Top Banner
File Name: document.xls Version: 3.5 Original Date: 01-January-2011 Revised Date: 01-January-2015 Page No: 1 of 14 Eaton Hydraulics Component List Refer to Project Book Eaton Product Selection Guide for further selection and configuration info Picture Symbol Description Model Code Notes Detailed Model Component Code PVQ 013 PVQ 020 PVQ 032 PVQ 045 PVM 018/020 PVM 045 PVM 074 PVM 131 PVM 141 V10 V20 IHMG………………………… ME5 MTG STYLE IHMP………………………… ME6 MTG STYLE IHMCS……………………… MP5 MTG STYLE IHMA……………………… MS2 MTG STYLE IHMTT……………………… MT4 MTG STYLE IHMGD……………………… ME5 MTG STYLE IHMPD……………………… ME6 MTG STYLE IHMCSD……………………… MP5 MTG STYLE IHMAD……………………… MS2 MTG STYLE IHMTTD……………………… MT4 MTG STYLE DGMFN-3-Y-A1W-B1W-41 Meter out DGMFN-3-Y-B1W-41 Meter out DGMFN 3 Y A1W 41 Meter out DGMFN 5 Y A1W B1W 30 Meter out DGMFN 5 Y A1W 30 Meter out DGMFN 5 Y B1W 30 Meter out DGMDC 3 Y PK 41 DGMDC 3 X TK 41 DGMDC 5 Y PK 30 DGMDC 5 X TK 30 DGMPC 3 ABK BAK 41 DGMPC 3 ABK 41 DGMPC 3 BAK 41 DGMPC 5 ABK BAK 30 DGMPC 5 ABK 30 DGMPC 5 BAK 30 FN 03 20 B FN 06 21B FN 10 11B FG 3 16 H 10 FG 3 32 H 10 FG 3 63 H 10 FCG 3 16 H 10 FCG 3 32 H 10 FCG 3 63 H 10 FCG-H02-25-B-10 FCG-H02-50-B-10 Axial Piston Pump; Variable Displacement Vane Pump; Fixed Displacement Pumps can be used only after approval from FP Hydraulic Cylinder (Single rod) Hydraulic Cylinder (Double rod) Double throttle / check valve; Sandwich plate Check valve Sandwich plate Pilot Operated Check valve Sandwich plate Throttle check valve Flow control valve - Pressure Compensated
14

[XLS]pub/@eaton/@hyd/... · Web viewBOM Symbol Notes Axial Piston Pump; Variable Displacement PVM 074 PVM 131 Double throttle / check valve; Sandwich plate Check valve Sandwich plate

Jun 17, 2018

Download

Documents

dangnga
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: [XLS]pub/@eaton/@hyd/... · Web viewBOM Symbol Notes Axial Piston Pump; Variable Displacement PVM 074 PVM 131 Double throttle / check valve; Sandwich plate Check valve Sandwich plate

File Name: document.xlsVersion: 3.5Original Date: 01-January-2011Revised Date: 01-January-2015

Page No: 1 of 7

Eaton Hydraulics Component ListRefer to Project Book Eaton Product Selection Guide for further selection and configuration information.

Picture Symbol Description Model Code Notes QuantityDetailed Model Component Code

PVQ 013PVQ 020PVQ 032PVQ 045PVM 018/020PVM 045PVM 074PVM 131PVM 141V10V20

IHMG………………………… ME5 MTG STYLEIHMP………………………… ME6 MTG STYLEIHMCS……………………… MP5 MTG STYLEIHMA……………………… MS2 MTG STYLEIHMTT……………………… MT4 MTG STYLEIHMGD……………………… ME5 MTG STYLEIHMPD……………………… ME6 MTG STYLEIHMCSD……………………… MP5 MTG STYLEIHMAD……………………… MS2 MTG STYLEIHMTTD……………………… MT4 MTG STYLEDGMFN-3-Y-A1W-B1W-41 Meter outDGMFN-3-Y-B1W-41 Meter outDGMFN 3 Y A1W 41 Meter outDGMFN 5 Y A1W B1W 30 Meter outDGMFN 5 Y A1W 30 Meter outDGMFN 5 Y B1W 30 Meter outDGMDC 3 Y PK 41DGMDC 3 X TK 41DGMDC 5 Y PK 30DGMDC 5 X TK 30DGMPC 3 ABK BAK 41DGMPC 3 ABK 41DGMPC 3 BAK 41DGMPC 5 ABK BAK 30DGMPC 5 ABK 30DGMPC 5 BAK 30

Throttle check valveFN 03 20 B FN 06 21BFN 10 11BFG 3 16 H 10FG 3 32 H 10FG 3 63 H 10FCG 3 16 H 10FCG 3 32 H 10FCG 3 63 H 10FCG-H02-25-B-10FCG-H02-50-B-10

Axial Piston Pump; Variable Displacement

Vane Pump; Fixed Displacement

Pumps can be used only after approval

from FP

Hydraulic Cylinder (Single rod)

 Hydraulic Cylinder (Double rod)

Double throttle / check valve; Sandwich plate

Check valve Sandwich plate

Pilot Operated Check valve Sandwich plate

Flow control valve - Pressure Compensated

Page 2: [XLS]pub/@eaton/@hyd/... · Web viewBOM Symbol Notes Axial Piston Pump; Variable Displacement PVM 074 PVM 131 Double throttle / check valve; Sandwich plate Check valve Sandwich plate

File Name: document.xlsVersion: 3.5Original Date: 01-January-2011Revised Date: 01-January-2015

Page No: 2 of 7

Eaton Hydraulics Component ListRefer to Project Book Eaton Product Selection Guide for further selection and configuration information.

Picture Symbol Description Model Code Notes QuantityDetailed Model Component Code

FCG 02 300 50FCG 02 1500 50FCG 02 2300 50FCG 03 28 22

Pin 1 & Pin 2 : Not used

Pin 3 : 0 Volt ( ground )

Pin 4: 24 Volt ( Power )

Flow control valve - Press. & Temp. Compens.

Directional Control Valves -18 Watt, (Low Watt preferred)

DG4V-3-2A-VM-KUPM4L-D7-HL7-60

DG4V-3-2N-VM-KUPM4L-D7-HL7-60

DG4V-3-6C-VM-KUPM4L-D7-HL7-60

DG4V-3-33C-VM-KUPM4L-D7-HL7-60

DG4V-3-2C-VM-KUPM4L-D7-HL7-60

Directional Control Valves - 30 Watt coil

DG4V-3-2A-VM-KUPM4L-D7-H7-60

DG4V-3-2N-VM-KUPM4L-D7-H7-60

DG4V-3-6C-VM-KUPM4L-D7-H7-60

DG4V-3-33C-VM-KUPM4L-D7-H7-60

DG4V-3-2C-VM-KUPM4L-D7-H7-60

Directional Control Valves -30 Watt, (Low Watt preferred)

DG4V4-012A-VM-KUPM4L-D7-HL-4-10

DG4V4-012N-VM-KUPM4L-D7-HL-4-10

DG4V4-016C-VM-KUPM4L-D7-HL-4-10

DG4V4-0133C-VM-KUPM4L-D7-HL-4-10

DG4V4-012C-VM-KUPM4L-D7-HL-4-10

Directional Control Valves - 45 Watt coil

DG4V4-012A-VM-KUPM4L-D7-H-5-10

DG4V4-012N-VM-KUPM4L-D7-H-5-10

DG4V4-016C-VM-KUPM4L-D7-H-5-10

DG4V4-0133C-VM-KUPM4L-D7-H-5-10

DG4V4-012C-VM-KUPM4L-D7-H-5-10

Directional Control Valves - Pilot Operated - 8 Watt coil

DG5V-5-2A-VM-KUPM4L-D7-HM7-10

DG5V-5-2N-VM-KUPM4L-D7-HM7-10

DG5V-5-6C-VM-KUPM4L-D7-HM7-10

DG5V-5-33C-VM-KUPM4L-D7-HM7-10

Page 3: [XLS]pub/@eaton/@hyd/... · Web viewBOM Symbol Notes Axial Piston Pump; Variable Displacement PVM 074 PVM 131 Double throttle / check valve; Sandwich plate Check valve Sandwich plate

File Name: document.xlsVersion: 3.5Original Date: 01-January-2011Revised Date: 01-January-2015

Page No: 3 of 7

Eaton Hydraulics Component ListRefer to Project Book Eaton Product Selection Guide for further selection and configuration information.

Picture Symbol Description Model Code Notes QuantityDetailed Model Component Code

Directional Control Valves - Pilot Operated - 8 Watt coil

DG5V-5-2C-VM-KUPM4L-D7-HM7-10

Page 4: [XLS]pub/@eaton/@hyd/... · Web viewBOM Symbol Notes Axial Piston Pump; Variable Displacement PVM 074 PVM 131 Double throttle / check valve; Sandwich plate Check valve Sandwich plate

File Name: document.xlsVersion: 3.5Original Date: 01-January-2011Revised Date: 01-January-2015

Page No: 4 of 7

Eaton Hydraulics Component ListRefer to Project Book Eaton Product Selection Guide for further selection and configuration information.

Picture Symbol Description Model Code Notes QuantityDetailed Model Component Code

Sub Plate

DGVM 3 10 R NG6(D03) - G 3/8E DGSM 01Y 10 R NG10 (D05) - G ½E DGVM 7X D 10 R NG16(D07) - G 3/4E DGVM 8X D 10 R NG25(D08) - G1DGMS-3-2E-10-R - 2 Station A&B: G3/8, P&T:G ½ DGMS-3-3E-10-R - 3 Station A B Test Points G1/4DGMS-3-4E-10-R - 4 Station ISO 228 Ports DGMS-3-5E-10-R - 5 Station P & T : Both EndsDGMS-3-6E-10-R - 6 Station A& B : Side FaceDGMS-5-2E-10-R - 2 Station Available upon Request.

DGMS-5-3E-10-R - 3 Station A&B:G½ , P&T :G 3/4DGMS-5-4E-10-R - 4 Station A B Test Points G1/4DGMS-5-5E-10-R - 5 Station ISO 228 Ports DGMS-5-6E-10-R - 6 Station P & T : Both Ends

A& B : Side Face

DGMA 3DGMA 5

Cover Plates DGMA 3 C1 10KBDG4V-3KBFDG4V-3KBSDG4V-3KBDG4V-5KBFDG4V-5KBSDG4V-5KBDG5V-5/7/8/10KBFDG5V-5/7/8/10KBHDG5V-5/7/8/10K(B)X(C)G-6/8

KBCG-3EHST-3KBCG5-3

A2 30 I 060 BN M *A2 30 I 230 BN M *A2 30 J 578 BN M *A2 30 J 05G BN M *A2 30 K 10G BN M *A2 30 L 15G BN M *

Manifold blocks - NG6 (D03)

 Manifold blocks - NG10 (D05)

 Adaptor plates DGAM 3 01 10R Size NG10(D05) to NG6(D03)

Sandwich plate with different configurations

Proportional directional valves with integrated electronics

For complete model code, refer Appropriate

literature.

Proportional pressure control valves

For complete model code, refer Appropriate

literature.

Proportional pressure relief valves

For complete model code, refer Appropriate

literature.

Bladder Accumulator * - 22 for PED (97/23/EC) approved (for FP)

Page 5: [XLS]pub/@eaton/@hyd/... · Web viewBOM Symbol Notes Axial Piston Pump; Variable Displacement PVM 074 PVM 131 Double throttle / check valve; Sandwich plate Check valve Sandwich plate

File Name: document.xlsVersion: 3.5Original Date: 01-January-2011Revised Date: 01-January-2015

Page No: 5 of 7

Eaton Hydraulics Component ListRefer to Project Book Eaton Product Selection Guide for further selection and configuration information.

Picture Symbol Description Model Code Notes QuantityDetailed Model Component Code

100AV00093A

DARV W 6 K 10/ 25DARV W 6 K 10/ 50DARV W 6 K 10/ 100DARV W 6 K 10/ 200DARV W 10 K 10/ 25DARV W 10 K 10/ 50DARV W 10 K 10/ 100DARV W 10 K 10/ 200DGMC 3 PT AW 41DGMC 3 PT BW 41DGMC 3 PT CW 41DGMC 5 PT AW B 30DGMC 5 PT BW B 30DGMC 5 PT CW B 30DGMC 3 AT AW 41DGMC 3 AT BW 41DGMC 3 AT CW 41DGMC 5 AT AW B 30DGMC 5 AT BW B 30DGMC 5 AT CW B 30DGMC 3 BT AW 41DGMC 3 BT BW 41DGMC 3 BT CW 41DGMC 5 BT AW B 30DGMC 5 BT BW B 30DGMC 5 BT CW B 30DGMC2 3 AT BW BT BW 4

DGMR1 3 PP CW B 40

Charging and test device

Accumulator safety block (CE Marked)

NG 10- ESS 10E 16Y1-T250A-S10

For 1, 4 liters accumulators

NG 20- ESS 20E 16Y1-T250A-S12

For 10, 20 liters accumulators

NG 20- ESS 20E16Y1-T250A-S13

For 32 liters accumulators

NG 32- ESS 32E16Y1-T250A-S309

For 50 liters accumulators

Pressure relief valve ; Direct operated

Pressure relief valve; Pilot operated; Sandwich plate

2 Pressure relief valves; Pilot oper; Sandwich plate

Pressure sequence Valve - Z ; Sandwich plate

Page 6: [XLS]pub/@eaton/@hyd/... · Web viewBOM Symbol Notes Axial Piston Pump; Variable Displacement PVM 074 PVM 131 Double throttle / check valve; Sandwich plate Check valve Sandwich plate

File Name: document.xlsVersion: 3.5Original Date: 01-January-2011Revised Date: 01-January-2015

Page No: 6 of 7

Eaton Hydraulics Component ListRefer to Project Book Eaton Product Selection Guide for further selection and configuration information.

Picture Symbol Description Model Code Notes QuantityDetailed Model Component Code

DGMX1 3 PP AW B 40DGMX1 3 PP BW B 40DGMX1 3 PP CW B 40DGMX2 5 PP AW B 30DGMX2 5 PP BW B 30DGMX2 5 PP CW B 30DGMX1 3 PA AW B 40DGMX1 3 PA BW B 40DGMX1 3 PA CW B 40DGMX2 5 PA AW B 30DGMX2 5 PA BW B 30DGMX2 5 PA CW B 30DGMX1 3 PB AW B 40DGMX1 3 PB BW B 40DGMX1 3 PB CW B 40DGMX2 5 PB AW B 30DGMX2 5 PB BW B 30DGMX2 5 PB CW B 30X(C)G2V 6/8X(C)G2V-10

1 PU L 65Cartridge with Body

1 PU L 250

CG2V-6/8 & CG5V-6/8CG2V-10 & CG5V-10

Air BreatherMBR110 MOBILE-GATE 3/4"

H2O GATE VENT BREATHER

DMP*******TH**** Confirms to DIN Spec

VDP Confirms to DIN Spec

DRT1*****4RHN**** Confirms to DIN Spec

VDT Confirms to DIN Spec

Pressure reducing valve; Direct operated; Sandwich plate; Sleeve with hexagon and protect cap

Pressure reducing valve, pilot operated

Pressure cut-off valve, pilot operated

Pressure cut-off valve, pilot operated

Pressure Filter with Elec. clog indicator

Pressure Filter Element

Return line filter with Elec. clog indicator

Return line filter Element

Page 7: [XLS]pub/@eaton/@hyd/... · Web viewBOM Symbol Notes Axial Piston Pump; Variable Displacement PVM 074 PVM 131 Double throttle / check valve; Sandwich plate Check valve Sandwich plate

File Name: document.xlsVersion: 3.5Original Date: 01-January-2011Revised Date: 01-January-2015

Page No: 7 of 7

Eaton Hydraulics Component ListRefer to Project Book Eaton Product Selection Guide for further selection and configuration information.

Picture Symbol Description Model Code Notes QuantityDetailed Model Component Code

Fittings

WalRing Coupling

Hose & Hose fittings

GH195 MATCHMATE Per ISO S1436/IIEaton Hose Fittings

Gauge In-Range Overlay

Eaton Walterscheid Tube Coupling

Pressure Gauge63 mm (2.5 inch)PSI- MPa Scale

BSPP-G-1/4 maleGlycerin- Filled

WIKA model 233.5x or equivalent Pressure Gauge

A Dual-Scale PressureGauge is required withPSI and Mpa scaleUnits on the Dial

PSI-MPa Scale 1500PSI Range, 10 Mpa Range BSPP- G1/4 B Male connection Mount LM (Lower) or CBM (center-back)

Gauge VisualIn-Range Overlay

A visual In-Range is required for all pressure gauges.Green +/-15% = targetSet-point, Red 85% = out of range