Top Banner
YOUR PARTNER IN OIL&GAS AND POWER GENERATION A COMPANY OF Since 1988 we find solutions
24

YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Mar 12, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

YOUR PARTNER IN OIL&GAS

AND POWER GENERATION

A COMPANY OF Since 1988

we find solutions

Page 2: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Table of contents

• Location

• Site

• Workshop Layout

• Offices

• Workshop Overview

• Production Means

• Testing Equipments

• Products

• Special Processes

• Qualification & Certification

f l e n c o . c o m 1

Page 3: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

• FLENCO d.o.o.Rogozniška cesta, 14 - 2250 PTUJ

SLOVENIJA

Tel.: +386 2 749 27 30

Next to:

• Airport:

Graz (Austria)

Zagreb (Croatia)

Ljubljana (Slovenia)

• By car:

Ljubljana: 1hr 20min

Maribor: 30min

Zagreb: 1hr

Graz: 1hr

Location

f l e n c o . c o m 2

ITALY

AUSTRIA

Maribor

Ljubljana

PTUJ

CROATIA

Page 4: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Flenco d.o.o. – Ptuj (Slovenia)

Site

f l e n c o . c o m 3

• Total area: 22.000 sqm

• Total covered area: 8.800 sqm

• Offices (two floors): 2.300 sqm

• Loading / Unloading area: 200 sqm

• Assembly / Test area: 700 sqm

• Pre-assembly area: 1.000 sqm

• Production / Welding area: 2.000 sqm

• Painting / Sandblasting area: 270 sqm

• Warehouse: 850 sqm

• Machining area: 400 sqm

• Available labour hours/year: 220.000

• Subcontracted NDT

• Cranes:

Assembly: 2x25 tons + 1x15

Steel fabrication: 2x10 tons

Light Steel fabrication: 2x5 tons

Stainless Steel fabrication: 1x10 tons

Pre-assembly: 2x20 tons

Storehouse: 2x5 tons

Page 5: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Workshop layout

Total area: 8.000 sqm

f l e n c o . c o m 4

150mt

145mt

1. Final Assembly

2. Pre Assembly

3. Filler Mat & Electr. Comp. Warehouse

4. Pre-assembly small units

5. Inox Fabrication

6. Painting Chamber

7. Shotblasting Chamber

8. Painting Chamber

9. Fabrication Carbon Steel

10.Welding Boxes

• Cranes

• Electrical Boards

• Machining Tools

• Oil distribution system

• Different test benches

• X-Ray bunker

• Sandblasting and Painting

Page 6: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Workshop Overview

f l e n c o . c o m 5

Cables warehouse Raw materials warehouse

Painting chamber Shotblasting

Page 7: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Workshop Overview

f l e n c o . c o m 6

Final Assembly & Testing Area

Inox Tank Fabrication 8,5 x 3,0 x 2,2 mt

Page 8: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Workshop Overview

f l e n c o . c o m 7

Carbon Steel Fabrication

Pre-assembly & Testing Area

Page 9: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Workshop Overview

f l e n c o . c o m 8

Bending machine

Lathe machine 8mt long

Page 10: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Production Means

f l e n c o . c o m 9

Lifting Equipments:

• 2 cranes 25T

• 2 cranes 20T

• 1 crane 15T

• 2 cranes 10T

• 4 cranes 5T

• 2 fork lifts 5T

Other Equipments:

• Air compressor 90Kw 8.5 bar

• Air compressor 37Kw 8.5 bar

• 100.000 Liters Oil Tank with filtering system

• Oil distribution system for faster filling Lube Oil module

• Centralized Argon distribution system for GTAW/TIG welding

Page 11: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Production Means

f l e n c o . c o m 10

Field instruments:

Different type of Pressure Gauges

Different type of Flow Meters

Different type of Pressure Transmitters to record pressure transients during functional test.

Electrical power supply:

• N°1 Inverter 500Kw A.C. – 380 Volt

• N°2 Inverter 75Kw A.C. – 380 Volt

• N°3 Inverter 90Kw A.C. – 380 Volt

• N°1 DC Starter 30Kw – 110-220 Volt

• N°1 DC Starter 8Kw – 110-220 Volt

• N°1 DC Starter 160Kw – 110-220 Volt

Page 12: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Production Means

f l e n c o . c o m 11

National Instrument PLC

For high speed recording of fluidodynamicparameters during functional test.

Other instruments:

• Oil Analyzer – NAS / ISO (MP Filtri)

• Pressure Calibrator (Low and High pressure)

• Vibration Meter (Bently Nevada)

• Oscilloscope (Fluke)

• Function generator (Fluke)

• 4 – 20mA Generator (Fluke)

• 4 – 20mA Calibrator (Fluke)

• Multimeter (Fluke)

• Current Clamp (Fluke) etc.

Page 13: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Products – Lube Oil Frame 9

f l e n c o . c o m 12

Page 14: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Products – Aux. Frame 6/Frame 7

f l e n c o . c o m 13

Page 15: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Products – Aux. Frame 5

f l e n c o . c o m 14

Page 16: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Products – Degassing tank

f l e n c o . c o m 15

Page 17: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Products – Seal Oil System

f l e n c o . c o m 16

Page 18: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Products – Lube Oil System

f l e n c o . c o m 17

Page 19: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Products – Lube Oil System

f l e n c o . c o m 18

Page 20: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Products - 6FA LO & GAS Auxiliary Systems

f l e n c o . c o m 19

Page 21: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Products – Gas Particulate Filter

f l e n c o . c o m 20

Page 22: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Special Processes

f l e n c o . c o m 21

Welding

• All welding processes and welders are qualified under EN and ASME IX standards.

• EN ISO 3834-2 e EN 1090-2

• Filler products comply with both EN and AWS standards.

NDT

• NDT personnel qualification: VT: level II according to EN Code

• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI)

• RT, UT: external company with level II qualified personnel according to ASME/EN Code.

• Six Sigma black belt / FROSIO qualified personnel

Page 23: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

Certification & Standards

f l e n c o . c o m 22

Capability on system production according to:

• ASME /AWS

• API

• TRD412

• TRR100

• AD Merkblatt Std

• EN standard (ATEX, Machinery, Low Tension, EMC, PED )

Company Certified according to:

• ISO 9001:2008

• ISO 14001:2004

• OHSAS 18001:2007

• PED

Surface treatment capability according to:

• SSPC

• ISO12944

Page 24: YOUR PARTNER IN OIL&GAS• PT, MT: level II according to ANSI/ASNT Standard CP189 (ASME sec.XI) • RT, UT: external company with level II qualified personnel according to ASME/EN

ITALYAvigliana (TO)

Trino (VC)

Calenzano (FI)

SLOVENIAPtuj

CHINANingbo

Where we are

f l e n c o . c o m

YOUR PARTNER IN OIL&GAS

AND POWER GENERATION

we find solutions

• Avigliana HeadquarterCorso Torino, 4M - 10051 Avigliana (TO) - Italy

Tel. : +39 011 93 30 611 - Fax : +39 011 936 77 17

[email protected]

• Trino WorkshopS.S. 31 Bis Km 31 - 13039 Trino (VC) – Italy

Tel.: +39 0161 804212 - Fax: +39 0161 801523

[email protected]

• Firenze OfficeVia Vittorio Emanuele, 19 – 50041 Calenzano (FI) – Italy

Tel. +39 055.31.95.26 - Fax: +39 055 319 376

[email protected]

• Flenco d.o.o.Rogozniska, 14 - 2250 Ptuj – Slovenija

tel.: +386 2 749 27 30

[email protected]

• Flenco Fluid System Ningbo Co., Ltd.Nisseki Building – 2F - 438 Zhujiang Road – Beilun Area

315800 Ningbo – Zhejiang Province - P.R. China

tel.: +86 574 8683 1903 - fax: +86 574 8689 7939

[email protected]

23