01 Signal Conditioner
Clio Measurement System
Clio Accessories
CLIOQC Model 4 Amplifier & SwitchBox
The QCBOX
Clio Measurement System:General Application
Clio Measurement System: Clio + QCBOX Amplifier
Clio Measurement System: QCBOX used as a connection panel
Clio Accessories: The Microphones Mic-01 & Mic-02
Clio Accessories
0 or 20 dBof Gain
A,B,C Weighting Filters Selectable
ClioWin version 7: Calibration Procedure
Clio Measuremen
t System:
Measurement
Precision
Clio Measuremen
t System:
Measurement
Precision
ClioWin version 7 – Software Layout
ClioWin version 7 – Software Layout
ClioWin version 7 – Software Layout
ClioWin version 7 – Software Layout:User selectable options
ClioWin version 7 – Software Layout:External Hardware Interface
ClioWin version 7 – Software Layout:Generator dialog boxes
ClioWin version 7 – Generator
ClioWin version 7 – Software Layout:Measurement Notes
ClioWin version 7 – Software Layout:Graphics & Data Export
ClioWin 7: Multiple Document Layout
ClioWin 7: Multiple Document Layout
ClioWin 7: MLS & Log Chirp Module
ClioWin 7: MLS & Log Chirp Module
ClioWin 7: MLS & Log Chirp Module
ClioWin 7: Cumul. Spectral Decay
ClioWin 7: Cumul. Spectral Decay
ClioWin 7: Polar Directivity Map
ClioWin 7: Polar Analysis
ClioWin 7: Acoustical Parameters
ClioWin 7: Acoustical Parameters
ClioWin 7: FFT Spectrum + Time Data
ClioWin 7: RTA Spectrum Analyzer
ClioWin 7: "LIVE" Transfer Function
Sinusoidal Freq. Response + Harmonics
ClioWin 7: Sinusoidal Impedance
ClioWin 7: Multi-Meter Module
ClioWin 7: T&S Parameters Modules
ClioWin 7: Wow & Flutter Analysis
ClioWin 7: Leq Sound Level Analysis
ClioWin 7: Linearity Analysis
ClioWin 7: Distortion Analisys
ClioWin 7: QC Capability
ClioWin 7: A QC Script
QC: Tolerance masks (Limits)
relative limits
absolute limits
[RELATIVE][UPPER LIMIT DATA]200 5300 210000 215000 5[LOWER LIMIT DATA]200 -5300 -210000 -215000 -5
[ABSOLUTE][UPPER LIMIT DATA]200 100300 9710000 9715000 100[LOWER LIMIT DATA]200 82300 8510000 8515000 82
QC: Sensitivity & Level check
QC: Sensitivity & Level check
level shift
QC: Sensitivity & Level check[RELATIVE][LEVEL]UPPER=3LOWER=-3FREQHI=5000FREQLO=400[UPPER LIMIT DATA]200 5300 210000 215000 5[LOWER LIMIT DATA]200 -5300 -210000 -215000 -5
QC: Sensitivity & Level check[RELATIVE][SENSITIVITY]FREQ1=500FREQ2=1000FREQ3=2000UPPER=102LOWER=100[UPPER LIMIT DATA]200 10500 101000 51500 52000 104000 10[LOWER LIMIT DATA]200 -10500 -101000 -51500 -52000 -104000 -10
QC: T&S parameters check
LIMITS
[TSPARAMETERS]REDC=6.2DIAMETER=110KNOWNMMD=10.7952QTSUPPER=0.6QTSLOWER=0.3FSUPPER=90FSLOWER=50CMSUPPER=1.1CMSLOWER=0.8BLUPPER=6.5BLLOWER=6ZMINUPPER=7.5ZMINLOWER=7
SCRIPT
[SIN]OUT=-2.0IN=0.0REFERENCE=IMPEDANCE.SINILIMITS=IMPEDANCE.LIM
QC: RUB&BUZZ check
LIMITS
[UPPER LIMIT DATA]689.75 82.84793.78 67.80856.99 64.411362.95 65.681693.42 59.961737.23 58.261982.28 62.922223.72 51.692625.30 56.992883.04 48.313462.13 45.553659.12 38.564018.35 40.254283.29 35.384887.50 30.725696.91 35.177292.28 26.0621046.80 22.88
SCRIPT
[FFT]OUT=0.0IN=-10REFERENCE=R&B.FFTLIMITS=R&B.LIM
QC: THD & Harmonics checkLIMITS
[UPPER LIMIT DATA]1000 1062000 1165000 1167000 96[LOWER LIMIT DATA]1000 892000 994000 996000 80[3 UPPER LIMIT DATA]300 70500 902000 905000 70[4 UPPER LIMIT DATA]200 55400 681300 792500 775300 776300 67[THD UPPER LIMIT DATA]200 801000 955300 956300 78
QC: Operator interaction
ClioWin 7: SuggestedHardware & Software Requirements
PentiumII Processor or better1 Free PCI Slot
Microsoft Windows 98, ME, 2000 or XP 1024x768 256 Colors Video or better
Thank you!