Top Banner
roperty of Worthington Distribution. y Not Be Reproduced Without Permission 800-282-8864 Welcome ELAN g! Integration Locks Sales/Support: 800-282-8864 [email protected] Web / Catalog: www.worthingtondistribution.com Training: www.worthingtonu.com Revision 10/24/2012
42

ZWave Lock Programming

Apr 16, 2017

Download

Technology

g4elan
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

WelcomeELAN g! Integration Locks

Sales/Support: [email protected]

Web / Catalog: www.worthingtondistribution.comTraining: www.worthingtonu.com

Revision 10/24/2012

Page 2: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

This Presentation was created by the good folks at Worthington Distribution and adapted for distribution to ELAN g!

dealers to aide in their Z-Wave education.

Worthington Distribution carries all of the Z-Wave locks and peripherals and offers great technical support to its’ customers.

Page 3: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

• Always Follow• National Code• State Code• Local Code• National Electric Code (NEC)• When No Code Exists the Code Defaults to the NEC

• Licensing and Insurance• What are the Licenses Required?• Are Employees Covered for Electrical and other Trade

Work?• Worthington University Classes Are A Complement To But

Not A Replacement For Manufacturer Trainings• Always Consult Product Manuals And Follow Safety

Warnings• Do Not Make Product Modifications Or Alterations• Install All Product In Accordance With UL And CE Listings

Code, Insurance and Installation

Page 4: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

• Worthington University Training Documents Are A Complement To But Not A Replacement For Manufacturer Trainings• Always Consult Product Manuals And Follow Safety

Warnings• Do Not Make Product Modifications Or Alterations• Install All Product In Accordance With UL And CE Listing

Manufacturer Instructions

Page 5: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

What Can Do?• ELAN g! controllers support two-way integration

with locks • The g! controllers can lock and unlock the locks

and monitor changes in the states of the locks • Provide convenient user code management • Extensive event triggering allows the state of the

lock can be used as a condition in automation programming

• Lock control is supported in all g! interfaces• TS7/TS10 touchscreens• iOS & Android devices• HR2 & TS2• PC viewer

Page 6: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

• Lock status only reflects the status of the lock, not the door.• A deadbolt can be extended if the door is open. An entry set door must be closed to

be secure.• *Schlage deadbolts must be manually turned, the deadbolt is not motorized• *Schlage entry sets can be locked/unlocked via command when the key is in the locked

position• When a Schlage entry set is manually unlocked with a key, the lock/unlock state is

not correctly represented. A lock command will not lock the door, the state will show as locked.

• A Schlage manual key unlock override on the entry set is not reported to the HAI via Z-Wave

Supported Locks

Deadbolt Entry Set

Entry Set

Deadbolt

Deadbolt

Deadbolt

Touch

Deadbolt

Pad

Deadbolt

Entry Set

Technology Z-Wave ZigBee

HA

Z-WaveZigBee

HA

Z-WaveZigBee

HA

Z-Wave ZigBee

HA

Z-Wave ZigBee

HA

Z-Wave Z-Wave

Motorized Lock/Unlock

Y Y Y Y Y N* N*

Lock Status Y Y Y Y Y Y Y/N*Pinpad / Key reports Y Y Y Y Y Y Y/N*

User Codes 30 30 30 250 (30 supported

by g!)

250 (30 supported

by g!)

19 19

Batteries 4-AA 4-AA 4-AA 4-AA 4-AA 3-AA,1-9V

4-AA

Deadbolt DeadboltEntry Set Deadbolt Deadbolt

Page 7: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Baldwin Finishes

(soon)

Boulder Style Deadbolts

BD8252102AC3Z-Wave

Oil Rubbed Bronze

BD8252003AC3Z-Wave

Polished Brass

BD8252112AC3Z-Wave

Venetian Bronze

BD8285150AC3Z-Wave

Oil Satin Nickel

BD8285056AC3Z-Wave

Lifetime Satin Nickel

BD8285260AC3Z-Wave

Polished Chrome

SOHO Style Deadbolts

BD8252402AC3Z-Wave

Distressed Oil Rubbed Bronze

BD8285264AC3Z-Wave

Satin Chrome

Page 8: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Kwikset FinishesDeadbolts

BD99100-006Z-Wave

Venetian Bronze

BD99100-005Z-Wave

Satin Nickel

BD99100-004Z-Wave

Polished Brass

Contemporary Deadbolts Entry Set

BD99100-014Z-Wave

Venetian Bronze

BD99100-011Z-Wave

Satin Nickel

BD99100-012Z-Wave

Satin Chrome

BD99100-013Z-Wave

Polished Chrome

BD99100-006Z-Wave

Venetian Bronze

BD99100-005Z-Wave

Satin Nickel

BD99100-004Z-Wave

Polished Brass

Page 9: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Yale FinishesCapacitive Touch

Deadbolts

YALD220ZW0BPZ-Wave

Oil Rubbed Bronze

YALD220ZW619Z-Wave

Satin Nickel

YALD220ZW605Z-Wave

Bright Brass

YALD210ZW0BPZ-Wave

Oil Rubbed Bronze

YALD210ZW619Z-Wave

Satin Nickel

YALD210ZW605Z-Wave

Bright Brass

PinpadDeadbolts

(soon)

Page 10: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Schlage FinishesDeadbolts

SCHBE369716Z-Wave

Aged Bronze

SCHBE369619Z-Wave

Satin Nickel

SCHBE369505Z-Wave

Bright Brass

SCHFE599716Z-Wave

Aged Bronze

SCHFE599619Z-Wave

Satin Nickel

SCHFE599505Z-Wave

Bright Brass

Entry Set

Page 11: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Are ZigBee and Z-Wave the Same? Both are mesh network

• All products can be on the same network

• Basic interoperability for all products

• Very large number of currently shipping interoperable products

• 1 Chip manufacturer• Locks from Kwikset, Yale,

Baldwin and Schlage currently shipping

• New HA Profile is creating a protocol layer for interoperability

• HA Profile products are starting to ship from HAI, Centralite and coming from Somfy

• Multiple chip manufacturers building to an IEEE standard

• HA Profile locks coming from Kwikset, Baldwin and Yale• Currently shipping ZigBee

locks are not HA Profile

Page 12: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Z-Wave Setup•Leviton Vizia rf+ Installer

Software•Lock Inclusion•2-Way Communication Setup

• Worthington Distribution recommends Z-Wave technology in traditional wood frame residential applications up to 7,500 sq/ft.

• For unusual applications, give us a call.

Page 13: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Getting Started: What You Will Need• Z-Wave lock compatibility

• g!5.9 and above• Leviton VRCOP Serial interface

• It must be a ‘3’ series (see image)• Firmware must be updated

• All VRCOP units sent from Worthington Distribution as of 1/1/2012 is updated and a sticker is added to the box before shipment (see image)

• Firmware updates for the VRCOP ‘3’ series can be updated from Leviton.com (Click on Home Automation)

• Use a Leviton VRUSB-1US USB programming stick (pictured)

Is your VRCOP compatible?Look on the back for ‘vizia rf+ 3’

Worthington Distribution is updating serial interfaces before shipping (as of 1/1/2012).

Look for the sticker above on the box

The Leviton USB stick is needed for use with the Vizia RF+ Installer software

Page 14: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

vizia rf+ Installation Software

• The software is free• Locks require 1.1.0.0 or later• Download from

www.leviton.com/rfinstaller• A LEVVRUSB-1US USB stick is required

Page 15: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Z-Wave Overview•Z-Wave Technology•Expanding Communication Coverage•Beaming Command•Best Practices

Page 16: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

• Networking technology to route information between devices

• Allows reconfiguration around blocked paths by "hopping“

• Mesh network• No repeaters required• More devices = better coverage

• Estimated 75’ (open air) range between devices• Results vary based on construction and

environment, 35’+ installed distance is typical• Self-healing: network can still operate even when a

device breaks down or a connection goes bad• 900MHz frequency at 9.6K and 40K baud• Only uses devices that have been programmed into

the network• Enough devices must be in network for sufficient

coverage

Z-Wave Mesh Networking

Page 17: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

More modules = Better Coverage• Z-Wave is a mesh network

• AC Powered devices can repeat transmissions to reach devices that the serial module can not reach directly

• Worthington Distribution has found Z-Wave to be effective in traditionally constructed homes up to 7,500

R3R2R1

R4

• Z-Wave devices that are running on batteries DO NOT repeat Z-Wave commands• Examples: Locks and battery

powered thermostats

Page 18: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Choose Modules with Beaming• Understanding Beaming is critical to success with locks

• When the serial module is unable to talk directly to a lock it will need the assistance of other AC powered (non-battery) devices in the network to repeat the messages

• ONLY DEVICES WITH BEAMING SUPPORT CAN WAKE A LOCK• Beaming is required to ‘wake-up’ 2-way battery devices

• Many (most) shipping Z-Wave devices do not feature beaming support• All devices with new chipsets include beaming support; however, not all

products feature the new chips• Without beaming, the locks will not communicate no matter how many

non-beaming devices are added to the network• Beaming communication does have noticeable delay

Beam Beam CommandCommand

Wake Up!Wake Up!Serial Interface

Device with Beaming support

Lock

Page 19: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Known Products With Beaming• As of October 24, 2012 the current shipping versions

of the following products are known to have Beaming support.

LEVVRP03Lamp Module

LEVVRC0PSerial Interface

LEVVRCS4-M0vizia rf+ 4 ButtonScene Controller

LEVVRCZ4-M0vizia rf+ 4 ButtonZone Controller

EVOLDM-15Plug-in Lamp module

EVOLPM-15Plug-in Appliance module

EVOLRM-ASDecorator style dimmer

EVOLSM-15Decorator style switch

EVOLOM-15Wall Outlet

Leviton vizia rf+ is fully compatible with HAI controllers and features automatic status updates

Note:

Evolve devices can be controlled by HAI; however, status must be polled

Note:

Page 20: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

• Exterior materials can effect signal• Examples

• Aluminum siding• Wire mesh – stucco and stone• Foil backed installation• Low-E Glass

• Low temperatures are a concern

Stay away from controlling devices mounted outdoors and in outbuildings

Z-Wave Best Practices

Page 21: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

• Best practice is to expand coverage in pairs• More options allows the mesh to try alternate paths• The temptation when expanding coverage is to just add

a single device half way. While this has been known to work, for consistent results add 2 devices around the halfway point.

• When using plug-in modules, choose locations that are unlikely to be unplugged or moved• Behind furniture is often a great location• If out of site, label “Communication Device, Do Not

Remove”• Once placed and programmed DO NOT RELOCATE

ZWAVE DEVICES

Z-Wave Best Practices

Page 22: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Z-Wave is RF: Think Metal!

• Z-Wave uses RF signals• Metal reflects signals• Metal does not mean it will not work, just be aware of

large metal objects and plan accordingly• Metal junction boxes effect RF transmission patterns

• Often more devices are needed for the same coverage

• Do not place the Leviton Z-Wave Serial Interface in a metal structured wiring enclosure or equipment rack

Page 23: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Z-Wave Programming

Page 24: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Create A New File

• Start by creating a new file• The USB stick will be reset• You will be prompted for a new file

name

Page 25: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Learn the Locks

Exclude before Include•It is a good habit to Exclude a device prior to Including it in your new Zwave network

• In enough cases to be troublesome a device is tested on the production line but not removed from their test network

• This causes issues with learning the lock into a new network

•Excluding a device is very similar to including a device. Start by selecting Exclude Device then skip to the instructions for your lock

Install First•Install the locks in the FINAL location before enrolling

• It is NOT advisable to learn the locks and then install them•Once you hit OK, use the following slides for the proper enrollment procedure

Page 26: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Learn The LocksInclude•After Excluding you may now Include•Select Include Device and press “OK” BEFORE putting the lock into include mode•See the slide for your device for setting it to include

Page 27: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Learning Kwikset and Baldwin• Install the locks in the FINAL location before enrolling

• It is NOT advisable to learn the locks and then install them• Ensure you have fresh batteries and that a green Z-Wave radio is

installed• A non-communicating version of the lock is available in which a

radio is not installed. The RF cards are not available separately.• A ZigBee radio is red and is not compatible with Z-Wave products

• When the lock is powered up, follow the instructions to set user code 1• Press the big button (circled in red) one time• Enter a code • Press the lock button

• As shown in the previous slide, click ‘Include Device’• When the dialog box pops up, press ‘OK’

• Press the top left microswitch (finger pointing on the left)• The blue LED on the USB stick will flash, it can take 30 seconds for a

lock to enroll• Give the lock a name• Repeat for additional locks• If for any reason the lock will not learn, click ‘Exclude Device’ and then

the Microswitch. Once removed from all networks, attempt Inclusion again.

Page 28: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Learning Yale• Install the locks in the final location before enrolling

• It is not advisable to learn the locks and then install them• Ensure you have fresh batteries• When the lock is powered up you have to set an installer code

• Enter 12345678#• Enter 1#• Enter an Installer Code (4-6 digits) followed by #

• As shown in the previous slide, click ‘Include Device’• When the dialog box pops up, press ‘OK’

• Learn in the deadbolt• Enter the new Installer Code followed by #• Enter 7#• Enter 1#

• The blue LED on the USB stick will flash, it can take 30 seconds for a lock to enroll

• Give the lock a name• Repeat for additional locks• If for any reason the lock will not learn, click ‘Exclude Device’

• Enter the new Installer Code followed by #• Enter 7#• Enter 3#• Once removed from all networks

attempt Inclusion again

Page 29: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Learning Schlage• Before installing, write down the Prog and User Codes on the yellow

sticker (below)• Install the locks in the final location before enrolling

• It is not advisable to learn the locks and then install them• Ensure you have fresh batteries

• The deadbolt has 2 sets of batteries• 3 AA power the Z-Wave radio and 9V controls the lock/pinpad

• As shown in the previous slide, click ‘Include Device’• When the dialog box pops up, press ‘OK’

• Type the Prog Code in on the Pinpad• The Schlage logo will turn Amber• Press 0

• The blue LED on the USB stick will flash, it can take 30 seconds for a lock to enroll

• Give the lock a name• Repeat for additional locks• If for any reason the lock will not learn, click ‘Exclude Device’ and then

type the Prog Code followed by 0• Once removed from all networks attempt Inclusion again.

Page 30: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Additional Devices for Communication• Many installations will require additional Z-

Wave modules to ensure reliable communication

• Beaming compatible devices are required• See slide 19

• Plug-in lamp and appliance modules have been popular with other installers

• Pro: Quick installation with no electrical license required

• Con: The customer can move or unplug the modules

• Light switches and outlets provide a more custom installation

• Pro: Devices are not going to move and customers often request more devices once they can control lights on a schedule and from portable devices

• Con: Devices should be installed by an electrician

R3R2R1

R4

Page 31: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

• Programming• Click Include Device• Click OK and wait 2 seconds

• The LED on the stick will flash for a moment

• Follow the Include Device instructions for the device

• Leviton – Tap the device on• Evolve – Double tap the

device on• Once all additional devices are

added• Right mouse click on the

serial interface• Now has a green box

Additional Devices for Communication

Page 32: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Add the Leviton Serial Interface• It is best to have the locks installed and learned before adding the serial

interface• If a lock is added after learning in the serial, simply repeat the serial

learning process• Put the VRC0P interface into learning BEFORE pressing ‘Include Device’ on the

PC• With the LED flashing green, press and hold the LED until it turns amber

• If the LED turns amber and then red, the serial is defaulted. Just wait until the LED turns green again and start over

• With the LED flashing amber, click ‘Include Device’ followed by clicking ‘OK’ when the dialog box pops up

• Once included, give the serial interface a name like ‘serial interface’

Page 33: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Set the Serial Interface For 2-Way• Before executing this step, the locks must be in the network and the serial interface should

be learned in last

• Choose Diagnostics / RS232 Setup

• The LevSerialInterfaceConfig dialog box will open• Use the pull down next to RS232 Modules and choose the

serial interface connected to the HAI• Place a check mark next to each lock• Click Set Association• The Set Association button will gray out during communication

• Be patient, this can take a minute or two• The blue LED on the USB stick will flash

• The process is complete when the Set Association buttonis no longer grayed out. You can now close the dialog box.

Page 34: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Note the Node Numbers• The last step before closing the software is to note the node numbers for

each lock• g! imports all the devices automatically but does not import device

names• In the upper left corner, expand the ‘All Devices’ section in the tree

• Note the device name and node numbers shown in the parenthesis ()

Page 35: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

USB Stick Orientation• RF devices often do not radiate evenly in all directions• The USB stick radiates out the sides more than the end

• Typically this is a non-issue except in very close range applications

• The time to be aware of the USB stick radiation pattern is when you have a laptop cradled in your arm

• If the USB stick is in the back, installers like to get the stick near the target device; unfortunately, that puts the device right in the ‘blind spot’

• Point the side of the stick towards the device for better results

Blind spot atclose

distance

Not recommended Much better

Page 36: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

A Device Will not learn• In current Z-Wave versions, a device must be

within the standard (3’) or long range (75’ open air) inclusion circle during the learning phase• Depends on when the device was designed• Beaming devices typically support long

range inclusion• If other devices will be needed to ‘hop’ to the

USB stick then it will likely not learn• It is best to have the PC and stick in the

room when learning• This is most important with locks

R3R2R1

R4

Page 37: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

When Things Go Wrong: Static Routes•Z-Wave is an excellent technology; however,

like many technologies, it is only as good as the installation

•Static Routes•Z-Wave is a mesh network that

depends on other devices in the network to ensure commands get to their destination

•Learning devices into the USB stick establishes the paths

•Removing or Moving a device disrupts the path and causes serious issues

R3

R2

R1

R4

Page 38: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Rediscovery• Z-Wave paths are critical to success• Paths are traditionally established during the learn

process• Rediscovery establishes new paths using devices

currently assigned to the network• Start by learning all of the devices into the USB

stick• Place the devices in their final location• Use the rediscovery feature

• Update the VRC0P using ‘Update Routes’ after rediscovery

R3R2

R1

R4

Page 39: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Rediscovery Power Level• Choose Power Level

• The Power Level is useful for ensuring there is ‘room for error’ when routes are chosen

• Lowering Power Level means devices transmission range is lowered as routes are discovered so fewer devices are available

• The devices chosen for routes during low power rediscovery will have high signal strength during normal operation

• Choosing a power level• In typical installations, start with -6dB• The only exception is when the home has a large

amount of Z-Wave (every light switch in the home)• A low Power Level will cause the system to hop

more than it needs to resulting in slower communication

• Start the Network Rediscovery• If you start with -6dB and all devices don’t pass,

try -4dB• If -4dB does not pass you likely need more

modules• Always update the serial interface after a Network

Rediscovery

Page 40: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Update Routes• When a Rediscovery is used the serial needs to be

updated• The serial update allow the serial to use the new

paths that were discovered• After the serial has been updated, the locks need to be

offered the newly discovered pathways for speaking back to the serial

• Under Diagnostics choose Update Routes• Check each lock• Click Update Routes

Page 41: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Time for g!• Connect the VRC0P to your ELAN g! controller

using the white serial cable and see the ELAN Zwave Door Locks integration note to complete programming

Page 42: ZWave Lock Programming

Property of Worthington Distribution.May Not Be Reproduced Without Permission

800-282-8864

Worthington Distribution• Worthington Distribution Can Provide

• Product

• Competitive Pricing

• Great Stocking Levels in Tafton, PA

• Knowledgeable, Helpful Staff

• Training

• Worthington University

• On-Line

• Technical Support

• System Design Support

800-282-8864

Richard Scholl

President

Richie SchollVP, Technical

Sales

Debbie SchollCustomer Service

Tom MorganVP,

Worthington University

Steve HohTechnical Support

Barry HampeTechnical Support

Tricia SeyboldCustomer Service

Manager

Nolan MaleTechnical Support