Top Banner
Simply Smart! Timers, counters, control and analogue interfaces Zelio Time, Count, Control, Analogue Confidence can be measured
12

Zelio Brochure Eng

Apr 21, 2015

Download

Documents

Cesar Gutierrez
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Zelio Brochure Eng

Simply Smart!

Timers, counters, control andanalogue interfaces

Zelio Time, Count, Control,AnalogueConfidence can be measured

Page 2: Zelio Brochure Eng

Simply Smart!Leveraging

ingenuity

and intelligence

for ease of use

Zelio Count

XBK counters, when associated with sensing products,assure a complementary counting function within automationsystems. A variety of simple functions, displays and settingsare available in two technologies and three product families:■ XBKH: hour counting■ XBKT: totalizers■ XBKP: threshold preselectors

Zelio Time, Cou

Zelio Time

Our complete and high-performance electronic timerconforms to international standards and corresponds exactlyto your requirements. It is designed for all hard-wired logicautomated systems complementing programmable logiccontrollers. Ergonomic and configurable Zelio timers areavailable in 3 versions: modular, industrial, panel-mounted.

2

Page 3: Zelio Brochure Eng

nt, Control and Analogue

Zelio Control

Zelio Control covers all monitoring and control requirements.This range is “in phase” with industrial control systems,guaranteeing detection of breakdowns and faults. It enablesthree-phase network monitoring, AC and DC current andvoltage measurement, and handles conducting liquidlevel control.

Zelio Analogue

Zelio Analogue converters are designed to convert signalsemitted by sensors or electrical measurements into standardelectrical signals which are compatible with automationplatforms and controllers (thermal processes and speed).They also increase the connection distance between asensor and the measurement acquisition device (eg.between a thermocouple and a programmable controller).

3

Page 4: Zelio Brochure Eng

Multifunction (1) :Timer on-delay / Timer on-delaywith time lock control / Calibrator /Timer off-delay with control /Pulse on energization / Pulse onenergization with time control lock /Symmetrical flasher starting bypause or pulse.

Multifunction (2) :Multifunction (1) and timeron-delay then timer off-delay byexternal control / Externallycontrolled differentiator.

Multifunction (3) :Timer on-delay by external control/ Single cycle flasher by control /Watchdog / Delayed watchdog /Delayed fixed pulse / Delayed fixedpulse with time lock control /Remote switch / Time delay remoteswitch / Timer off-delay whenexternal control disappears.

Zelio TimeModular Relays

RE11 range

The new timing relay offer presents a majorsize advantage with its width of 17.5 mm.

■ Compact dimensions – only 17.5 mm wide.■ Single or multifunction ranges are available.■ Wide power supply range.■ Time range: 0.1 s to 100 h.■ Relay or solid-state output.■ Settings are protected by a sealable plastic cover.■ Simple to instal wiring and timing diagrams are

located on side of relay.

Spring terminals and settings are protected by a sealable plastic cover. Wiring and timing diagrams are located on side of relay.

POWER SUPPLY TIME RANGE CAT. NUMBERSTERMINALSOUTPUTFUNCTIONS

1 relay 8A1 relay 8A1 relay 8A1 relay 8A1 relay 8A1 relay 8A1 relay 8A1 relay 8A1 relay 8A1 relay 8A1 relay 8A1 relay 8Astatic 0.7Astatic 0.7Astatic 0.7Astatic 0.7Astatic 0.7A

RE11 RA MURE11 RB MURE11 RH MURE11 RC MURE11 RL MURE11 RL JURE11 RME MURE11 RM MWRE11 RM MURE11 RM MWSRE11 RM JURE11 RMX MURE11 LA MWRE11 LH BMRE11 LC BMRE11 LL BMRE11 LM BM

24 VDC & 24 to 240 VAC24 VDC & 24 to 240 VAC24 VDC & 24 to 240 VAC24 VDC & 24 to 240 VAC24 VDC & 24 to 240 VAC12 VAC / DC24 VDC & 24 to 240 VAC12 to 240 VAC / DC24 VDC & 24 to 240 VAC12 to 240 VAC / DC12 VAC / DC24 VDC & 24 to 240 VAC24 to 240 VAC/DC24 to 240 VAC24 to 240 VAC24 to 240 VAC24 to 240 VAC

0.1 s to 100 h0.1 s to 100 h0.1 s to 100 h0.1 s to 100 h0.1 s to 100 h0.1 s to 100 h0.1 s to 10 h0.1 s to 100 h0.1 s to 100 h0.1 s to 100 h0.1 s to 100 h0.1 s to 100 h0.1 s to 100 h0.1 s to 100 h0.1 s to 100 h0.1 s to 100 h0.1 s to 100 h

screwscrewscrewscrewscrewscrewscrewscrewscrewspringscrewscrewscrewscrewscrewscrewscrew

Timer on-delayCalibratorPulse on energizationTimer off-delay with control

Multifunction (1)

Multifunction (3)Timer on-delayPulse on energizationTimer off-delay with control Asymmetrical flasherMultifunction (2)

Asymmetrical flasher

Multifunction (2)

Compact size/Accurate settings/Wiring and operating diagrams visible on product/UL, CSA and GL certified

17.5 mm

4

Page 5: Zelio Brochure Eng

Multifunction (4) :Timer on-delay / Timer off-delay /Pulse on energization / Pulse onopening control / Symmetricalflasher starts by pause or pulse.

* 1 selectable in instantaneous** with common point

Zelio TimeIndustrial Relays

RE7 range

The 22.5 mm industrial range is perfectly suitedto user requirements.

■ Standard dimensions: 22.5 mm W, 78 mm H, 80 mm D.■ Settings are protected by a sealable plastic cover.■ External control is possible for:

v start of time delayv partial stop of time delayv adjustment of time delay

■ Simple and quick installation. Wiring and timingdiagrams are located on side of relay.

■ Wide time range (up to 300 hours).■ Application adaptation (7 time delay choices).■ Two 8 A outputs

(second output instantaneous or time delay).■ LEDs indicate time delay.■ Screw or spring connection.■ Wide voltage range (24 to 240 VAC/DC).■ Mounting on DIN rail or by screw without adapter plate.■ Compact size.■ UL, CSA and GL certified.

Settings are protected by a sealable plastic cover.

Wiring and timing diagrams are located on side of relay.

POWER SUPPLY TIME RANGE CAT. NUMBERSOUTPUTFUNCTIONS

RE7TL11BURE7 TM11BURE7 TP13 BURE7 MA11BURE7 MA13BURE7 MV11BURE7 RB11MWRE7 RB13MWRE7 RA11BURE7 RM11BURE7 RL13BURE7 PE11BURE7 PP13BURE7 PM11BURE7 PD13BURE7 CL11BURE7 CP13BURE7 CV11BURE7 YA12BURE7 YR12BURE7 ML11BURE7 MY13BURE7 MY13MW

24VAC/DC - 110 to 240 VAC24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC24 to 240 VAC / DC24 to 240 VAC / DC24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC24VAC/DC - 110 to 240 VAC24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC24VAC/DC - 110 to 240 VAC24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC24VAC/DC - 110 to 240 VAC - 42 to48 VAC/DC24VAC/DC - 110 to 240 VAC24 to 240 VAC /DC

0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h0.05 s to 10 m0.05 s to 10 m0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h0.05 s to 300 h

1 relay 8 A1 relay 8 A2 relay 8 A*1 relay 8 A2 relay 8 A*1 relay 8 A1 relay 5 A2 relay 5 A*1 relay 8 A1 relay 8 A2 relay 8 A*1 relay 8 A2 relay 8 A*1 relay 8 A2 relay 8 A*1 relay 8 A2 relay 8 A*1 relay 8 A2 relay 8 A2 relay 8 A**1 relay 8 A2 relay 8 A*2 relay 8 A*

Timer on-delay

Timer on-delay and off-delayControl by external contact

Timer off-delayon de-energizationTimer off-delay control opening(low level)(low level)

Timer off-delay at on removal ofexternal control

Asymmetrical flasherStar-delta starting time delayStar-delta starting time delayMultifunction (4)Multifunction (4)Star-delta starting time delay

Pulse on energization

Symmetrical flasher (off start)

Voltage markings on terminal blocks/Accurate SettingsWiring and operating diagrams visible on product/UL, CSA and GL certified

5

Page 6: Zelio Brochure Eng

Multifunction (5) :Timer on-delay /Pulse on energization

Multifunction (6) :Timer on-delay / Calibrator /Timer off-delay / Symmetricalflasher

* 1 selectable to instantaneousmode

Zelio TimePanel-mounted Relays

RE48 Range

The new range of plug-in timing relays in a48 x 48 format is especially designed forintegration in machines and equipment,for any application requiring frequent cycletime adjustment or setting.

■ Ergonomic design.■ Direct reading.■ Multifunction.■ Multivoltage: 24 to 240 VAC-DC.■ Wide time range: 0.02 to 300 h.■ Mounting spring supplied as standard.■ Connection sub-bases as option.

Wiring diagram located on relay side.

Flush-mounted.

Readability: direct reading.

POWER SUPPLY TIME RANGE CAT. NUMBERSOUTPUTFUNCTIONS PINS SUB-BASES

2 relay 5 A2 relay 5 A2 relay 5 A*2 relay 5 A

RE48A TM12MWRE48A CV12MWRE48A MH13MWRE48A ML12MW

24 to 240 VAC/DC24 to 240 VAC/DC24 to 240 VAC/DC24 to 240 VAC/DC

0.02 s to 300 h0.02 s to 300 h0.02 s to 300 h0.02 s to 300 h

811811

RUZ1DRUZ1ARUZ1DRUZ1A

Timer on-delayAsymmetrical flasherMultifunction (5)Multifunction (6)

Easy to Configure/Accurate settings/Plug-in/UL, CSA and GL Certified6

Page 7: Zelio Brochure Eng

Zelio CountElectronic andElectromechanical Counters

Electronic

■ LCD or LED display and fastinput counter (≤ 7.5 kHz).

■ User-friendly display.■ Counting frequency.■ Configurable product (input

type, mode, output…).■ Internal battery.■ With or without reset to zero.■ Three sizes: 24 x 48 mm,

48 x 48 mm and 72 x 72 mm.

Electromechanical

■ Mechanical display and slowinput counter (≤ 25 kHz).

■ Permanent display.■ Immunity against electrical

and magnetic interference.■ Economical solution.■ With or without reset to zero.■ Two sizes: 24 x 48 mm and

48 x 48 mm.

Simple/Rugged/UL listed

XBKH70000004MXBKH70000002MXBKH81000033E

Mechanical 7-digit

LCD 8-digit

24 VAC230 VACBattery

POWER SUPPLY

50 Hz50 Hz1/100 h

FREQUENCY CAT. NUMBERS

withoutwithoutmanual*

RESETDISPLAY

48 x 48 mm48 x 48 mm48 x 24 mm

DIMENSIONS

XBKH Range hour counters*

Counts elapsed time in hours and 1/100 hoursand displays / updates values.

Mechanical

LCD

5-digit6-digit6-digit8-digit8-digit

manualwithoutmanualwithoutmanual*

XBKT50000U10MXBKT60000U00MXBKT60000U10MXBKT80000U00MXBKT81030U33E

24 VDC24 VDC24 VDC24 VDCBattery

20 Hz10 Hz25 Hz25 Hz7.5 kHz

41.5 x 31 mm30 x 20 mm60 x 50 mm60 x 50 mm48 x 24 mm

POWER SUPPLY FREQUENCY CAT. NUMBERSRESETDISPLAY DIMENSIONS

XBKT Range totalizers*

Counts electrical pulses or contact and displays/updatesvalue at each pulse; uni-directional.

manual, electrical, automaticmanual, electrical, automaticmanual, electrical, automaticmanual, electrical, automaticmanual, electrical, automaticmanual, electrical, automaticmanual, electrical, automaticmanual, electrical, automaticmanual, electrical, automaticmanual, electrical, automatic

XBKP61130G30EXBKP61130G31EXBKP61130G32EXBKP61230G30EXBKP61230G31EXBKP61230G32EXBKP62130G30EXBKP62130G32EXBKP62230G30EXBKP62230G32E

24 VDC115 VAC230 VAC24 VDC115 VAC230 VAC24 VDC230 VAC24 VDC230 VAC

5 kHz5 kHz5 kHz5 kHz5 kHz5 kHz5 kHz5 kHz5 kHz5 kHz

LCD 6-digit

LED 6-digit

48 x 48 mm48 x 48 mm48 x 48 mm48 x 48 mm48 x 48 mm48 x 48 mm48 x 48 mm48 x 48 mm48 x 48 mm48 x 48 mm

1112221122

POWER SUPPLY FREQUENCY CAT. NUMBERSRESET TYPE DISPLAY DIMENSIONS PRESELECTIONS

XBKP Range multifunction counters*

Upcounts or downcounts electrical pulses or contact. Displays and updates value andtransmits an electrical signal when preselected threshold is reached.

7

* Not CSA certified. (For export only)

Page 8: Zelio Brochure Eng

Zelio ControlMonitoring andControl Relays

Simplicity/Performance/Compact Size/Safety/UL, CSA and GL Certified

RM4UA/B Voltagemeasurementfunction

■ Under/overvoltage■ Adjustable timing■ 50 mV - 500 V

■ DC motor overspeedmonitoring

■ Battery monitoring

■ Network and powersupply monitoring

■ Speed monitoring

RM4J Currentmeasurementfunction

■ Under/overcurrent■ 3 mA - 15 A■ Adjustable timing

■ Measurement ofcurrent drawn by a3-phase motor

■ Heating and lightingcircuit monitoring

■ Pump de-energizingmonitoring

■ Overtorque monitoring■ Mechanical brake and

clutch monitoring

FUNCTIONS RANGES TIME RANGE OUTPUT CAT. NUMBERSPOWER SUPPLY

---0.05 to 30 s0.05 to 30 s0.05 to 30 s0.05 to 30 s0.05 to 30 s0.05 to 30 s0.05 to 30 s0.05 to 30 s

1 relay 8 A1 relay 8 A1 relay 8 A2 relay 8 A2 relay 8 A2 relay 8 A2 relay 8 A2 relay 8 A2 relay 8 A2 relay 8 A2 relay 8 A

RM4 JA01BRM4 JA01FRM4 JA01MRM4 JA31MWRM4 JA31FRM4 JA31MRM4 JA31QRM4 JA32MWRM4 JA32FRM4 JA32MRM4 JA32Q

3 ... 30 mA 10 ... 100 mA 0.1... 1A

3 ... 30 mA 10 ... 100 mA 0.1... 1 A

0.3 ...1.5 A 1 ... 5 A 3 ...15 A

Overcurrent

Over or undercurrent

Over or undercurrent

24 VAC110 ... 130 VAC220 ... 240 VAC24... 240 VAC/DC110 ... 130 VAC220 ... 240 VAC380 ... 415 VAC24... 240 VAC/DC110 ... 130 VAC220 ... 240 VAC380 ... 415 VAC

FUNCTIONS RANGES TIME RANGE OUTPUT CAT. NUMBERSPOWER SUPPLY

---------0.05 to 30 s0.05 to 30 s0.05 to 30 s0.05 to 30 s0.05 to 30 s0.05 to 30 s0.05 to 30 s0.05 to 30 s0.05 to 30 s0.05 to 30 s0.05 to 30 s0.05 to 30 s

0.1 to 10 s

0.1 to 10 s

1 relay 8 A1 relay 8 A1 relay 8 A1 relay 8 A1 relay 8 A1 relay 8 A1 relay 8 A1 relay 8 A1 relay 8 A2 relay 8 A2 relay 8 A2 relay 8 A2 relay 8 A2 relay 8 A2 relay 8 A2 relay 8 A2 relay 8 A2 relay 8 A2 relay 8 A2 relay 8 A2 relay 8 A

2 relay 8 A

2 relay 8 A

RM4 UA01BRM4 UA01FRM4 UA01MRM4 UA02BRM4 UA02FRM4 UA02MRM4 UA03BRM4 UA03FRM4 UA03MRM4 UA31MWRM4 UA31FRM4 UA31MRM4 UA31QRM4 UA32MWRM4 UA32FRM4 UA32MRM4 UA32QRM4 UA33MWRM4 UA33FRM4 UA33MRM4 UA33Q

RM4 UB34

RM4 UB35

<U : 80...120 VAC>U : 160...220 VAC<U : 160...220 VAC>U : 220...300 VAC0.05 V... 0.5 V0.3 V... 3 V0.5 V... 5 V 1 V... 10 V 5 V... 50 V10 V...100 V

30 V...300 V50 V...500 V

0.05 V... 0.5 V0.3 V...3 V0.5 V...5 V

1 V... 10 V 5 V... 50 V10 V...100 V

30 V...300 V50 V...500V

Undervoltage or overvoltage

Undervoltage or overvoltage

Undervoltage or overvoltage

Undervoltage and overvoltage

Overvoltage

Overvoltage

Overvoltage

Self-powered 100...200 VAC

Self-powered 180...270 VAC

24 VAC110...130 VAC220...240 VAC24 VAC110...130 VAC220...240 VAC24 VAC110...130 VAC220...240 VAC24...240 VAC/DC110...130 VAC220...240 VAC380...415 VAC24...240 VAC/DC110...130 VAC220...240 VAC380...415 VAC24...240 VAC/DC110...130 VAC220...240 VAC380...415 VAC

U

I

8

Page 9: Zelio Brochure Eng

Zelio ControlMonitoring andControl Relays

Simplicity/Performance/Compact Size/Safety/UL, CSA and GL Certified

FUNCTIONS RANGES TIME RANGE OUTPUT CAT. NUMBERSPOWER SUPPLY

---

0.5 s fixed0.5 s fixed0.1 to 10 s0.1 to 10 s

0.1 to 10 s

0.1 to 10 s

0.1 to 10 s

0.1 to 10 s

2 relay 8 A2 relay 8 A2 relay 8 A

1 relay 8 A1 relay 8 A2 relay 8 A2 relay 8 A

2 relay 8 A

2 relay 8 A

2 relay 8 A

2 relay 8 A

RM4 TG20RM4 TU01RM4 TU02

RM4 TA01RM4 TA02RM4 TA31RM4 TA32

RM4 TR33

RM4 TR34

RM4 TR31

RM4 TR32

220 - 440 VAC 160 - 220 VAC300 - 430 VAC< 198 V (fixed)> 242 V (fixed)< 360 V (fixed)> 440 V (fixed)<U : 160...220 VAC>U : 220...300 VAC<U : 300...430 VAC>U : 420...480 VAC5...15%5...15%5...15%5...15%

Phase loss and sequence

Phase loss, sequence and voltage unbalance

Phase loss, sequence and undervoltage

Phase loss, sequence and undervoltage /overvoltage

Self-poweredSelf-powered 200...240 VACSelf-powered 380...440 VAC

Self-powered 200...240 VACSelf-powered 380...440 VACSelf-powered 220...240 VACSelf-powered 380...440 VAC

Self-powered 220 VAC

Self-powered 400 VAC

Self-powered 220...240 VAC

Self-powered 380...440 VAC

FUNCTIONS RANGES MOUNTING OUTPUT CAT. NUMBERSPOWER SUPPLY

Socket Mounted

Surface Mounted

1 Relay, 5A1 Relay, 5A2 Relays 5A2 Relays 5A2 Relays 5A2 Relays 5A

8430MPSV248430MPSV298430MPDV208430MPDV248430MPDV298430MPDV32

Self powered 240V, 60HzSelf powered 480V, 60HzSelf powered 120V, 60HzSelf powered 240V, 60HzSelf powered 480V, 60HzSelf powered 600V, 60Hz

240V, 60Hz480V, 60Hz120V, 60Hz240V, 60Hz480V, 60Hz600V, 60Hz

Phase loss, Voltage unbalance, sequence, undervoltage

Phase loss, Voltage unbalance, sequence, undervoltage

RM4T Networkmonitoringfunction

■ Phase sequence■ Phase loss■ Unbalance■ Voltage measurement■ Adjustable timing■ 160 - 480 VAC

■ Connection of mobileequipment

■ Protection of personsand equipment againstreverse operation

■ Sensitive networks

■ Protection against riskof a driving load(phase loss)

■ Normal/emergencysource switching

RM4LA/G Liquidlevel function

■ 0.25 - 500 K ohms■ Adjustable timing■ 24 - 240 VDC■ 25 - 415 VAC

■ Conduction liquid levelregulation

■ Protection of pumpsand heaters againstrunning dry

■ Overfill sensing■ Filling/emptying

FUNCTIONS RANGES TIME RANGE OUTPUT CAT. NUMBERSPOWER SUPPLY

----0.1 to 10 s0.1 to 10 s0.1 to 10 s--

1 relay 8 A1 relay 8 A1 relay 8 A2 relays 8 A2 relays 8 A2 relays 8 A2 relays 8 A--

RM4 LG01BRM4 LG01FRM4 LG01MRM4 LA32MWRM4 LA32FRM4 LA32MRM4 LA32QLA9 RM201RM79 696 043

5...100 K

--

0.25... 5 K2.5... 50 K25... 500 K

Filling or emptying

Suspended probe 1 electrode + 1 réfProtected suspended probe

Filling or emptying

24 VAC110 ... 130 VAC220 ... 240 VAC24 ... 240 VAC/DC110 ... 130 VAC220 ... 240 VAC380 ... 415 VACby RM4 L....by RM4 L....

9

MPS and MPD relays (120 - 600 VAC)

Page 10: Zelio Brochure Eng

Zelio AnalogueAnalogue Interfaces

Zelio Analogue Converter and Transmitter

■ Pre-calibration of input and output ranges facilitateinstallation.

■ High repeatability of output signals as a function ofinput signal.

■ Outputs protected against polarity inversion,short-circuit and overvoltage.

■ Loop breakdown protection.■ Sealable protective cover.■ Conforms to UL/CSA/GL/EC standards.■ DIN rail or screw mounted.

Compact/Simple/Choice of outputs/UL, CSA and GL certified

INPUT / SCALE (Temp. Range) OUTPUT (Output Range) POWER SUPPLY (Voltage) CAT. NUMBERSDIMENSIONS (H/W/D - mm)

-40°…40°C-40°…104°F

0…10 V / 0…20 mA /4…20 mA Switchable

22.5 / 80 / 80 24 V DC Non Isolated RMPT10BD

-100°…100°C-148°…212°F

0…10 V / 0…20 mA /4…20 mA Switchable

22.5 / 80 / 80 24 V DC Non Isolated RMPT20BD

0°…100°C32°…212°F

0…10 V / 0…20 mA /4…20 mA Switchable

22.5 / 80 / 80 24 V DC Non Isolated RMPT30BD

0°…250°C32°…482°F

0…10 V / 0…20 mA /4…20 mA Switchable

22.5 / 80 / 80 24 V DC Non Isolated RMPT50BD

0°…500°C32°…932°F

0…10 V / 0…20 mA /4…20 mA Switchable

22.5 / 80 / 80 24 V DC Non Isolated RMPT70BD

UniversalPT 100

INPUT / SCALE (Temp. Range) OUTPUT (Output Range) POWER SUPPLY (Voltage) CAT. NUMBERSDIMENSIONS (H/W/D - mm)

-40°…40°C-40°…104°F 0…10 V 22.5 / 80 / 80 24 V DC Non Isolated RMPT13BD

-100°…100°C-148°…212°F 0…10 V 22.5 / 80 / 80 24 V DC Non Isolated RMPT23BD

0°…100°C32°…212°F 0…10 V 22.5 / 80 / 80 24 V DC Non Isolated RMPT33BD

0°…250°C32°…482°F 0…10 V 22.5 / 80 / 80 24 V DC Non Isolated RMPT53BD

0°…500°C32°…932°F 0…10 V 22.5 / 80 / 80 24 V DC Non Isolated RMPT73BD

OptimumPT 100

10

RMPT Converters for PT 100 probes

■ Converts the ohmic resistance 2, 3 or 4 wire PT 100probes to standard.

■ A preset temperature range for the inputs depending onthe model.

■ Switchable output of 0 - 10V, 0 - 20mA and 4 - 20mA.■ Optimum Pt100 converters have an output of 0-10V only.

19..30VDC2mA

OPG

A1V0

A2

0VDC

2-Wire

IP1

IP2PT100

IP3

IP4

IP1

IP2PT100

IP3

IP4

IP1

IP2PT100

IP3

IP4

IP1

IP2

IP3

IP4

3-Wire

4-Wire

Page 11: Zelio Brochure Eng

Compact/Accurate/Universal/UL, CSA and GL certified

Zelio AnalogueAnalogue Interfaces

INPUT / SCALE (Temp. Range) OUTPUT (Output Range) POWER SUPPLY (Voltage) CAT. NUMBERSDIMENSIONS (H/W/D - mm)

0°…150°C32°…302°F

0…10 V / 0…20 mA /4…20 mA Switchable

22.5 / 80 / 80 24 V DC Non Isolated RMTJ40BD

0°…300°C32°…572°F

0…10 V / 0…20 mA /4…20 mA Switchable

22.5 / 80 / 80 24 V DC Non Isolated RMTJ60BD

0°…600°C32°…1112°F

0…10 V / 0…20 mA /4…20 mA Switchable

22.5 / 80 / 80 24 V DC Non Isolated RMTJ80BD

0°…600°C32°…1112°F

0…10 V / 0…20 mA /4…20 mA Switchable

22.5 / 80 / 80 24 V DC Non Isolated RMTK80BD

0°…1200°C32°…2192°F

0…10 V / 0…20 mA /4…20 mA Switchable

22.5 / 80 / 80 24 V DC Non Isolated RMTK90BD

INPUT / SCALE OUTPUT (Output Range) POWER SUPPLY (Voltage) CAT. NUMBERSDIMENSIONS (H/W/D - mm)

0…10 V or 4…20mA 0…10 V or 4…20 mA 22.5 / 80 / 80 24 V DC Non Isolated RMCN22BD

0…10 V / 0…20 mA / 4…20 mA

22.5 / 80 / 80 24 V DC Non Isolated RMCL55BD

0…50 V / 0…300 V /0…500 V

0…10 V / 0…20 mA /4…20 mA Switchable

22.5 / 80 / 80 24 V DC Non Isolated RMCV60BD

0…1.5 A / 0…5 A /0…15 A

0…10 V or 0…20 mAor 4…20 mA

45 / 80 / 80 24 V DC Non Isolated RMCA61BD

0…10 V / -10…+10 V /0…20 mA / 4…20 mA Switchable

11

RMT Converters for J & K type thermocouple

■ Converts the voltage signal from J & K type thermocouple tostandard signals. These converters have cold junctioncompensation to allow detection of errors induced byconnection to the device itself. The converters have a presettemperature range for the inputs depending on the modeland a switchable output of 0 - 10 V, 0 - 20 mA and 4 - 20 mA.

RMC voltage/current converters

■ Allows adaptation of electrical values (voltage/current). Fourproducts are available: a cost effective converter will convert0...10 V signal to a 4...20 mA signal or vice-versa; a universalvoltage/current converter converts the most common signals;and two universal voltage/current converters for theconversion of AC as well as DC power signals.

19..30VDC

Type K

OPG

V0

A2

0VDC

A1IP1 (+)

IP2 (-)

A119..30VDC

4..20mA

IPGOPG

V0

I1

A2

0VDC

19..30VDC

A1

V1

V2

V3

IPG

OPG

V0

A2

0VDC

19..30VDC

A1

I1

I01I02

V0

A2

0VDC

I3

I2

19..30VDC

A1

V1

VI I1

IPGOPG

V0

A2

0VDC

A119..30VDC

0..10V

IPGOPG

I0V1

A2

0VDC

Page 12: Zelio Brochure Eng

A unique partner and a worldwide presence

Worldwide availability■ More than 5,000 points of sale in 130 countries.■ You can be sure to find a range of products that meets your needs and

fully complies with the standards in the country in which they are used.

Schneider Electric’s regional focus■ 200 dedicated sales engineers operate from 22 regional sales centres

and 13 technical service centres across Canada.■ Our sales engineers are skilled at assessing individual requirements.

Combined with the expert support of our product specialists, they willdevelop the most effective and economical solution for you, takingrelevant regulations and standards into account.

T9050BR0501EP R0

Schneider Electric

Simply Smart!

The efficiency of Telemecanique branded solutionsUsed in combination, Telemecanique products provide qualitysolutions, meeting all your automation and control applicationsrequirements.

July 2005

Head Office19 Waterman AvenueToronto, Ontario M4B 1Y2www.schneider-electric.caTel: (416) 752-8020Fax: (416) 752-8944Customer Service: 1-800-565-6699

©20

05 S

chne

ider

Can

ada

Inc.

, A

ll R

ight

s R

eser

ved

Networks & Communication

Software tools

Motion control

Power supplies

Mounting systems

Interfaces & I/O

Operator dialog