7/30/2019 Zaranda Alta Capacidad
1/8
High CapacityScreens
Information
7/30/2019 Zaranda Alta Capacidad
2/8
2
The market has been increasinglydemanding high-capacity machines,leading to the development of large-sizedpieces of equipment that require newtools to be used in design, calculationsand quality control.To meet such requirements, in additionto decades of experience in researchingand manufacturing vibrating screens,Haver & Boecker Latinoamericanacounts on: 3D Design Structural calculation based on Finite
Element Analysis (FEA) Calculation testing through tension
measurement with strain gages; Measurement of vibration modes; Drive by high-performance exciters.
Drive by Exciters:Screens too large or heavy can bestarted-up only by exciters.Special Features: Bearings with a useful life of up to
50,000 hours; Easy to maintain by oil lubrication; Range and frequency flexible to adjust;
El mercado cada vez ms exige mqui-nas de alta capacidad, lo que resulta enel desarrollo de equipos de gran porte,que demandan la utilizacin de nuevasherramientas de proyecto, de clculoy de control de calidad. Para atendera esos requisitos, Haver & BoeckerLatinoamericana, adems de la expe-riencia en la investigacin y fabricacinde zarandas vibratorias, dispone de: Proyecto en 3D; Clculo estructural por Anlisis de
Elementos Finitos (FEA); Verificacin de clculo por medio
de medicin de tensiones con straingages;
Medicin de las modalidades de
vibracin; Puesta en marcha por medio de
excitadores de alto desempeo.
Puesta en Marcha por Excitadores:La puesta en marcha por excitadoreses la nica posible para tamices muyanchos y pesados.Principales Caractersticas: Permite hasta 50 mil horas de vida
til de los cojinetes; Facilidad de mantenimiento con
lubricacin por aceite; Flexibilidad de ajustes de amplitud y
frecuencia;
High Capacity ScreensZarandas de Alta Capacidad
El Equipo Vibratorio tambin es conocido en otros pases como:Harnero Vibratorio CHILE y Criba Vibratoria MXICO
Large-sized exciter with dynamic momentum up to 100,000 kg/mm
Excitador de gran monta con momento dinmico de hasta 100.000 Kg/mm
Exciters in different sizes
Diferentes tamaos de excitadores
7/30/2019 Zaranda Alta Capacidad
3/8
3
Finite Element Analysis:Structural calculation by means of FEAallows the simulation of the machinesdynamic behavior through an appropria-te model, testing tensions and naturalfrequencies to assure the predictedresults in a technically and economicallyoptimized design.
Anlisis de Elementos Finitos:El clculo estructural utilizando el FEApermite la simulacin, por medio de unmodelo apropiado, del comportamien-to dinmico de la mquina, probandotensiones y frecuencias naturales, paragarantizar la obtencin de los resultadosprevistos, dentro de un proyecto tcnicoy econmicamente optimizado.
High Capacity ScreensZarandas de Alta Capacidad
High Capacity Screen Model RD - 13 X 36
Zaranda de Alta Capacidade RD - 4000 X 10500
Tension analysisAnlisis de tensiones
7/30/2019 Zaranda Alta Capacidad
4/8
4
The picture in this leaflets cover por-traits a supply delivered in 2003. All databelow are from such design.Construction Data: All the components used in this piece
of equipment were made of specialsteel designed for low temperatures(-50 C);
All the structures, such as drivingbox and bridges are submitted to heat
treatment for tension relief; All crossbars and flanges are machi-
ned, as well as surfaces in contact withs and drilled plates;
All the side plate edges are machinedand double-folded (in U shape);
The frame is fixed by huckbolts, ex-cept for parts subject to wearing waste;
Helicoidal springs are made of specialsteel;
Special corrosion-resistant painting; All parts in contact with the material
are rubber-protected.
La ilustracin de la portada de ese serefiere a un suministro hecho en 2003.Los datos abajo son sobre ese proyecto.Datos de Construccin: Todos los componentes utilizados en
ese equipo fueron hechos con acerosespeciales para bajas temperaturas(-50 C);
Todas las estructuras, tales como lacaja y los puentes de los dispositivosde puesta en marcha, son sometidosa tratamiento trmico para disminuirtensiones;
Todos los listones son grabados en los
rebordes y en las superficies que estnen contacto con los excitadores y lasplacas perforadas;
Todos los bordes de la chapa lateralson grabados y plegados doblemente(en la forma de U);
La parte estructural se fija con rema-ches tipo huckbolt, excepto las partesque sufren desgaste;
Muelles helicoidales hechos en aceroespecial;
Pintura especial resistente a la corro-sin;
Todas las partes en contacto con elmaterial son protegidas con goma.
Assembly phase on field
Fase de montaje en el campo
Installation example
Ejemplo de instalacin
Design and ConstructionProyecto y Construccin
7/30/2019 Zaranda Alta Capacidad
5/8
5
Design Data: Width: 4.045 mm; Total Length: 10.500 mm (2 modules with 5.250 mm each); Total screening area: 42,47 m2; Machine rotation: 600 to 800 rpm with VFD; Vibration Range: 5,5 to 8 mm (11 to 16 mm);
Datos del Proyecto: Ancho: 4.045 mm; Longitud total: 10.500 mm (2 mdulos de 5.250 mm); rea total de zarandeo: 42,47 m2; Rotacin de la mquina: 600 a 800 rpm con VFD
Amplitud de vibracin: 5,5 a 8 mm (11 a 16 mm);
Acceleration: 4,5 g; Possible Inclination Angles: 14/14 12/14 12/16 12/17; Driving by: direct motor / exciters with cardan axis; Total power installed: 264 Kw (132 Kw / module); Screen total weight: 115.000 Kg.
Aceleracin: 4,5 g; Inclinacin posible: 14/14 12/14 12/16 12/17; Puesta en marcha por: motor directo / excitadores por eje cardan; Potencia total instalada: 264 Kw (132 Kw /mdulo)
Peso total de la zaranda: 115.000 Kg.
7/30/2019 Zaranda Alta Capacidad
6/8
6
Construction DetailsDetalles de Construccin
Special screens: highly corrosion-resistant and wide opened drilled plates coated with tungsten carbide
Telas especiales: chapas perforadas recubiertas con carbeto de tungstenio con gran resistencia y alto porcentaje del rea abierta
Double folding in all edges of the side plates
Pliegues dobles en todos los rebordes laterales
Structures reinforced with special brackets able to support largeimpact and volumes
Construccin reforzada con listones especiales preparados paragrandes impactos y grandes capacidades
7/30/2019 Zaranda Alta Capacidad
7/8
7
Immediately after the screen is assem-bled and while still in the manufacturingpremises, several tests are conducted: A modal analysis is performed
with accelerometers to test criticalfrequencies;
In critical points indicated by FEAtension measurements are carried outto check if the tensions are below theacceptable level;
Final adjustments.
Vibration AnalysisHBL developed a computer vibration
analysis tool to find any dynamic irregu-larities in a vibrating screen.This vibration system is characterizedby up to 8 channels of accelerometersthat allow a total analysis of the screendynamic performance. This informationmakes possible to view in the monitorthe orbit points, peak to peak, medianacceleration, displacements, frequency(RPM) and FFT analysis.The results of this evaluation arepresented in easy-to-understand report,which not only introduces the infor-mation analysis but also recommendsnew adjustments to improve equipmentperformance.
An en la planta, justo despus del mon-taje de la zaranda, se realizan diferentestestes: Con acelermetro se realiza un anli-
sis modal, para verificar frecuenciascrticas;
En los puntos crticos indicados por elFEA, se hacen mediciones de tensinpara comprobar que las tensionesestn por debajo del nivel admisible;
Ajuste finales
Anlisis de VibracinHBL desarroll una herramienta deanlisis de vibracin informatizada paradeterminar cualquiera irregularidad en
la condicin dinmica de una zarandavibratoria.Ese sistema de vibracin se caracterizapor hasta ocho canales de acelerme-tros, lo que permite un anlisis total deldesempeo dinmico de la zaranda. Esainformacin permite que se visualice enla pantalla de los puntos de rbita, picoa pico, aceleracin mediana, despla-zamientos, frecuencia (RPM) y anlisisFFT.Los resultados de esa evaluacin sonpresentados en un informe fcil decomprender. Ese informe, adems depresentar el anlisis de las informacio-nes, tambin hace recomendaciones de
nuevos ajustes que mejoren el desem-peo del equipo.
Tension analysis in a test at the manufacturing premises /
20
20
-20
15
-15
10
10
Tension(Mpa)
Time (s)DB 15 Shearing Int side
40 807030 60 9050
-10
5
-5
0
0
Tension reading Results in a thorough cycle: start operation stopLectura de tensin Resultado de un ciclo completo: puesta en marcha funcionamiento parada
Anlisis de tensiones durante teste en la planta
Equipment for
vibration analysis
Equipo para anlisisde vibracin
TestingTestes
7/30/2019 Zaranda Alta Capacidad
8/8
Rodovia Campinas / Monte Mor, Km 20
CEP 13190-000 Monte Mor - SP Brasil
phone: +55 19 3879-9100 fax: +55 19 3879-1410
www.HaverBrasil.com.br
Innovation and Quality for the XXI Century
HBL006E/S-Revised/Revisin06/05
Themachinesandplantsshowninth
isleafletaswellasthestatedtechnicalpara,e
tersareexam
plesofcustomer-specifictechnicalsolutions.Thereforthey
aresubjectto
modifications.Losequiposylasplant
.
Poresaraznsereservaelderechodemodificacionessinavisoprevio.