Xpole Industrial Feeder and Branch Circuit Breaker www.moeller.net Xpole Industrial, the logical continuation of the develop- ment of installation products for industrial applications. From protective switches to modular installation devices to surge protection, every- thing matches, and the com- plete range combines all the benefits. Xpole Industrial Product Information Feeder and Branch Circuit Breaker FAZ-NA FAZ-RT (Ring Tonque Connection)
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Xpole Industrial
Feeder and Branch Circuit Breaker
www.moeller.net
Xpole Industrial, the logicalcontinuation of the develop-ment of installation productsfor industrial applications.From protective switches tomodular installation devicesto surge protection, every-thing matches, and the com-plete range combines all thebenefits.
Xpole Industrial
Product Information
Feeder and Branch Circuit BreakerFAZ-NA FAZ-RT (Ring Tonque Connection)
Optimum and Efficient
Protection for Every Application
2
10 kA UL 489, C22.2 No.5
15 kA IEC 60947-2
When it comes to pro-tection and switching,industries in manycountries rely onMoeller products.
Optimum product quality, tested relia-bility and safety stand for best protec-tion of personnel, installations andplant. Approvals in many countriesconfirm Moeller builts its products tocomply with the latest national andinternational Regulations.
Powerful offering for machine andsystem buildersThe Xpole Industrial FAZ-NA, FAZ-RTis available with C and D characteristicin accordance with UL 489, CSA C22.2No.5; UL 1077, CSA C22.2 No.235and IEC 60947-2
Typical Applications
Feeder and Branch CircuitProtection• Convenience receptacle circuits
(internal/external)• Motors
(internal/external)• Load circuits leaving the equipment
(external)• HACR Equipment (Heating, Air Con-
ditioning, Refrigeration)(internal/external)
Supplementary Protection FAZ, FAZ-NA and FAZ-RT• Additional protection for: sensitive
equipment, electronic components(e.g. computers)
• Motor control circuits without transformers
3
Features
• Current limiting
• SWD (switching duty) – suitable for switching fluorescent lightingloads (In ≤ 20 A)
• Fulfill UL 489, CSA C22.2 No. 5 and also IEC 60947-2 Standard
• For use in application for which UL 1077 or CSA C22.2 No.235 arealso allowed
• Shunt trip release and auxiliary switch for subsequent mounting
• Separate Version for Ring Tonque Connection (Type FAZ-….-RT), terminal screws can be removed (on both sides)
• Module width of only 17,7 mm (per pole)
• Contact Position Indicator (red/green)
• Easy installation on DIN rail
• Possibility for sealing the toggle in on- or off-position
FAZ-NA
FAZ-RT
FAZ-RT
Captive screws cannot be lost
4
FAZ complies with the latestnational and internationalStandards
UL
Standards – Feeder and Branch Circuit Protection
• UL 489
Standard for molded case circuit breakers (MCCB) for feeder andbranch circuit protection.
Products meet the requirements of the National Electrical Code(NEC).
• CSA C22.2 No.5
Standard for molded case circuit breakers (MCCB) for feeder andbranch circuit protection (corresponds closely to UL 489 Standard).
Products meet the requirements of the Canadian Electrical Code(CEC)
Standards – Supplementary Protection
• UL 1077
Standard for molded case circuit breakers (MCCB) for supplemen-tary protection of sensitive elctronic equipment or equipment thatrequires unique or specific overcurrent protection.
Products meet the requirements of the National Electrical Code(NEC).
• CSA C22.2 No.235
Equivalent to the UL 1077 Standard.
Products meet the requirements of the Canadian Electrical Code(CEC).
5
Device Printing on front and side
Type Designation
Min. distancebetween frontplate and de-vice shoulder
According toStandardIEC/EN
Rated VoltageIEC/EN
Rated BreakingCapacity IEC/EN
ReferenceCalibrationTemperature
Rated ImpulseWithstandVoltage
UtilisationCategory
GermanApprovalMark
Rated VoltageUL/CSA
Heating, Air Conditioning,Refrigeration
EAN-Code
RatedBreakingCapacityUL/CSA
CurrentLimiting
SwitchingDuty
TerminalCapacity
Suitable for60/75°C wire
Length ofuninsulatedconductor
Cu-conductorsonly
CalibrationTemperature acc.UL/CSA
Rated VoltageUL/CSA
Suitable forInsolation
Rated Current
FAZ-
NA
6
MMiinniiaattuurree CCiirrccuuiitt BBrreeaakkeerrss FFAAZZ-NNAA15 kA IEC; 10 kA UL/CSA, Characteristic C
Rated current In (A) Type Designation Article No. Units per package
Description Type Designation Article No. Units per package
14
Tech
nic
al D
ata
Acc
esso
ries
TTrriippppiinngg SSiiggnnaall SSwwiittcchh ZZ-NNHHKK,, ZZ-IIHHKK-NNAA• Design according to IEC/EN 60947-5-1, IEC/EN 62019• Can be mounted subsequently (screws)• The specified minimum voltages are per contact
Take into account particularly in case of series connection!• Contact function with relative movement (self-cleaning contacts)• Contact material and design particularly suitable for extra low voltage• ZZ-NNHHKK: The function of one of the two change-over contacts can be
switched from “auxiliary switch” to “tripping signal switch”• ZZ-IIHHKK-NNAA: will allow for FAZ-NA > 480Y/277 VAC rating• Tripping signal contact transmits message of electric tripping, not mechani-
cal switch-off• Test key for contact function “electrical tripping”
Technical Data
Connection diagram
ZZ-NNHHKK ZZ-IIHHKK-NNAA
EElleeccttrriiccaall Can be mounted from the left onto FAZ-NA, FAZ-RT, FAZ-XAA-NAContact function 2CO 1NO + 1NCRated voltage 230 V 250 VFrequency 50/60 Hz 50/60 HzRated current 2 A 6 ARated thermal current Ith 2 A 6 AUtilisation category AC13
Rated operational current Ie 3A/250V AC 3A/250V ACUtilisation category AC15
Rated operational current Ie 2A/250V AC 2A/250V ACUtilisation category DC12
Rated operational current Ie 0.5A/110V DC 0.5A/110V DC0.25A/220V DC
Rated insulation voltage UI 250 V AC 250 V ACMinimum operational voltage per contact Umin 5 V DC 5 V DCMinimum operational current Imin 10 mA DC 10 mA AC/DCRated peak withstand voltage Uimp (1.2/50µ) 2.5 kV 4 kVConditional short circuit current Ik
with back-up fuse 6A 1 kA 1 kAMax. back-up fuse, overload and short circuit 6 A gL
MMeecchhaanniiccaall Tripping indicator “electrical tripping” blue/white -Frame size 45 mm 45 mmDevice height 80 mm 80 mmDevice width 8.8 mm (0.5MU) 8.8 mm (0.5MU)Mounting onto switching dev.Degree of protection, built-in IP40 IP40Terminal protection finger and hand touch safe finger and hand touch safe
according to BGV A3, according to BGV A3,ÖVE-EN 6 ÖVE-EN 6
The voltage of the FAZ-... Circuit Breaker is limited to300 V with this Auxiliary Switch installed.
Z-NHK Z-IHK-NA
15
SShhuunntt TTrriipp RReelleeaassee FFAAZZ-XXAAAA-NNAA• Remote release for subsequent mounting onto FAZ-NA and FAZ-RT• Module width 1MU• Additional installation of standard auxiliary switch is possible• Position indicator red - green
EElleeccttrriiccaall Can be mounted onto FAZ-NA, FAZ-RT FAZ-NA, FAZ-RTOperational voltage range 12-110V AC 110-415V AC
12-60V DC 110-230V DCFrequency 50/60 Hz 50/60 HzPossible standard auxiliary switch Z-NHK Z-NHK
MMeecchhaanniiccaall Frame size 45 mm 45 mmDevice height 105 mm 105 mmDevice width 17.5 mm (1MU) 17.5 mm (1MU)Mounting quick fastening with 2 lock-in positions on DIN rail EN 50022Degree of protection, built-in IP40 IP40Terminal protection finger and hand touch safe according to BGV A3, ÖVE-EN 6Terminals open mouthed/lift open mouthed/liftTerminal capacity 1 and 2 Wires AWG 18-10 AWG 18-10
EElleeccttrriiccaall Rated operational voltage 480/277 VAC
96 VDCRated frequency 50/60 HzRated voltage – 690 VACOvervoltage category – IIIRated impulse withstand voltage Uimp – 9.5 kVRated current 80 A 80 ARated conditional short-circuit current AC with 350 A gG – 15 kAShort-circuit current 10 kA –
MMeecchhaanniiccaall Busbar cross section – 16 mm2 CuFlame class acc. to UL94 V0Pollution degree – 2Comparative tracking index – CTI 600Minimum clearance (intern/extern) – > 9.5 / 25.4 mmMinimum creepage distance (intern/extern) – > 12.7 / 50.8 mmResistance to climatic conditions – acc. to DIN/EN60068
• Tested according to UL489• Do not cut• Extension terminal 35 mm2 Z-EK/35/UL for copper conductors• For covering of not used pins use busbar tag shrouds ZV-BS-UL
Dimensions (mm)Z-SV/UL-16/.TE/6 Z-SV/UL-16/.TE/12
Z-SV/UL-16/.TE/18
ZV-BS-UL
Z-EK/35/UL
Busbar Connection Example Z-EK/35/ULUL489 IEC/EN60947-22
# 2-14 AWG 2.5-35 mm2
60/75°C Cu Cu
0.56 in 14 mm
tested aacc. tto Tightening ttorque of tterminal sscrews
UL486A # 14 AWG ≥ 2.3 Nm
UL486B # 8-12 AWG ≥ 2.8 Nm
UL486E # 6-1 AWG 4 Nm
16
Tech
nic
al D
ata
Acc
esso
ries
LLoocckkoouutt AAttttaacchhmmeenntt
.35 - .45 Nm
(3 - 4 lb-in)
OFF / O
LOCK OFF ONLY
3 mm
(1/8")
5.0 - 7.0 mm Ø
(3/16" - 9/32" Ø)
MCB UL 489
IS/SPE-1TE
17
Device Market In (A) at higher Ambient TemperatureCurrent Rating in
Eaton’s electrical business is a global leaderin electrical control, power distribution,uninterruptible power supply and industrialautomation products and services.
Eaton’s global electrical brands, includingCutler-Hammer®, MGE Office Protection SystemsTM, Powerware®, Holec®, MEM®, Santak and Moeller, provide customer-drivenPowerChain Management® solutions to servethe power system needs of the industrial,institutional, government, utility, commercial,residential, IT, mission critical and OEM marketsworldwide.