Top Banner
YSI Aquaculture Monitoring & Control Technologies
26

YSI Advancements in Monitoring & Control Technology Webinar 1213

May 22, 2015

Download

Technology

YSI

Webinar covering product advancements that improve system performance, productivity and efficiency with M&C water quality technology.

Topics include:
• optical based dissolved oxygen
• connectivity/networking options
• automated feeding with YSI Feed Smart
• data management with AquaManager and the AquaViewer App
• alarming options

Applications for M&C systems include tank-based/RAS commercial aquaculture, aquaculture research, live haul, public aquariums, algae culture and anyone interested in aquaculture monitoring and control technology to improve performance, productivity and efficiency.
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: YSI Advancements in Monitoring & Control Technology Webinar 1213

YSI Aquaculture Monitoring & Control

Technologies

Page 2: YSI Advancements in Monitoring & Control Technology Webinar 1213

Outline of Topics

Product Line Overview Sensor Options Dissolved Oxygen Technology Redundancy, System Security and

Flexibility Integration with other Devices Feed Smart Alarming Communication and Remote Data Options AquaManager Desktop Software AquaViewer App

© 2013 YSI Incorporated

Page 3: YSI Advancements in Monitoring & Control Technology Webinar 1213

Models 5200A, 5400 and 5500D (M&C)

Multiparameter; DO, pH, Cond, Salinity, ORP (Redox), Temp. 5200A-AC or DC

Multichannel (4) DO 5400-AC or DC

ysi.com/5200A ysi.com/5400

ysi.com/5500D

Multichannel (1 to 4) optical DO 5500D-01-AC or DC 5500D-02-AC or DC 5500D-04-AC or DC

© 2013 YSI Incorporated

Page 4: YSI Advancements in Monitoring & Control Technology Webinar 1213

Sensor Options Standard Multiparameter; dissolved oxygen,

conductivity, pH, ORP (Redox) and temperature

Dissolved Oxygen; electrochemical (galvanic or polarographic) and optical dissolved oxygen sensors

Auxiliary Any sensor with digital or an analog output; 4-

20ma, 0-1 VDC, 0-5 VDC • Flow • Level • CO2 • Ozone • UV Transmittance

© 2013 YSI Incorporated

Multiparameter

Optical Dissolved Oxygen

Galvanic Dissolved Oxygen

Page 5: YSI Advancements in Monitoring & Control Technology Webinar 1213

ProODO® Probe

Temperature sensor Sensor Cap

with ≈ 12 to18 month life

© 2013 YSI Incorporated

Page 6: YSI Advancements in Monitoring & Control Technology Webinar 1213

Measuring Dissolved Oxygen Optically

Oxygen is constantly moving through the Diffusion Layer, affecting the luminescence of the sensing layer.

The amount of oxygen passing through the sensing layer is inversely proportional to the lifetime of the luminescence in the sensing layer.

The lifetime of the luminescence is measured by the sensor and compared against the reference.

© 2013 YSI Incorporated

Page 7: YSI Advancements in Monitoring & Control Technology Webinar 1213

Flow Dependence

Flow Stopped

© 2013 YSI Incorporated

Page 8: YSI Advancements in Monitoring & Control Technology Webinar 1213

Flow Dependence Continued

Flow Stopped

© 2013 YSI Incorporated

Page 9: YSI Advancements in Monitoring & Control Technology Webinar 1213

Optical Dissolved Oxygen Advantages Optical Dissolved Oxygen Technology can save you $$$

Higher accuracy • No stirring/flow required to achieve accurate

measurements • Maintain healthy levels of O2 while saving on aeration

and/or oxygen costs

Low maintenance • No electrodes to clean • No regular membrane changes • Extremely stable long term so no need for frequent

calibrations

Not affected by Hydrogen Sulfide or other gasses

© 2013 YSI Incorporated

Page 10: YSI Advancements in Monitoring & Control Technology Webinar 1213

Redundancy, System Security and Flexibility Measurement and control functions managed at the

instrument level. No risk of complete network/system failure.

Password protected functions Tank side display for easy use and calibration AC units automatically switch to DC backup power when

AC mains power goes down. An Email or SMS message will be sent.

Alarms on loss of networked slave devices Fully user configurable and scalable – fits any operation

without custom programming and can be easily modified by the user as their needs change.

© 2013 YSI Incorporated

Page 11: YSI Advancements in Monitoring & Control Technology Webinar 1213

YSI M&C and PLC Systems

YSI M&C products can be easily

integrated into systems using PLCs via RS-232 or Ethernet communication.

A hybrid approach - the YSI M&C product performs some process control and some process control is performed by the PLC.

Allows the integrator or customer to develop their own custom software solution if desired.

© 2013 YSI Incorporated

Page 12: YSI Advancements in Monitoring & Control Technology Webinar 1213

Feed Smart™ Conditional Feed Timer

Manages feed delivery: Simple, one-step calibration

process Up to 100 feedings per day Decrease feed amount by

user defined % based on DO and Temperature values (also, pH values on the 5200A)

Increases feed amount on a daily basis by user defined FCR

© 2013 YSI Incorporated

bit.ly/FeedSmart

Page 13: YSI Advancements in Monitoring & Control Technology Webinar 1213

Feed Smart™ Conditional Feed Timer

Day 1 Day 2 Day 3 Day 4 Day 5 Day 6 Day 7

Feed % of Biomass (user entered value) 4.00% 4.00% 4.00% 4.00% 4.00% 4.00% 4.00%

Biomass (enter beginning value only) 2500.0 2566.7 2635.1 2705.4 2777.5 2851.6 2927.6

Daily Feed Amount (system calculated) 100.0 102.7 105.4 108.2 111.1 114.1 117.1

Cumulative Feed Amount (system calculated) 100.0 202.7 308.1 416.3 527.4 641.5 758.6

FCR Factor x.x to 1.0 (user entered value) 1.5

Make FCR a decimal (system calculated) 0.67

Increase in Biomass (system calculated) 66.7 68.4 70.3 72.1 74.1 76.0 78.1

Cumulative Biomass Increase (system calculated) 66.7 135.1 205.4 277.5 351.6 427.6 505.7

Calculated New Biomass 2566.7 2635.1 2705.4 2777.5 2851.6 2927.6 3005.7

Example Calculation Chart

© 2013 YSI Incorporated

bit.ly/FeedSmart

Page 14: YSI Advancements in Monitoring & Control Technology Webinar 1213

Alarms

General Alarm Ability to configure a single relay to control light or

siren based on any alarm condition Alarm Conditions Parameter out of range Power outage; loss of AC

power and low DC voltage Loss of slave Loss of ODO communication Alarm Hold Off When enabled, acts as a filter

for false alarms © 2013 YSI Incorporated

Page 15: YSI Advancements in Monitoring & Control Technology Webinar 1213

E-mail and SMS Alarming [email protected] Date: Wed 04 Dec 2013 18:10:46 Subject: AutoPoller Alarm Message YSI5200A Alarm Tilapia Tank #1 DO Low Alarm: 4.50 mg/L

Alarms

© 2013 YSI Incorporated

Page 16: YSI Advancements in Monitoring & Control Technology Webinar 1213

Networking and Communication Options

© 2013 YSI Incorporated

Page 17: YSI Advancements in Monitoring & Control Technology Webinar 1213

Networking and Communication Options

© 2013 YSI Incorporated

Page 18: YSI Advancements in Monitoring & Control Technology Webinar 1213

Networking and Communication Options

© 2013 YSI Incorporated

Page 19: YSI Advancements in Monitoring & Control Technology Webinar 1213

Networking and Communication Options

© 2013 YSI Incorporated

Page 20: YSI Advancements in Monitoring & Control Technology Webinar 1213

AquaManager Software

Data Management Graphing Data export Event logging Manual data entry

System Management Explorer based network setup and support E-mail and SMS setup Set-point and control management

© 2013 YSI Incorporated

Page 21: YSI Advancements in Monitoring & Control Technology Webinar 1213

Mapping Screen

• Gives a quick visual of the entire operation

• Images include animations

• Easy for user to set up

© 2013 YSI Incorporated

Page 22: YSI Advancements in Monitoring & Control Technology Webinar 1213

Event Logging

© 2013 YSI Incorporated

Page 23: YSI Advancements in Monitoring & Control Technology Webinar 1213

Event Logging

© 2013 YSI Incorporated

Page 24: YSI Advancements in Monitoring & Control Technology Webinar 1213

AquaViewer Apple Device App

Set up screen #1 Set up screen #2 Network Viewer screen: • Normal • Control in yellow • Alarms in red

Instrument Viewer screen: • Normal in green • Control in yellow • Alarms in red

• iPhone • iPad • iPod Touch (generation #3 or higher)

© 2013 YSI Incorporated

Page 25: YSI Advancements in Monitoring & Control Technology Webinar 1213

© 2013 YSI Incorporated

Wrap Up

So, why choose YSI? Proven and trusted

technology Global presence Provide solutions that

make you more productive Professional support

Page 26: YSI Advancements in Monitoring & Control Technology Webinar 1213

Questions? © 2013 YSI Incorporated