8/9/2019 Xypex - Construction Joint
1/22
STANDARD CONSTRUCTION JOINT DETAILS
SCHEMATIC DRAWINGS
Not subject to hydrostatic pressure
Subject to hydrostatic pressure
Walls & Slabs
Step 1 Joint Waterproofng: Clean joint thoroughly. Between pours, apply Xypex Concentrate slurryto joint surfaces at the rate of 2.0 lb./sq. yd. (1.0 kg/m2).
Step 2 Sealing Strip: Clean pre-formed groove thoroughly. Apply Xypex Concentrate slurry to grooveat the rate of 1.5 lb./sq. yd. (0.8 kg/m2). Fill groove with Xypex Concentrate Dry-Pac and pack
tightly. Pre-formed groove may be offset to either side of joint.
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
1
12
Nominal 2” x 4” (50 mm x 100 mm)
or 2” x 6” (50 mm x 150 mm)
key centered in joint.
Reinforcing continuous
through joint.
Nominal 2” x 4” (50 mm x 100 mm)
or 2” x 6” (50 mm x 150 mm)
key centered in joint.
Reinforcing continuous
through joint.
CONCENTRATE SLURRY COAT CONCENTRATE DRY-PAC
8/9/2019 Xypex - Construction Joint
2/22
STANDARD CONSTRUCTION JOINT DETAILS
SCHEMATIC DRAWINGS
Not subject to hydrostatic pressure
Subject to hydrostatic pressure
1
1
Nominal 2” x 4” (50 mm x 100 mm)or 2” x 6” (50 mm x 150 mm)
key centered in joint.
Reinforcing continuous
through joint.
Nominal 2” x 4” (50 mm x 100 mm)
or 2” x 6” (50 mm x 150 mm)
key centered in joint.
Reinforcing continuous
through joint.
CONCENTRATE SLURRY COAT CONCENTRATE DRY-PAC
2
Walls / Slab Interface
Step 1 Joint Waterproofng: Clean joint thoroughly. Between pours, apply Xypex Concentrate slurryto joint surfaces at the rate of 2.0 lb./sq. yd. (1.0 kg/m2).
Step 2 Sealing Strip: Clean pre-formed groove thoroughly. Apply Xypex Concentrate slurry to grooveat the rate of 1.5 lb./sq. yd. (0.8 kg/m2). Fill groove with Xypex Concentrate Dry-Pac and pack
tightly. Pre-formed groove may be offset to either side of joint.
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
8/9/2019 Xypex - Construction Joint
3/22
CONCRETE WALL AND SLAB – BELOW GRADE
SCHEMATIC DRAWINGS
1
3
CONCENTRATE SLURRY COAT CONCENTRATE DRY-PAC
2
3
1
Step 1 Between pours, apply Xypex Concentrate slurry to joint surfaces at the rate of 2.0 lb./sq. yd.(1.0 kg/m2).
Step 2 In sealing strip, apply one slurry coat of Xypex Concentrate at the rate of 1.5 lb./sq. yd.(0.8 kg/m2) then ll slot to surface with Xypex Concentrate in Dry-Pac form.
Step 3 Apply one coat of Xypex Concentrate to wall and slab surfaces as indicated at the rate of1.5 lb./sq. yd. (0.8 kg/m2).
Where poor drainage conditions exist or high hydrostatic pressures are anticipated, also apply
a coat of Xypex Modied to wall and slab surfaces at the rate of 1.25 - 1.5 lb./sq. yd. (0.65 -
0.8 kg/m2).
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
2
8/9/2019 Xypex - Construction Joint
4/22
FOUNDATION WALL – INSIDE APPLICATION
SCHEMATIC DRAWINGS
2
3
CONCENTRATE SLURRY COAT CONCENTRATE DRY-PAC
2
1
1
Step 1 Between pours, apply Xypex Concentrate slurry to joint surfaces at the rate of 2.0 lb./sq. yd.(1.0 kg/m2).
Step 2 In sealing strip, apply one slurry coat of Xypex Concentrate at the rate of 1.5 lb./sq. yd.(0.8 kg/m2), then ll slot to surface with Xypex Concentrate in Dry-Pac form.
Step 3 Apply one slurry coat of Xypex Concentrate to wall and slab surfaces as indicated at the rateof 1.5 lb./sq. yd. (0.8 kg/m2).
Where poor drainage conditions exist or high hydrostatic pressures are anticipated, also apply
a coat of Xypex Modied to wall and slab surfaces at the rate of 1.25 - 1.5 lb./sq. yd. (0.65 -
0.8 kg/m2).
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
8/9/2019 Xypex - Construction Joint
5/22
RETAINING WALL
SCHEMATIC DRAWINGS
1
CONCENTRATE SLURRY COAT CONCENTRATE DRY-PAC
2
3
1
Step 1 Between pours, apply Xypex Concentrate slurry to joint surfaces at the rate of 2.0 lb./sq. yd.(1.0 kg/m2).
Step 2 In sealing strip, apply one slurry coat of Xypex Concentrate at the rate of 1.5 lb./sq. yd.(0.8 kg/m2), then ll slot to surface with Xypex Concentrate in Dry-Pac form.
Step 3 Apply one coat of Xypex Concentrate to wall face and over sealing strip at the rate of1.5 lb./sq. yd. (0.8 kg/m2).
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
8/9/2019 Xypex - Construction Joint
6/22
Step 1 Prior to placement of the concrete wall and slab, apply one slurry coat of Xypex Concentrateto joint surfaces at the rate of 2 lb./sq. yd. (1 kg/m2).
Step 2 In sealing strip, apply one slurry coat of Xypex Concentrate at the rate of 1.5 lb/sq. yd.(0.8 kg/m2), then ll slot to surface with Xypex Concentrate in Dry-Pac form.
Step 3 To exterior wall surface and footing apply one coat of Xypex Concentrate at the rate of
2.0 lb./sq. yd. (1.0 kg/m2). After the Concentrate has set but while it is still “green”, apply acoat of Xypex Megamix I at the rate of 11.25 lb./sq. yd. (5.5 kg/m2).
Note: Because of the variances in the quality of concrete block (e.g. cement, content, porosity,
etc.), please consult your Xypex technical representative.
Schematic diagram shows Xypex coatings application only and does not depict the standard
requirements for waterstops, expansion joint sealants, or pointing repairs that may be required.
Refer to Standard Specications for further information.
CONCRETE BLOCK WALL – BELOW GRADE – EXTERIOR APPLICATION
SCHEMATIC DRAWINGS
1
CONCENTRATE SLURRY COAT MEGAMIX ICONCENTRATE DRY-PAC
3
2
8/9/2019 Xypex - Construction Joint
7/22
1
2
CONCRETE BLOCK WALL – BELOW GRADE – INSIDE APPLICATION
SCHEMATIC DRAWINGS
CONCENTRATE SLURRY COAT MEGAMIX ICONCENTRATE DRY-PAC
Step 1 Prior to placement of the concrete wall and slab, apply one slurry coat of Xypex Concentrateto joint surfaces at the rate of 2 lb./sq. yd. (1 kg/m2).
Step 2 In sealing strip, apply one slurry coat of Xypex Concentrate at the rate of 1.5 lb/sq. yd.(0.8 kg/m2), then ll slot to surface with Xypex Concentrate in Dry-Pac form.
Step 3 To inside wall surface apply one coat of Xypex Concentrate at the rate of 2.0 lb./sq. yd.
(1.0 kg/m2). After the Concentrate has set but while it is still “green”, apply a coat of XypexMegamix I at the rate of 11.25 lb./sq. yd. (5.5 kg/m2).
Note: Because of the variances in the quality of concrete block (e.g. cement, content, porosity,
etc.), please consult your Xypex technical representative.
Schematic diagram shows Xypex coatings application only and does not depict the standard
requirements for waterstops, expansion joint sealants, or pointing repairs that may be required.
Refer to Standard Specications for further information.
3
8/9/2019 Xypex - Construction Joint
8/22
CONCRETE BLOCK WALL – ABOVE GRADE – EXTERIOR APPLICATION
SCHEMATIC DRAWINGS
1
CONCENTRATE SLURRY COAT
Step 1 Apply one slurry coat of Xypex Concentrate at the rate of 1.5 lb./sq. yd. (0.8 kg/m2). Coatingshould extend to ground level. Where poor quality block is encountered, a second coat of
Xypex Concentrate should be applied at the rate of 1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2).
Wall sections should be dened before application and each of these sections should be
completed during the same day to obtain maximum uniformity in appearance.
Because of the variances in the quality of concrete block (e.g. cement content, porosity, etc.),
please consult your Xypex technical representative.
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series), Xypex Additive (Admix C-Series) or Xypex
Megamix I, where applicable. Refer to Standard Specications for more information.
8/9/2019 Xypex - Construction Joint
9/22
PARKING DECK
SCHEMATIC DRAWINGS
1
CONCENTRATE SLURRY COAT MODIFIED SLURRY COATCONCENTRATE DRY-PAC
1
3 2
Step 1 Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of 2.0 lb./sq. yd.(1.0 kg/m2).
Step 2 In sealing strip, apply one coat of Xypex Concentrate at the rate of 1.5 lb./sq. yd. (0.8 kg/m2),then ll slot to surface with Xypex Concentrate in Dry-Pac form.
Step 3 To slab, apply one coat of Xypex Concentrate at the rate of 1.25 - 1.5 lb./sq. yd.(0.65 - 0.8 kg/m2). After the Concentrate has set but while it is still “green”, apply a coat of
Xypex Modied at the rate of 1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2).
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
8/9/2019 Xypex - Construction Joint
10/220
ROOF / PLAZA DECK
SCHEMATIC DRAWINGS
1 1
2 2
CONCENTRATE SLURRY COAT MODIFIED SLURRY COATCONCENTRATE DRY-PAC
3
Step 1 Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of 2.0 lb./sq. yd.(1.0 kg/m2).
Step 2 In sealing strip, apply one coat of Xypex Concentrate at the rate of 1.5 lb./sq. yd. (0.8 kg/m2),then ll slot to surface with Xypex Concentrate in Dry-Pac form.
Step 3 To slab and adjacent curb wall apply one coat of Xypex Concentrate at the rate of1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2). After the Concentrate has set but while it is still “green”,
apply a coat of Xypex Modied at the rate of 1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2).
Use appropriate material for protection against sudden thermal changes.
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
8/9/2019 Xypex - Construction Joint
11/22
ELEVATOR PIT / SUMP PIT
SCHEMATIC DRAWINGS
1 1
2
CONCENTRATE SLURRY COAT MODIFIED SLURRY COATCONCENTRATE DRY-PAC
Step 1 In sealing strip, apply one coat of Xypex Concentrate at the rate of 1.5 lb./sq. yd. (0.8 kg/m2),then ll slot to surface with Xypex Concentrate in Dry-Pac form.
Step 2 Apply one slurry coat of Xypex Concentrate to walls and oor slab at a rate of1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2). After the Concentrate has set but while it is still “green”,
apply a coat of Xypex Modied at the rate of 1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2).
For hydraulic elevators, please contact your Xypex representative for detail drawings.
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
8/9/2019 Xypex - Construction Joint
12/222
PLANTER
SCHEMATIC DRAWINGS
3
1
CONCENTRATE SLURRY COAT MODIFIED SLURRY COAT
2
Step 1 Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of 2.0 lb./sq. yd.(1.0 kg/m2).
Step 2 Apply one slurry coat of Xypex Concentrate at the rate of 1.5 lb./sq. yd. (0.8 kg/m2) to all interiorwall and oor surfaces.
Step 3 After slurry coat has set but while it is still “green”, apply a cove strip of Xypex Modied mortarover interior slab/wall construction joint.
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
8/9/2019 Xypex - Construction Joint
13/22
TUNNEL
SCHEMATIC DRAWINGS
2
1
3
CONCENTRATE SLURRY COAT MODIFIED SLURRY COATCONCENTRATE DRY-PAC
Step 1 Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of 2.0 lb./sq. yd.(1.0 kg/m2).
Step 2 In sealing strip, apply one coat of Xypex Concentrate at the rate of 1.5 lb./sq. yd. (0.8 kg/m2),then ll slot to surface with Xypex Concentrate in Dry-Pac form.
Step 3 To all ceiling, wall, and oor surfaces, apply one slurry coat of Xypex Concentrate at the rateof 1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2). After the Concentrate has set but while it is still
“green”, apply a coat of Xypex Modied at the rate of 1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2).
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
1
8/9/2019 Xypex - Construction Joint
14/224
SWIMMING POOL
SCHEMATIC DRAWINGS
3
CONCENTRATE SLURRY COAT MODIFIED SLURRY COATCONCENTRATE DRY-PAC
Step 1 Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of 2.0 lb./sq. yd.(1.0 kg/m2).
Step 2 In sealing strip, apply one slurry coat of Xypex Concentrate at the rate of 1.5 lb./sq. yd.(0.8 kg/m2), then ll slot to surface with Xypex Concentrate in Dry-Pac form.
Step 3 To pool deck and all interior wall and oor surfaces, apply one slurry coat of Xypex Concentrateat a rate of 1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2). After the Concentrate has set but while it is
still “green”, apply a coat of Xypex Modied at a rate of 1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2).
In new construction, Xypex Concentrate DS-1 or Xypex Admix is recommended for pool deck
and oor surfaces. Please refer to product data sheets.
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
2
1
8/9/2019 Xypex - Construction Joint
15/22
SEWAGE PLANT CLARIFIER TANK
SCHEMATIC DRAWINGS
2
2 2
1
3
CONCENTRATE SLURRY COAT MODIFIED SLURRY COATCONCENTRATE DRY-PAC
Step 1 Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of 2.0 lb./sq. yd.(1.0 kg/m2).
Step 2 In sealing strip, apply one coat of Xypex Concentrate at the rate of 1.5 lb./sq. yd. (0.8 kg/m2),then ll slot to surface with Xypex Concentrate in Dry-Pac form.
Step 3 To all ceiling, wall, and oor surfaces, apply one slurry coat of Xypex Concentrate at the rateof 1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2). After the Concentrate has set, but while it is still
“green”, apply a coat of Xypex Modied at the rate of 1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2).
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
8/9/2019 Xypex - Construction Joint
16/226
SEWAGE PLANT DIGESTER TANK
SCHEMATIC DRAWINGS
2
3
1
CONCENTRATE SLURRY COAT MODIFIED SLURRY COATCONCENTRATE DRY-PAC
Step 1 Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of 2.0 lb./sq. yd.(1.0 kg/m2).
Step 2 In sealing strip, apply one coat of Xypex Concentrate at the rate of 1.5 lb./sq. yd. (0.8 kg/m2),then ll slot to surface with Xypex Concentrate in Dry-Pac form.
Step 3 To all wall and slab surfaces, apply one slurry coat of Xypex Concentrate at the rate of1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2). After the Concentrate has set, but while it is still
“green”, apply a coat of Xypex Modied at the rate of 1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2).
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
8/9/2019 Xypex - Construction Joint
17/22
RESERVOIR / WET WELL
SCHEMATIC DRAWINGS
3
3
2
2
CONCENTRATE SLURRY COAT MODIFIED SLURRY COATCONCENTRATE DRY-PAC
1
1
Step 1 Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of 2.0 lb./sq. yd.(1.0 kg/m2).
Step 2 In sealing strip, apply one coat of Xypex Concentrate at the rate of 1.5 lb./sq. yd. (0.8 kg/m2),then ll slot to surface with Xypex Concentrate in Dry-Pac form.
Step 3 To interior walls, slab and exterior of roof area, apply one slurry coat of Xypex Concentrateat the rate of 1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2). After the Concentrate has set, but
while it is still “green”, apply a coat of Xypex Modied at the rate of 1.25 - 1.5 lb./sq. yd.
(0.65 - 0.8 kg/m2).
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
8/9/2019 Xypex - Construction Joint
18/228
UNDERGROUND VAULT / DRY WELL
SCHEMATIC DRAWINGS
3
2
2
3
CONCENTRATE SLURRY COAT MODIFIED SLURRY COATCONCENTRATE DRY-PAC
1
Step 1 Between pours, apply Xypex Concentrate slurry to all joint surfaces at the rate of 2.0 lb./sq. yd.(1.0 kg/m2).
Step 2 In sealing strip, apply one coat of Xypex Concentrate at the rate of 1.5 lb./sq. yd. (0.8 kg/m2),then ll slot to surface with Xypex Concentrate in Dry-Pac form.
Step 3 To interior oor areas and exterior walls and roof, apply one slurry coat of Xypex Concentrateat the rate of 1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2). After the Concentrate has set, but
while it is still “green”, apply a coat of Xypex Modied at the rate of 1.25 - 1.5 lb./sq. yd.
(0.65 - 0.8 kg/m2).
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
8/9/2019 Xypex - Construction Joint
19/22
PRECAST CONCRETE MANHOLE
SCHEMATIC DRAWINGS
2
4
3
CONCENTRATE SLURRY COAT CONCENTRATE DRY-PAC
1
2
4
PATCH’N PLUG
Step 1 Place block in joints to allow 0.5 - 0.75 in. (13 - 19 mm) gap between precast sections.Fill exterior gap with Xypex Patch’n Plug grout.
Step 2 Apply one slurry coat of Xypex Concentrate to the interior gap at the rate of 1.5 lb./sq. yd.(0.8 kg/m2), then ll gap to surface with Xypex Concentrate in Dry-Pac form.
Step 3 Apply one slurry coat of Xypex Concentrate to interior of bottom ring, oor and exterior wallsat the rate of 1.25 - 1.5 lb./sq. yd. (0.65 - 0.8 kg/m2).
Step 4 After placement of concrete trough, apply one slurry coat of Xypex Concentrate at the rateof 1.5 lb./sq. yd. (0.8 kg/m2) to its surface.
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
8/9/2019 Xypex - Construction Joint
20/220
STANDARD METAL PIPE DETAIL
SCHEMATIC DRAWINGS
CONCENTRATE SLURRY COAT CONCENTRATE DRY-PAC
2
1
Step 1 Apply Xypex Concentrate slurry to the groove at the rate of 1.5 lb./sq. yd. (0.8 kg/m2).
Step 2 Fill groove to surface with Xypex Concentrate in Dry-Pac form and pack tightly. Brush Dry-Pacliberally with water and apply a Xypex Concentrate slurry over the Dry-Pac at the rate of
1.5 lb./sq. yd. (0.8 kg/m2).
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
8/9/2019 Xypex - Construction Joint
21/22
FERRO-CEMENT BOAT / CAISSON / FLOATING DOCK
SCHEMATIC DRAWINGS
CONCENTRATE SLURRY COAT
2
1
MODIFIED SLURRY COAT
Step 1 Apply one slurry coat of Xypex Concentrate to hull exterior, gunwhales, and all exterior decksat the rate of 1.5 lb./sq. yd. (0.8 kg/m2).
Step 2 Apply one coat of Xypex Modied to interior surface of hull at the rate of 1.5 lb./sq. yd.(0.8 kg/m2).
In the case of sealed, hollow-core caissons, step 2 is eliminated and the Concentrate slurry coat
in step 1 should extend over entire exterior of unit.
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where
applicable. Refer to Standard Specications for more information.
8/9/2019 Xypex - Construction Joint
22/22
BRIDGE
SCHEMATIC DRAWINGS
CONCENTRATE SLURRY COAT
1
MODIFIED SLURRY COAT
4
3
2
Step 1 Apply one slurry coat of Xypex Concentrate to structural slab at the rate of 1.5 lb./sq. yd.(0.8 kg/m2).
Step 2 Apply one slurry coat of Xypex Concentrate to joint surface between parapet wall and bridgedeck at the rate of 2.0 lb./sq. yd. (1.0 kg/m2). Xypex must be applied no more than 24 hours
prior to concrete placement.
Step 3 Apply a cove strip of Xypex Modied mortar over slab/wall construction joint so that the coveextends 1 in. (25 mm) up the wall and 1 in. (25 mm) out on to the deck surface.
Step 4 Apply one slurry coat of Xypex Concentrate to wall surfaces at the rate of 1.5 lb./sq. yd.(0.8 kg/m2).
Note 1: Schematic diagram shows Xypex application details only and does not depict standard
requirements for waterstops or expansion joint sealants.
Note 2: Schematic drawing shows Xypex Coating application. Specier may consider the
alternative use of Xypex Dry Shake (DS-Series) or Xypex Additive (Admix C-Series), where